Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Rapid Commun Mass Spectrom ; 25(21): 3281-8, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22006391

RESUMEN

A miniature mass spectrometer capable of detecting analytes eluting from a high-performance liquid chromatography (HPLC) system is described and demonstrated for the first time. The entire instrument, including all pumps and the computer, is contained within a single enclosure that may be conveniently accommodated at the base of the HPLC stack. The microspray ion source, vacuum interface, ion guide, and quadrupole ion filter are all microengineered. These components are fabricated in batches using microelectromechanical systems (MEMS) techniques and considered to be consumables. When coupled to a standard HPLC system using an integrated passive split, the limit of detection for reserpine while scanning the full mass range is 5 ng on-column (1 pg of which is passed to the microspray). The mass range is m/z 100-800, and each spectrum is typically acquired at a rate of 1 scan per second.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/instrumentación , Sistemas Microelectromecánicos/instrumentación , Miniaturización/instrumentación , Espectrometría de Masas/métodos , Modelos Químicos , Reserpina/análisis , Sensibilidad y Especificidad
2.
Anal Chem ; 82(5): 1751-8, 2010 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-20108919

RESUMEN

Two miniature mass spectrometer systems based on a microengineered quadrupole mass filter have been developed. One of the instruments has a footprint of 27 cm x 20 cm and is intended for laboratory use when space is at a premium. The other is portable and intended for use in the field. It is battery powered, weighs 14.9 kg, and is housed in a rugged case. This is the first example of a portable mass spectrometer incorporating an analyzer fabricated using microelectromechanical systems (MEMS) techniques. The starting material for construction of the filters is a bonded silicon on insulator substrate, which is selectively etched using batch processing techniques to form coupling optics and springs that accurately hold 0.5 mm diameter stainless steel rods in the required geometry. Assembled filters measure 35 mm x 6 mm x 1.5 mm and are mounted, together with an ion source and channeltron detector, in small, interchangeable cartridges, which plug into a 220 cm(3) vacuum chamber. Recovery from accidental contamination or when servicing is required can be achieved within 5-10 min, as the cartridge is easily exchanged with a spare. A potential application to environmental monitoring has been investigated. The headspace above water spiked with dibutyl mercaptan was sampled with a solid phase microextraction (SPME) fiber, which was then injected directly into the vacuum chamber of the mass spectrometer. Using this method, the limit of detection was found to be approximately 5 ppm for a 15 s sampling period.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA