Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 314
Filtrar
Más filtros

Intervalo de año de publicación
1.
Am Heart J ; 275: 128-137, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas/efectos adversos , Ecocardiografía/métodos , Estenosis de la Válvula Aórtica/cirugía , Anciano , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ajuste de Prótesis
2.
Catheter Cardiovasc Interv ; 103(4): 532-538, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38415895

RESUMEN

BACKGROUND: Studies evaluating the safety and efficacy of drug coating balloons (DCB) for the treatment of lesions in large coronary vessel are limited. AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries. METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality. RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003). CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Sirolimus/efectos adversos , Resultado del Tratamiento , Angiografía Coronaria , Materiales Biocompatibles Revestidos
3.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36331961

RESUMEN

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Incidencia , Factores de Riesgo , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , Ecocardiografía
4.
Rev Cardiovasc Med ; 24(8): 221, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39076703

RESUMEN

Background: The DynamX Novolimus-Eluting Coronary Bioadaptor System ( DynamX ® Bioadaptor) has uncaging elements that disengage after the resorption of the polymer coating, aiming to restore vessel function in the treated segment and to avoid long-term adverse outcomes associated with the permanent caging of the coronary artery seen with conventional stenting. Methods: This prospective, multicenter, single-arm first-in-human study enrolled 50 patients in Belgium and Italy who were treated with the DynamX Bioadaptor. Eligible patients had de novo lesions in coronary arteries measuring between 2.5 and 3.5 mm in diameter and ≤ 24 mm in length. Clinical follow-up was performed up to 36 months. This analysis includes the intention-to-treat population and is based on data available. The preclinical studies include optical coherence tomography (OCT) analyses of 5 DynamX Bioadaptors implanted in 3 mini Yucatan pigs (at 3, 12 and 24 months), and assessment of smooth muscle cell gene expression profile in 8 pigs of which each was implanted with the DynamX Bioadaptor and the Xience drug-eluting stent. To assess the gene expression profile by quantitative real-time polymerase chain reaction, animals were sacrificed at 3, 6, 9 and 12 months. Results: Target lesion failure at 36 months was 8.7% (4/46), consisting of one clinically-driven target lesion revascularization and 3 cardiac deaths (all site-reported to be unrelated to the device or procedure). There were no additional target vessel revascularization and no definite or probable scaffold thrombosis. Preclinical data confirmed late lumen enlargement (from 7.02 ± 1.31 mm 2 at baseline to 8.46 ± 1.31 mm 2 at 24 months) and identified an increased expression of contractile genes around 9 months compared to a conventional drug-eluting stent. Conclusions: The DynamX Bioadaptor demonstrated very good 36-month clinical outcomes, highlighted by the absence of target-vessel myocardial infarction and definite or probable device thrombosis, and only one target lesion revascularization up to 36 months. These data are supported by preclinical studies that showed late lumen enlargement by OCT and an increased expression of contractile genes around 9 months compared to conventional drug-eluting stents, indicating faster vessel healing. Larger clinical studies are necessary to compare outcomes against contemporary drug-eluting stents. Clinical Trial Registration: https://clinicaltrials.gov/: NCT03429894.

5.
Catheter Cardiovasc Interv ; 102(6): 1057-1060, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37937675

RESUMEN

The Coronary Sinus Reducer® (CSR) is an emerging therapy for refractory angina recommended once no further pharmacologic or coronary revascularization options are available. We present the case of a 72-year-old man who underwent CSR implantation. Complex coronary sinus anatomy necessitated an innovative "grandmother, mother, and child" catheter approach.


Asunto(s)
Seno Coronario , Anciano , Humanos , Masculino , Angina de Pecho/terapia , Seno Coronario/diagnóstico por imagen , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37694603

RESUMEN

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
7.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36841945

RESUMEN

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Humanos , Angiografía Coronaria , Calcio , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Stents
8.
Catheter Cardiovasc Interv ; 101(6): 1144-1153, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36924020

RESUMEN

AIMS: To compare outcomes of patients who underwent left atrial appendage occlusion (LAAO) for nonvalvular atrial fibrillation (NVAF) and contraindication to anticoagulants due to history of either gastrointestinal (GI) or intracranial (IC) bleeding. METHODS: Patients with NVAF that underwent LAAO for GI or IC bleeding from seven centers were included in this observational study. Baseline characteristics, procedural features, and follow-up data were collected, and compared between the two groups. The primary outcomes were incidence of ischemic and hemorrhagic events at 12-month. RESULTS: Six hundred twenty-eight patients were included, 57% with previous GI-bleeding, and 43% with previous IC-bleeding. Median CHA 2 DS 2-VASc score was 4 (interquartile range [IQRs]: 3-5) for both GI-bleeding and IC-bleeding patients, while GI-bleeding patients had a higher HAS-BLED score (4 [IQRs: 3-4] vs. 3 [IQRs]: 2-3]; p = 0.001). At 12-month follow-up, relative risk reduction for stroke was similar between the two groups. The GI-bleeding group had more hemorrhagic events compared to IC-bleeding group (any bleeding 8.4% vs. 3.2%; p = 0.012; major bleeding BARC 3-5: 4.3% vs. 1.8; p = 0.010). At multivariate analysis history of GI bleeding was an independent predictor of hemorrhagic events (adjusted HR: 2.39, 95% confidence interval: 1.02-5.63; p = 0.047). CONCLUSIONS: Outcomes after LAAO may be affected by the different indications for the procedure. In our study, GI-bleeding and IC-bleeding as indication to LAAO differ in their baseline characteristics. LAAO confirms its efficacy in ischemic risk reduction in both groups, while GI bleeding seems to be an independent predictor of bleeding recurrence at 12 months behind the antithrombotic regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/prevención & control , Hemorragias Intracraneales/etiología , Sistema de Registros , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Lógica
9.
Eur Radiol ; 33(11): 7756-7768, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37166497

RESUMEN

OBJECTIVE: To assess the value of opportunistic biomarkers derived from chest CT performed at hospital admission of COVID-19 patients for the phenotypization of high-risk patients. METHODS: In this multicentre retrospective study, 1845 consecutive COVID-19 patients with chest CT performed within 72 h from hospital admission were analysed. Clinical and outcome data were collected by each center 30 and 80 days after hospital admission. Patients with unknown outcomes were excluded. Chest CT was analysed in a single core lab and behind pneumonia CT scores were extracted opportunistic data about atherosclerotic profile (calcium score according to Agatston method), liver steatosis (≤ 40 HU), myosteatosis (paraspinal muscle F < 31.3 HU, M < 37.5 HU), and osteoporosis (D12 bone attenuation < 134 HU). Differences according to treatment and outcome were assessed with ANOVA. Prediction models were obtained using multivariate binary logistic regression and their AUCs were compared with the DeLong test. RESULTS: The final cohort included 1669 patients (age 67.5 [58.5-77.4] yo) mainly men 1105/1669, 66.2%) and with reduced oxygen saturation (92% [88-95%]). Pneumonia severity, high Agatston score, myosteatosis, liver steatosis, and osteoporosis derived from CT were more prevalent in patients with more aggressive treatment, access to ICU, and in-hospital death (always p < 0.05). A multivariable model including clinical and CT variables improved the capability to predict non-critical pneumonia compared to a model including only clinical variables (AUC 0.801 vs 0.789; p = 0.0198) to predict patient death (AUC 0.815 vs 0.800; p = 0.001). CONCLUSION: Opportunistic biomarkers derived from chest CT can improve the characterization of COVID-19 high-risk patients. CLINICAL RELEVANCE STATEMENT: In COVID-19 patients, opportunistic biomarkers of cardiometabolic risk extracted from chest CT improve patient risk stratification. KEY POINTS: • In COVID-19 patients, several information about patient comorbidities can be quantitatively extracted from chest CT, resulting associated with the severity of oxygen treatment, access to ICU, and death. • A prediction model based on multiparametric opportunistic biomarkers derived from chest CT resulted superior to a model including only clinical variables in a large cohort of 1669 patients suffering from SARS- CoV2 infection. • Opportunistic biomarkers of cardiometabolic comorbidities derived from chest CT may improve COVID-19 patients' risk stratification also in absence of detailed clinical data and laboratory tests identifying subclinical and previously unknown conditions.


Asunto(s)
COVID-19 , Enfermedades Cardiovasculares , Hígado Graso , Osteoporosis , Masculino , Humanos , Anciano , Femenino , Estudios Retrospectivos , SARS-CoV-2 , Mortalidad Hospitalaria , Tomografía Computarizada por Rayos X/métodos , Biomarcadores
10.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
11.
Catheter Cardiovasc Interv ; 99(3): 664-673, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34582631

RESUMEN

OBJECTIVES: to test the safety and efficacy of intravascular imaging and specifically optical coherence tomography (OCT) as a diagnostic tool for left main angioplasty and analyze the mid-term outcome accordingly. BACKGROUND: Clinical data and international guidelines recommend the use of intravascular imaging ultrasound (IVUS) to guide left main (LM) angioplasty. Despite early experience using OCT in this setting is encouraging, the evidence supporting its use is still limited. METHODS: ROCK II is a multicenter, investigator-driven, retrospective European study to compare the performance of IVUS and OCT versus angiography in patients undergoing distal-LM stenting. The primary study endpoint was target-lesion failure (TLF) including cardiac death, target-vessel myocardial infarction and target-lesion revascularization. We designed this study hypothesizing the superiority of intravascular imaging over angiographic guidance alone, and the non-inferiority of OCT versus IVUS. RESULTS: A total of 730 patients, 377 with intravascular-imaging guidance (162 OCT, 215 IVUS) and 353 with angiographic guidance, were analyzed. The one-year rate of TLF was 21.2% with angiography and 12.7% with intravascular-imaging (p = 0.039), with no difference between OCT and IVUS (p = 0.26). Intravascular-imaging was predictor of freedom from TLF (HR 0.46; 95% CI 0.23-0.93: p = 0.03). Propensity-score matching identified three groups of 100 patients each with no significant differences in baseline characteristics. The one-year rate of TLF was 16% in the angiographic, 7% in the OCT and 6% in the IVUS group, respectively (p = 0.03 for IVUS or OCT vs. angiography). No between-group significant differences in the rate of individual components of TLF were found. CONCLUSIONS: Intravascular imaging was superior to angiography for distal LM stenting, with no difference between OCT and IVUS.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
12.
Catheter Cardiovasc Interv ; 99(4): 970-978, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35170844

RESUMEN

AIMS: The revascularization strategy to pursue in older myocardial infarction (MI) patients with multivessel disease (MVD) is currently unknown. For this reason, while waiting for the results of dedicated trials, we sought to compare a complete versus a culprit-only strategy in older MI patients by merging data from four registries. METHODS AND RESULTS: The inclusion criteria for the target population of the present study were (i) age ≥ 75 years; (ii) MI (STE or NSTE); (iii) MVD; (iv) successful treatment of culprit lesion. Propensity scores (PS) were derived using logistic regression (backward stepwise selection, p < 0.2). The primary outcome was all-cause mortality. Secondary outcomes were cardiovascular (CV) death, MI, and major bleeding. Multivariable adjustment included the PS and inverse probability of treatment weighting (IPTW). The Kaplan-Meier plots were weighted for IPT. Among 2087 patients included, 1362 (65%) received culprit-only treatment whereas 725 (35%) complete revascularization. The mean age was 81.5 years, while the mean follow-up was 419 ± 284 days. Seventy-four patients (10%) died in the complete group and 223 in the culprit-only one (16%). The adjusted cumulative 1-year mortality was 9.7% in the complete and 12.9% in the culprit-only group (adjusted HR: 0.67, 95% CI: 0.50-0.89). Complete revascularization was associated with lower incidence of CV death (adjusted HR: 0.68, 95% CI: 0.48-0.95) and MI (adjusted HR 0.67, 95% CI: 0.48-0.95). CONCLUSIONS: Culprit-only is the default strategy in older MI patients with MVD. In our analysis, complete revascularization was associated with lower all-cause and CV mortality and with a lower MI rate.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Infarto del Miocardio/terapia , Infarto del Miocardio con Elevación del ST/terapia , Resultado del Tratamiento
13.
J Card Surg ; 37(12): 5063-5072, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36413686

RESUMEN

BACKGROUND: The effect of metabolic syndrome (MetS), defined as insulin resistance along with two or more of: obesity, atherogenic dyslipidaemia and elevated blood pressure, on postoperative complications after isolated heart valve intervention remains controversial. We hypothesized that MetS may negatively influence the postoperative course in these patients. METHODS: Patients from 10 cardiac units who underwent isolated valve intervention (mitral ± $\pm $ tricuspid repair/replacement (mitral valve surgery [MVS]) or surgical aortic valve replacement (SAVR), or transcatheter aortic valve replacement (TAVR) were included. MetS was defined according to the World Health Organization criteria. Primary outcome was in-hospital mortality and overall postoperative length of stay (LOS). Relevant postoperative complications were also recorded. RESULTS: From 2010 to 2019, 17,283 patients underwent valve intervention. The MVS, SVAR, and TAVR accounted for the 39.4%, 48.2%, and 12.3% respectively of the whole. MetS compared to no-MetS was associated to higher mortality in the MVS group (6.5% vs. 2%, p < .001), but not in the SAVR and TAVR group. In both surgical cohorts, MetS was associated with increased complications including red blood cells transfusion, renal failure, mechanical ventilation time, intensive care and overall postoperative LOS (11 (9) vs. 10 (6), p < .001 and 10 (6) versus 10 (5) days, p = .002, MVS and [SAVR]). No differences were found in the TAVR cohort, with similar mortality and complications. CONCLUSION: MetS was associated to more postoperative complications, with higher mortality in the MVS group. In the TAVR cohort, postoperative complications and mortality rate did not differ between patients with and without MetS, however LOS was longer in the MetS group.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Síndrome Metabólico , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Síndrome Metabólico/complicaciones , Síndrome Metabólico/cirugía , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Complicaciones Posoperatorias/etiología
14.
Radiol Med ; 127(9): 960-972, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36038790

RESUMEN

PURPOSE: To develop and validate an effective and user-friendly AI platform based on a few unbiased clinical variables integrated with advanced CT automatic analysis for COVID-19 patients' risk stratification. MATERIAL AND METHODS: In total, 1575 consecutive COVID-19 adults admitted to 16 hospitals during wave 1 (February 16-April 29, 2020), submitted to chest CT within 72 h from admission, were retrospectively enrolled. In total, 107 variables were initially collected; 64 extracted from CT. The outcome was survival. A rigorous AI model selection framework was adopted for models selection and automatic CT data extraction. Model performances were compared in terms of AUC. A web-mobile interface was developed using Microsoft PowerApps environment. The platform was externally validated on 213 COVID-19 adults prospectively enrolled during wave 2 (October 14-December 31, 2020). RESULTS: The final cohort included 1125 patients (292 non-survivors, 26%) and 24 variables. Logistic showed the best performance on the complete set of variables (AUC = 0.839 ± 0.009) as in models including a limited set of 13 and 5 variables (AUC = 0.840 ± 0.0093 and AUC = 0.834 ± 0.007). For non-inferior performance, the 5 variables model (age, sex, saturation, well-aerated lung parenchyma and cardiothoracic vascular calcium) was selected as the final model and the extraction of CT-derived parameters was fully automatized. The fully automatic model showed AUC = 0.842 (95% CI: 0.816-0.867) on wave 1 and was used to build a 0-100 scale risk score (AI-SCoRE). The predictive performance was confirmed on wave 2 (AUC 0.808; 95% CI: 0.7402-0.8766). CONCLUSIONS: AI-SCoRE is an effective and reliable platform for automatic risk stratification of COVID-19 patients based on a few unbiased clinical data and CT automatic analysis.


Asunto(s)
COVID-19 , Adulto , Inteligencia Artificial , Calcio , Humanos , Estudios Retrospectivos , SARS-CoV-2
15.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-33733675

RESUMEN

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Incidencia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 97(5): 950-954, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32865314

RESUMEN

Aortitis is an uncommon systemic inflammatory disease affecting the aorta and its main branches. Severe aortic regurgitation (AR) represents a fearsome complication of aortitis and is associated with an increased mortality rate. Surgical aortic valve replacement represents the only treatment choice for these patients. However, it is associated with a higher risk of medium to long-term complications such as prosthetic valve detachment. This is the first reported case where severe AR secondary to aortitis was managed with transcatheter aortic valve implantation (TAVI). TAVI was safe and effective in this clinical setting and may be considered a viable alternative to high-risk surgery in these complex patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Aortitis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Aortitis/diagnóstico por imagen , Aortitis/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 97(3): 443-450, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-31967390

RESUMEN

Contrast-induced acute kidney injury (CI-AKI) represents a common but serious complication of percutaneous coronary interventions (PCI)-and in general of all those examinations requiring iodinated contrast injection-which affects not only renal function but also long-term prognosis. While several prophylactic approaches were designed in order to prevent CI-AKI, most failed to demonstrate clear benefits in randomized trials, and their implementation is therefore discouraged in clinical practice. The most notorious examples include pre-procedural bicarbonate or N-acetylcysteine, and preprocedural withdrawal of ACE inhibitors/Angiotensin receptor blockers. Those strategies that were instead demonstrated effective include the appropriate use of preprocedural hydration, reduction in contrast volume utilization, adoption of techniques for zero- or ultra-low-contrast procedures, and pharmacological treatments with statins. In this brief review, we summarize the main preventive strategies into brief and pragmatic recommendations designed to improve everyday clinical practice.


Asunto(s)
Lesión Renal Aguda , Intervención Coronaria Percutánea , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/prevención & control , Medios de Contraste/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 98(3): E365-E369, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33851771

RESUMEN

AIM: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device. METHODS: Prior to device implantation and at 4-month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI). RESULTS: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (<5.8 mm) presented a significantly higher percentage increase in MPRI (63 ± 51 vs 9 ± 30%, P = .03) and a higher reduction in left ventricle end-diastolic volumes. CONCLUSIONS: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non-responsiveness.


Asunto(s)
Seno Coronario , Angina de Pecho , Seno Coronario/diagnóstico por imagen , Tolerancia al Ejercicio , Humanos , Isquemia , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 97(7): E900-E910, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201611

RESUMEN

OBJECTIVES AND BACKGROUND: Iatrogenic aorto-coronary dissection (ICD) is one of the most feared complications of interventional cardiology. Although rare, it is characterized by anterograde coronary ischemia and a concomitant aortic dissection, with potentially fatal consequences. METHODS: We present an example case of IACD and an accurate case-series review of the literature including 125 published cases. RESULTS: There were no significant predisposing factors and the IACD occurred equally in elective and urgent procedures. A significant number of IACDs were associated with CTO procedures. The factors associated with a worse outcome were hemodynamic instability, the presence of anterograde ischemia, and the extent of dissection according to the Dunning classification. Bail-out stenting was the most used strategy and its failure was associated with mortality. CONCLUSION: The main features of IACD are anterograde ischemia, retrograde dissection, and hemodynamic instability, each of them should be addressed with no time delay, possibly with bailout stenting, the most employed exit-strategy. According to our proposed algorithm, a shock team approach is required to coordinate the interdisciplinary skills and enabled patients to receive the best treatment.


Asunto(s)
Disección Aórtica , Vasos Coronarios , Humanos , Aorta , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/cirugía , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Disección , Enfermedad Iatrogénica , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 97(4): 581-588, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32790145

RESUMEN

BACKGROUND: The optimal antithrombotic regimen in patients with a concomitant indication for oral anticoagulation (OAT) presenting with acute coronary syndrome (ACS) or undergoing percutaneous coronary intervention (PCI) remains unclear. OBJECTIVES: To perform a network meta-analysis of all randomized controlled trials (RCTs) evaluating different antithrombotic regimens among patients with ACS or undergoing PCI requiring OAT. METHODS: Network meta-analysis was performed in a frequentist framework. Antithrombotic regimens were categorized by OAC type (vitamin K antagonist-based [VKA]; non-VKA OAT [NOAC]) and antiplatelet agents (P2Y inhibitor only: dual therapy [DAT]; P2Y plus aspirin: triple therapy [TAT]). Safety outcomes were Thrombolysis in Myocardial Infarction (TIMI) major bleeding and intracranial hemorrhage (ICH). Efficacy outcomes were cardiovascular death, myocardial infarction, stroke and stent-thrombosis (ST). RESULTS: Five RCTs were included, encompassing 10,797 patients (atrial fibrillation 69-100%, ACS 28-62%, PCI 77-100%). Both VKA and NOAC-based DAT regimens reduced the occurrence of TIMI major bleeding compared to VKA TAT (VKA DAT: RR 0.62, 95% CI 0.39-0.98; NOAC DAT: RR 0.52, 95% CI 0.39-0.70). Nevertheless, only NOAC DAT significantly reduced the occurrence of ICH compared to VKA TAT (RR 0.33, 95% CI 0.17-0.64). Ischemic outcomes were similar among the four treatment regimens. However, numerical, potentially clinically important, higher ST occurrence was observed for NOAC DAT as compared to both VKA TAT (1.50, 95% confidence interval [CI] 0.96-2.33) and NOAC TAT (1.86, 95% CI 0.93-3.73). CONCLUSION: DAT regimens present the highest safety profile among antithrombotic strategies, with a NOAC-specific impact on ICH reduction. NOAC DAT might entail clinically important higher ST occurrence, warranting a case-by-case comprehensive evaluation that integrates patient- and procedure-related residual ischemic risk with the patient-specific bleeding risk.


Asunto(s)
Fibrilación Atrial , Intervención Coronaria Percutánea , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrinolíticos/efectos adversos , Humanos , Metaanálisis en Red , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA