Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nature ; 617(7961): 592-598, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37011668

RESUMEN

The primary two-dose SARS-CoV-2 mRNA vaccine series are strongly immunogenic in humans, but the emergence of highly infectious variants necessitated additional doses and the development of vaccines aimed at the new variants1-4. SARS-CoV-2 booster immunizations in humans primarily recruit pre-existing memory B cells5-9. However, it remains unclear whether the additional doses induce germinal centre reactions whereby re-engaged B cells can further mature, and whether variant-derived vaccines can elicit responses to variant-specific epitopes. Here we show that boosting with an mRNA vaccine against the original monovalent SARS-CoV-2 mRNA vaccine or the bivalent B.1.351 and B.1.617.2 (Beta/Delta) mRNA vaccine induced robust spike-specific germinal centre B cell responses in humans. The germinal centre response persisted for at least eight weeks, leading to significantly more mutated antigen-specific bone marrow plasma cell and memory B cell compartments. Spike-binding monoclonal antibodies derived from memory B cells isolated from individuals boosted with either the original SARS-CoV-2 spike protein, bivalent Beta/Delta vaccine or a monovalent Omicron BA.1-based vaccine predominantly recognized the original SARS-CoV-2 spike protein. Nonetheless, using a more targeted sorting approach, we isolated monoclonal antibodies that recognized the BA.1 spike protein but not the original SARS-CoV-2 spike protein from individuals who received the mRNA-1273.529 booster; these antibodies were less mutated and recognized novel epitopes within the spike protein, suggesting that they originated from naive B cells. Thus, SARS-CoV-2 booster immunizations in humans induce robust germinal centre B cell responses and can generate de novo B cell responses targeting variant-specific epitopes.


Asunto(s)
Linfocitos B , Vacunas contra la COVID-19 , COVID-19 , Centro Germinal , Inmunización Secundaria , Humanos , Anticuerpos Monoclonales/inmunología , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , COVID-19/inmunología , COVID-19/prevención & control , COVID-19/virología , Vacunas contra la COVID-19/administración & dosificación , Vacunas contra la COVID-19/inmunología , SARS-CoV-2/genética , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/genética , Glicoproteína de la Espiga del Coronavirus/inmunología , Linfocitos B/citología , Linfocitos B/inmunología , Centro Germinal/citología , Centro Germinal/inmunología , Células Plasmáticas/citología , Células Plasmáticas/inmunología , Células B de Memoria/citología , Células B de Memoria/inmunología , Epítopos de Linfocito B/genética , Epítopos de Linfocito B/inmunología
2.
Clin Chem ; 70(2): 444-452, 2024 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-38084963

RESUMEN

BACKGROUND: Intravenous (IV) fluid contamination is a common cause of preanalytical error that can delay or misguide treatment decisions, leading to patient harm. Current approaches for detecting contamination rely on delta checks, which require a prior result, or manual technologist intervention, which is inefficient and vulnerable to human error. Supervised machine learning may provide a means to detect contamination, but its implementation is hindered by its reliance on expert-labeled training data. An automated approach that is accurate, reproducible, and practical is needed. METHODS: A total of 25 747 291 basic metabolic panel (BMP) results from 312 721 patients were obtained from the laboratory information system (LIS). A Uniform Manifold Approximation and Projection (UMAP) model was trained and tested using a combination of real patient data and simulated IV fluid contamination. To provide an objective metric for classification, an "enrichment score" was derived and its performance assessed. Our current workflow was compared to UMAP predictions using expert chart review. RESULTS: UMAP embeddings from real patient results demonstrated outliers suspicious for IV fluid contamination when compared with the simulated contamination's embeddings. At a flag rate of 3 per 1000 results, the positive predictive value (PPV) was adjudicated to be 0.78 from 100 consecutive positive predictions. Of these, 58 were previously undetected by our current clinical workflows, with 49 BMPs displaying a total of 56 critical results. CONCLUSIONS: Accurate and automatable detection of IV fluid contamination in BMP results is achievable without curating expertly labeled training data.


Asunto(s)
Aprendizaje Automático no Supervisado , Humanos , Valor Predictivo de las Pruebas , Flujo de Trabajo
3.
Clin Chem Lab Med ; 62(5): 929-938, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38044587

RESUMEN

OBJECTIVES: Free light chain (FLC) assays and the ratio of κ/λ are recommended for diagnosis, prognosis and monitoring of plasma cell dyscrasias (PCD). Limited data exists on FLC clinical specificity in patients diagnosed with other conditions. METHODS: We assessed the κ, λ, and κ/λ FLC ratio using the FreeLite assay and the Sebia FLC ELISA assay in 176 patients with clinical presentations of fatigue, anemia, polyclonal hypergammaglobulinemia, joint disorders, kidney disease and non PCD-cancers with no monoclonal protein observed on serum protein electrophoresis or MASS-FIX immunoglobulin isotyping. Manufacturer defined reference intervals (RI) and glomerular filtration rate (GFR) specific RI (renal RI) were utilized. RESULTS: For the κ/λ ratio, 68.7 % (121/176) of specimens on the FreeLite and 87.5 % (154/176) of specimens on the Sebia assay were within RI. For κ, 68.2 % (120/176) and 72.2 % (127/176) of results were outside RI for FreeLite and Sebia respectively. For λ, 37.5 % (66/176) and 84.1 % (148/176) of FreeLite and Sebia results were outside RI. With FreeLite and Sebia, patients with kidney disease (n=25) had the highest κ/λ ratios. 44 patients (25.0 %) had GFR <60 mL/min/BSA. When renal RI were applied, 13.6 % had a FLCr outside the renal RI with FreeLite, and 4.5 % with Sebia. CONCLUSIONS: In a cohort of patients with signs and symptoms suggestive of PCDs, but ultimately diagnosed with other conditions, Sebia FLC had improved clinical specificity relative to FreeLite, if one was using an abnormal κ/λ ratio as a surrogate for monoclonality.


Asunto(s)
Enfermedades Renales , Paraproteinemias , Humanos , Cadenas kappa de Inmunoglobulina , Cadenas lambda de Inmunoglobulina , Cadenas Ligeras de Inmunoglobulina , Paraproteinemias/diagnóstico
4.
Clin Chem ; 2023 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-37205831

RESUMEN

BACKGROUND: The use of quantitative human chorionic gonadotropin (hCG) as a tumor marker is widely accepted despite lack of FDA-approval for oncology. Differences in iso- and glycoform recognition among hCG immunoassays is well established, exhibiting wide inter-method variability. Here, we assess the utility of 5 quantitative hCG immunoassays for use as tumor markers in trophoblastic and non-trophoblastic disease. METHODS: Remnant specimens were obtained from 150 patients with gestational trophoblastic disease (GTD), germ cell tumors (GCT), or other malignancies. Specimens were identified by review of results from physician-ordered hCG and tumor marker testing. Five analyzer platforms were used for split specimen analysis of hCG: Abbott Architect Total, Roche cobas STAT, Roche cobas Total, Siemens Dimension Vista Total, and Beckman Access Total. RESULTS: Frequency of elevated hCG concentrations (above reference cutoffs) was highest in GTD (100%), followed by GCT (55% to 57%), and other malignancies (8% to 23%). Overall, the Roche cobas Total detected elevated hCG in the greatest number of specimens (63/150). Detection of elevated hCG in trophoblastic disease was nearly equivalent among all immunoassays (range, 41 to 42/60). CONCLUSIONS: While no immunoassay is likely to be perfect in all clinical situations, results for the 5 hCG immunoassays evaluated suggest that all are adequate for use of hCG as a tumor marker in gestational trophoblastic disease and select germ cell tumors. Further harmonization of hCG methods is needed as serial testing for biochemical tumor monitoring must still be performed using a single method. Additional studies are needed to assess the utility of quantitative hCG as a tumor marker in other malignant disease.

5.
Transfusion ; 61(9): 2658-2667, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34216156

RESUMEN

BACKGROUND: The COVID-19 pandemic has been accompanied by the largest mobilization of therapeutic convalescent plasma (CCP) in over a century. Initial identification of high titer units was based on dose-response data using the Ortho VITROS IgG assay. The proliferation of severe acute respiratory syndrome coronavirus 2 serological assays and non-uniform application has led to uncertainty about their interrelationships. The purpose of this study was to establish correlations and analogous cutoffs between multiple serological assays. METHODS: We compared the Ortho, Abbott, Roche, an anti-spike (S) ELISA, and a virus neutralization assay. Relationships relative to FDA-approved cutoffs under the CCP emergency use authorization were identified in convalescent plasma from a cohort of 79 donors from April 2020. RESULTS: Relative to the neutralization assay, the spearman r value of the Ortho Clinical, Abbott, Roche, anti-S ELISA assays was 0.65, 0.59, 0.45, and 0.76, respectively. The best correlative index for establishing high-titer units was 3.87 signal-to-cutoff (S/C) for the Abbott, 13.82 cutoff index for the Roche, 1:1412 for the anti-S ELISA, 1:219 by the neutralization assay, and 15.9 S/C by the Ortho Clinical assay. The overall agreement using derived cutoffs compared to a neutralizing titer of 1:250 was 78.5% for Abbott, 74.7% for Roche, 83.5% for the anti-S ELISA, and 78.5% for Ortho Clinical. DISCUSSION: Assays based on antibodies against the nucleoprotein were positively associated with neutralizing titers and the Ortho assay, although their ability to distinguish FDA high-titer specimens was imperfect. The resulting relationships help reconcile results from the large body of serological data generated during the COVID-19 pandemic.


Asunto(s)
Anticuerpos Antivirales/inmunología , COVID-19/epidemiología , COVID-19/inmunología , SARS-CoV-2/inmunología , Adulto , Anciano , Anticuerpos Neutralizantes/sangre , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/sangre , COVID-19/sangre , COVID-19/terapia , Prueba Serológica para COVID-19 , Comorbilidad , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Inmunización Pasiva , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Seroepidemiológicos , Adulto Joven , Sueroterapia para COVID-19
6.
Clin Chem ; 66(9): 1190-1199, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32870987

RESUMEN

BACKGROUND: Every clinical specimen is potentially infectious, but data regarding risk for contamination of the laboratory environment during routine testing are scarce. We assessed contamination during routine sample analysis in automated clinical chemistry and microbiology laboratories. METHODS: A fluorescent marker was applied to specimen container exteriors to assess the impact of gross contamination. Nonpathogenic MS2 virus was added to remnant blood, urine, and ESwab matrices as a biomarker of cross-contamination. Samples were processed and analyzed using Roche Cobas 8100 and ISE, c502, e602, and c702 modules (blood) and BD Kiestra total laboratory automation (blood, urine, ESwabs) over 3 experiments. Fluorescence transfer to laboratory surfaces and personnel was visualized using ultraviolet light. Surfaces were swabbed and assessed for MS2 cross-contamination by RT-PCR. Adherence to standard precautions by laboratory staff was assessed by observation. RESULTS: Fluorescence was observed on 49 of 165 (30%) laboratory surfaces and personnel and 21 of 93 (23%) total laboratory automation instruments. Fluorescence transferred most frequently to gloves (31/40), computer accessories (9/18), and specimen loading racks (12/12). None of 123 areas swabbed were positive for MS2. Improper personal protective equipment use occurred at a rate of 0.36 and 0.15 events per staff per hour in the chemistry and microbiology laboratories, respectively. Hand-washing compliance was observed for 61 of 132 (46%) staff members evaluated. CONCLUSIONS: Analysis of grossly contaminated specimens on automated chemistry and microbiology equipment elicits a low likelihood of instrument contamination. However, handling contaminated specimen containers can result in contamination of environmental laboratory surfaces, representing a source of risk that is heightened by low adherence to appropriate personal protective equipment.


Asunto(s)
Automatización de Laboratorios/instrumentación , Contaminación de Equipos , Fómites/virología , Técnicas de Laboratorio Clínico/instrumentación , Técnicas de Laboratorio Clínico/métodos , Fluorescencia , Colorantes Fluorescentes/química , Higiene de las Manos , Humanos , Laboratorios , Levivirus , Técnicas Microbiológicas/instrumentación , Técnicas Microbiológicas/métodos , Medición de Riesgo , Manejo de Especímenes
7.
Clin Chem ; 66(8): 1055-1062, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32402061

RESUMEN

BACKGROUND: The recent emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in a rapid proliferation of serologic assays. However, little is known about their clinical performance. Here, we compared two commercial SARS-CoV-2 IgG assays. METHODS: 103 specimens from 48 patients with PCR-confirmed SARS-CoV-2 infections and 153 control specimens were analyzed using SARS-CoV-2 serologic assays by Abbott and EUROIMMUN (EI). Duration from symptom onset was determined by medical record review. Diagnostic sensitivity, specificity, and concordance were calculated. RESULTS: The Abbott SARS-CoV-2 assay had a diagnostic specificity of 99.4% (95% CI; 96.41-99.98%), and sensitivity of 0.0% (95% CI; 0.00-26.47%) at <3 days post symptom onset, 30.0% (95% CI; 11.89-54.28) at 3-7d, 47.8% (95% CI; 26.82-69.41) at 8-13d and 93.8% (95% CI; 82.80-98.69) at ≥14d. Diagnostic specificity on the EI assay was 94.8% (95% CI; 89.96-97.72) if borderline results were considered positive and 96.7% (95% CI; 92.54-98.93) if borderline results were considered negative. The diagnostic sensitivity was 0.0% (95% CI; 0.00-26.47%) at <3d, 25.0% (95% CI; 8.66-49.10) at 3-7d, 56.5% (95% CI; 34.49-76.81) at 3-7d and 85.4% (95% CI; 72.24-93.93) at ≥14d if borderline results were considered positive. The qualitative concordance between the assays was 0.83 (95% CI; 0.75-0.91). CONCLUSION: The Abbott SARS-CoV-2 assay had fewer false positive and false negative results than the EI assay. However, diagnostic sensitivity was poor in both assays during the first 14 days of symptoms.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/inmunología , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Anticuerpos Antivirales/inmunología , Betacoronavirus/aislamiento & purificación , COVID-19 , Infecciones por Coronavirus/virología , Reacciones Falso Positivas , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Inmunoglobulina G/análisis , Inmunoglobulina G/inmunología , Pandemias , Neumonía Viral/virología , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , SARS-CoV-2 , Sensibilidad y Especificidad , Factores de Tiempo
8.
Clin Chem ; 66(12): 1538-1547, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-32894750

RESUMEN

BACKGROUND: Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. METHODS: Sixty-six specimens from 48 patients with PCR-confirmed COVID-19 and a positive result by the Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, or EUROIMMUN SARS-CoV-2 IgG assays and 5 control specimens were analyzed for the presence of neutralizing antibodies to SARS-CoV-2. Correlation, concordance, positive percent agreement (PPA), and negative percent agreement (NPA) were calculated at several cutoffs. Results were compared in patients categorized by clinical outcomes. RESULTS: The correlation between SARS-CoV-2 neutralizing titer (EC50) and the Roche, Abbott, and EUROIMMUN assays was 0.29, 0.47, and 0.46, respectively. At an EC50 of 1:32, the concordance kappa with Roche was 0.49 (95% CI; 0.23-0.75), with Abbott was 0.52 (0.28-0.77), and with EUROIMMUN was 0.61 (0.4-0.82). At the same neutralizing titer, the PPA and NPA for the Roche was 100% (94-100) and 56% (30-80); Abbott was 96% (88-99) and 69% (44-86); and EUROIMMUN was 91% (80-96) and 81% (57-93) for distinguishing neutralizing antibodies. Patients who were intubated, had cardiac injury, or acute kidney injury from COVID-19 infection had higher neutralizing titers relative to those with mild symptoms. CONCLUSIONS: COVID-19 patients generate an antibody response to multiple viral proteins such that the calibrator ratios on the Roche, Abbott, and EUROIMMUN assays are all associated with SARS-CoV-2 neutralization. Nevertheless, commercial serological assays have poor NPA for SARS-CoV-2 neutralization, making them imperfect proxies for neutralization.


Asunto(s)
Anticuerpos Neutralizantes/análisis , Anticuerpos Antivirales/análisis , Prueba Serológica para COVID-19/estadística & datos numéricos , COVID-19/inmunología , Inmunoensayo/estadística & datos numéricos , SARS-CoV-2/inmunología , Anciano , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , COVID-19/epidemiología , Proteínas de la Nucleocápside de Coronavirus/inmunología , Correlación de Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fosfoproteínas/inmunología , Curva ROC , SARS-CoV-2/química , Índice de Severidad de la Enfermedad , Glicoproteína de la Espiga del Coronavirus/inmunología
9.
J Immunol ; 201(2): 560-572, 2018 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-29858265

RESUMEN

Obese patients with type 2 diabetes (T2D) are at an increased risk of foot infection, with impaired immune function believed to be a critical factor in the infectious process. In this study, we test the hypothesis that humoral immune defects contribute to exacerbated foot infection in a murine model of obesity/T2D. C57BL/6J mice were rendered obese and T2D by a high-fat diet for 3 mo and were compared with controls receiving a low-fat diet. Following injection of Staphylococcus aureus into the footpad, obese/T2D mice had greater foot swelling and reduced S. aureus clearance than controls. Obese/T2D mice also had impaired humoral immune responses as indicated by lower total IgG levels and lower anti-S. aureus Ab production. Within the draining popliteal lymph nodes of obese/T2D mice, germinal center formation was reduced, and the percentage of germinal center T and B cells was decreased by 40-50%. Activation of both T and B lymphocytes was similarly suppressed in obese/T2D mice. Impaired humoral immunity in obesity/T2D was independent of active S. aureus infection, as a similarly impaired humoral immune response was demonstrated when mice were administered an S. aureus digest. Isolated splenic B cells from obese/T2D mice activated normally but had markedly suppressed expression of Aicda, with diminished IgG and IgE responses. These results demonstrate impaired humoral immune responses in obesity/T2D, including B cell-specific defects in Ab production and class-switch recombination. Together, the defects in humoral immunity may contribute to the increased risk of foot infection in obese/T2D patients.


Asunto(s)
Linfocitos B/fisiología , Diabetes Mellitus Tipo 2/inmunología , Pie/microbiología , Centro Germinal/inmunología , Obesidad/inmunología , Infecciones Estafilocócicas/inmunología , Staphylococcus aureus/inmunología , Animales , Diferenciación Celular , Células Cultivadas , Citidina Desaminasa/metabolismo , Diabetes Mellitus Tipo 2/microbiología , Dieta Alta en Grasa , Modelos Animales de Enfermedad , Progresión de la Enfermedad , Pie/patología , Humanos , Inmunidad Humoral , Cambio de Clase de Inmunoglobulina , Masculino , Ratones , Ratones Endogámicos C57BL , Obesidad/microbiología , Infecciones Estafilocócicas/microbiología
10.
J Bacteriol ; 201(9)2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30782631

RESUMEN

Staphylococcus aureus causes a wide spectrum of disease, with the site and severity of infection dependent on virulence traits encoded within genetically distinct clonal complexes (CCs) and bacterial responses to host innate immunity. The production of nitric oxide (NO) by activated phagocytes is a major host response to which S. aureus metabolically adapts through multiple strategies that are conserved in all CCs, including an S. aureus nitric oxide synthase (Nos). Previous genome analysis of CC30, a lineage associated with chronic endocardial and osteoarticular infections, revealed a putative NO reductase (Nor) not found in other CCs that potentially contributes to NO resistance and clinical outcome. Here, we demonstrate that Nor has true nitric oxide reductase activity, with nor expression enhanced by NO stress and anaerobic growth. Furthermore, we demonstrate that nor is regulated by MgrA and SrrAB, which modulate S. aureus virulence and hypoxic response. Transcriptome analysis of the S. aureus UAMS-1, UAMS-1 Δnor, and UAMS-1 Δnos strains under NO stress and anaerobic growth demonstrates that Nor contributes to nucleotide metabolism and Nos to glycolysis. We demonstrate that Nor and Nos contribute to enhanced survival in the presence of human human polymorphonuclear cells and have organ-specific seeding in a tail vein infection model. Nor contributes to abscess formation in an osteological implant model. We also demonstrate that Nor has a role in S. aureus metabolism and virulence. The regulation overlap between Nor and Nos points to an intriguing link between regulation of intracellular NO, metabolic adaptation, and persistence in the CC30 lineage.IMPORTANCEStaphylococcus aureus can cause disease at most body sites, and illness spans asymptomatic infection to death. The variety of clinical presentations is due to the diversity of strains, which are grouped into distinct clonal complexes (CCs) based on genetic differences. The ability of S. aureus CC30 to cause chronic infections relies on its ability to evade the oxidative/nitrosative defenses of the immune system and survive under different environmental conditions, including differences in oxygen and nitric oxide concentrations. The significance of this work is the exploration of unique genes involved in resisting NO stress and anoxia. A better understanding of the functions that control the response of S. aureus CC30 to NO and oxygen will guide the treatment of severe disease presentations.


Asunto(s)
Regulación Bacteriana de la Expresión Génica , Óxido Nítrico Sintasa/metabolismo , Óxido Nítrico/metabolismo , Oxidorreductasas/metabolismo , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/enzimología , Staphylococcus aureus/metabolismo , Anaerobiosis , Animales , Modelos Animales de Enfermedad , Glucólisis , Interacciones Huésped-Patógeno , Humanos , Modelos Teóricos , Staphylococcus aureus/crecimiento & desarrollo , Virulencia
11.
Clin Chem ; 65(5): 694-702, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30808643

RESUMEN

BACKGROUND: Pneumatic tube systems (PTSs) provide rapid transport of patient blood samples, but physical stress of PTS transport can damage blood cells and alter test results. Despite this knowledge, there is limited information on how to validate a hospital PTS. METHODS: We compared 2 accelerometers and evaluated multiple PTS routes. Variabilities in PTS forces over the same routes were assessed. Response curves that demonstrate the relationship between the number and magnitude of accelerations on plasma lactate dehydrogenase (LD), hemolysis index, and potassium in PTS-transported blood from volunteers were generated. Extrapolations from these relationships were used to predict PTS routes that may be prone to false laboratory results. Historical data and prospective patient studies were compared with predicted effects. RESULTS: The maximum recorded g-force was 10g for the smartphone and 22g for the data logger. There was considerable day-to-day variation in the magnitude of accelerations (CV, 4%-39%) within a single route. The linear relationship between LD and accelerations within the PTS revealed 2 PTS routes predicted to increase LD by ≥20%. The predicted increase in LD was similar to that observed in patient results when using that PTS route. CONCLUSIONS: Hospital PTSs can be validated by documenting the relationship between the concentrations of analytes in plasma, such as LD, with PTS forces recorded by 3-axis accelerometers. Implementation of this method for PTS validation is relatively inexpensive, simple, and robust.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Laboratorios de Hospital/organización & administración , Manejo de Especímenes/métodos , Acelerometría/instrumentación , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Teléfono Inteligente
15.
Infect Immun ; 85(6)2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28320836

RESUMEN

Obesity and associated type 2 diabetes (T2D) are important risk factors for infection following orthopedic implant surgery. Staphylococcus aureus, the most common pathogen in bone infections, adapts to multiple environments to survive and evade host immune responses. Whether adaptation of S. aureus to the unique environment of the obese/T2D host accounts for its increased virulence and persistence in this population is unknown. Thus, we assessed implant-associated osteomyelitis in normal versus high-fat-diet obese/T2D mice and found that S. aureus infection was more severe, including increases in bone abscesses relative to nondiabetic controls. S. aureus isolated from bone of obese/T2D mice displayed marked upregulation of four adhesion genes (clfA, clfB, bbp, and sdrC), all with binding affinity for fibrin(ogen). Immunostaining of infected bone revealed increased fibrin deposition surrounding bacterial abscesses in obese/T2D mice. In vitro coagulation assays demonstrated a hypercoagulable state in obese/T2D mice that was comparable to that of diabetic patients. S. aureus with an inactivating mutation in clumping factor A (clfA) showed a reduction in bone infection severity that eliminated the effect of obesity/T2D, while infections in control mice were unchanged. In infected mice that overexpress plasminogen activator inhibitor-1 (PAI-1), S. aureusclfA expression and fibrin-encapsulated abscess communities in bone were also increased, further linking fibrin deposition to S. aureus expression of clfA and infection severity. Together, these results demonstrate an adaptation by S. aureus to obesity/T2D with increased expression of clfA that is associated with the hypercoagulable state of the host and increased virulence of S. aureus.


Asunto(s)
Coagulasa/metabolismo , Diabetes Mellitus Tipo 2/complicaciones , Obesidad/complicaciones , Osteomielitis/patología , Infecciones Estafilocócicas/microbiología , Absceso/patología , Animales , Anticuerpos Antibacterianos/genética , Anticuerpos Antibacterianos/metabolismo , Coagulasa/genética , Diabetes Mellitus Tipo 2/microbiología , Modelos Animales de Enfermedad , Fibrinógeno/metabolismo , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Obesidad/microbiología , Osteomielitis/microbiología , Análisis de Secuencia de ARN , Activación Transcripcional , Regulación hacia Arriba , Virulencia
16.
Clin Chem ; 68(2): 372-373, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36103295
20.
Infect Immun ; 83(6): 2264-74, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25802056

RESUMEN

Obesity and diabetes are among the greatest risk factors for infection following total joint arthroplasty. However, the underlying mechanism of susceptibility is unclear. We compared orthopedic implant-associated Staphylococcus aureus infections in type 1 (T1D) versus type 2 (T2D) diabetic mouse models and in patients with S. aureus infections, focusing on the adaptive immune response. Mice were fed a high-fat diet to initiate obesity and T2D. T1D was initiated with streptozotocin. Mice were then given a trans-tibial implant that was precoated with bioluminescent Xen36 S. aureus. Although both mouse models of diabetes demonstrated worse infection severity than controls, infection in T2D mice was more severe, as indicated by increases in bioluminescence, S. aureus CFU in tissue, and death within the first 7 days. Furthermore, T2D mice had an impaired humoral immune response at day 14 with reduced total IgG, decreased S. aureus-specific IgG, and increased IgM. These changes were not present in T1D mice. Similarly, T2D patients and obese nondiabetics with active S. aureus infections had a blunted IgG response to S. aureus. In conclusion, we report the first evidence of a humoral immune deficit, possibly due to an immunoglobulin class switch defect, in obesity and T2D during exacerbated S. aureus infection which may contribute to the increased infection risk following arthroplasty in patients with T2D and obesity.


Asunto(s)
Diabetes Mellitus Experimental/inmunología , Diabetes Mellitus Tipo 1/inmunología , Diabetes Mellitus Tipo 2/inmunología , Inmunidad Humoral , Obesidad/inmunología , Infecciones Estafilocócicas/microbiología , Inmunidad Adaptativa , Animales , Intolerancia a la Glucosa , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Obesidad/inducido químicamente , Osteomielitis/microbiología , Staphylococcus aureus
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA