Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 146(5): 383-397, 2022 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-35722876

RESUMEN

BACKGROUND: Cerebral microbleeds (CMBs) have been observed in healthy elderly people undergoing systematic brain magnetic resonance imaging. The potential role of acute triggers on the appearance of CMBs remains unknown. We aimed to describe the incidence of new CMBs after transcatheter aortic valve replacement (TAVR) and to identify clinical and procedural factors associated with new CMBs including hemostatic measures and anticoagulation management. METHODS: We evaluated a prospective cohort of patients with symptomatic aortic stenosis referred for TAVR for CMBs (METHYSTROKE [Identification of Epigenetic Risk Factors for Ischemic Complication During the TAVR Procedure in the Elderly]). Standardized neurologic assessment, brain magnetic resonance imaging, and analysis of hemostatic measures including von Willebrand factor were performed before and after TAVR. Numbers and location of microbleeds on preprocedural magnetic resonance imaging and of new microbleeds on postprocedural magnetic resonance imaging were reported by 2 independent neuroradiologists blinded to clinical data. Measures associated with new microbleeds and postprocedural outcome including neurologic functional outcome at 6 months were also examined. RESULTS: A total of 84 patients (47% men, 80.9±5.7 years of age) were included. On preprocedural magnetic resonance imaging, 22 patients (26% [95% CI, 17%-37%]) had at least 1 microbleed. After TAVR, new microbleeds were observed in 19 (23% [95% CI, 14%-33%]) patients. The occurrence of new microbleeds was independent of the presence of microbleeds at baseline and of diffusion-weighted imaging hypersignals. In univariable analysis, a previous history of bleeding (P=0.01), a higher total dose of heparin (P=0.02), a prolonged procedure (P=0.03), absence of protamine reversion (P=0.04), higher final activated partial thromboplastin time (P=0.05), lower final von Willebrand factor high-molecular-weight:multimer ratio (P=0.007), and lower final closure time with adenosine-diphosphate (P=0.02) were associated with the occurrence of new postprocedural microbleeds. In multivariable analysis, a prolonged procedure (odds ratio, 1.22 [95% CI, 1.03-1.73] for every 5 minutes of fluoroscopy time; P=0.02) and postprocedural acquired von Willebrand factor defect (odds ratio, 1.42 [95% CI, 1.08-1.89] for every lower 0.1 unit of high-molecular-weight:multimer ratio; P=0.004) were independently associated with the occurrence of new postprocedural microbleeds. New CMBs were not associated with changes in neurologic functional outcome or quality of life at 6 months. CONCLUSIONS: One out of 4 patients undergoing TAVR has CMBs before the procedure and 1 out of 4 patients develops new CMBs. Procedural or antithrombotic management and persistence of acquired von Willebrand factor defect were associated with the occurrence of new CMBs. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02972008.


Asunto(s)
Hemorragia Cerebral , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/epidemiología , Hemorragia Cerebral/etiología , Femenino , Fluoroscopía , Hemostáticos , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Factor de von Willebrand
2.
N Engl J Med ; 375(4): 335-44, 2016 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-27464202

RESUMEN

BACKGROUND: Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. METHODS: We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. RESULTS: After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. CONCLUSIONS: The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.).


Asunto(s)
Adenosina Difosfato/sangre , Insuficiencia de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/diagnóstico , Reemplazo de la Válvula Aórtica Transcatéter , Factor de von Willebrand/análisis , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/mortalidad , Biomarcadores/sangre , Femenino , Hemostasis/fisiología , Humanos , Masculino , Análisis Multivariante , Pruebas en el Punto de Atención , Complicaciones Posoperatorias/sangre , Curva ROC , Sensibilidad y Especificidad , Factor de von Willebrand/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA