Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Vasc Interv Radiol ; 34(3): 466-473, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36414114

RESUMEN

PURPOSE: To assess patient and provider satisfaction with interventional radiology (IR) outpatient telehealth and in-person clinic. MATERIALS AND METHODS: This institutional review board-approved study analyzed patient satisfaction with clinic via survey after an IR outpatient telehealth or in-person visit. A physician telehealth experience survey was completed by 8 IR physicians. RESULTS: During the initial survey period, 44 (83%) of 53 patients completed a survey via telephone compared with 37 (23%) of 158 patients who were offered an electronic survey during the second survey period. Of 81 respondents, 18 (22%) were in-person and 63 (78%) were via telehealth. Of the respondents, nearly all patients (97%) in the telehealth group reported satisfaction with their telehealth clinic visit, with similar rates of high patient satisfaction between in-person and telehealth visits (P = .51). Most patients (98%) in the telehealth group strongly agreed that their physician's recommendations were clear in the telehealth visit and that their visit was private, similar to in-person visits (P = .13). A telehealth visit saved time for all patients (100%), with 78% reporting >1 hour of time-saving. All IR physicians (n = 8) reported greater efficiency with telehealth clinic than with in-person clinic and that follow-up patterns would change if telehealth was available. However, all providers (100%) found telephone visits less satisfying than in-person visits, with video visits being either equally satisfying (71%) or less satisfying (29%). CONCLUSIONS: Patient satisfaction with the in-person and telehealth outpatient IR clinic was high, with patients and providers reporting time-saving and greater efficiency with telehealth, suggesting that telehealth should remain an important component of outpatient IR clinic care.


Asunto(s)
Radiología Intervencionista , Telemedicina , Humanos , Satisfacción del Paciente , Atención Ambulatoria , Pacientes Ambulatorios
2.
J Vasc Interv Radiol ; 32(2): 226-234, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33339678

RESUMEN

PURPOSE: To prospectively validate electromagnetic hand motion tracking in interventional radiology to detect differences in operator experience using simulation. METHODS: Sheath task: Six attending interventional radiologists (experts) and 6 radiology trainees (trainees) placed a wire through a sheath and performed a "pin-pull" maneuver, while an electromagnetic motion detection system recorded the hand motion. Radial task: Eight experts and 12 trainees performed palpatory radial artery access task on a radial access simulator. The trainees repeated the task with the nondominant hand. The experts were classified by their most frequent radial artery access technique as having either palpatory, ultrasound, or overall limited experience. The time, path length, and number of movements were calculated. Mann-Whitney U tests were used to compare the groups, and P < .05 was considered significant. RESULTS: Sheath task: The experts took less time, had shorter path lengths, and used fewer movements than the trainees (11.7 seconds ± 3.3 vs 19.7 seconds ± 6.5, P < .01; 1.1 m ± 0.3 vs 1.4 m ± 0.4, P < .01; and 19.5 movements ± 8.5 vs 31.0 movements ± 8.0, P < .01, respectively). Radial task: The experts took less time, had shorter path lengths, and used fewer movements than the trainees (24.2 seconds ± 10.6 vs 33.1 seconds ± 16.9, P < .01; 2.0 m ± 0.5 vs 3.0 m ± 1.9, P < .001; and 36.5 movements ± 15.0 vs 54.5 movements ± 28.0, P < .001, respectively). The trainees had a shorter path length for their dominant hand than their nondominant hand (3.0 m ± 1.9 vs 3.5 m ± 1.9, P < .05). The expert palpatory group had a shorter path length than the ultrasound and limited experience groups (1.8 m ± 0.4 vs 2.0 m ± 0.4 and 2.3 m ± 1.2, respectively, P < .05). CONCLUSIONS: Electromagnetic hand motion tracking can differentiate between the expert and trainee operators for simulated interventional tasks.


Asunto(s)
Cateterismo Periférico , Competencia Clínica , Fenómenos Electromagnéticos , Mano , Destreza Motora , Arteria Radial , Radiografía Intervencional , Radiólogos , Fenómenos Biomecánicos , Estudios de Factibilidad , Humanos , Proyectos Piloto , Estudios Prospectivos , Punciones , Factores de Tiempo
3.
Neuroimage ; 84: 585-604, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24055704

RESUMEN

The present study developed a fast MEG source imaging technique based on Fast Vector-based Spatio-Temporal Analysis using a L1-minimum-norm (Fast-VESTAL) and then used the method to obtain the source amplitude images of resting-state magnetoencephalography (MEG) signals for different frequency bands. The Fast-VESTAL technique consists of two steps. First, L1-minimum-norm MEG source images were obtained for the dominant spatial modes of sensor-waveform covariance matrix. Next, accurate source time-courses with millisecond temporal resolution were obtained using an inverse operator constructed from the spatial source images of Step 1. Using simulations, Fast-VESTAL's performance was assessed for its 1) ability to localize multiple correlated sources; 2) ability to faithfully recover source time-courses; 3) robustness to different SNR conditions including SNR with negative dB levels; 4) capability to handle correlated brain noise; and 5) statistical maps of MEG source images. An objective pre-whitening method was also developed and integrated with Fast-VESTAL to remove correlated brain noise. Fast-VESTAL's performance was then examined in the analysis of human median-nerve MEG responses. The results demonstrated that this method easily distinguished sources in the entire somatosensory network. Next, Fast-VESTAL was applied to obtain the first whole-head MEG source-amplitude images from resting-state signals in 41 healthy control subjects, for all standard frequency bands. Comparisons between resting-state MEG sources images and known neurophysiology were provided. Additionally, in simulations and cases with MEG human responses, the results obtained from using conventional beamformer technique were compared with those from Fast-VESTAL, which highlighted the beamformer's problems of signal leaking and distorted source time-courses.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/fisiología , Magnetoencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Algoritmos , Femenino , Humanos , Masculino , Descanso/fisiología , Relación Señal-Ruido
4.
Neuroimage Clin ; 8: 210-23, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26106545

RESUMEN

A barrier in the diagnosis of mild traumatic brain injury (mTBI) stems from the lack of measures that are adequately sensitive in detecting mild head injuries. MRI and CT are typically negative in mTBI patients with persistent symptoms of post-concussive syndrome (PCS), and characteristic difficulties in sustaining attention often go undetected on neuropsychological testing, which can be insensitive to momentary lapses in concentration. Conversely, visual tracking strongly depends on sustained attention over time and is impaired in chronic mTBI patients, especially when tracking an occluded target. This finding suggests deficient internal anticipatory control in mTBI, the neural underpinnings of which are poorly understood. The present study investigated the neuronal bases for deficient anticipatory control during visual tracking in 25 chronic mTBI patients with persistent PCS symptoms and 25 healthy control subjects. The task was performed while undergoing magnetoencephalography (MEG), which allowed us to examine whether neural dysfunction associated with anticipatory control deficits was due to altered alpha, beta, and/or gamma activity. Neuropsychological examinations characterized cognition in both groups. During MEG recordings, subjects tracked a predictably moving target that was either continuously visible or randomly occluded (gap condition). MEG source-imaging analyses tested for group differences in alpha, beta, and gamma frequency bands. The results showed executive functioning, information processing speed, and verbal memory deficits in the mTBI group. Visual tracking was impaired in the mTBI group only in the gap condition. Patients showed greater error than controls before and during target occlusion, and were slower to resynchronize with the target when it reappeared. Impaired tracking concurred with abnormal beta activity, which was suppressed in the parietal cortex, especially the right hemisphere, and enhanced in left caudate and frontal-temporal areas. Regional beta-amplitude demonstrated high classification accuracy (92%) compared to eye-tracking (65%) and neuropsychological variables (80%). These findings show that deficient internal anticipatory control in mTBI is associated with altered beta activity, which is remarkably sensitive given the heterogeneity of injuries.


Asunto(s)
Ritmo beta/fisiología , Lesión Encefálica Crónica/fisiopatología , Núcleo Caudado/fisiopatología , Corteza Cerebral/fisiopatología , Movimientos Oculares/fisiología , Síndrome Posconmocional/fisiopatología , Percepción Visual/fisiología , Adulto , Anticipación Psicológica/fisiología , Medidas del Movimiento Ocular , Femenino , Humanos , Magnetoencefalografía , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA