Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Opt Lett ; 48(19): 5145-5148, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37773406

RESUMEN

In this Letter, we present a portable all-fiber fluorescent detection system based on metal-lined hollow-core fiber (MLHCF) for the ultra-sensitive real-time monitoring of mercury ions (Hg2+). The system employs a rhodamine derivative as the probe. The hollow core of the MLHCF serves as both the flow channel of the liquid sample and the waveguide of the optical path. The metal coating in the intermediate layer between the capillary and the polyimide (PI) coating in the MLHCF provides good light confinement, enhancing the interaction between the sample and the incident light for better fluorescence excitation and collection efficiency. Additionally, further enhancement is achieved by placing an inserted filter along the light path to reflect the excitation light back to the MLHCF. A 3-cm length of MLHCF enables simultaneous excitation of a 40-µL sample volume and collection of most of its fluorescent signal in all directions, thereby significantly contributing to its exceptional sensitivity with a limit of detection (LOD) of 2.3 ng/L. The all-fiber fluorescence-enhanced detection device also shows rapid response time, excellent reusability, and selectivity. This system presents an online, reproducible, and portable solution for the trace detection of Hg2+ and provides a promising way for detecting other heavy metal ions.

2.
Opt Express ; 30(2): 1152-1166, 2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35209281

RESUMEN

We have manufactured an intensity modulated optical fiber SMDMS sensor with hydroxyethyl cellulose (HEC) hydrogel coating for simultaneous measurement of RH and temperature. The SMDMS sensor was manufactured by splicing single-mode fiber (SMF), multi-mode fiber (MMF), dispersion compensation fiber (DCF), MMF, and SMF in sequence to form a structure of SMF + MMF + DCF + MMF + SMF (SMDMS). The cladding of MMFs and DCF were corroded by hydrofluoric acid (HF) and coated with HEC hydrogel to excite a strong evanescent field and increase the sensitivity of the SMDMS sensor. The adsorption of water molecules by HEC will cause a change in the effective refractive index of cladding mode, which will eventually change the intensity of the transmission spectrum. The experimental results indicate that the sensitivities are 0.507 dB/%RH and 0.345 dB/°C in the RH range of 30%-80% and temperature range of 10°C-50°C, respectively. At last, a dual-parameter measurement matrix is constructed based on the experimental results to achieve the simultaneous measurement of RH and temperature. The SMDMS sensor has the advantages of high sensitivity and good robustness, and has potential application prospects in daily life and other fields.

3.
Opt Express ; 30(26): 47216-47234, 2022 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-36558655

RESUMEN

In this paper, an asymmetric structure optical fiber sensor is proposed to measure relative humidity (RH). The sensing structure is composed of splicing dispersion compensation fiber (DCF) and coreless fiber (NCF), and two sections of single-mode fiber (SMF) at both ends. Peanut shaped structure is used as a beam splitter at the input side, and the NCF is used as a beam combiner at the output side to form interference fringes. The partial cladding of DCF was etched, and polyvinyl alcohol (PVA) was coated on the etched area to form a hygroscopic film. When the ambient humidity changes, the refractive index and thickness of the hygroscopic film will change, which will lead to the wavelength shift of the resonant dip. The experimental results show that the sensitivity of the sensor is 0.1304 nm/RH% and 0.4452 nm/RH% in the RH range of 55%-75% and 75%-95%, respectively. In order to improve the sensitivity further, the original spectrum data is filtered by fast Fourier transform (FFT) and inverse fast Fourier transform (IFFT), and the high-frequency interference components of high-order mode (LP09) and fundamental mode are obtained, which is superimposed with a simulated signal to form Vernier effect. With the method of virtual Vernier effect, the sensitivity in the RH range of 55%-75% is improved to 2.869 nm/RH%, which is 22 times larger than the original sensitivity, and the sensitivity in the RH range of 75%-95% is improved to 2.64 nm/RH%, which is 6 times larger than the original sensitivity.

4.
Opt Express ; 29(15): 24102-24117, 2021 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-34614661

RESUMEN

A single core-offset Mach-Zehnder interferometer (MZI) coated with polyvinyl alcohol (PVA) for simultaneous measurement of relative humidity (RH) and temperature is proposed in this paper. The sensing structure is fabricated by splicing dispersion compensating fiber (DCF) and no-core fiber (NCF) and splicing two single-mode fibers (SMF) at both ends, where the core-offset is located at the splicing of SMF and DCF. A part of the cladding of DCF is etched to excite the high-order cladding mode (LP10), and PVA is coated on the etched area. The refractive index of PVA varies due to the adsorption of water molecules. Therefore, when the ambient relative humidity and temperature change, the change of MZI phase difference causes the wavelength of the resonant dip to shift. The experimental results indicate that the proposed sensor has a sensitivity of 0.256 nm/RH% for RH range of 30%-95%, and a sensitivity of 0.153 nm/℃ for temperature range of 20℃-80℃, respectively. The simultaneous measurement of RH and temperature can be achieved by demodulating the sensitivity coefficient matrix. The proposed sensor has the characteristics of good repeatability, high sensitivity, and good stability, which make it potentially applications for the detection of RH and temperature measurement.

5.
Biosens Bioelectron ; 261: 116505, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38885536

RESUMEN

Surface enhanced Raman spectroscopy (SERS) utilizes the fingerprint features of molecular vibrations to identify and detect substances. However, in traditional single focus excitation scenarios, its signal collection efficiency of the objective is restricted. Furthermore, the uneven distribution of samples on the SERS substrate would result in poor signal stability, while the excitation power is limited to avoid sample damage. SERS detection system always requires precise adjustment of focal length and spot size, making it difficult for point-of-care testing applications. Here, we proposed a SERS microfluidic chip with barium titanate microspheres array (BTMA) embedded using vacuum self-assembled hot-pressing method for SERS detection with simultaneous enhancement of sensitivity and stability. Due to photonic nano-jets and directional antenna effects, high index microspheres are perfect micro-lens for effective light focusing and signal collecting. The BTMA can not only disperse excitation beam into an array of focal points covering the target uniformly with very low signal fluctuation, but enlarge the power threshold for higher signal intensity. We conducted a proof-of-principle experiment on chip for the detection of bacteria with immuno-magnetic tags and immuno-SERS tags. Together with magnetic and ultrasonic operations, the target bacteria in the flow were evenly congregated on the focal plane of BTMA. It demonstrated a limit of detection of 5 cells/mL, excellent signal reproducibility (error∼4.84%), and excellent position tolerance of 500 µm in X-Y plane (error∼5.375%). It can be seen that BTMA-SERS microfluidic chip can effectively solve the contradiction between sensitivity and stability in SERS detection.


Asunto(s)
Técnicas Biosensibles , Dispositivos Laboratorio en un Chip , Microesferas , Espectrometría Raman , Espectrometría Raman/instrumentación , Espectrometría Raman/métodos , Técnicas Biosensibles/instrumentación , Límite de Detección , Diseño de Equipo , Titanio/química , Lentes , Escherichia coli/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA