Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-35982992

RESUMEN

Fused filament fabrication three-dimensional (FFF 3-D) printing is thought to be environmentally sustainable; however, significant amounts of waste can be generated from this technology. One way to improve its sustainability is via distributed recycling of plastics in homes, schools, and libraries to create feedstock filament for printing. Risks from exposures incurred during recycling and reuse of plastics has not been incorporated into life cycle assessments. This study characterized contaminant releases from virgin (unextruded) and recycled plastics from filament production through FFF 3-D printing. Waste polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS) plastics were recycled to create filament; virgin PLA, ABS, high and low density polyethylenes, high impact polystyrene, and polypropylene pellets were also extruded into filament. The release of particles and chemicals into school classrooms was evaluated using standard industrial hygiene methodologies. All tasks released particles that contained hazardous metals (e.g., manganese) and with size capable of depositing in the gas exchange region of the lung, i.e., granulation of waste PLA and ABS (667 to 714 nm) and filament making (608 to 711 nm) and FFF 3-D printing (616 to 731 nm) with waste and virgin plastics. All tasks released vapors, including respiratory irritants and potential carcinogens (benzene and formaldehyde), mucus membrane irritants (acetone, xylenes, ethylbenzene, and methyl methacrylate), and asthmagens (styrene, multiple carbonyl compounds). These data are useful for incorporating risks of exposure to hazardous contaminants in future life cycle evaluations to demonstrate the sustainability and circular economy potential of FFF 3-D printing in distributed spaces.

2.
Toxicol Appl Pharmacol ; 408: 115281, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33065155

RESUMEN

Cultured murine macrophages (RAW 264.7) were used to investigate the effects of fracking sand dust (FSD) for its pro-inflammatory activity, in order to gain insight into the potential toxicity to workers associated with inhalation of FSD during hydraulic fracturing. While the role of respirable crystalline silica in the development of silicosis is well documented, nothing is known about the toxicity of inhaled FSD. The FSD (FSD 8) used in these studies was from an unconventional gas well drilling site. FSD 8was prepared as a 10 mg/ml stock solution in sterile PBS, vortexed for 15 s, and allowed to sit at room temperature for 30 min before applying the suspension to RAW 264.7cells. Compared to PBS controls, cellular viability was significantly decreased after a 24 h exposure to FSD. Intracellular reactive oxygen species (ROS) production and the production of IL-6, TNFα, and endothelin-1 (ET-1) were up-regulated as a result of the exposure, whereas the hydroxyl radical (.OH) was only detected in an acellular system. Immunofluorescent staining of cells against TNFα revealed that FSD 8 caused cellular blebbing, and engulfment of FSD 8 by macrophages was observed with enhanced dark-field microscopy. The observed changes in cellular viability, cellular morphology, free radical generation and cytokine production all confirm that FSD 8 is cytotoxic to RAW 264.7 cells and warrants future studies into the specific pathways and mechanisms by which these toxicities occur.


Asunto(s)
Polvo , Fracking Hidráulico , Arena , Animales , Supervivencia Celular , Ensayo Cometa , Inflamación , Interleucina-6 , Ratones , Células RAW 264.7 , Especies Reactivas de Oxígeno , Factor de Necrosis Tumoral alfa
3.
Inhal Toxicol ; 31(13-14): 432-445, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31874579

RESUMEN

Objective: Fused filament fabrication "3-dimensional (3-D)" printing has expanded beyond the workplace to 3-D printers and pens for use by children as toys to create objects.Materials and methods: Emissions from two brands of toy 3-D pens and one brand of toy 3-D printer were characterized in a 0.6 m3 chamber (particle number, size, elemental composition; concentrations of individual and total volatile organic compounds (TVOC)). The effects of print parameters on these emission metrics were evaluated using mixed-effects models. Emissions data were used to model particle lung deposition and TVOC exposure potential.Results: Geometric mean particle yields (106-1010 particles/g printed) and sizes (30-300 nm) and TVOC yields (

Asunto(s)
Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Material Particulado/análisis , Juego e Implementos de Juego , Impresión Tridimensional , Compuestos Orgánicos Volátiles/análisis , Niño , Humanos , Tamaño de la Partícula
4.
J Occup Environ Hyg ; 14(7): 540-550, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28440728

RESUMEN

Printing devices are known to emit chemicals into the indoor atmosphere. Understanding factors that influence release of chemical contaminants from printers is necessary to develop effective exposure assessment and control strategies. In this study, a desktop fused deposition modeling (FDM) 3-dimensional (3-D) printer using acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) filaments and two monochrome laser printers were evaluated in a 0.5 m3 chamber. During printing, chamber air was monitored for vapors using a real-time photoionization detector (results expressed as isobutylene equivalents) to measure total volatile organic compound (TVOC) concentrations, evacuated canisters to identify specific VOCs by off-line gas chromatography-mass spectrometry (GC-MS) analysis, and liquid bubblers to identify carbonyl compounds by GC-MS. Airborne particles were collected on filters for off-line analysis using scanning electron microscopy with an energy dispersive x-ray detector to identify elemental constituents. For 3-D printing, TVOC emission rates were influenced by a printer malfunction, filament type, and to a lesser extent, by filament color; however, rates were not influenced by the number of printer nozzles used or the manufacturer's provided cover. TVOC emission rates were significantly lower for the 3-D printer (49-3552 µg h-1) compared to the laser printers (5782-7735 µg h-1). A total of 14 VOCs were identified during 3-D printing that were not present during laser printing. 3-D printed objects continued to off-gas styrene, indicating potential for continued exposure after the print job is completed. Carbonyl reaction products were likely formed from emissions of the 3-D printer, including 4-oxopentanal. Ultrafine particles generated by the 3-D printer using ABS and a laser printer contained chromium. Consideration of the factors that influenced the release of chemical contaminants (including known and suspected asthmagens such as styrene and 4-oxopentanal) from a FDM 3-D printer should be made when designing exposure assessment and control strategies.


Asunto(s)
Contaminación del Aire Interior/análisis , Material Particulado/análisis , Impresión Tridimensional , Compuestos Orgánicos Volátiles/análisis , Acrilonitrilo/análisis , Aldehídos/análisis , Butadienos , Cromo/análisis , Monitoreo del Ambiente/métodos , Cetonas/análisis , Poliésteres , Estireno/análisis
5.
J Toxicol Environ Health A ; 79(11): 453-65, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27196745

RESUMEN

Desktop three-dimensional (3D) printers are becoming commonplace in business offices, public libraries, university labs and classrooms, and even private homes; however, these settings are generally not designed for exposure control. Prior experience with a variety of office equipment devices such as laser printers that emit ultrafine particles (UFP) suggests the need to characterize 3D printer emissions to enable reliable risk assessment. The aim of this study was to examine factors that influence particulate emissions from 3D printers and characterize their physical properties to inform risk assessment. Emissions were evaluated in a 0.5-m(3) chamber and in a small room (32.7 m(3)) using real-time instrumentation to measure particle number, size distribution, mass, and surface area. Factors evaluated included filament composition and color, as well as the manufacturer-provided printer emissions control technologies while printing an object. Filament type significantly influenced emissions, with acrylonitrile butadiene styrene (ABS) emitting larger particles than polylactic acid (PLA), which may have been the result of agglomeration. Geometric mean particle sizes and total particle (TP) number and mass emissions differed significantly among colors of a given filament type. Use of a cover on the printer reduced TP emissions by a factor of 2. Lung deposition calculations indicated a threefold higher PLA particle deposition in alveoli compared to ABS. Desktop 3D printers emit high levels of UFP, which are released into indoor environments where adequate ventilation may not be present to control emissions. Emissions in nonindustrial settings need to be reduced through the use of a hierarchy of controls, beginning with device design, followed by engineering controls (ventilation) and administrative controls such as choice of filament composition and color.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Material Particulado/análisis , Impresión Tridimensional , Tamaño de la Partícula , Ventilación
6.
J Occup Environ Hyg ; 13(10): 770-81, 2016 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-27105025

RESUMEN

Obliterative bronchiolitis in five former coffee processing employees at a single workplace prompted an exposure study of current workers. Exposure characterization was performed by observing processes, assessing the ventilation system and pressure relationships, analyzing headspace of flavoring samples, and collecting and analyzing personal breathing zone and area air samples for diacetyl and 2,3-pentanedione vapors and total inhalable dust by work area and job title. Mean airborne concentrations were calculated using the minimum variance unbiased estimator of the arithmetic mean. Workers in the grinding/packaging area for unflavored coffee had the highest mean diacetyl exposures, with personal concentrations averaging 93 parts per billion (ppb). This area was under positive pressure with respect to flavored coffee production (mean personal diacetyl levels of 80 ppb). The 2,3-pentanedione exposures were highest in the flavoring room with mean personal exposures of 122 ppb, followed by exposures in the unflavored coffee grinding/packaging area (53 ppb). Peak 15-min airborne concentrations of 14,300 ppb diacetyl and 13,800 ppb 2,3-pentanedione were measured at a small open hatch in the lid of a hopper containing ground unflavored coffee on the mezzanine over the grinding/packaging area. Three out of the four bulk coffee flavorings tested had at least a factor of two higher 2,3-pentanedione than diacetyl headspace measurements. At a coffee processing facility producing both unflavored and flavored coffee, we found the grinding and packaging of unflavored coffee generate simultaneous exposures to diacetyl and 2,3-pentanedione that were well in excess of the NIOSH proposed RELs and similar in magnitude to those in the areas using a flavoring substitute for diacetyl. These findings require physicians to be alert for obliterative bronchiolitis and employers, government, and public health consultants to assess the similarities and differences across the industry to motivate preventive intervention where indicated by exposures above the proposed RELs for diacetyl and 2,3-pentanedione.


Asunto(s)
Contaminantes Ocupacionales del Aire , Café , Diacetil/análisis , Exposición Profesional/análisis , Pentanonas/análisis , Contaminantes Ocupacionales del Aire/análisis , Bronquiolitis Obliterante/prevención & control , Polvo/análisis , Aromatizantes/análisis , Industria de Procesamiento de Alimentos/métodos , Humanos
7.
Am J Ind Med ; 58(12): 1235-45, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26523478

RESUMEN

RATIONALE: Obliterative bronchiolitis in former coffee workers prompted a cross-sectional study of current workers. Diacetyl and 2,3-pentanedione levels were highest in areas for flavoring and grinding/packaging unflavored coffee. METHODS: We interviewed 75 (88%) workers, measured lung function, and created exposure groups based on work history. We calculated standardized morbidity ratios (SMRs) for symptoms and spirometric abnormalities. We examined health outcomes by exposure groups. RESULTS: SMRs were elevated 1.6-fold for dyspnea and 2.7-fold for obstruction. The exposure group working in both coffee flavoring and grinding/packaging of unflavored coffee areas had significantly lower mean ratio of forced expiratory volume in 1 s to forced vital capacity and percent predicted mid-expiratory flow than workers without such exposure. CONCLUSION: Current workers have occupational lung morbidity associated with high diacetyl and 2,3-pentanedione exposures, which were not limited to flavoring areas.


Asunto(s)
Bronquiolitis Obliterante/inducido químicamente , Café/química , Industria de Procesamiento de Alimentos , Enfermedades Profesionales/inducido químicamente , Exposición Profesional/efectos adversos , Adulto , Obstrucción de las Vías Aéreas/inducido químicamente , Bronquiolitis Obliterante/epidemiología , Bronquiolitis Obliterante/fisiopatología , Estudios Transversales , Diacetil/análisis , Diacetil/toxicidad , Disnea/inducido químicamente , Femenino , Aromatizantes/análisis , Volumen Espiratorio Forzado , Humanos , Pulmón/fisiopatología , Masculino , Enfermedades Profesionales/epidemiología , Enfermedades Profesionales/fisiopatología , Exposición Profesional/análisis , Pentanonas/análisis , Pentanonas/toxicidad , Respiración , Espirometría , Capacidad Vital , Lugar de Trabajo
8.
Aerosol Sci Technol ; 57(3): 215-232, 2023 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-37206373

RESUMEN

SARS-CoV-2 spreads by infectious aerosols and droplets from the respiratory tract. Masks and respirators can reduce the transmission of infectious respiratory diseases by collecting these aerosols at the source. The ability of source control devices to block aerosols can be tested by expelling an aerosol through a headform using constant airflows, which are simpler, or cyclic airflows, which are more realistic but require more complex methods. Experiments with respirators found that using cyclic vs. constant flows affected the amount of aerosol inhaled, but similar comparisons have not been made for source control devices with exhaled aerosols. We measured the collection efficiencies for exhaled aerosols for two cloth masks, two medical masks with and without an elastic mask brace, a neck gaiter, and an N95 filtering facepiece respirator using 15 L/min and 85 L/min constant and cyclic flows and a headform with pliable skin. The collection efficiencies for the 15 L/min cyclic flow, 15 L/min constant flow, and 85 L/min constant flow were not significantly different in most cases. The apparent collection efficiencies for the 85 L/min cyclic flow were artificially increased by rebreathing and refiltration of the aerosol from the collection chamber. The collection efficiencies correlated well with the fit factors (ρ > 0.95) but not the filtration efficiencies (ρ < 0.54). Our results suggest that the aerosol collection efficiency measurements of source control devices are comparable when testing the devices using either constant or cyclic airflows and that the potential for aerosol rebreathing must be considered when conducting experiments.

9.
Environ Geochem Health ; 34(3): 313-22, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21866318

RESUMEN

Exposure to some manufactured beryllium compounds via skin contact or inhalation can cause sensitization. A portion of sensitized persons who inhale beryllium may develop chronic beryllium disease (CBD). Little is understood about exposures to naturally occurring beryllium minerals. The purpose of this study was to assess the bioaccessibility of beryllium from bertrandite ore. Dissolution of bertrandite from two mine pits (Monitor and Blue Chalk) was evaluated for both the dermal and inhalation exposure pathways by determining bioaccessibility in artificial sweat (pH 5.3 and pH 6.5), airway lining fluid (SUF, pH 7.3), and alveolar macrophage phagolysosomal fluid (PSF, pH 4.5). Significantly more beryllium was released from Monitor pit ore than Blue Chalk pit ore in artificial sweat buffered to pH 5.3 (0.88 ± 0.01% vs. 0.36 ± 0.00%) and pH 6.5 (0.09 ± 0.00% vs. 0.03 ± 0.01%). Rates of beryllium released from the ores in artificial sweat were faster than previously measured for manufactured forms of beryllium (e.g., beryllium oxide), known to induce sensitization in mice. In SUF, levels of beryllium were below the analytical limit of detection. In PSF, beryllium dissolution was biphasic (initial rapid diffusion followed by latter slower surface reactions). During the latter phase, dissolution half-times were 1,400 to 2,000 days, and rate constants were ~7 × 10(-10) g/(cm(2)·day), indicating that bertrandite is persistent in the lung. These data indicate that it is prudent to control skin and inhalation exposures to bertrandite dusts.


Asunto(s)
Berilio/análisis , Berilio/toxicidad , Exposición por Inhalación , Pulmón/química , Minería , Exposición Profesional , Sudor/química , Berilio/metabolismo , Humanos , Pulmón/efectos de los fármacos , Pulmón/metabolismo , Fagosomas/química , Fagosomas/efectos de los fármacos , Fagosomas/metabolismo , Alveolos Pulmonares/química , Silicatos/química , Silicatos/metabolismo , Silicatos/toxicidad , Sudor/efectos de los fármacos , Sudor/metabolismo , Utah , Difracción de Rayos X
10.
Am J Infect Control ; 50(2): 133-140, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34924208

RESUMEN

BACKGROUND: During the COVID-19 pandemic, face masks are used as source control devices to reduce the expulsion of respiratory aerosols from infected people. Modifications such as mask braces, earloop straps, knotting and tucking, and double masking have been proposed to improve mask fit however the data on source control are limited. METHODS: The effectiveness of mask fit modifications was determined by conducting fit tests on human subjects and simulator manikins and by performing simulated coughs and exhalations using a source control measurement system. RESULTS: Medical masks without modification blocked ≥56% of cough aerosols and ≥42% of exhaled aerosols. Modifying fit by crossing the earloops or placing a bracket under the mask did not increase performance, while using earloop toggles, an earloop strap, and knotting and tucking the mask increased performance. The most effective modifications for improving source control performance were double masking and using a mask brace. Placing a cloth mask over a medical mask blocked ≥85% of cough aerosols and ≥91% of exhaled aerosols. Placing a brace over a medical mask blocked ≥95% of cough aerosols and ≥99% of exhaled aerosols. CONCLUSIONS: Fit modifications can greatly improve the performance of face masks as source control devices for respiratory aerosols.


Asunto(s)
COVID-19 , Máscaras , Aerosoles , Humanos , Pandemias , SARS-CoV-2
11.
Aerosol Sci Technol ; 55(10): 1125-1142, 2021 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-35923216

RESUMEN

Universal mask wearing is recommended to help control the spread of COVID-19. Masks reduce the expulsion of aerosols of respiratory fluids into the environment (called source control) and offer some protection to the wearer. Masks are often characterized using filtration efficiency, airflow resistance, and manikin or human fit factors, which are standard metrics used for personal protective devices. However, none of these metrics are direct measurements of how effectively a mask blocks coughed and exhaled aerosols. We studied the source control performance of 15 cloth masks (face masks, neck gaiters, and bandanas), two medical masks, and two N95 filtering facepiece respirators by measuring their ability to block aerosols ≤ 7 µm expelled during simulated coughing and exhalation (called source control collection efficiency). These measurements were compared with filtration efficiencies, airflow resistances, and fit factors measured on manikin headforms and humans. Collection efficiencies for the cloth masks ranged from 17% to 71% for coughing and 35% to 66% for exhalation. Filtration efficiencies for the cloth masks ranged from 1.4% to 98%, while the fit factors were 1.3 to 7.4 on headforms and 1.0 to 4.0 on human subjects. The Spearman's rank correlation coefficients between the source control collection efficiencies and the standard metrics ranged from 0.03 to 0.68 and were significant in all but two cases. However, none of the standard metrics were strongly correlated with source control performance. A better understanding of the relationships between source control collection efficiency, filtration efficiency, airflow resistance, and fit factor is needed.

12.
J Chem Health Saf ; 28(6): 444-456, 2021 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-35979087

RESUMEN

Material extrusion-type fused filament fabrication (FFF) 3-D printing is a valuable tool for education. During FFF 3-D printing, thermal degradation of the polymer releases small particles and chemicals, many of which are hazardous to human health. In this study, particle and chemical emissions from 10 different filaments made from virgin (never printed) and recycled polymers were used to print the same object at the polymer manufacturer's recommended nozzle temperature ("normal") and at a temperature higher than recommended ("hot") to simulate the real-world scenarios of a person intentionally or unknowingly printing on a machine with a changed setting. Emissions were evaluated in a college teaching laboratory using standard sampling and analytical methods. From mobility sizer measurements, particle number-based emission rates were 81 times higher; the proportion of ultrafine particles (diameter <100 nm) were 4% higher, and median particle sizes were a factor of 2 smaller for hot-temperature prints compared with normal-temperature prints (all p-values <0.05). There was no difference in emission characteristics between recycled and virgin acrylonitrile butadiene styrene and polylactic acid polymer filaments. Reducing contaminant release from FFF 3-D printers in educational settings can be achieved using the hierarchy of controls: (1) elimination/substitution (e.g., training students on principles of prevention-through-design, limiting the use of higher emitting polymer when possible); (2) engineering controls (e.g., using local exhaust ventilation to directly remove contaminants at the printer or isolating the printer from students); (3) administrative controls such as password protecting printer settings and establishing and enforcing adherence to a standard operating procedure based on a proper risk assessment for the setup and use (e.g., limiting the use of temperatures higher than those specified for the filaments used); and (4) maintenance of printers.

13.
medRxiv ; 2021 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-33619500

RESUMEN

Universal mask wearing is recommended by the Centers for Disease Control and Prevention to help control the spread of COVID-19. Masks reduce the expulsion of respiratory aerosols (called source control) and offer some protection to the wearer. However, masks vary greatly in their designs and construction materials, and it is not clear which are most effective. Our study tested 15 reusable cloth masks (which included face masks, neck gaiters, and bandanas), two medical masks, and two N95 filtering facepiece respirators as source control devices for aerosols ≤ 7 µm produced during simulated coughing and exhalation. These measurements were compared with the mask filtration efficiencies, airflow resistances, and fit factors. The source control collection efficiencies for the cloth masks ranged from 17% to 71% for coughing and 35% to 66% for exhalation. The filtration efficiencies of the cloth masks ranged from 1.4% to 98%, while the fit factors were 1.3 to 7.4 on an elastomeric manikin headform and 1.0 to 4.0 on human test subjects. The correlation coefficients between the source control efficacies and the other performance metrics ranged from 0.31 to 0.66 and were significant in all but one case. However, none of the alternative metrics were strong predictors of the source control performance of cloth masks. Our results suggest that a better understanding of the relationships between source control performance and metrics like filtration efficiency, airflow resistance, and fit factor are needed to develop simple methods to estimate the effectiveness of masks as source control devices for respiratory aerosols.

14.
J Chem Health Saf ; 28(3): 190-200, 2021 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-35979329

RESUMEN

The literature on emissions during material extrusion additive manufacturing with 3-D printers is expanding; however, there is a paucity of data for large-format additive manufacturing (LFAM) machines that can extrude high-melt-temperature polymers. Emissions from two LFAM machines were monitored during extrusion of six polymers: acrylonitrile butadiene styrene (ABS), polycarbonate (PC), high-melt-temperature polysulfone (PSU), poly(ether sulfone) (PESU), polyphenylene sulfide (PPS), and Ultem (poly(ether imide)). Particle number, total volatile organic compound (TVOC), carbon monoxide (CO), and carbon dioxide (CO2) concentrations were monitored in real-time. Particle emission rate values (no./min) were as follows: ABS (1.7 × 1011 to 7.7 × 1013), PC (5.2 × 1011 to 3.6 × 1013), Ultem (5.7 × 1012 to 3.1 × 1013), PPS (4.6 × 1011 to 6.2 × 1012), PSU (1.5 × 1012 to 3.4 × 1013), and PESU (2.0 to 5.0 × 1013). For print jobs where the mass of extruded polymer was known, particle yield values (g-1 extruded) were as follows: ABS (4.5 × 108 to 2.9 × 1011), PC (1.0 × 109 to 1.7 × 1011), PSU (5.1 × 109 to 1.2 × 1011), and PESU (0.8 × 1011 to 1.7 × 1011). TVOC emission yields ranged from 0.005 mg/g extruded (PESU) to 0.7 mg/g extruded (ABS). The use of wall-mounted exhaust ventilation fans was insufficient to completely remove airborne particulate and TVOC from the print room. Real-time CO monitoring was not a useful marker of particulate and TVOC emission profiles for Ultem, PPS, or PSU. Average CO2 and particle concentrations were moderately correlated (r s = 0.76) for PC polymer. Extrusion of ABS, PC, and four high-melt-temperature polymers by LFAM machines released particulate and TVOC at levels that could warrant consideration of engineering controls. LFAM particle emission yields for some polymers were similar to those of common desktop-scale 3-D printers.

15.
J Chem Health Saf ; 28(4): 268-278, 2021 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-36147482

RESUMEN

Extrusion of high-melt-temperature polymers on large-format additive manufacturing (LFAM) machines releases particles and gases, though there is no data describing their physical and chemical characteristics. Emissions from two LFAM machines were monitored during extrusion of acrylonitrile butadiene styrene (ABS) and polycarbonate (PC) polymers as well as high-melt-temperature Ultem (poly(ether imide)), polysulfone (PSU), poly(ether sulfone) (PESU), and polyphenylene sulfide (PPS) polymers. Filter samples of particles were collected for quantification of elements and bisphenol A and S (BPA, BPS) and visualization of morphology. Individual gases were quantified on substance-specific media. Aerosol sampling demonstrated that concentrations of elements were generally low for all polymers, with a maximum of 1.6 mg/m3 for iron during extrusion of Ultem. BPA, an endocrine disruptor, was released into air during extrusion of PC (range: 0.4 ± 0.1 to 21.3 ± 5.3 µg/m3). BPA and BPS (also an endocrine disruptor) were released into air during extrusion of PESU (BPA, 2.0-8.7 µg/m3; BPS, 0.03-0.07 µg/m3). Work surfaces and printed parts were contaminated with BPA (<8-587 ng/100 cm2) and BPS (<0.22-2.5 ng/100 cm2). Gas-phase sampling quantified low levels of respiratory irritants (phenol, SO2, toluene, xylenes), possible or known asthmagens (caprolactam, methyl methacrylate, 4-oxopentanal, styrene), and possible occupational carcinogens (benzene, formaldehyde, acetaldehyde) in air. Characteristics of particles and gases released by high-melt-temperature polymers during LFAM varied, which indicated the need for polymer-specific exposure and risk assessments. The presence of BPA and BPS on surfaces revealed a previously unrecognized source of dermal exposure for additive manufacturing workers using PC and PESU polymers.

16.
Front Public Health ; 8: 561740, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33072698

RESUMEN

Roasted coffee and many coffee flavorings emit volatile organic compounds (VOCs) including diacetyl and 2,3-pentanedione. Exposures to VOCs during roasting, packaging, grinding, and flavoring coffee can negatively impact the respiratory health of workers. Inhalational exposures to diacetyl and 2,3-pentanedione can cause obliterative bronchiolitis. This study summarizes exposures to and emissions of VOCs in 17 coffee roasting and packaging facilities that included 10 cafés. We collected 415 personal and 760 area full-shift, and 606 personal task-based air samples for diacetyl, 2,3-pentanedione, 2,3-hexanedione, and acetoin using silica gel tubes. We also collected 296 instantaneous activity and 312 instantaneous source air measurements for 18 VOCs using evacuated canisters. The highest personal full-shift exposure in part per billion (ppb) to diacetyl [geometric mean (GM) 21 ppb; 95th percentile (P95) 79 ppb] and 2,3-pentanedione (GM 15 ppb; P95 52 ppb) were measured for production workers in flavored coffee production areas. These workers also had the highest percentage of measurements above the NIOSH Recommended Exposure Limit (REL) for diacetyl (95%) and 2,3-pentanedione (77%). Personal exposures to diacetyl (GM 0.9 ppb; P95 6.0 ppb) and 2,3-pentanedione (GM 0.7 ppb; P95 4.4 ppb) were the lowest for non-production workers of facilities that did not flavor coffee. Job groups with the highest personal full-shift exposures to diacetyl and 2,3-pentanedione were flavoring workers (GM 34 and 38 ppb), packaging workers (GM 27 and 19 ppb) and grinder operator (GM 26 and 22 ppb), respectively, in flavored coffee facilities, and packaging workers (GM 8.0 and 4.4 ppb) and production workers (GM 6.3 and 4.6 ppb) in non-flavored coffee facilities. Baristas in cafés had mean full-shift exposures below the RELs (GM 4.1 ppb diacetyl; GM 4.6 ppb 2,3-pentanedione). The tasks, activities, and sources associated with flavoring in flavored coffee facilities and grinding in non-flavored coffee facilities, had some of the highest GM and P95 estimates for both diacetyl and 2,3-pentanedione. Controlling emissions at grinding machines and flavoring areas and isolating higher exposure areas (e.g., flavoring, grinding, and packaging areas) from the main production space and from administrative or non-production spaces is essential for maintaining exposure control.


Asunto(s)
Exposición Profesional , Compuestos Orgánicos Volátiles , Café/efectos adversos , Diacetil/efectos adversos , Humanos , Exposición Profesional/análisis , Pentanonas , Estados Unidos , Compuestos Orgánicos Volátiles/análisis
17.
J Occup Environ Hyg ; 4(6): 420-31, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17474032

RESUMEN

This study investigates two different methods (random effects model and 5th percentile) for determining the performance of three types of respiratory protective devices (elastomeric N95 respirators, N95 filtering-facepiece respirators, and surgical masks) during a simulated workplace test. This study recalculated the protection level of three types of respiratory protective devices using the random effects model, compared the two methods with each other and the APF of 10 for half-facepiece respirators, and determined the value of each of the fit test protocols in attaining the desired level of simulated workplace protection factor (SWPF). Twenty-five test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020 and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. Each of the six tests produced an SWPF. To determine the level of protection provided by the respiratory protective devices, a 90% lower confidence limit for the simulated workplace protection factor (SWPF(LCL90%)) and the 5th percentile of simulated workplace protection factor were computed. The 5th percentile method values could be up to seven times higher than the SWPF(LCL90%) values. Without fit testing, all half-facepiece N95 respirators had a 5th percentile of 4.6 and an SWPF(LCL90%) value of 2.7. N95 filtering-facepiece respirators as a class had values of 3.3 and 2.0, respectively, whereas N95 elastomeric respirators had values of 7.3 and 4.6, respectively. Surgical masks did not provide any protection, with values of 1.2 and 1.4, respectively. Passing either the Bitrex, saccharin, or Companion fit test resulted in the respirators providing the expected level of protection with 5th percentiles greater than or equal to 10 except when passing the Bitrex test with N95 filtering-facepiece respirators, which resulted in a 5th percentile of only 7.9. No substantial difference was seen between the three fit tests. All of the SWPF(LCL90%) values after passing a fit test were less than 10. The random model method provides a more conservative estimate of the protection provided by a respirator because it takes into account both between- and within-wearer variability.


Asunto(s)
Exposición Profesional/prevención & control , Dispositivos de Protección Respiratoria/normas , Adulto , Monitoreo del Ambiente/instrumentación , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Lugar de Trabajo
18.
J Occup Environ Hyg ; 3(9): 465-74, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16857645

RESUMEN

Respiratory protection is offered to American workers in a variety of ways to guard against potential inhalation hazards. Two of the most common ways are elastomeric N95 respirators and N95 filtering-facepiece respirators. Some in the health care industry feel that surgical masks provide an acceptable level of protection in certain situations against particular hazards. This study compared the performance of these types of respiratory protection during a simulated workplace test that measured both filter penetration and face-seal leakage. A panel of 25 test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020, and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. The results of these tests produced a simulated workplace protection factor (SWPF). The geometric mean (GM) and the 5th percentile values of the SWPFs were computed by category of respiratory protection using the six overall SWPF values. The level of protection provided by each of the three respiratory protection types was compared. The GM and 5th percentile SWPF values without fit testing were used for the comparison, as surgical masks were not intended to be fit tested. The GM values were 36 for elastomeric N95 respirators, 21 for N95 filtering-facepiece respirators, and 3 for surgical masks. An analysis of variance demonstrated a statistically significant difference between all three. Elastomeric N95 respirators had the highest 5th percentile SWPF of 7. N95 filtering-facepiece respirators and surgical masks had 5th percentile SWPFs of 3 and 1, respectively. A Fisher Exact Test revealed that the 5th percentile SWPFs for all three types of respiratory protection were statistically different. In addition, both qualitative (Bitrex and saccharin) and quantitative (N95-Companion) fit testing were performed on the N95 filtering- and elastomeric-facepiece respirators. It was found that passing a fit test generally improves the protection afforded the wearer. Passing the Bitrex fit test resulted in 5th percentile SWPFs of 11.1 and 7.9 for elastomeric and filtering-facepiece respirators, respectively. After passing the saccharin tests, the elastomeric respirators provided a 5th percentile of 11.7, and the filtering-facepiece respirators provided a 5th percentile of 11.0. The 5th percentiles after passing the N95-Companion were 13.0 for the elastomeric respirators and 20.5 for the filtering-facepiece respirators. The data supports fit testing as an essential element of a complete respiratory protection program.


Asunto(s)
Dispositivos de Protección Respiratoria/normas , Adulto , Análisis de Falla de Equipo , Femenino , Humanos , Exposición por Inhalación/prevención & control , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Exposición Profesional/prevención & control
19.
J Occup Environ Hyg ; 3(1): 44-52, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16485349

RESUMEN

Three fit test methods (Bitrex, saccharin, and TSI PortaCount Plus with the N95-Companion) were evaluated for their ability to identify wearers of respirators that do not provide adequate protection during a simulated workplace test. Thirty models of NIOSH-certified N95 half-facepiece respirators (15 filtering-facepiece models and 15 elastomeric models) were tested by a panel of 25 subjects using each of the three fit testing methods. Fit testing results were compared to 5th percentiles of simulated workplace protection factors. Alpha errors (the chance of failing a fit test in error) for all 30 respirators were 71% for the Bitrex method, 68% for the saccharin method, and 40% for the Companion method. Beta errors (the chance of passing a fit test in error) for all 30 respirator models combined were 8% for the Bitrex method, 8% for the saccharin method, and 9% for the Companion method. The three fit test methods had different error rates when assessed with filtering facepieces and when assessed with elastomeric respirators. For example, beta errors for the three fit test methods assessed with the 15 filtering facepiece respirators were < or = 5% but ranged from 14% to 21% when assessed with the 15 elastomeric respirators. To predict what happens in a realistic fit testing program, the data were also used to estimate the alpha and beta errors for a simulated respiratory protection program in which a wearer is given up to three trials with one respirator model to pass a fit test before moving onto another model. A subject passing with any of the three methods was considered to have passed the fit test program. The alpha and beta errors for the fit testing in this simulated respiratory protection program were 29% and 19%, respectively. Thus, it is estimated, under the conditions of the simulation, that roughly one in three respirator wearers receiving the expected reduction in exposure (with a particular model) will fail to pass (with that particular model), and that roughly one in five wearers receiving less reduction in exposure than expected will pass the fit testing program in error.


Asunto(s)
Ensayo de Materiales , Dispositivos de Protección Respiratoria/normas , Adulto , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , National Institute for Occupational Safety and Health, U.S. , Exposición Profesional/prevención & control , Proyectos de Investigación , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA