Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Biophys J ; 122(9): 1586-1599, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37002604

RESUMEN

Segmenting cells within cellular aggregates in 3D is a growing challenge in cell biology due to improvements in capacity and accuracy of microscopy techniques. Here, we describe a pipeline to segment images of cell aggregates in 3D. The pipeline combines neural network segmentations with active meshes. We apply our segmentation method to cultured mouse mammary gland organoids imaged over 24 h with oblique plane microscopy, a high-throughput light-sheet fluorescence microscopy technique. We show that our method can also be applied to images of mouse embryonic stem cells imaged with a spinning disc microscope. We segment individual cells based on nuclei and cell membrane fluorescent markers, and track cells over time. We describe metrics to quantify the quality of the automated segmentation. Our segmentation pipeline involves a Fiji plugin that implements active mesh deformation and allows a user to create training data, automatically obtain segmentation meshes from original image data or neural network prediction, and manually curate segmentation data to identify and correct mistakes. Our active meshes-based approach facilitates segmentation postprocessing, correction, and integration with neural network prediction.


Asunto(s)
Núcleo Celular , Redes Neurales de la Computación , Animales , Ratones , Microscopía Fluorescente/métodos , Procesamiento de Imagen Asistido por Computador/métodos
2.
Appl Opt ; 62(28): 7431-7440, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37855511

RESUMEN

The technique of remote refocusing is used in optical microscopy to provide rapid axial scanning without mechanically perturbing the sample and in techniques such as oblique plane microscopy that build on remote refocusing to image a tilted plane within the sample. The magnification between the pupils of the primary (O1) and secondary (O2) microscope objectives of the remote-refocusing system has been shown previously by Mohanan and Corbett [J. Microsc.288, 95 (2022)JMICAR0022-272010.1111/jmi.12991] to be crucial in obtaining the broadest possible remote-refocusing range. In this work, we performed an initial alignment of a remote-refocusing system and then studied the effect of axial misalignments of O1 and O2, axial misalignment of the primary tube lens (TL1) relative to the secondary tube lens (TL2), lateral misalignments of TL2, and changes in the focal length of  TL2. For each instance of the setup, we measured the mean point spread function F W H M xy of 100 nm fluorescent beads and the normalized bead integrated fluorescence signal, and we calculated the axial and lateral distortion of the system; all of these quantities were mapped over the remote-refocusing range and as a function of lateral image position. This allowed us to estimate the volume over which diffraction-limited performance is achieved and how this changes with the alignment of the system.

3.
J Biol Chem ; 296: 100133, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33268378

RESUMEN

Receptors for the peptide hormones glucagon-like peptide-1 (GLP-1R), glucose-dependent insulinotropic polypeptide (GIPR), and glucagon (GCGR) are important regulators of insulin secretion and energy metabolism. GLP-1R agonists have been successfully deployed for the treatment of type 2 diabetes, but it has been suggested that their efficacy is limited by target receptor desensitization and downregulation due to recruitment of ß-arrestins. Indeed, recently described GLP-1R agonists with reduced ß-arrestin-2 recruitment have delivered promising results in preclinical and clinical studies. We therefore aimed to determine if the same phenomenon could apply to the closely related GIPR and GCGR. In HEK293 cells depleted of both ß-arrestin isoforms the duration of G protein-dependent cAMP/PKA signaling was increased in response to the endogenous ligand for each receptor. Moreover, in wildtype cells, "biased" GLP-1, GCG, and GIP analogs with selective reductions in ß-arrestin-2 recruitment led to reduced receptor endocytosis and increased insulin secretion over a prolonged stimulation period, although the latter effect was only seen at high agonist concentrations. Biased GCG analogs increased the duration of cAMP signaling, but this did not lead to increased glucose output from hepatocytes. Our study provides a rationale for the development of GLP-1R, GIPR, and GCGR agonists with reduced ß-arrestin recruitment, but further work is needed to maximally exploit this strategy for therapeutic purposes.


Asunto(s)
AMP Cíclico/metabolismo , Polipéptido Inhibidor Gástrico/metabolismo , Péptido 1 Similar al Glucagón/metabolismo , Receptor del Péptido 1 Similar al Glucagón/metabolismo , Incretinas/farmacología , Receptores de la Hormona Gastrointestinal/metabolismo , beta-Arrestinas/metabolismo , Animales , Polipéptido Inhibidor Gástrico/genética , Glucagón/metabolismo , Péptido 1 Similar al Glucagón/genética , Receptor del Péptido 1 Similar al Glucagón/genética , Células HEK293 , Humanos , Secreción de Insulina , Ligandos , Ratones , Ratones Endogámicos C57BL , Receptores de la Hormona Gastrointestinal/genética , Transducción de Señal , beta-Arrestinas/genética
4.
Opt Express ; 30(3): 4274-4287, 2022 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-35209667

RESUMEN

The remote-refocusing approach of Botcherby et al. [Opt. Lett.32, 2007 (2007)10.1364/OL.32.002007] has been applied widely to 2D and 3D fluorescence microscopes to enable rapid refocusing of the optical system without mechanically perturbing the sample. In order for this approach to operate correctly, it requires that the overall magnification of the first two microscope systems matches the ratio of the refractive indices in sample and intermedia image spaces. However, commercially available tube lenses are not always suitable to produce the desired overall magnification. Therefore, a practical approach to produce tube lenses with low expense and diffraction-limited performance is required. Tube lenses can be formed using a pair of stock achromatic doublets, however, selecting appropriate pairs of achromatic doublets from stock optics is a time-consuming process, as many combinations can be considered. In this paper, we present two software packages (Catalogue Generator and Doublet Selector) developed in MATLAB that use the application programming interface (ZOS-API) to the Zemax OpticStudio optical design software to realise an automatic search of stock achromatic doublets to produce microscope tube lenses with a specified focal length, entrance pupil diameter and maximum design field angle. An algorithm to optimise principal plane positions in versions of OpticStudio before 20.2 was also introduced to enable the use of older software versions. To evaluate the performance of Catalogue Generator and Doublet Selector, we used them to generate ten tube lens designs. All of the software-produced tube lenses have a better optical performance than those using manually selected pairs of stock doublets lenses.

5.
Opt Express ; 26(3): 3661-3673, 2018 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-29401893

RESUMEN

This paper reports the development, modelling and application of a semi-random multicore fibre (MCF) design for adaptive multiphoton endoscopy. The MCF was constructed from 55 sub-units, each comprising 7 single mode cores, in a hexagonally close-packed lattice where each sub-unit had a random angular orientation. The resulting fibre had 385 single mode cores and was double-clad for proximal detection of multiphoton excited fluorescence. The random orientation of each sub-unit in the fibre reduces the symmetry of the positions of the cores in the MCF, reducing the intensity of higher diffracted orders away from the central focal spot formed at the distal tip of the fibre and increasing the maximum size of object that can be imaged. The performance of the MCF was demonstrated by imaging fluorescently labelled beads with both distal and proximal fluorescence detection and pollen grains with distal fluorescence detection. We estimate that the number of independent resolution elements in the final image - measured as the half-maximum area of the two-photon point spread function divided by the area imaged - to be ~3200.


Asunto(s)
Endoscopios , Endoscopía/instrumentación , Microscopía de Fluorescencia por Excitación Multifotónica , Fibras Ópticas , Diseño de Equipo , Microesferas , Polen
6.
Opt Express ; 24(19): 21474-84, 2016 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-27661887

RESUMEN

This paper demonstrates multiphoton excited fluorescence imaging through a polarisation maintaining multicore fiber (PM-MCF) while the fiber is dynamically deformed using all-proximal detection. Single-shot proximal measurement of the relative optical path lengths of all the cores of the PM-MCF in double pass is achieved using a Mach-Zehnder interferometer read out by a scientific CMOS camera operating at 416 Hz. A non-linear least squares fitting procedure is then employed to determine the deformation-induced lateral shift of the excitation spot at the distal tip of the PM-MCF. An experimental validation of this approach is presented that compares the proximally measured deformation-induced lateral shift in focal spot position to an independent distally measured ground truth. The proximal measurement of deformation-induced shift in focal spot position is applied to correct for deformation-induced shifts in focal spot position during raster-scanning multiphoton excited fluorescence imaging.

7.
Sensors (Basel) ; 16(8)2016 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-27548185

RESUMEN

We describe an approach to non-invasively map spatiotemporal biochemical and physiological changes in 3D cell culture using Forster Resonance Energy Transfer (FRET) biosensors expressed in tumour spheroids. In particular, we present an improved Adenosine Monophosphate (AMP) Activated Protein Kinase (AMPK) FRET biosensor, mTurquoise2 AMPK Activity Reporter (T2AMPKAR), for fluorescence lifetime imaging (FLIM) readouts that we have evaluated in 2D and 3D cultures. Our results in 2D cell culture indicate that replacing the FRET donor, enhanced Cyan Fluorescent Protein (ECFP), in the original FRET biosensor, AMPK activity reporter (AMPKAR), with mTurquoise2 (mTq2FP), increases the dynamic range of the response to activation of AMPK, as demonstrated using the direct AMPK activator, 991. We demonstrated 3D FLIM of this T2AMPKAR FRET biosensor expressed in tumour spheroids using two-photon excitation.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas de Cultivo de Célula , Imagen Molecular/métodos , Proteínas Quinasas/aislamiento & purificación , Quinasas de la Proteína-Quinasa Activada por el AMP , Transferencia Resonante de Energía de Fluorescencia/métodos , Proteínas Fluorescentes Verdes/química , Humanos , Imagen Óptica/métodos , Esferoides Celulares/citología
8.
J Fluoresc ; 25(5): 1169-82, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26063535

RESUMEN

A correction is proposed to the Delta function convolution method (DFCM) for fitting a multiexponential decay model to time-resolved fluorescence decay data using a monoexponential reference fluorophore. A theoretical analysis of the discretised DFCM multiexponential decay function shows the presence an extra exponential decay term with the same lifetime as the reference fluorophore that we denote as the residual reference component. This extra decay component arises as a result of the discretised convolution of one of the two terms in the modified model function required by the DFCM. The effect of the residual reference component becomes more pronounced when the fluorescence lifetime of the reference is longer than all of the individual components of the specimen under inspection and when the temporal sampling interval is not negligible compared to the quantity (τR (-1) - τ(-1))(-1), where τR and τ are the fluorescence lifetimes of the reference and the specimen respectively. It is shown that the unwanted residual reference component results in systematic errors when fitting simulated data and that these errors are not present when the proposed correction is applied. The correction is also verified using real data obtained from experiment.


Asunto(s)
Colorantes Fluorescentes/química , Modelos Teóricos , Espectrometría de Fluorescencia/normas , Análisis de los Mínimos Cuadrados , Dinámicas no Lineales , Estándares de Referencia
9.
Int J Mol Sci ; 16(7): 14695-716, 2015 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-26133241

RESUMEN

Multiplexed imaging of Förster Resonance Energy Transfer (FRET)-based biosensors potentially presents a powerful approach to monitoring the spatio-temporal correlation of signalling pathways within a single live cell. Here, we discuss the potential of homo-FRET based biosensors to facilitate multiplexed imaging. We demonstrate that the homo-FRET between pleckstrin homology domains of Akt (Akt-PH) labelled with mCherry may be used to monitor 3'-phosphoinositide accumulation in live cells and show how global analysis of time resolved fluorescence anisotropy measurements can be used to quantify this accumulation. We further present multiplexed imaging readouts of calcium concentration, using fluorescence lifetime measurements of TN-L15-a CFP/YFP based hetero-FRET calcium biosensor-with 3'-phosphoinositide accumulation.


Asunto(s)
Técnicas Biosensibles/métodos , Transferencia Resonante de Energía de Fluorescencia/métodos , Transducción de Señal , Animales , Anisotropía , Calcio/metabolismo , Línea Celular , Transferencia Resonante de Energía de Fluorescencia/instrumentación , Proteínas Fluorescentes Verdes/genética , Proteínas Fluorescentes Verdes/metabolismo , Ratones , Fosfatidilinositoles/metabolismo , Proteínas Proto-Oncogénicas c-akt/metabolismo
10.
Ultrasound Med Biol ; 50(7): 1045-1057, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38702285

RESUMEN

OBJECTIVE: This study aimed to realise 3-D super-resolution ultrasound imaging transcutaneously with a row-column array which has far fewer independent electronic channels and a wider field of view than typical fully addressed 2-D matrix arrays. The in vivo image quality of the row-column array is generally poor, particularly when imaging non-invasively. This study aimed to develop a suite of image formation and post-processing methods to improve image quality and demonstrate the feasibility of ultrasound localisation microscopy using a row-column array, transcutaneously on a rabbit model and in a human. METHODS: To achieve this, a processing pipeline was developed which included a new type of rolling window image reconstruction, which integrated a row-column array specific coherence-based beamforming technique with acoustic sub-aperture processing. This and other processing steps reduced the 'secondary' lobe artefacts, and noise and increased the effective frame rate, thereby enabling ultrasound localisation images to be produced. RESULTS: Using an in vitro cross tube, it was found that the procedure reduced the percentage of 'false' locations from ∼26% to ∼15% compared to orthogonal plane wave compounding. Additionally, it was found that the noise could be reduced by ∼7 dB and the effective frame rate was increased to over 4000 fps. In vivo, ultrasound localisation microscopy was used to produce images non-invasively of a rabbit kidney and a human thyroid. CONCLUSION: It has been demonstrated that the proposed methods using a row-column array can produce large field of view super-resolution microvascular images in vivo and in a human non-invasively.


Asunto(s)
Imagenología Tridimensional , Ultrasonografía , Conejos , Animales , Humanos , Ultrasonografía/métodos , Imagenología Tridimensional/métodos , Diseño de Equipo , Fantasmas de Imagen , Piel/diagnóstico por imagen , Estudios de Factibilidad
11.
Cell Rep ; 43(5): 114016, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38636520

RESUMEN

How cancer cells determine their shape in response to three-dimensional (3D) geometric and mechanical cues is unclear. We develop an approach to quantify the 3D cell shape of over 60,000 melanoma cells in collagen hydrogels using high-throughput stage-scanning oblique plane microscopy (ssOPM). We identify stereotypic and environmentally dependent changes in shape and protrusivity depending on whether a cell is proximal to a flat and rigid surface or is embedded in a soft environment. Environmental sensitivity metrics calculated for small molecules and gene knockdowns identify interactions between the environment and cellular factors that are important for morphogenesis. We show that the Rho guanine nucleotide exchange factor (RhoGEF) TIAM2 contributes to shape determination in environmentally independent ways but that non-muscle myosin II, microtubules, and the RhoGEF FARP1 regulate shape in ways dependent on the microenvironment. Thus, changes in cancer cell shape in response to 3D geometric and mechanical cues are modulated in both an environmentally dependent and independent fashion.


Asunto(s)
Forma de la Célula , Factores de Intercambio de Guanina Nucleótido , Humanos , Factores de Intercambio de Guanina Nucleótido/metabolismo , Factores de Intercambio de Guanina Nucleótido/genética , Línea Celular Tumoral , Microtúbulos/metabolismo , Miosina Tipo II/metabolismo , Factores de Intercambio de Guanina Nucleótido Rho/metabolismo , Factores de Intercambio de Guanina Nucleótido Rho/genética , Melanoma/patología , Melanoma/metabolismo
12.
IEEE Trans Med Imaging ; 43(8): 2970-2987, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38607705

RESUMEN

With the widespread interest and uptake of super-resolution ultrasound (SRUS) through localization and tracking of microbubbles, also known as ultrasound localization microscopy (ULM), many localization and tracking algorithms have been developed. ULM can image many centimeters into tissue in-vivo and track microvascular flow non-invasively with sub-diffraction resolution. In a significant community effort, we organized a challenge, Ultrasound Localization and TRacking Algorithms for Super-Resolution (ULTRA-SR). The aims of this paper are threefold: to describe the challenge organization, data generation, and winning algorithms; to present the metrics and methods for evaluating challenge entrants; and to report results and findings of the evaluation. Realistic ultrasound datasets containing microvascular flow for different clinical ultrasound frequencies were simulated, using vascular flow physics, acoustic field simulation and nonlinear bubble dynamics simulation. Based on these datasets, 38 submissions from 24 research groups were evaluated against ground truth using an evaluation framework with six metrics, three for localization and three for tracking. In-vivo mouse brain and human lymph node data were also provided, and performance assessed by an expert panel. Winning algorithms are described and discussed. The publicly available data with ground truth and the defined metrics for both localization and tracking present a valuable resource for researchers to benchmark algorithms and software, identify optimized methods/software for their data, and provide insight into the current limits of the field. In conclusion, Ultra-SR challenge has provided benchmarking data and tools as well as direct comparison and insights for a number of the state-of-the art localization and tracking algorithms.


Asunto(s)
Algoritmos , Encéfalo , Procesamiento de Imagen Asistido por Computador , Ultrasonografía , Ultrasonografía/métodos , Ratones , Animales , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo/diagnóstico por imagen , Ganglios Linfáticos/diagnóstico por imagen , Microburbujas
13.
Front Physiol ; 14: 1079727, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36866170

RESUMEN

Introduction: Reduced synchrony of calcium release and t-tubule structure organization in individual cardiomyocytes has been linked to loss of contractile strength and arrhythmia. Compared to confocal scanning techniques widely used for imaging calcium dynamics in cardiac muscle cells, light-sheet fluorescence microscopy enables fast acquisition of a 2D plane in the sample with low phototoxicity. Methods: A custom light-sheet fluorescence microscope was used to achieve dual-channel 2D timelapse imaging of calcium and the sarcolemma, enabling calcium sparks and transients in left and right ventricle cardiomyocytes to be correlated with the cell microstructure. Imaging electrically stimulated dual-labelled cardiomyocytes immobilized with para-nitroblebbistatin, a non-phototoxic, low fluorescence contraction uncoupler, with sub-micron resolution at 395 fps over a 38 µm × 170 µm FOV allowed characterization of calcium spark morphology and 2D mapping of the calcium transient time-to-half-maximum across the cell. Results: Blinded analysis of the data revealed sparks with greater amplitude in left ventricle myocytes. The time for the calcium transient to reach half-maximum amplitude in the central part of the cell was found to be, on average, 2 ms shorter than at the cell ends. Sparks co-localized with t-tubules were found to have significantly longer duration, larger area and spark mass than those further away from t-tubules. Conclusion: The high spatiotemporal resolution of the microscope and automated image-analysis enabled detailed 2D mapping and quantification of calcium dynamics of n = 60 myocytes, with the findings demonstrating multi-level spatial variation of calcium dynamics across the cell, supporting the dependence of synchrony and characteristics of calcium release on the underlying t-tubule structure.

14.
Methods Mol Biol ; 2483: 33-59, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35286668

RESUMEN

The newly generated software plugin MultiFRET allows for real-time measurements of multiplexed fluorescent biosensors in a near high-throughput fashion. Here we describe a detailed protocol for setup and use of this software for any purpose requiring instant feedback during fluorescence measurement experiments. We further describe its non-primary features including beam splitter misalignment correction, custom calculations through input of simple equations typed in a .txt format, customizable Excel output, and offline bulk analysis of image stacks. Finally, we supply a usage example of a cAMP measurement in cultured rat neonatal cardiomyocytes.


Asunto(s)
Técnicas Biosensibles , Transferencia Resonante de Energía de Fluorescencia , Animales , Técnicas Biosensibles/métodos , Transferencia Resonante de Energía de Fluorescencia/métodos , Miocitos Cardíacos , Ratas , Programas Informáticos
15.
Opt Express ; 19(15): 13839-47, 2011 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-21934745

RESUMEN

Oblique plane microscopy (OPM) is a light sheet microscopy technique that uses a single high numerical aperture microscope objective to both illuminate a tilted plane within the specimen and to obtain an image of the tilted illuminated plane. In this paper, we present a new OPM configuration that enables both the illumination and detection focal planes to be swept simultaneously and remotely through the sample volume, enabling high speed volumetric imaging. We demonstrate the high speed imaging capabilities of the system by imaging calcium dynamics in cardiac myocytes in 2D at 926 frames per second and in 3D at 21 volumes per second. In the future, higher frame rate CCD cameras will enable volumetric imaging at much greater rates, leading to new capabilities to study dynamic events in cells at high speeds in two and three dimensions.


Asunto(s)
Imagenología Tridimensional/métodos , Microscopía Fluorescente/métodos , Miocitos Cardíacos/citología , Compuestos de Anilina/metabolismo , Animales , Núcleo Celular/metabolismo , Ratas , Factores de Tiempo , Xantenos/metabolismo
16.
Opt Express ; 19(8): 7299-311, 2011 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-21503041

RESUMEN

Ultrasound-modulated optical tomography (UOT) combines optical contrast with ultrasound spatial resolution and has great potential for soft tissue functional imaging. One current problem with this technique is the weak optical modulation signal, primarily due to strong optical scattering in diffuse media and minimal acoustically induced modulation. The acoustic radiation force (ARF) can create large particle displacements in tissue and has been shown to be able to improve optical modulation signals. However, shear wave propagation induced by the ARF can be a significant source of nonlocal optical modulation which may reduce UOT spatial resolution and contrast. In this paper, the time evolution of shear waves was examined on tissue mimicking-phantoms exposed to 5 MHz ultrasound and 532 nm optical radiation and measured with a CCD camera. It has been demonstrated that by generating an ARF with an acoustic burst and adjusting both the timing and the exposure time of the CCD measurement, optical contrast and spatial resolution can be improved by ~110% and ~40% respectively when using the ARF rather than 5 MHz ultrasound alone. Furthermore, it has been demonstrated that this technique simultaneously detects both optical and mechanical contrast in the medium and the optical and mechanical contrast can be distinguished by adjusting the CCD exposure time.


Asunto(s)
Óptica y Fotónica , Tomografía Óptica/instrumentación , Ultrasonido , Acústica/instrumentación , Medios de Contraste , Diseño de Equipo , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Rayos Láser , Ensayo de Materiales , Fantasmas de Imagen , Tomografía Óptica/métodos
17.
Opt Express ; 19(15): 13848-61, 2011 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-21934746

RESUMEN

When performing multiphoton fluorescence lifetime imaging in multiple spectral emission channels, an instrument response function must be acquired in each channel if accurate measurements of complex fluorescence decays are to be performed. Although this can be achieved using the reference reconvolution technique, it is difficult to identify suitable fluorophores with a mono-exponential fluorescence decay across a broad emission spectrum. We present a solution to this problem by measuring the IRF using the ultrafast luminescence from gold nanorods. We show that ultrafast gold nanorod luminescence allows the IRF to be directly obtained in multiple spectral channels simultaneously across a wide spectral range. We validate this approach by presenting an analysis of multispectral autofluorescence FLIM data obtained from human skin ex vivo.


Asunto(s)
Oro/química , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Luminiscencia , Microscopía de Fluorescencia por Excitación Multifotónica/instrumentación , Microscopía de Fluorescencia por Excitación Multifotónica/métodos , Humanos , Técnicas In Vitro , Nanotubos , Espectrometría de Fluorescencia , Factores de Tiempo
18.
Opt Lett ; 36(9): 1707-9, 2011 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-21540976

RESUMEN

We present an approach to laser scanning endomicroscopy that requires no moving parts and can be implemented with no distal scanners or optics, permitting extremely compact endoscopic probes to be developed. Our approach utilizes a spatial light modulator to correct for phase variations across a fiber imaging bundle and to encode for arbitrary wavefronts at the distal end of the fiber bundle. Thus, it is possible to realize both focusing and beam scanning at the output of the fiber bundle with no distal components. We present proof of principle results to illustrate three-dimensional scanning of the focal spot and exemplar images of a United States Air Force resolution test chart.


Asunto(s)
Microscopía Confocal/métodos , Imagenología Tridimensional , Luz , Fenómenos Ópticos
19.
J Cell Biol ; 174(1): 153-61, 2006 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-16801390

RESUMEN

We report the supramolecular organization of killer Ig-like receptor (KIR) phosphorylation using a technique applicable to imaging phosphorylation of any green fluorescent protein-tagged receptor at an intercellular contact or immune synapse. Specifically, we use fluorescence lifetime imaging (FLIM) to report Förster resonance energy transfer (FRET) between GFP-tagged KIR2DL1 and a Cy3-tagged generic anti-phosphotyrosine monoclonal antibody. Visualization of KIR phosphorylation in natural killer (NK) cells contacting target cells expressing cognate major histocompatibility complex class I proteins revealed that inhibitory signaling is spatially restricted to the immune synapse. This explains how NK cells respond appropriately when simultaneously surveying susceptible and resistant target cells. More surprising, phosphorylated KIR was confined to microclusters within the aggregate of KIR, contrary to an expected homogeneous distribution of KIR signaling across the immune synapse. Also, yellow fluorescent protein-tagged Lck, a kinase important for KIR phosphorylation, accumulated in a multifocal distribution at inhibitory synapses. Spatial confinement of receptor phosphorylation within the immune synapse may be critical to how activating and inhibitory signals are integrated in NK cells.


Asunto(s)
Estructuras de la Membrana Celular/metabolismo , Uniones Intercelulares/inmunología , Células Asesinas Naturales/metabolismo , Receptores Inmunológicos/metabolismo , Transducción de Señal/inmunología , Línea Celular , Estructuras de la Membrana Celular/ultraestructura , Transferencia Resonante de Energía de Fluorescencia , Humanos , Uniones Intercelulares/ultraestructura , Células Asesinas Naturales/efectos de los fármacos , Células Asesinas Naturales/inmunología , Fosforilación , Pirimidinas/farmacología , Agregación de Receptores/inmunología , Receptores Inmunológicos/antagonistas & inhibidores , Receptores KIR , Receptores KIR2DL1 , Transducción de Señal/efectos de los fármacos , Familia-src Quinasas/antagonistas & inhibidores , Familia-src Quinasas/metabolismo
20.
Chemphyschem ; 12(3): 609-26, 2011 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-21337485

RESUMEN

A fluorescence lifetime imaging (FLIM) technology platform intended to read out changes in Förster resonance energy transfer (FRET) efficiency is presented for the study of protein interactions across the drug-discovery pipeline. FLIM provides a robust, inherently ratiometric imaging modality for drug discovery that could allow the same sensor constructs to be translated from automated cell-based assays through small transparent organisms such as zebrafish to mammals. To this end, an automated FLIM multiwell-plate reader is described for high content analysis of fixed and live cells, tomographic FLIM in zebrafish and FLIM FRET of live cells via confocal endomicroscopy. For cell-based assays, an exemplar application reading out protein aggregation using FLIM FRET is presented, and the potential for multiple simultaneous FLIM (FRET) readouts in microscopy is illustrated.


Asunto(s)
Transferencia Resonante de Energía de Fluorescencia/métodos , Proteínas/análisis , Línea Celular , Evaluación Preclínica de Medicamentos , Colorantes Fluorescentes/química , Proteínas Fluorescentes Verdes/química , Humanos , Microscopía Fluorescente , Unión Proteica , Rodaminas/química , Productos del Gen gag del Virus de la Inmunodeficiencia Humana/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA