Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 92(5): 972-980, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29726601

RESUMEN

OBJECTIVES: Temporally quantify and localize paravalvular aortic leak (PVL) after transcatheter aortic valve replacement (TAVR) in the Medtronic CoreValve (MCV) versus the Edwards Sapien Valve (ESV). BACKGROUND: In order to increase the precision of THV selection and PVL intervention, an understanding of PVL characteristics is essential. METHODS: The frequency, severity, and location of post-TAVR PVL were evaluated with transthoracic echocardiography pre-discharge, one month, and one-year post-procedure in 202 patients receiving a MCV (N = 120) or ESV (N = 81). This was done through application of a clock face to the short axis of the aortic valve in order to divide the area into three tertiles. RESULTS: Pre-discharge differences between PVL frequency and severity in the MCV and ESV lost significance over time. Localizing these trends, MCV PVL frequency and severity significantly decreased in the first and third tertiles during most time periods while PVL in the second tertile of the MCV or in any of the tertiles of the ESV failed to improve. Presence of pre-discharge PVL was predictive of 30-day HF readmission and/or death (OR = 3.16, 95% CI: 0.99-10.12). Presence of pre-discharge and 30-day PVL was predictive of 1-year HF readmissions and/or death (OR = 2.12, 95% CI: 1.09-4.13 and OR = 1.99, 95% CI: 0.96-4.12). CONCLUSIONS: When comparing the MCV and ESV, not all locations of PVL improve equally over time, which has implications for heart failure readmissions. This could be used to influence valve selection and to identify cases in which earlier intervention on PVL may be appropriate.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA