Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Soft Matter ; 16(28): 6501-6513, 2020 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-32597450

RESUMEN

Acoustically-responsive scaffolds (ARSs), which are composite fibrin hydrogels, have been used to deliver regenerative molecules. ARSs respond to ultrasound in an on-demand, spatiotemporally-controlled manner via a mechanism termed acoustic droplet vaporization (ADV). Here, we study the ADV-induced, time-dependent micromechanical and microstructural changes to the fibrin matrix in ARSs using confocal fluorescence microscopy as well as atomic force microscopy. ARSs, containing phase-shift double emulsion (PSDE, mean diameter: 6.3 µm), were exposed to focused ultrasound to generate ADV - the phase transitioning of the PSDE into gas bubbles. As a result of ADV-induced mechanical strain, localized restructuring of fibrin occurred at the bubble-fibrin interface, leading to formation of locally denser regions. ADV-generated bubbles significantly reduced fibrin pore size and quantity within the ARS. Two types of ADV-generated bubble responses were observed in ARSs: super-shelled spherical bubbles, with a growth rate of 31 µm per day in diameter, as well as fluid-filled macropores, possibly as a result of acoustically-driven microjetting. Due to the strain stiffening behavior of fibrin, ADV induced a 4-fold increase in stiffness in regions of the ARS proximal to the ADV-generated bubble versus distal regions. These results highlight that the mechanical and structural microenvironment within an ARS can be spatiotemporally modulated using ultrasound, which could be used to control cellular processes and further the understanding of ADV-triggered drug delivery for regenerative applications.


Asunto(s)
Acústica , Fibrina , Emulsiones , Hidrogeles , Volatilización
2.
J Ultrasound Med ; 38(7): 1855-1864, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30548874

RESUMEN

OBJECTIVES: Contrast-enhanced diagnostic ultrasound (US) has a potential to induce localized biological effects. The potential for contrast-enhanced diagnostic US bioeffects in liver were researched, with guidance from a report by Yang et al (Ultrasonics 2012; 52:1065-1071). METHODS: Contact and standoff scanning was performed for 10 minutes with a diagnostic US phased array at 1.6 MHz during bolus injection or infusion of a contrast agent at a high dose. The impact of the imaging on rat liver was investigated by measuring enzyme release, microvascular leakage, and staining of injured hepatocytes. RESULTS: The results showed liver enzyme release at 30 minutes, indicating liver injury, and elevated extraction of Evans blue dye, indicating microvascular leakage. In addition, Evans blue and trypan blue vital-staining methods revealed scattered stained cells within the US scan plane. For the Evans blue method, fluorescent cell counts in frozen sections were greatest for standoff exposure with contrast infusion. The count decreased strongly with depth for bolus injection, which was probably reflective of the high attenuation noted for this agent delivery method. CONCLUSIONS: The results qualitatively confirmed the report by Yang et al and additionally showed hepatocyte vital staining. Research is needed to determine the threshold for the effects and the contrast agent dose response.


Asunto(s)
Medios de Contraste/efectos adversos , Hepatocitos/efectos de los fármacos , Ultrasonografía , Animales , Azul de Evans , Masculino , Ratas , Ratas Sprague-Dawley
3.
Magn Reson Med ; 77(3): 1318-1328, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27029318

RESUMEN

PURPOSE: To elucidate the dynamic, structural, and molecular properties that create inhomogeneous magnetization transfer (ihMT) contrast. METHODS: Amphiphilic lipids, lamellar phospholipids with cholesterol, and bovine spinal cord (BSC) specimens were examined along with nonlipid systems. Magnetization transfer (MT), enhanced MT (eMT, obtained with double-sided radiofrequency saturation), ihMT (MT - eMT), and dipolar relaxation, T1D , were measured at 2.0 and 11.7 T. RESULTS: The amplitude of ihMT ratio (ihMTR) is positively correlated with T1D values. Both ihMTR and T1D increase with increasing temperature in BSC white matter and in phospholipids and decrease with temperature in other lipids. Changes in ihMTR with temperature arise primarily from alterations in MT rather than eMT. Spectral width of MT, eMT, and ihMT increases with increasing carbon chain length. CONCLUSIONS: Concerted motions of phospholipids in white matter decrease proton spin diffusion leading to increased proton T1D times and increased ihMT amplitudes, consistent with decoupling of Zeeman and dipolar spin reservoirs. Molecular specificity and dynamic sensitivity of ihMT contrast make it a suitable candidate for probing myelin membrane disorders. Magn Reson Med 77:1318-1328, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Membrana Dobles de Lípidos/química , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Fosfolípidos/química , Sustancia Blanca/química , Animales , Bovinos , Difusión , Ensayo de Materiales , Protones , Temperatura
4.
J Ultrasound Med ; 35(2): 373-80, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26764276

RESUMEN

OBJECTIVES: Glomerular capillary hemorrhage can be induced by ultrasonic cavitation during contrast-enhanced diagnostic ultrasound (US) exposure, an important nonthermal US bioeffect. Recent studies of pulmonary US exposure have shown that thresholds for another nonthermal bioeffect of US, pulmonary capillary hemorrhage, is strongly influenced by whether xylazine is included in the specific anesthetic technique. The objective of this study was to determine the influence of xylazine on contrast-enhanced diagnostic US-induced glomerular capillary hemorrhage. METHODS: In this study, anesthesia with ketamine only was compared to ketamine plus xylazine for induction of glomerular capillary hemorrhage in rats by 1.6-MHz intermittent diagnostic US with a microsphere contrast agent (similar to Definity; Lantheus Medical Imaging, Inc, North Billerica, MA). Glomerular capillary hemorrhage was measured as a percentage of glomeruli with hemorrhage found in histologic sections for groups of rats scanned at different peak rarefactional pressure amplitudes. RESULTS: There was a significant difference between the magnitude of the glomerular capillary hemorrhage between the anesthetics at 2.3 MPa, with 45.6% hemorrhage for ketamine only, increasing to 63.2% hemorrhage for ketamine plus xylazine (P < .001). However, the thresholds for the two anesthetic methods were virtually identical at 1.0 MPa, based on linear regression of the exposure response data. CONCLUSIONS: Thresholds for contrast-enhanced diagnostic US-induced injury of the microvasculature appear to be minimally affected by anesthetic methods.


Asunto(s)
Anestesia/métodos , Anestésicos Disociativos , Capilares , Medios de Contraste/efectos adversos , Hemorragia/inducido químicamente , Ketamina , Glomérulos Renales/irrigación sanguínea , Ultrasonografía/efectos adversos , Xilazina , Animales , Ratas
5.
Opt Lett ; 40(10): 2253-6, 2015 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-26393712

RESUMEN

The feasibility of diagnostic imaging and tissue characterization based on a new contrast realized by dual-pulse photoacoustic measurement was studied. Unlike current photoacoustic methods which are mostly focused on the measurement of tissue optical absorption, this contrast revealed by a dual-pulse laser excitation process takes advantage of the temperature dependence of the Grüneisen parameter of tissue. The first laser pulse heats the sample and causes a temperature rise in the target tissue, which leads to a change of the Grüneisen parameter and the amplitude of the photoacoustic signal from the second laser pulse. This new contrast is then quantified by percentile change in the second pulse signal as a result of the first laser pulse. Since the temperature-dependent Grüneisen parameter is tissue specific and closely relevant to chemical and molecular properties of the sample, the dual-pulse photoacoustic measurement can differentiate various tissue types and conditions. The preliminary study on phantoms and a mouse model has suggested the capability of the proposed contrast in the characterization of fatty livers and the potential for future clinical diagnosis of liver conditions.


Asunto(s)
Hígado Graso/diagnóstico , Técnicas Fotoacústicas/métodos , Animales , Estudios de Factibilidad , Humanos , Rayos Láser , Ratones , Dinámicas no Lineales , Fantasmas de Imagen
6.
J Acoust Soc Am ; 135(1): 537-44, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24437794

RESUMEN

One application of acoustic droplet vaporization (ADV), a method of converting biocompatible microdroplets into microbubbles, is to enhance locally high intensity focused ultrasound (HIFU) therapy. Two objectives are pursued here: (1) the controlled creation of a bubble trench prior to HIFU using ADV and (2) use of the trench for increasing ablation volumes, lowering acoustic powers, and decreasing therapy duration. Thermally responsive phantoms were made with perfluorocarbon emulsion. Compound lesions were formed in a laboratory setting and a clinical magnetic resonance imaging (MRI)-guided HIFU system. Linear and spiral patterned compound lesions were generated in trenches. A larger fraction of the HIFU beam is contained to increase the generation of heat. Using the laboratory system, a 90 mm linear length spiral trench was formed in 30 s with mechanical beam steering. Comparatively, the clinical HIFU system formed a 19.9 mm linear length spiral trench in approximately 1 s with electronic beam steering. Lesions were imaged optically and with MRI. A uniform thermal ablation volume of 3.25 mL was achieved in 55.4 s (4-times faster than standard clinical HIFU and 14-times larger volume versus sum of individual lesions). Single lesions showed a 400% volume increase.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Medios de Contraste , Emulsiones , Fluorocarburos , Modelos Lineales , Imagen por Resonancia Magnética Intervencional/instrumentación , Microburbujas , Movimiento (Física) , Fantasmas de Imagen , Presión , Sonido , Factores de Tiempo , Volatilización
7.
J Control Release ; 374: 205-218, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39127447

RESUMEN

Hydrogels can serve as local drug delivery depots that protect the biological activity of labile therapeutics. However, drug release from conventional hydrogels is typically rapid, which is not ideal for many therapeutic agents. We developed a composite hydrogel that enables sustained drug release in response to ultrasound. The composite, termed an acoustically responsive scaffold (ARS), consists of a fibrin hydrogel and a phase-shift emulsion. Upon exposure to ultrasound, the emulsion is vaporized into bubbles, which leads to release of drugs contained within the emulsion. Previously, ARSs have been used in regenerative applications to stimulate blood vessel growth. Here, we characterize the release kinetics and mechanisms of ARSs. Release exhibits a triphasic pattern compromising a slow phase prior to ultrasound exposure; a transient, fast phase immediately after ultrasound exposure that follows a sigmoidal profile; and a sustained, steady phase. In each phase, we demonstrate how derived kinetics parameters are impacted by the ARS composition (e.g., fibrin and emulsion concentrations) and ultrasound properties (e.g., acoustic pressure, pulse duration). Using confocal microscopy, protein assays, and B-mode ultrasound imaging, we demonstrate that drug release from an ARS is independent of fibrin degradation and dependent on bubble growth. These results are critical in optimizing ARSs for delivery of therapeutic agents.


Asunto(s)
Preparaciones de Acción Retardada , Sistemas de Liberación de Medicamentos , Liberación de Fármacos , Fibrina , Hidrogeles , Hidrogeles/química , Cinética , Fibrina/química , Preparaciones de Acción Retardada/química , Emulsiones , Ondas Ultrasónicas , Acústica
8.
Ultrason Sonochem ; 103: 106754, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38252981

RESUMEN

Phase-shift droplets are a highly adaptable platform for biomedical applications of ultrasound. The spatiotemporal response of phase-shift droplets to focused ultrasound above a certain pressure threshold, termed acoustic droplet vaporization (ADV), is influenced by intrinsic features (e.g., bulk boiling point) and extrinsic factors (e.g., driving frequency and surrounding media). A deep understanding of ADV dynamics is critical to ensure the robustness and repeatability of an ADV-assisted application. Here, we integrated ultra-high-speed imaging, at 10 million frames per second, and confocal microscopy for a full-scale (i.e., from nanoseconds to seconds) characterization of ADV. Experiments were conducted in fibrin-based hydrogels to mimic soft tissue environments. Effects of fibrin concentration (0.2 to 8 % (w/v)), excitation frequency (1, 2.5, and 9.4 MHz), and perfluorocarbon core (perfluoropentane, perfluorohexane, and perfluorooctane) on ADV dynamics were studied. Several fundamental parameters related to ADV dynamics, such as expansion ratio, expansion velocity, collapse radius, collapse time, radius of secondary rebound, resting radius, and equilibrium radius of the generated bubbles were extracted from the radius vs time curves. Diffusion-driven ADV-bubble growth was fit to a modified Epstein-Plesset equation, adding a material stress term, to estimate the growth rate. Our results indicated that ADV dynamics were significantly impacted by fibrin concentration, frequency, and perfluorocarbon liquid core. This is the first study to combine ultra-high-speed and confocal microscopy techniques to provide insights into ADV bubble dynamics in tissue-mimicking hydrogels.


Asunto(s)
Fluorocarburos , Volatilización , Acústica , Hidrogeles , Fibrina
9.
Tissue Eng Part C Methods ; 30(3): 93-101, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38117158

RESUMEN

Angiogenesis induced by growth factor administration, which can augment the blood supply in regenerative applications, has drawn wide attention in medical research. Longitudinal monitoring of vascular structure and development in vivo is important for understanding and evaluating the dynamics of involved biological processes. In this work, a dual-modality imaging system consisting of photoacoustic microscopy (PAM) and optical coherence tomography (OCT) was applied for noninvasive in vivo imaging of angiogenesis in a murine model. Fibrin scaffolds, with and without basic fibroblast growth factor (bFGF), were implanted in a flexible imaging window and longitudinally observed over 9 days. Imaging was conducted at 3, 5, 7, and 9 days after implantation to monitor vascularization in and around the scaffold. Several morphometric parameters were derived from the PAM images, including vessel area density (VAD), total vessel length (TVL), and vessel mean diameter (VMD). On days 7 and 9, mice receiving bFGF-laden fibrin gels exhibited significantly larger VAD and TVL compared to mice with fibrin-only gels. In addition, VMD significantly decreased in +bFGF mice versus fibrin-only mice on days 7 and 9. Blood vessel density, evaluated using immunohistochemical staining of explanted gels and underlying tissue on day 9, corroborated the findings from the PAM images. Overall, the experimental results highlight the utility of a dual-modality imaging system in longitudinally monitoring of vasculature in vivo with high resolution and sensitivity, thereby providing an effective tool to study angiogenesis.


Asunto(s)
Angiogénesis , Neovascularización Fisiológica , Ratones , Animales , Microscopía , Geles , Fibrina/farmacología
10.
Ultrason Sonochem ; 109: 106984, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39018892

RESUMEN

Acoustic droplet vaporization (ADV) offers a dynamic approach for generating bubbles on demand, presenting new possibilities in biomedical applications. Although ADV has been investigated in various biomedical applications, its potential in tissue characterization remains unexplored. Here, we investigated the effects of surrounding media on the radial dynamics and acoustic emissions of ADV bubbles using theoretical and experimental methodologies. For theoretical studies, bubble dynamics were combined with the Kelvin-Voigt material constitutive model, accounting for viscoelasticity of the media. The radial dynamics and acoustic emissions of the ADV-bubbles were recorded via ultra-high-speed microscopy and passive cavitation detection, respectively. Perfluoropentane phase-shift droplets were embedded in tissue-mimicking hydrogels of varying fibrin concentrations, representing different elastic moduli. Radial dynamics and the acoustic emissions, both temporal and spectral, of the ADV-bubbles depended significantly on fibrin elastic modulus. For example, an increase in fibrin elastic modulus from ≈0.2 kPa to ≈6 kPa reduced the maximum expansion radius of the ADV-bubbles by 50%. A similar increase in the elastic modulus significantly impacted both linear (e.g., fundamental) and nonlinear (e.g., subharmonic) acoustic responses of the ADV-bubbles, by up to 10 dB. The sensitivity of ADV to the surrounding media was dependent on acoustic parameters such as driving pressure and the droplets concentration. Further analysis of the acoustic emissions revealed distinct ADV signal characteristics, which were significantly influenced by the surrounding media.


Asunto(s)
Acústica , Hidrogeles , Hidrogeles/química , Fenómenos Mecánicos , Módulo de Elasticidad , Volatilización , Fibrina/química , Materiales Biomiméticos/química
11.
J Control Release ; 375: 552-573, 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39276800

RESUMEN

Organic nanocrystals, particularly those composed of conjugated molecules, hold immense potential for various applications. However, their practical utility is often hindered by the challenge of achieving stable aqueous dispersions, which are essential for biological compatibility and effective delivery. This study introduces a novel and versatile strategy for preparing stable aqueous organic nanocrystals using a modified reprecipitation method. We demonstrate the broad applicability of this approach by successfully preparing a diverse library of nanocrystals from 27 conjugated molecules. Our findings reveal a charge-balanced aggregation mechanism for nanocrystal formation, highlighting the crucial role of surface charge in controlling particle size and stability. Based on this mechanism, we establish a comprehensive molecular combination strategy that directly links molecular properties to colloidal behaviour, enabling the straightforward prediction and preparation of stable aqueous dispersions without the need for excipients. This strategy provides a practical workflow for tailoring the functionality of these nanocrystals for a wide range of applications. To illustrate their therapeutic potential, we demonstrate the enhanced efficacy of these nanocrystals in treating acute ulcerative colitis, myocardial ischemia/reperfusion injury, and cancer in mouse models. This work paves the way for developing next-generation nanomaterials with tailored functionalities for diverse biomedical applications.

12.
Mol Imaging ; 12(8)2013.
Artículo en Inglés | MEDLINE | ID: mdl-24447615

RESUMEN

Viewing individual cells and ambient microvasculature simultaneously is crucial for understanding tumor angiogenesis and microenvironments. We developed a confocal fluorescence microscopy (CFM) and photoacoustic microscopy (PAM) dual-modality imaging system that can assess fluorescent contrast and optical absorption contrast in biologic samples simultaneously. After staining tissues with fluorescent dye at an appropriate concentration, each laser pulse can generate not only sufficient fluorescent signals from cells for CFM but also sufficient photoacoustic signals from microvessels for PAM. To explore the potential of this system for diagnosis of bladder cancer, experiments were conducted on a rat bladder model. The CFM image depicts the morphology of individual cells, showing not only large polygonal umbrella cells but also intracellular components. The PAM image acquired at the same time provides complementary information on the microvascular distribution in the bladder wall, ranging from large vessels to capillaries. This device provides an opportunity to realize both histologic assay and microvascular characterization simultaneously. The combination of the information of individual cells and local microvasculature in the bladder offers the capability of envisioning the viability and activeness of these cells and holds promise for more comprehensive study of bladder cancer in vivo.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Microvasos/citología , Vejiga Urinaria/irrigación sanguínea , Vejiga Urinaria/citología , Animales , Colorantes Fluorescentes , Humanos , Procesamiento de Imagen Asistido por Computador , Microscopía Confocal , Microscopía Fluorescente , Microvasos/ultraestructura , Técnicas Fotoacústicas , Ratas , Reproducibilidad de los Resultados , Vejiga Urinaria/ultraestructura
13.
J Acoust Soc Am ; 134(2): 1610-21, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23927201

RESUMEN

Acoustically sensitive emulsions are a promising tool for medical applications such as localized drug delivery. The physical mechanisms underlying the ultrasound-triggered nucleation and subsequent vaporization of these phase-change emulsions are largely unexplored. Here, the acoustic vaporization of individual micron-sized perfluoropentane (PFP) droplets is studied at a nanoseconds timescale. Highly diluted emulsions of PFP-in-water and oil-in-PFP-in-water droplets, ranging from 3.5 to 11 µm in radius, were prepared and the nucleation and growth of the vapor bubbles was imaged at frame rates of up to 20 Mfps. The droplet vaporization dynamics was observed to have three distinct regimes: (1) prior to nucleation, a regime of droplet deformation and oscillatory translations within the surrounding fluid along the propagation direction of the applied ultrasound; (2) a regime characterized by the rapid growth of a vapor bubble enhanced by ultrasound-driven rectified heat transfer; and (3) a final phase characterized by a relatively slow expansion, after ultrasound stops, that is fully dominated by heat transfer. A method to measure the moment of inception of the nucleation event with respect to the phase of the ultrasound wave is proposed. A simple physical model captures quantitatively all of the features of the subsequent vapor bubble growth.


Asunto(s)
Sistemas de Liberación de Medicamentos/métodos , Fluorocarburos/química , Sonido , Ultrasonido/métodos , Portadores de Fármacos , Emulsiones , Transferencia de Energía , Calor , Microscopía Acústica , Modelos Químicos , Movimiento (Física) , Oscilometría , Tamaño de la Partícula , Aceite de Soja/química , Factores de Tiempo , Volatilización , Agua/química
14.
Zhongguo Yi Liao Qi Xie Za Zhi ; 37(3): 169-72, 2013 May.
Artículo en Zh | MEDLINE | ID: mdl-24015607

RESUMEN

A small HIFU system was used to investigate the phase-shift droplet vaporization in vivo and its effect on thermal absorption in tissue-mimicking phantoms. The experiments demonstrated that droplets could be vaporized to bubbles in vivo by the small HIFU system and the volume of bubbles could increase by tens of times. With appropriate droplets concentration, lesion volume produced by HIFU could be increased significantly under the same HIFU parameter.


Asunto(s)
Fluorocarburos , Terapia por Ultrasonido/métodos , Aumento de la Imagen
15.
Z Med Phys ; 33(3): 387-406, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36775778

RESUMEN

The development of phase-shift droplets has broadened the scope of ultrasound-based biomedical applications. When subjected to sufficient acoustic pressures, the perfluorocarbon phase in phase-shift droplets undergoes a phase-transition to a gaseous state. This phenomenon, termed acoustic droplet vaporization (ADV), has been the subject of substantial research over the last two decades with great progress made in design of phase-shift droplets, fundamental physics of bubble nucleation and dynamics, and applications. Here, we review experimental approaches, carried out via high-speed microscopy, as well as theoretical models that have been proposed to study the fundamental physics of ADV including vapor nucleation and ADV-induced bubble dynamics. In addition, we highlight new developments of ADV in tissue regeneration, which is a relatively recently exploited application. We conclude this review with future opportunities of ADV for advanced applications such as in situ microrheology and pressure estimation.


Asunto(s)
Acústica , Modelos Teóricos , Volatilización , Ultrasonografía
16.
Ultrasound Med Biol ; 49(1): 136-151, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36244919

RESUMEN

The goal of this study was to evaluate ultrasound contrast microbubbles (MB) stability during a typical cystometrogram (CMG) for bladder pressure measurement application using the subharmonic-aided pressure estimation technique. A detailed study of MB stability was required given two unique characteristics of this application: first, bulk infusion of MBs into the bladder through the CMG infusion system, and second, duration of a typical CMG which may last up to 30 min. To do so, a series of size measurement and contrast-enhanced ultrasound imaging studies under different conditions were performed and the effects of variables that we hypothesized have an effect on MB stability, namely, i) IV bag air headspace, ii) MB dilution factor, and iii) CMG infusion system were investigated. The results verified that air volume in intravenous (IV) bag headspace was not enough to have a significant effect on MB stability during a CMG. We also showed that higher MB dosage results in a more stable condition. Finally, the results indicated that the CMG infusion system adversely affects MB stability. In summary, to ensure MB stability during the entire duration of a CMG, lower filling rates (limited by estimated bladder capacity in clinical applications) and/or higher MB dosage (limited by FDA regulations and shadowing artifact) and/or the consideration of alternative catheter design may be needed.


Asunto(s)
Microburbujas , Vejiga Urinaria , Vejiga Urinaria/diagnóstico por imagen , Ultrasonografía , Medios de Contraste , Pelvis
17.
Appl Phys Lett ; 123(11): 114101, 2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37705893

RESUMEN

Phase-shift droplets provide a flexible and dynamic platform for therapeutic and diagnostic applications of ultrasound. The spatiotemporal response of phase-shift droplets to focused ultrasound, via the mechanism termed acoustic droplet vaporization (ADV), can generate a range of bioeffects. Although ADV has been used widely in theranostic applications, ADV-induced bioeffects are understudied. Here, we integrated ultra-high-speed microscopy, confocal microscopy, and focused ultrasound for real-time visualization of ADV-induced mechanics and sonoporation in fibrin-based, tissue-mimicking hydrogels. Three monodispersed phase-shift droplets-containing perfluoropentane (PFP), perfluorohexane (PFH), or perfluorooctane (PFO)-with an average radius of ∼6 µm were studied. Fibroblasts and tracer particles, co-encapsulated within the hydrogel, were used to quantify sonoporation and mechanics resulting from ADV, respectively. The maximum radial expansion, expansion velocity, induced strain, and displacement of tracer particles were significantly higher in fibrin gels containing PFP droplets compared to PFH or PFO. Additionally, cell membrane permeabilization significantly depended on the distance between the droplet and cell (d), decreasing rapidly with increasing d. Significant membrane permeabilization occurred when d was smaller than the maximum radius of expansion. Both ultra-high-speed and confocal images indicate a hyper-local region of influence by an ADV bubble, which correlated inversely with the bulk boiling point of the phase-shift droplets. The findings provide insight into developing optimal approaches for therapeutic applications of ADV.

18.
Invest Radiol ; 58(3): 181-189, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36070543

RESUMEN

OBJECTIVES: The long-term goal of this study is to investigate the efficacy of a novel, ultrasound-based technique called subharmonic-aided pressure estimation (SHAPE) to measure bladder pressure as a part of a cystometrogram (CMG) in a urodynamic test (ie, pressure-flow study). SHAPE is based on the principle that subharmonic emissions from ultrasound contrast microbubbles (MBs) decrease linearly with an increase in ambient pressure. We hypothesize that, using the SHAPE technique, we can measure voiding bladder pressure catheter-free. This is of importance because the CMG catheter, due to its space-occupying property and non-physiological effects, can undermine the reliability of the test during voiding and cause misdiagnosis. In this study, we tested this hypothesis and optimized the protocol in a controlled benchtop environment. MATERIALS AND METHODS: A bladder phantom was designed and built, capable of simulating clinically relevant bladder pressures. Laboratory-made lipid-shelled MBs (similar in composition to the commercial agent, DEFINITY) was diluted in 0.9% normal saline and infused into the bladder phantom using the CMG infusion system. A typical simulated CMG consists of 1 filling and 4 post-filling events. During CMG events, the bladder phantom is pressurized multiple times at different clinically relevant levels (small, medium, and large) to simulate bladder pressures. Simultaneous with pressurization, MB subharmonic signal was acquired. For each event, the change in MB subharmonic amplitude was correlated linearly with the change in bladder phantom pressure, and the SHAPE conversion factor (slope of the linear fit) was determined. In doing so, a specific signal processing technique (based on a small temporal window) was used to account for time-decay of MB subharmonic signal during a simulated CMG. RESULTS: A strong inverse linear relationship was found to exist between SHAPE and bladder phantom pressures for each of the CMG filling and post-filling events ( r2> 0.9, root mean square error < 0.3 dB, standard error <0.01 dB, and P < 0.001). SHAPE showed a transient behavior in measuring bladder phantom pressure. The SHAPE conversion factor (in dB/cm H 2 O) varied between filling and post-filling events, as well as by post-filling time. The magnitude of the SHAPE conversion factor tended to increase immediately after filling and then decreases with time. CONCLUSIONS: Microbubble subharmonic emission is an excellent indicator of bladder phantom pressure variation. The strong correlation between SHAPE signal and bladder phantom pressure is indicative of the applicability of this method in measuring bladder pressure during a CMG. Our results suggest that different SHAPE conversion factors may be needed for different events during a CMG (ie, at different time points of a CMG). These findings will help us better protocolize this method for introduction into human subjects and allow us to take the next step toward developing a catheter-free voiding CMG using SHAPE.


Asunto(s)
Medios de Contraste , Vejiga Urinaria , Humanos , Vejiga Urinaria/diagnóstico por imagen , Reproducibilidad de los Resultados , Ultrasonografía/métodos , Fantasmas de Imagen , Microburbujas
19.
Acta Biomater ; 164: 195-208, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37121372

RESUMEN

Microporosity in hydrogels is critical for directing tissue formation and function. We have developed a fibrin-based smart hydrogel, termed an acoustically responsive scaffold (ARS), which responds to focused ultrasound in a spatiotemporally controlled, user-defined manner. ARSs are highly flexible platforms due to the inclusion of phase-shift droplets and their tunable response to ultrasound through a mechanism termed acoustic droplet vaporization (ADV). Here, we demonstrated that ADV enabled consistent generation of micropores in ARSs, throughout the entire thickness (∼5.5 mm), utilizing perfluorooctane phase-shift droplets. Size characteristics of the generated micropores were quantified in response to critical parameters including acoustic properties, droplet size, and shear elastic modulus of fibrin using confocal microscopy. The findings showed that the length of the generated micropores correlated directly with excitation frequency, peak rarefactional pressure, pulse duration, droplet size, and indirectly with the shear elastic modulus of the fibrin matrix. The ADV-generated micropores in ARSs were further compared with cavitation-mediated micropores in fibrin gels without droplets. Additionally, the Keller-Miksis equation was used to predict an upper bound for micropore formation in ARSs at varying driving frequencies and droplet sizes. Finally, our in vivo studies showed that host cell migration following ADV-induced micropore formation was frequency-dependent, with up to 2.6 times higher cell migration at lower frequencies. Overall, these findings demonstrate a new potential application of ADV in hydrogels. STATEMENT OF SIGNIFICANCE: Interconnected micropores within a hydrogel can facilitate many cell-mediated processes. Most techniques for generating micropores are typically not biocompatible or do not enable controlled, in situ micropore formation. We used an ultrasound-based technique, termed acoustic droplet vaporization, to generate microporosity in smart hydrogels termed acoustically responsive scaffolds (ARSs). ARSs contain a fibrin matrix doped with a phase-shift droplet. We demonstrate that unique acoustic properties of phase-shift droplets can be tailored to yield spatiotemporally controlled, on-demand micropore formation. Additionally, the size characteristics of the ultrasound-generated micropores can be modulated by tuning ultrasound parameters, droplet properties, and bulk elastic properties of fibrin. Finally, we demonstrate significant, frequency-dependent host cell migration in subcutaneously implanted ARSs in mice following ultrasound-induced micropore formation in situ.


Asunto(s)
Acústica , Hidrogeles , Animales , Ratones , Volatilización , Andamios del Tejido , Fibrina
20.
Microcirculation ; 19(6): 501-9, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22404846

RESUMEN

OBJECTIVE: Embolotherapy is a potential means to treat a variety of cancers. Our approach-gas embolotherapy-introduces the droplets upstream from the tumor and then acoustically activates them to form bubbles for occlusion-a process known as ADV. We wanted to provide the first optical documentation of ADV, lodged bubbles, or vessel occlusion in vivo. METHODS: We used the rat cremaster muscle for in vivo microscopy. Perfluorocarbon droplets were administered into the aortic arch. Ultrasound exposures in the cremaster induced vaporization. The cremaster was examined pre- and post-exposure for ADV-related effects. Two sets of experiments compared the effect of exposure in the capillaries versus the first order arteriole. RESULTS: Bubbles that lodge following capillary exposure are significantly larger (76 µm mean length, 36 µm mean diameter) than those following feeder vessel exposure (25 µm mean length, 11 µm mean diameter). Despite the differing sizes in bubbles, the ratio of bubble length to the hydraulic diameter of all lodged bubbles was 2.11 (±0.65; n = 112), which agrees with theoretical predictions and experimental observations. CONCLUSIONS: Our results provide the first optical evidence of targeted vessel occlusion through ADV. These findings could lay the groundwork for the advancement of gas embolotherapy.


Asunto(s)
Capilares , Embolización Terapéutica/métodos , Fluorocarburos/farmacología , Músculo Esquelético/irrigación sanguínea , Sonido , Animales , Embolización Terapéutica/instrumentación , Masculino , Microscopía , Ratas , Ratas Sprague-Dawley , Volatilización
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA