Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Circulation ; 149(15): 1172-1182, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38410954

RESUMEN

BACKGROUND: Recent guidelines redefined exercise pulmonary hypertension as a mean pulmonary artery pressure/cardiac output (mPAP/CO) slope >3 mm Hg·L-1·min-1. A peak systolic pulmonary artery pressure >60 mm Hg during exercise has been associated with an increased risk of cardiovascular death, heart failure rehospitalization, and aortic valve replacement in aortic valve stenosis. The prognostic value of the mPAP/CO slope in aortic valve stenosis remains unknown. METHODS: In this prospective cohort study, consecutive patients (n=143; age, 73±11 years) with an aortic valve area ≤1.5 cm2 underwent cardiopulmonary exercise testing with echocardiography. They were subsequently evaluated for the occurrence of cardiovascular events (ie, cardiovascular death, heart failure hospitalization, new-onset atrial fibrillation, and aortic valve replacement) during a follow-up period of 1 year. Findings were externally validated (validation cohort, n=141). RESULTS: One cardiovascular death, 32 aortic valve replacements, 9 new-onset atrial fibrillation episodes, and 4 heart failure hospitalizations occurred in the derivation cohort, whereas 5 cardiovascular deaths, 32 aortic valve replacements, 1 new-onset atrial fibrillation episode, and 10 heart failure hospitalizations were observed in the validation cohort. Peak aortic velocity (odds ratio [OR] per SD, 1.48; P=0.036), indexed left atrial volume (OR per SD, 2.15; P=0.001), E/e' at rest (OR per SD, 1.61; P=0.012), mPAP/CO slope (OR per SD, 2.01; P=0.002), and age-, sex-, and height-based predicted peak exercise oxygen uptake (OR per SD, 0.59; P=0.007) were independently associated with cardiovascular events at 1 year, whereas peak systolic pulmonary artery pressure was not (OR per SD, 1.28; P=0.219). Peak Vo2 (percent) and mPAP/CO slope provided incremental prognostic value in addition to indexed left atrial volume and aortic valve area (P<0.001). These results were confirmed in the validation cohort. CONCLUSIONS: In moderate and severe aortic valve stenosis, mPAP/CO slope and percent-predicted peak Vo2 were independent predictors of cardiovascular events, whereas peak systolic pulmonary artery pressure was not. In addition to aortic valve area and indexed left atrial volume, percent-predicted peak Vo2 and mPAP/CO slope cumulatively improved risk stratification.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Pronóstico , Ecocardiografía de Estrés/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Gasto Cardíaco , Insuficiencia Cardíaca/complicaciones , Oxígeno
2.
Radiology ; 312(2): e240229, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39136569

RESUMEN

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (r = 0.92; P < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; P = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm3 [95% LoA: -0.27 cm3, 0.19 cm3] and 0.02 cm3 [95% LoA: -0.14 cm3, 0.19 cm3], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almeida in this issue.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Angiografía por Tomografía Computarizada , Fibrosis , Humanos , Masculino , Estudios Prospectivos , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Persona de Mediana Edad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Fibrosis/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Anciano
3.
Curr Atheroscler Rep ; 26(7): 305-315, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38727963

RESUMEN

PURPOSE OF REVIEW: Despite recent advances, coronary artery disease remains one of the leading causes of mortality worldwide. Noninvasive imaging allows atherosclerotic phenotyping by measurement of plaque burden, morphology, activity and inflammation, which has the potential to refine patient risk stratification and guide personalized therapy. This review describes the current and emerging roles of advanced noninvasive cardiovascular imaging methods for the assessment of coronary artery disease. RECENT FINDINGS: Cardiac computed tomography enables comprehensive, noninvasive imaging of the coronary vasculature, and is used to assess luminal stenoses, coronary calcifications, and distinct adverse plaque characteristics, helping to identify patients prone to future events. Novel software tools, implementing artificial intelligence solutions, can automatically quantify and characterize atherosclerotic plaque from standard computed tomography datasets. These quantitative imaging biomarkers have been shown to improve patient risk stratification beyond clinical risk scores and current clinical interpretation of cardiac computed tomography. In addition, noninvasive molecular imaging in higher risk patients can be used to assess plaque activity and plaque thrombosis. Noninvasive imaging allows unique insight into the burden, morphology and activity of atherosclerotic coronary plaques. Such phenotyping of atherosclerosis can potentially improve individual patient risk prediction, and in the near future has the potential for clinical implementation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Fenotipo , Placa Aterosclerótica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/diagnóstico , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/patología , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Medición de Riesgo/métodos
4.
Artículo en Inglés | MEDLINE | ID: mdl-38860493

RESUMEN

AIMS: Transthoracic echocardiography is recommended in all patients with acute coronary syndrome but is time-consuming and lacks an evidence base. We aimed to assess the feasibility, diagnostic accuracy and time-efficiency of hand-held echocardiography in patients with acute coronary syndrome and describe the impact of echocardiography on clinical management in this setting. METHODS AND RESULTS: Patients with acute coronary syndrome underwent both hand-held and transthoracic echocardiography with agreement between key imaging parameters assessed using kappa statistics. The immediate clinical impact of hand-held echocardiography in this population was systematically evaluated.Overall, 262 patients (65±12 years, 71% male) participated. Agreement between hand-held and transthoracic echocardiography was good-to-excellent (kappa 0.60-1.00) with hand-held echocardiography having an overall negative predictive value of 95%. Hand-held echocardiography was performed rapidly (7.7±1.6 min) and completed a median of 5 [interquartile range 3-20] hours earlier than transthoracic echocardiography. Systematic hand-held echocardiography in all patients with acute coronary syndrome identified an important cardiac abnormality in 50% and the clinical management plan was changed by echocardiography in 42%. In 85% of cases, hand-held echocardiography was sufficient for patient decision-making and transthoracic echocardiography was no longer deemed necessary. CONCLUSIONS: In patients with acute coronary syndrome, hand-held echocardiography provides comparable results to transthoracic echocardiography, can be more rapidly applied and gives sufficient imaging information for decision-making in the vast majority of patients. Systematic echocardiography has clinical impact in half of patients, supporting the clinical utility of echocardiography in this population, and providing an evidence-base for current guidelines.

5.
medRxiv ; 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39132480

RESUMEN

Background: Computed tomography attenuation correction (CTAC) scans are routinely obtained during cardiac perfusion imaging, but currently only utilized for attenuation correction and visual calcium estimation. We aimed to develop a novel artificial intelligence (AI)-based approach to obtain volumetric measurements of chest body composition from CTAC scans and evaluate these measures for all-cause mortality (ACM) risk stratification. Methods: We applied AI-based segmentation and image-processing techniques on CTAC scans from a large international image-based registry (four sites), to define chest rib cage and multiple tissues. Volumetric measures of bone, skeletal muscle (SM), subcutaneous, intramuscular (IMAT), visceral (VAT), and epicardial (EAT) adipose tissues were quantified between automatically-identified T5 and T11 vertebrae. The independent prognostic value of volumetric attenuation, and indexed volumes were evaluated for predicting ACM, adjusting for established risk factors and 18 other body compositions measures via Cox regression models and Kaplan-Meier curves. Findings: End-to-end processing time was <2 minutes/scan with no user interaction. Of 9918 patients studied, 5451(55%) were male. During median 2.5 years follow-up, 610 (6.2%) patients died. High VAT, EAT and IMAT attenuation were associated with increased ACM risk (adjusted hazard ratio (HR) [95% confidence interval] for VAT: 2.39 [1.92, 2.96], p<0.0001; EAT: 1.55 [1.26, 1.90], p<0.0001; IMAT: 1.30 [1.06, 1.60], p=0.0124). Patients with high bone attenuation were at lower risk of death as compared to subjects with lower bone attenuation (adjusted HR 0.77 [0.62, 0.95], p=0.0159). Likewise, high SM volume index was associated with a lower risk of death (adjusted HR 0.56 [0.44, 0.71], p<0.0001). Interpretations: CTAC scans obtained routinely during cardiac perfusion imaging contain important volumetric body composition biomarkers which can be automatically measured and offer important additional prognostic value. Research in context: Evidence before this study: Fully automated volumetric body composition analysis of chest computed tomography attenuation correction (CTAC) can be obtained in patients undergoing myocardial perfusion imaging. This new information has potential to significantly improve risk stratification and patient management. However, the CTAC scans have not been utilized for body composition analysis to date. We searched PubMed and Google Scholar for existing body composition related literature on June 5, 2024, using the search term ("mortality") AND ("risk stratification" OR "survival analysis" OR "prognostic prediction" OR "prognosis") AND ("body composition quantification" OR "body composition analysis" OR "body composition segmentation"). We identified 34 articles either exploring body composition segmentation or evaluating clinical value of body composition quantification. However, to date, all the prognostic evaluation is performed for quantification of three or fewer types of body composition tissues. Within the prognostic studies, only one used chest CT scans but utilized only a few specified slices selected from the scans, and not a standardized volumetric analysis. None of these previous efforts utilized CTAC scans, and none included epicardial adipose tissue in comprehensive body composition analysis.Added value of this study: In this international multi-center study, we demonstrate a novel artificial intelligence-based annotation-free approach for segmenting six key body composition tissues (bone, skeletal muscle, subcutaneous adipose tissue, intramuscular adipose tissue, epicardial adipose tissue, and visceral adipose tissue) from low-dose ungated CTAC scans, by exploiting existing CT segmentation models and image processing techniques. We evaluate the prognostic value of metrics derived from volumetric quantification of CTAC scans obtained during cardiac imaging, for all-cause mortality prediction in a large cohort of patients. We reveal strong and independent associations between several volumetric body composition metrics and all-cause mortality after adjusting for existing clinical factors, and available cardiac perfusion and atherosclerosis biomarkers.Implications of all the available evidence: The comprehensive body composition analysis can be routinely performed, at the point of care, for all cardiac perfusion scans utilizing CTAC. Automatically-obtained volumetric body composition quantification metrics provide added value over existing risk factors, using already-obtained scans to significantly improve the risk stratification of patients and clinical decision-making.

6.
Artículo en Inglés | MEDLINE | ID: mdl-39115499

RESUMEN

BACKGROUND: Aortic stenosis (AS) is characterized by calcification and fibrosis. The ability to quantify these processes simultaneously has been limited with previous imaging methods. OBJECTIVES: The purpose of this study was to evaluate the aortic valve fibrocalcific volume by computed tomography (CT) angiography in patients with AS, in particular, to assess its reproducibility, association with histology and disease severity, and ability to predict/track progression. METHODS: In 136 patients with AS, fibrocalcific volume was calculated on CT angiograms at baseline and after 1 year. CT attenuation distributions were analyzed using Gaussian-mixture-modeling to derive thresholds for tissue types enabling the quantification of calcific, noncalcific, and fibrocalcific volumes. Scan-rescan reproducibility was assessed and validation provided against histology and in an external cohort. RESULTS: Fibrocalcific volume measurements took 5.8 ± 1.0 min/scan, demonstrating good correlation with ex vivo valve weight (r = 0.51; P < 0.001) and excellent scan-rescan reproducibility (mean difference -1%, limits of agreement -4.5% to 2.8%). Baseline fibrocalcific volumes correlated with mean gradient on echocardiography in both male and female participants (rho = 0.64 and 0.69, respectively; both P < 0.001) and in the external validation cohort (n = 66, rho = 0.58; P < 0.001). The relationship was driven principally by calcific volume in men and fibrotic volume in women. After 1 year, fibrocalcific volume increased by 17% and correlated with progression in mean gradient (rho = 0.32; P = 0.003). Baseline fibrocalcific volume was the strongest predictor of subsequent mean gradient progression, with a particularly strong association in female patients (rho = 0.75; P < 0.001). CONCLUSIONS: The aortic valve fibrocalcific volume provides an anatomic assessment of AS severity that can track disease progression precisely. It correlates with disease severity and hemodynamic progression in both male and female patients.

7.
Semin Nucl Med ; 53(2): 241-257, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36116988

RESUMEN

Aortic valve stenosis is the most common valvular disease in Western countries, while atherosclerotic cardiovascular disease is the foremost cause of death and disability worldwide. Valve degeneration and atherosclerosis are mediated by inflammation and calcification and inevitably progress over time. Computed tomography can visualise the later stages of macroscopic calcification but fails to assess the early stages of microcalcification and cannot differentiate active from burnt out disease states. Molecular imaging has the ability to provide complementary information related to disease activity, which may allow us to detect disease early, to predict disease progression and to monitor preventive or therapeutic strategies for in both aortic stenosis and atherosclerosis. PET/CT is a non-invasive imaging technique that enables visualization of ongoing molecular processes within small structures, such as the coronary arteries or heart valves. 18F-sodium fluoride (18F-NaF) binds hydroxyapatite deposits in the extracellular matrix, with preferential binding to newly developing deposits of microcalcification, which provides an assessment of calcification activity. In recent years, 18F-NaF has attracted the attention of many research groups and has been evaluated in several pathological cardiovascular processes. Histologic validation of the 18F-NaF PET signal in valvular disease and atherosclerosis has been reported in multiple independent studies. The selective high-affinity binding of 18F-NaF to microscopic calcified deposits (beyond the resolution of µCT) has been demonstrated ex vivo, as well as its ability to distinguish between areas of macro- and active microcalcification. In addition, prospective clinical studies have shown that baseline 18F-NaF uptake in patients with aortic stenosis and mitral annular calcification is correlated with subsequent calcium deposition and valvular dysfunction after a follow-up period of 2 years. In patients with surgical bioprosthetic aortic valves but without morphological criteria for prosthetic degeneration, increased 18F-NaF uptake at baseline was associated with subsequent bioprosthetic degeneration over time. Similar data were obtained in a cohort of patients with transcatheter aortic valve implantation. Furthermore, several studies have confirmed the association of coronary 18F-NaF uptake with adverse atherosclerotic plaque features, active disease and future disease progression. 18F-NaF uptake is also associated with future fatal or nonfatal myocardial infarction in patients with established coronary artery disease. The link between 18F-NaF uptake and active atherosclerotic disease has not only been demonstrated in the coronary arteries, but also in peripheral arterial disease, abdominal aortic aneurysms and carotid atherosclerosis. It can be assumed that 18F-NaF PET/CT will strengthen the diagnostic toolbox of practitioners in the coming years. Indeed, there is a strong medical need to diagnose degenerative valvular disease and to detect active atherosclerotic disease states. Finally, the use of 18F-NaF as a biomarker to monitor the efficacy of drug therapies in preventing these pathological processes is attractive. In this review, we consider the role of 18F-NaF PET/CT imaging in cardiac valvular diseases and atherosclerosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Aterosclerosis , Calcinosis , Enfermedades de las Válvulas Cardíacas , Placa Aterosclerótica , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluoruro de Sodio/metabolismo , Estudios Prospectivos , Radiofármacos/metabolismo , Placa Aterosclerótica/metabolismo , Calcinosis/metabolismo , Progresión de la Enfermedad , Radioisótopos de Flúor
8.
Diagnostics (Basel) ; 13(15)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37568924

RESUMEN

Moderate to severe frailty is a predictor of a poor outcome after transcatheter aortic valve replacement (TAVR), but little is known about the prognostic importance of different geriatric frailty markers in an overall fit or pre-frail geriatric population undergoing TAVR. This retrospective study aimed to examine the incremental value of adding patient frailty markers to conventional surgical risk score to predict all-cause mortality in relatively fit elderly patients undergoing TAVR. Overall patient frailty was assessed using the comprehensive geriatric assessment frailty index (CGA-FI). Multivariable Cox regression models were used to evaluate relationships of different geriatric frailty markers with all-cause mortality and single and combined frailty models were compared to a baseline model that included EuroSCORE II factors. One hundred relatively fit geriatric patients (84 ± 4 years old, mean CGA-FI 0.14 ± 0.05) were included, and 28% died during a median follow-up of 24 months. After adjustment, risk of depression (geriatric depression scale 15 (GDS-15)) and malnutrition remained significantly associated with all-cause mortality (HR 4.381, 95% CI 1.787-10.743; p = 0.001 and HR 3.076, 95% CI 1.151-8.217; p = 0.025, respectively). A combined frailty marker model including both GDS-15 and malnutrition on top of EuroSCORE II improved the discriminative ability to predict all-cause mortality (change in c-index: + 0.044). Screening for those frailty markers on top of the traditionally used EuroSCORE II may improve risk stratification and prognosis in relatively fit geriatric patients undergoing TAVR.

9.
Int J Cardiovasc Imaging ; 39(3): 585-593, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36471103

RESUMEN

PURPOSE: The aim of the present study was to evaluate the role of ejection fraction (EF), left ventricular (LV) global longitudinal strain (LVGLS) and global constructive work (GCW) as prognostic variables in patients with cardiac amyloidosis (CA). METHODS: CA patients were retrospectively identified between 2015 and 2021 at a tertiary care hospital. Comprehensive clinical, biochemical, and imaging evaluation including two-dimensional (2D) echocardiography with myocardial work (MW) analysis was performed. A clinical combined endpoint was defined as all-cause mortality and heart failure readmission. RESULTS: 70 patients were followed for 16 (7-37) months and 37 (52.9%) reached the combined endpoint. Patient with versus without clinical events had a significantly lower LVEF (40.71% vs. 48.01%, p = 0.039), LVGLS (-9.26 vs. -11.32, p = 0.034) and GCW (1034.47mmHg% vs. 1424.86mmHg%, p = 0.011). Multivariable analysis showed that LVEF ( odds ratio (OR): 0.904; 95% confidence interval (CI): 0.839-0.973, p = 0.007), LVGLS ( OR: 0.620; 95% CI: 0.415-0.926, p = 0.020) and GCW ( OR: 0.995; 95% CI: 0.990-0.999, p = 0.016) were significant predictors of outcome, but the model including GCW had the best discriminative ability to predict the combined endpoint (C-index = 0.888). A GCW less than 1443mmHg% was able to predict the clinical endpoint with a sensitivity of 94% and a specificity of 64% (Area under the curve (AUC): 0.771 (95% CI: 0.581-0.961; p = 0.005)). CONCLUSION: In CA patients, GCW may be of additional prognostic value to LVEF and GLS in predicting heart failure hospitalization and all-cause mortality.


Asunto(s)
Amiloidosis , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Pronóstico , Estudios Retrospectivos , Volumen Sistólico , Valor Predictivo de las Pruebas , Función Ventricular Izquierda
11.
Diagnostics (Basel) ; 12(1)2021 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-35054224

RESUMEN

Long coronavirus disease 2019 (COVID-19) was described in patients recovering from COVID-19, with dyspnea being a frequent symptom. Data regarding the potential mechanisms of long COVID remain scarce. We investigated the presence of subclinical cardiac dysfunction, assessed by transthoracic echocardiography (TTE), in recovered COVID-19 patients with or without dyspnea, after exclusion of previous cardiopulmonary diseases. A total of 310 consecutive COVID-19 patients were prospectively included. Of those, 66 patients (mean age 51.3 ± 11.1 years, almost 60% males) without known cardiopulmonary diseases underwent one-year follow-up consisting of clinical evaluation, spirometry, chest computed tomography, and TTE. From there, 23 (34.8%) patients reported dyspnea. Left ventricle (LV) ejection fraction was not significantly different between patients with or without dyspnea (55.7 ± 4.6 versus (vs.) 57.6 ± 4.5, p = 0.131). Patients with dyspnea presented lower LV global longitudinal strain, global constructive work (GCW), and global work index (GWI) compared to asymptomatic patients (-19.9 ± 2.1 vs. -21.3 ± 2.3 p = 0.039; 2183.7 ± 487.9 vs. 2483.1 ± 422.4, p = 0.024; 1960.0 ± 396.2 vs. 2221.1 ± 407.9, p = 0.030). GCW and GWI were inversely and independently associated with dyspnea (p = 0.035, OR 0.998, 95% CI 0.997-1.000; p = 0.040, OR 0.998, 95% CI 0.997-1.000). Persistent dyspnea one-year after COVID-19 was present in more than a third of the recovered patients. GCW and GWI were the only echocardiographic parameters independently associated with symptoms, suggesting a decrease in myocardial performance and subclinical cardiac dysfunction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA