Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 389(16): 1466-1476, 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37634188

RESUMEN

BACKGROUND: Data regarding clinical outcomes after optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI) as compared with angiography-guided PCI are limited. METHODS: In this prospective, randomized, single-blind trial, we randomly assigned patients with medication-treated diabetes or complex coronary-artery lesions to undergo OCT-guided PCI or angiography-guided PCI. A final blinded OCT procedure was performed in patients in the angiography group. The two primary efficacy end points were the minimum stent area after PCI as assessed with OCT and target-vessel failure at 2 years, defined as a composite of death from cardiac causes, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization. Safety was also assessed. RESULTS: The trial was conducted at 80 sites in 18 countries. A total of 2487 patients underwent randomization: 1233 patients were assigned to undergo OCT-guided PCI, and 1254 to undergo angiography-guided PCI. The minimum stent area after PCI was 5.72±2.04 mm2 in the OCT group and 5.36±1.87 mm2 in the angiography group (mean difference, 0.36 mm2; 95% confidence interval [CI], 0.21 to 0.51; P<0.001). Target-vessel failure within 2 years occurred in 88 patients in the OCT group and in 99 patients in the angiography group (Kaplan-Meier estimates, 7.4% and 8.2%, respectively; hazard ratio, 0.90; 95% CI, 0.67 to 1.19; P = 0.45). OCT-related adverse events occurred in 1 patient in the OCT group and in 2 patients in the angiography group. Stent thrombosis within 2 years occurred in 6 patients (0.5%) in the OCT group and in 17 patients (1.4%) in the angiography group. CONCLUSIONS: Among patients undergoing PCI, OCT guidance resulted in a larger minimum stent area than angiography guidance, but there was no apparent between-group difference in the percentage of patients with target-vessel failure at 2 years. (Funded by Abbott; ILUMIEN IV: OPTIMAL PCI ClinicalTrials.gov number, NCT03507777.).


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Tomografía de Coherencia Óptica , Humanos , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Método Simple Ciego , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Diabetes Mellitus , Implantación de Prótesis Vascular/métodos , Stents
2.
Eur Heart J Suppl ; 26(Suppl 1): i6-i10, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38867865

RESUMEN

The COAPT 5-year data demonstrate that compared with medical treatment transcatheter edge-to-edge repair (TEER) with the MitraClip in symptomatic patients with Grade 3+/Grade 4+ secondary mitral regurgitation (SMR) reduced by nearly half the annualized hospitalization risk (33 vs. 57%), by almost 30% the death rate (57 vs. 67%) and achieved significant and durable SMR reduction in 95% of patients. Control patients who crossed over to TEER at 2 years had better prognosis, but nearly half of them died before reaching crossover eligibility. Death or hospitalization for heart failure (HHF) occurred in 73.6% of TEER patients and 91.5% of controls within 5 years, pointing to a need for further study to address left ventricle (LV) dysfunction, the underlying cause of patient's disease. MTRA-FR targeted SMR using the same device and did not improve the composite endpoint of all-cause mortality or HHF at 12 months. Possible reasons for the discrepancy include enrolment of patients with more severe MR and less-advanced LV disease (dilation/dysfunction), less-procedural complications, and higher success in reducing MR in COAPT compared with MITRA-FR. Thus, the ideal patient for MitraClip treatment would be one with severe MR, but with no too severe LV dilation/dysfunction, which is what differentiates COAPT patients from those in MITRA-FR.

3.
N Engl J Med ; 382(13): 1208-1218, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-32050061

RESUMEN

BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Polímeros , Sirolimus/análogos & derivados , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Quimioterapia Combinada , Stents Liberadores de Fármacos/efectos adversos , Cardiopatías/mortalidad , Hemorragia/inducido químicamente , Humanos , Estimación de Kaplan-Meier , Inhibidores de Agregación Plaquetaria/efectos adversos , Diseño de Prótesis , Método Simple Ciego , Sirolimus/administración & dosificación
4.
Eur Heart J Suppl ; 24(Suppl I): I16-I21, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36380798

RESUMEN

Transcatheter mitral valve replacement (TMVR) is a novel therapeutic option for patients with severe mitral regurgitation (MR) at high or prohibitive surgical risk. Most TMVR technologies under investigation use either a trans-apical or a trans-septal approach via dedicated multistep anchoring systems. Transcatheter mitral valve replacement offers several potential advantages over transcatheter repair, notably a greater and more sustained MR reduction. At the same time, significant engineering challenges and potential disadvantages must be acknowledged. Preclinical and clinical studies have shown promising results, demonstrating TMVR feasibility. Nevertheless, further development, testing, and trials are needed before considering TMVR as a definitive therapeutic option for MR in a wide range of anatomical scenarios.

5.
Catheter Cardiovasc Interv ; 97(5): E676-E679, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32744772

RESUMEN

The development and progressive enlargement over time of multiple saccular coronary artery aneurysms (CAA) after implantation of everolimus-eluting stent and bioresorbable vascular scaffolds (BVS) have been reported. CAA was successfully excluded by two overlapped covered stents expanded inside a long metallic drug-eluting stent to avoid dislodgment at the overlap point. Optical coherence tomography (OCT) was repeatedly performed to monitor CAA expansion and to guide treatment through precise measurement of aneurysm length and vessel size at the landing zone. At 10-month follow-up, coronary computed tomography angiography showed persistent CAA exclusion. To the best of our knowledge, this is the first report of this technique to exclude a long CCA segment.


Asunto(s)
Implantes Absorbibles , Aneurisma Coronario , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/etiología , Aneurisma Coronario/cirugía , Angiografía Coronaria , Humanos , Masculino , Persona de Mediana Edad , Nigeria , Intervención Coronaria Percutánea/efectos adversos , Stents , Andamios del Tejido , Tomografía de Coherencia Óptica , Resultado del Tratamiento
6.
Eur Heart J ; 41(3): 383-391, 2020 01 14.
Artículo en Inglés | MEDLINE | ID: mdl-31504405

RESUMEN

AIMS: The CLIMA study, on the relationship between coronary plaque morphology of the left anterior descending artery and twelve months clinical outcome, was designed to explore the predictive value of multiple high-risk plaque features in the same coronary lesion [minimum lumen area (MLA), fibrous cap thickness (FCT), lipid arc circumferential extension, and presence of optical coherence tomography (OCT)-defined macrophages] as detected by OCT. Composite of cardiac death and target segment myocardial infarction was the primary clinical endpoint. METHODS AND RESULTS: From January 2013 to December 2016, 1003 patients undergoing OCT evaluation of the untreated proximal left anterior descending coronary artery in the context of clinically indicated coronary angiogram were prospectively enrolled at 11 independent centres (clinicaltrial.gov identifier NCT02883088). At 1-year, the primary clinical endpoint was observed in 37 patients (3.7%). In a total of 1776 lipid plaques, presence of MLA <3.5 mm2 [hazard ratio (HR) 2.1, 95% confidence interval (CI) 1.1-4.0], FCT <75 µm (HR 4.7, 95% CI 2.4-9.0), lipid arc circumferential extension >180° (HR 2.4, 95% CI 1.2-4.8), and OCT-defined macrophages (HR 2.7, 95% CI 1.2-6.1) were all associated with increased risk of the primary endpoint. The pre-specified combination of plaque features (simultaneous presence of the four OCT criteria in the same plaque) was observed in 18.9% of patients experiencing the primary endpoint and was an independent predictor of events (HR 7.54, 95% CI 3.1-18.6). CONCLUSION: The simultaneous presence of four high-risk OCT plaque features was found to be associated with a higher risk of major coronary events.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico , Tomografía de Coherencia Óptica/métodos , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo
7.
Catheter Cardiovasc Interv ; 96(2): 255-265, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31905259

RESUMEN

BACKGROUND: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. METHODS: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. RESULTS: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p = .001), due to more cardiac deaths (3.4 vs. 1.1%; p = .002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p = .114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p = .526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p = .041), but similar rate of TLR (6 vs. 4%; p = .405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. CONCLUSIONS: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 94(7): 972-979, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31037840

RESUMEN

BACKGROUND: The ULISSE registry has demonstrated the real-world performance of the Ultimaster biodegradable polymer sirolimus-eluting stent (BP-SES) in a large cohort of patients undergoing percutaneous coronary intervention, including a large proportion of patients presenting with acute myocardial infarction (AMI). METHODS: We performed a subgroup analysis of the ULISSE registry in AMI patients and compared the outcomes of this vulnerable cohort with that of patients presenting without AMI (non-AMI). The primary end point was the incidence of 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (TLR). RESULTS: Of 1,660 patients included in the ULISSE registry, 381(23%) presented with AMI, 207(54.3%) non-ST elevation myocardial infarction, and 174(45.7%) ST-elevation myocardial infarction. Compared with non-AMI patients, those with AMI were more frequently female and smokers, with lower left ventricular ejection fraction (LVEF) and chronic kidney disease requiring dialysis. At 1 year, TLF rate was significantly higher in AMI than non-AMI patients (7.9 vs. 4.1%; HR 1.98, CI 95% 1.22-3.23; p = .005) driven by higher rate of cardiac death (4.0 vs. 1.1%; HR 3.59, CI 95% 1.64-7.88; p = .01) and TV-MI (2.8 vs 0.9%; HR 2.99,CI 95% 1.22-7.37; p = .01), without differences in TLR rate (4.3 vs. 2.9%,HR 0.66, CI95% 0.35-1.25; p = .2). At multivariate Cox regression analysis, eGFR <40 mL/min (HR: 2.868) and LVEF <40% (HR: 2.394) were the only independent predictors of TLF. CONCLUSIONS: In AMI patients, Ultimaster BP-SES implantation was associated with higher rate of TLF and definite stent thrombosis compared with non-AMI patients. The high incidence of adverse events was mainly driven by the unfavorable baseline risk profile.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Supervivencia sin Progresión , Diseño de Prótesis , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo
9.
Eur Heart J ; 38(13): 961-969, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-27190095

RESUMEN

Aims: Although a true clinical challenge, high bleeding risk patients with an acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) have never been specifically studied. Leaders Free ACS, a pre-specified Leaders Free sub-study, determined efficacy, and safety of a combination of 1-month dual anti-platelet therapy (DAPT) with implantation of either a polymer-free Biolimus-A9-coated stent (BA9-DCS) or a bare-metal stent (BMS) in these patients. Methods and results: Leaders Free included 2466 patients undergoing PCI who had at least 1 of 13 pre-defined factors for an increased bleeding risk. Of these, 659 ACS patients were included in this analysis (BA9-DCS 330, BMS 329). At 12-month follow-up, treatment with the BA9-DCS was more effective (clinically driven target-lesion revascularization 3.9 vs. 9.0%, P = 0.009) and safer (cumulative incidence of cardiac death, myocardial infarction, or definite or probable stent thrombosis 9.3 vs. 18.5%, P = 0.001), driven by significantly lower rates of cardiac mortality (3.4 vs. 6.9%, P = 0.049) and myocardial infarction (6.9 vs. 13.8%, P = 0.005). Conclusion: We believe that the results of this sub-analysis from the Leaders Free trial are likely to significantly impact clinical practice for high bleeding risk patients presenting with an ACS: the use of a BMS can, in our view, no longer be recommended, and, given the paucity of available data for second-generation DES with shortened DAPT in these patients, the BA9-DCS should currently be considered as the device with the strongest evidence to support its use for this indication.


Asunto(s)
Stents Liberadores de Fármacos , Hemorragia/etiología , Inmunosupresores/administración & dosificación , Infarto del Miocardio sin Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/cirugía , Sirolimus/análogos & derivados , Síndrome Coronario Agudo/cirugía , Anciano , Método Doble Ciego , Quimioterapia Combinada , Femenino , Oclusión de Injerto Vascular/etiología , Humanos , Masculino , Infarto del Miocardio sin Elevación del ST/tratamiento farmacológico , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Sirolimus/administración & dosificación , Resultado del Tratamiento
10.
Lancet ; 388(10060): 2618-2628, 2016 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-27806900

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. METHODS: In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm2), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586. FINDINGS: Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm2 (4·67-7·80) with IVUS guidance, and 5·49 mm2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm2; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37). INTERPRETATION: OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance. FUNDING: St Jude Medical.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional/métodos , Anciano , Vasos Coronarios/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento
11.
J Endovasc Ther ; 23(4): 549-60, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27270761

RESUMEN

PURPOSE: To compare the feasibility and safety of proximal cerebral protection to a distal filter during carotid artery stenting (CAS) via a transbrachial (TB) or transradial (TR) approach. METHODS: Among 856 patients who underwent CAS between January 2007 and July 2015, 214 (25%) patients (mean age 72±8 years; 154 men) had the procedure via a TR (n=154) or TB (n=60) approach with either Mo.MA proximal protection (n=61) or distal filter protection (n=153). The Mo.MA group (mean age 73±7 years; 54 men) had significantly more men and more severe stenosis than the filter group (mean age 71±8 years; 100 men). Stent type and CAS technique were left to operator discretion. Heparin and a dedicated closure device or bivalirudin and manual compression were used in TR and TB accesses, respectively. Technical and procedure success, crossover to femoral artery, 30-day major adverse cardiovascular/cerebrovascular events (MACCE; death, all strokes, and myocardial infarction), vascular complications, and radiation exposure were compared between groups. RESULTS: Crossover to a femoral approach was required in 1/61 (1.6%) Mo.MA patient vs 11/153 (7.1%) filter patients mainly due to technical difficulty in engaging the target vessel. Five Mo.MA patients developed acute intolerance to proximal occlusion; 4 were successfully shifted to filter protection. A TR patient was shifted to filter because the Mo.MA system was too short. CAS was technically successful in the remaining 55 (90%) Mo.MA patients and 142 (93%) filter patients. The MACCE rate was 0% in the Mo.MA patients and 2.8% in the filter group (p=0.18). Radiation exposure was similar between groups. Major vascular complications occurred in 1/61 (1.6%) and in 3/153 (1.96%) patients in the Mo.MA and filter groups (p=0.18), respectively, and were confined to the TB approach in the early part of the learning curve. Chronic radial artery occlusion was detected by Doppler ultrasound in 2/30 (6.6%) Mo.MA patients and in 4/124 (3.2%) filter patients by clinical assessment (p=0.25) at 8.1±7.5-month follow-up. CONCLUSION: CAS with proximal protection via a TR or TB approach is a feasible, safe, and effective technique with a low rate of vascular complications.


Asunto(s)
Angioplastia/instrumentación , Arteria Braquial , Estenosis Carotídea/terapia , Cateterismo Periférico/métodos , Dispositivos de Protección Embólica , Arteria Radial , Stents , Anciano , Anciano de 80 o más Años , Angioplastia/efectos adversos , Angioplastia/métodos , Angioplastia/mortalidad , Anticoagulantes/uso terapéutico , Arteria Braquial/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/mortalidad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Angiografía por Tomografía Computarizada , Estudios de Factibilidad , Femenino , Humanos , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/prevención & control , Diseño de Prótesis , Arteria Radial/diagnóstico por imagen , Exposición a la Radiación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler
12.
Eur Heart J ; 36(47): 3346-55, 2015 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-26242713

RESUMEN

AIMS: ILUMIEN I is the largest prospective, non-randomized, observational study of percutaneous coronary intervention (PCI) procedural practice in patients undergoing intra-procedural pre- and post-PCI fractional flow reserve (FFR) and optical coherence tomography (OCT). We report on the impact of OCT on physician decision-making and the association with post-PCI FFR values and early clinical events. METHODS AND RESULTS: Optical coherence tomography and documentary FFR were performed pre- and post-PCI in 418 patients (with 467 stenoses) with stable or unstable angina or NSTEMI. Based on pre-PCI OCT, the procedure was altered in 55% of patients (57% of all stenoses) by selecting different stent lengths (shorter in 25%, longer in 43%). After clinically satisfactory stent implantation using angiographic guidance, post-PCI FFR and OCT were repeated. Optical coherence tomography abnormalities deemed unsatisfactory by the implanting physician were identified: 14.5% malapposition, 7.6% under-expansion, 2.7% edge dissection and prompted further stent optimization based on OCT in 25% of patients (27% of all stenoses) using additional in-stent post-dilatation (81%, 101/124) or placement of 20 new stents (12%). Optimization subgroups were identified post hoc: stent placement without reaction to OCT findings (n = 137), change in PCI planning by pre-PCI OCT (n = 165), post-PCI optimization based on post-PCI OCT (n = 41), change in PCI planning, and post-PCI optimization based on OCT (n = 65). Post-PCI FFR values were significantly different (P = 0.003) between optimization groups (lower in cases with pre- and post-PCI reaction to OCT) but no longer different after post-PCI stent optimization. MACE events at 30 days were low: death 0.25%, MI 7.7%, repeat PCI 1.7%, and stent thrombosis 0.25%. CONCLUSION: Physician decision-making was affected by OCT imaging prior to PCI in 57% and post-PCI in 27% of all cases. CLINICALTRIALS. GOV IDENTIFIER: NCT01663896, Observational Study of Optical Coherence Tomography (OCT) in Patients Undergoing Fractional Flow Reserve (FFR) and Percutaneous Coronary Intervention (ILUMIEN I).


Asunto(s)
Estenosis Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Angina de Pecho/etiología , Toma de Decisiones Clínicas , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/fisiopatología , Femenino , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Masculino , Persona de Mediana Edad , Pautas de la Práctica en Medicina , Estudios Prospectivos , Stents , Tomografía de Coherencia Óptica/métodos
13.
Catheter Cardiovasc Interv ; 85(4): 544-53, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25115944

RESUMEN

OBJECTIVES: To characterize the treatment of complex bifurcation lesions (BL) with the Tryton Bifurcation Stent (TBS) paired with an everolimus-eluting stent (EES). BACKGROUND: Complex BL are associated with higher procedural complications and poorer long-term outcomes. The TBS is a dedicated side-branch (SB) stent designed to be used in conjunction with a standard drug-eluting stent. METHODS: Prospectively identified, consecutive patients underwent TBS+EES stenting of BL using a protocol which included TBS postdilation and simultaneous final kissing balloon inflations (FKBI). All lesions were systematically evaluated with coronary angiography and IVUS, obtained at procedure completion and at 9 months, and were assessed by independent core laboratories. RESULTS: Thirty-three BL were treated in 32 patients presenting primarily (87.5%) with stable angina and complex BL with angiographic apparent disease in the main vessel (MV) and SB in 87.9% and 75% by site and core evaluation, respectively. Procedural success was 100% and high postprocedure percent stent expansion (MV 96 [93, 109]%, SB 88 [77, 100]%, carina MV 135 [99, 166]%, carina SB 116 [91, 130]%) was demonstrated by IVUS. At 9-month angiographic follow-up (n = 28 patients), one MV in-segment restenosis and one SB in-stent restenosis were observed. SB in-stent late lumen loss was 0.41 ± 0.27 mm. IVUS assessment revealed the absence of stent recoil; percent carinal neointimal hyperplasia (NIH) was 1.8 [0.0,11.2]% in MV and 15.0 [6.7,23.5]% in SB, with NIH volume obstruction of 2.0 [0.7,4.3]% in MV and 14.2 [7.5,29.6]% in SB. CONCLUSIONS: Stenting of complex BL with the TBS+EES provides high acute success with sustained clinical, angiographic, and IVUS results at 9 months. These excellent results are likely due to the extent of stent expansion at the carina.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Ultrasonografía Intervencional , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
14.
J Endovasc Ther ; 21(1): 127-36, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24502493

RESUMEN

PURPOSE: To assess the safety and efficacy of carotid artery stenting (CAS) of the left internal carotid artery (LICA) from a right radial/brachial approach in patients with bovine aortic arch. METHODS: Among 505 consecutive CAS patients treated at our facility between June 2007 and December 2012, 60 (11.9%) patients (44 men; mean age 73±9 years) with LICA stenosis and bovine arch were treated from a right radial (n=32) or brachial (n=28) approach. Three quarters of the patients had characteristics qualifying them at high surgical risk; 52 were asymptomatic. The types of cerebral protection (a distal filter or proximal MO.MA system), stent, and technique were at the operation's discretion. RESULTS: The radial/brachial approach was successful in 59 (98.3%) of 60 procedures; 1 case was converted to a femoral approach. Proximal protection was used in 15 cases (11 brachial, 4 radial) with severe, soft plaques, although the MO.MA system proved too short in a tall patient having a radial approach and a filter was used. Clinical success with no adverse events was 96.7% owing to 1 retinal embolism and 1 minor stroke. Vascular complications occurred in 2 (3.3%) brachial group patients. No major bleeding was encountered. Over a mean follow-up of 18.7±17.5 months, midterm event-free survival was 93%. No target vessel revascularization was necessary. CONCLUSION: CAS via a right radial or brachial approach is safe and effective in patients with LICA stenosis and types 1 or 2 bovine arch.


Asunto(s)
Angioplastia de Balón/instrumentación , Angioplastia de Balón/métodos , Aorta Torácica/anomalías , Arteria Braquial , Arteria Carótida Interna , Estenosis Carotídea/terapia , Arteria Radial , Stents , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Arteria Braquial/diagnóstico por imagen , Estenosis Carotídea/diagnóstico , Supervivencia sin Enfermedad , Dispositivos de Protección Embólica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Arteria Radial/diagnóstico por imagen , Radiografía Intervencional , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
J Am Coll Cardiol ; 84(4): 368-378, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-38759907

RESUMEN

BACKGROUND: ILUMIEN IV was the first large-scale, multicenter, randomized trial comparing optical coherence tomography (OCT)-guided vs angiography-guided stent implantation in patients with high-risk clinical characteristics and/or complex angiographic lesions. OBJECTIVES: The authors aimed to specifically examine outcomes in the complex angiographic lesions subgroup. METHODS: From the original trial population (N = 2,487), high-risk patients without complex angiographic lesions were excluded (n = 514). Complex angiographic lesion characteristics included: 1) long or multiple lesions with intended total stent length ≥28 mm; 2) bifurcation lesion with intended 2-stent strategy; 3) severely calcified lesion; 4) chronic total occlusion; or 5) in-stent restenosis. The study endpoints were: 1) final minimal stent area (MSA); 2) 2-year composite of serious major adverse cardiovascular events (MACEs) (cardiac death, target-vessel myocardial infarction [MI], or stent thrombosis); and 3) 2-year effectiveness, defined as target-vessel failure (TVF), a composite of cardiac death, target-vessel MI, or ischemia-driven target-vessel revascularization. RESULTS: The postpercutaneous coronary intervention (PCI) MSA was larger in the OCT-guided (n = 992) vs angiography-guided (n = 981) group (5.56 ± 1.95 mm2 vs 5.26 ± 1.81 mm2; difference, 0.30; 95% CI: 0.14-0.47; P < 0.001). Compared with angiography-guided PCI, OCT-guided PCI resulted in a lower risk of serious MACE (3.1% vs 4.9%; HR: 0.63; 95% CI: 0.40-0.99; P = 0.04). TVF was not significantly different between groups (7.3% vs 8.8%; HR: 0.82; 95% CI: 0.59-1.12; P = 0.20). CONCLUSIONS: In complex angiographic lesions, OCT-guided PCI led to a larger MSA and reduced the serious MACE, the composite of cardiac death, target-vessel MI, or stent thrombosis, compared with angiography-guided PCI at 2 years, but did not significantly improve TVF. (Optical Coherence Tomography Guided Coronary Stent Implantation Compared to Angiography: A Multicenter Randomized Trial in PCI; NCT03507777).


Asunto(s)
Angiografía Coronaria , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Angiografía Coronaria/métodos , Anciano , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Stents , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Resultado del Tratamiento
16.
Front Cardiovasc Med ; 10: 1095661, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37063961

RESUMEN

Background: Percutaneous suture-mediated patent foramen ovale (PFO) closure has recently been used with the aim of avoiding double-disc nitinol device implantation. This novel technique has been carried out successfully in several centers offering PFO closure with an effective closure rate comparable to conventional double-disc devices. Case summary: A 50-year-old man, a pentathlon athlete, suffering from a previous left-sided ischemic stroke, underwent percutaneous closure of a permanent right-to-left shunt via PFO with a large fenestrated septum primum aneurysm at another institution. The NobleStitch® system was successfully implanted using local anesthesia and under angiographic-fluoroscopic monitoring. He was discharged home on aspirin 100 mg daily with a moderate residual shunt on contrast transthoracic echocardiography (cTTE) that persisted unaltered at subsequent controls. After 7 months, unable to resume sporting activity because of physical discomfort and dyspnea on exertion, the patient asked for a second opinion at our Heart and Brain clinic. Two-dimensional (2D) TTE showed septum primum laceration next to a radiopaque polypropylene knot with a moderate bidirectional shunt located at the fenestrated septum primum far from the PFO site. A catheter-based closure of the septal defect was therefore planned under local anesthesia and rotational intracardiac echo monitoring. An equally sized discs 28.5 mm × 28.5 mm Flex II UNI occluder (Occlutech GmbH, Jena, Germany) was successfully implanted across the atrial septal defect without complications. The patient was discharged in good clinical conditions; dual antiplatelet therapy (aspirin 100 mg/daily and clopidogrel 75 mg/daily) was recommended for 2 months and then single antiplatelet therapy (aspirin100 mg/daily) up to 6 months. Abolition of the residual shunt was confirmed at 1- and 6-month follow-up by contrast transcranial Doppler and 2D color Doppler cTTE. Discussion: Closing a PFO with a suture-base system, without leaving a device implant behind, may be a cutting-edge technology and potential alternative to traditional devices. Nevertheless, meticulous selection of the PFO anatomies by 2D TEE is key to a successful closure procedure in order to avoid complications that must be managed again with a second percutaneous procedure or by surgery.

17.
Minerva Cardiol Angiol ; 71(3): 275-283, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-32657556

RESUMEN

BACKGROUND: In this in-vivo human study we tested the reproducibility for optical coherence tomography (OCT) assessment of lumen area (LA) and plaque components measurements, such as lipid arc extension and fibrous cap thickness (FCt). METHODS: We tested the variability of LA, lipid arc and FCt assessments in two repeated OCT pullbacks from the same diseased coronary segment matched using fiduciary anatomical landmarks. In particular, for the reliability of minimal FCt measurement we compared four different approaches based on continuous (longitudinal) or segmental (spot) individuation of smaller thickness: 1) comparison of single minimal FCt individuated alongside all plaque extension in the two pullbacks (Longitudinal (L)-spot minimal FCt value); 2) comparison of the mean FCt values of the plaque in the two pullbacks (L-plot mean FCt value); 3) comparison between the single minimal FCt value obtained in the first pullback and the single FCt obtained in the matched CS of second pullback (L-spot CS matched FCt value); 4) comparison of measurements obtained by visual selection of CS with minimal FCt s in the two pullbacks (single-spot minimal FCt value). RESULTS: From the paired analyses of 20 non culprit lesions (accounting for a total of 387 matched CS), we found a suboptimal in-segment correlation for LA (Intra-Class Coefficient [ICC] 0.731), but a good in-segment correlation for lipid arc (ICC 0.963). Regarding FCt measurement, a high reproducibility was obtained applying continuous assessment; in particular, the best correlation was observed with L-spot minimal FCt value and the L-plot mean FCt (ICC 0.893 and 0.952, respectively) with small inter-pullback differences (confidence intervals less than 0.04 mm). CONCLUSIONS: In this methodological study we observed a good reproducibility for quantitative plaque measurements with OCT confirming its reliability for serial assessment. In particular, longitudinal measurement in multiple adjacent frames seems to be the more accurate and reproducible approach for sequential FCt assessment.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/métodos , Placa Aterosclerótica/diagnóstico por imagen , Fibrosis , Lípidos
18.
Am J Cardiol ; 209: 173-180, 2023 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-37858597

RESUMEN

Low-flow low-gradient (LF-LG) aortic stenosis (AS) may occur with preserved or depressed left ventricular ejection fraction (LVEF). Both situations represent the most challenging subset of patients to manage and generally have a poor prognosis. Few and controversial data exist on the outcomes of these patients compared with normal flow-high gradient (NF-HG) AS after transcatheter aortic valve replacement (TAVR). We sought to characterize different transvalvular flow-gradient patterns and to examine their prognostic value after TAVR. We enrolled 1,208 patients with severe AS and categorized as follow: 976 patients NF-HG (mean aortic pressure gradient [MPG] ≥40 mm Hg), 107 paradoxical LF-LG (pLF-LG, MPG <40 mm Hg, LVEF ≥50%, stroke volume index <35 ml/m2), and 125 classical LF-LG (cLF-LG) (MPG <40 mm Hg, LVEF <50%, stroke volume index <35 ml/m2). When compared with NF-HG and pLF-LG, cLF-LG had a worse symptomatic status (New York Heart Association III to IV 86% vs 62% and 67%, p <0.001), a higher prevalence of eccentric hypertrophy and a higher level of LV global afterload reflected by a higher valvuloarterial impedance. Valvular function after TAVR was excellent over time in all patients. While 30-day mortality (p = 0.911) did not differ significantly among groups, cLF-LG had a lower 5-year survival rate (LF-LG 50% vs pLF-LG 62% and NF-HG 68%, p <0.05). cLF-LG was associated with a hazard ratio for mortality of 2.41 (95% confidence interval 1.65 to 3.52, p <0.001). In conclusion, TAVR is an effective procedure regardless of transvalvular flow-gradient patterns. However, special care should be given to characterized hemodynamic of AS, as patients with pLF-LG had similar survival rates than patients with NF-HG, whereas cLF-LG is associated with a twofold increased risk of mortality at 5-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
19.
Eur Heart J Cardiovasc Imaging ; 24(4): 437-445, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-35718858

RESUMEN

AIMS: The aim of this study was to assess the morphological characteristics and prognostic implications of the optical coherence tomography (OCT)-derived lipid core burden index (LCBI). METHODS AND RESULTS: OCT-LCBI was assessed in 1003 patients with 1-year follow-up from the CLIMA multicentre registry using a validated software able to automatically obtain a maximum OCT-LCBI in 4 mm (maxOCT-LCBI4mm). Primary composite clinical endpoint included cardiac death, myocardial infarction, and target-vessel revascularization. A secondary analysis using clinical outcomes of CLIMA study was performed. Patients with a maxOCT-LCBI4mm ≥ 400 showed higher prevalence of fibrous cap thickness (FCT) <75 µm [odds ratio (OR) 1.43, 95% confidence interval (CI) 1.03-1.99; P = 0.034], lipid pool arc >180° (OR 3.93, 95%CI 2.97-5.21; P < 0.001), minimum lumen area <3.5 mm2 (OR 1.5, 95%CI 1.16-1.94; P = 0.002), macrophage infiltration (OR 2.38, 95%CI 1.81-3.13; P < 0.001), and intra-plaque intimal vasculature (OR 1.34, 95%CI 1.05-1.72; P = 0.021). A maxOCT-LCBI4mm ≥400 predicted the primary endpoint [adjusted hazard ratio (HR) 1.86, 95%CI 1.1-3.2; P = 0.019] as well as the CLIMA endpoint (HR 2.56, 95%CI 1.24-5.29; P = 0.011). Patients with high lipid content and thin FCT < 75 µm were at higher risk for adverse events (HR 4.88, 95%CI 2.44-9.72; P < 0.001). CONCLUSIONS: A high maxOCT-LCBI4mm was related to poor outcome and vulnerable plaque features. This study represents a step further in the automated assessment of the coronary plaque risk profile.


Asunto(s)
Placa Aterosclerótica , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Valor Predictivo de las Pruebas , Placa Aterosclerótica/diagnóstico por imagen , Fibrosis , Lípidos , Sistema de Registros
20.
J Endovasc Ther ; 19(6): 734-42, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23210870

RESUMEN

PURPOSE: To evaluate the safety and efficacy of drug-eluting balloons (DEB) for the treatment of in-stent restenosis (ISR) after carotid artery stenting (CAS). METHODS: Among 830 consecutive patients undergoing CAS between November 2001 and June 2012, significant ISR (>80% stenosis) occurred in 10 (1.2%) asymptomatic patients. Angioplasty with DEB treatment was performed in 7 patients (6 internal and 1 common carotid arteries) at a mean of 20.9 ± 19.4 months (median 12.1) after CAS. Intravascular ultrasound (IVUS)-guided predilation with distal cerebral protection was carried out with a cutting balloon followed by inflation of a DEB with a 1:1 stent-to-balloon size ratio. RESULTS: Technical/procedural success was achieved in all cases. Angiographic stenosis decreased from 83%± 5% to 18%± 6%. At IVUS evaluation, minimal lumen area increased from 3.19 ± 1.73 to 12.78 ± 1.97 mm(2) (p=0.0001), stent area was unchanged (from 17.36 ± 4.36 to 17.52 ± 4.34 mm(2), p=0.70), and the restenosis area decreased from 13.58 ± 5.27 to 4.71 ± 3.06 mm(2) (p=0.0005). At a mean follow-up of 13.7 ± 1.5 months (median 13.7), 1 patient had a minor stroke ipsilateral to the ISR vessel 2 months after DEB treatment; the stent was widely patent on duplex ultrasound and angiographic images. Overall, the average PSV decreased from 4.0 ± 1.0 to 0.9 ± 0.1 m/s (p=0.0001). At 6 and 12 months, PSVs after DEB treatment were significantly lower compared to those assessed at comparable intervals after CAS. CONCLUSION: The use of DEBs to treat ISR after CAS shows promising acute and midterm results.


Asunto(s)
Angioplastia de Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Arteria Carótida Común , Estenosis Carotídea/terapia , Catéteres , Materiales Biocompatibles Revestidos , Paclitaxel/administración & dosificación , Stents , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/fisiopatología , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/fisiopatología , Estenosis Carotídea/diagnóstico , Estenosis Carotídea/fisiopatología , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Ultrasonografía Intervencional , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA