Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Liver Transpl ; 30(5): 484-492, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38015444

RESUMEN

Due to the success of minimally invasive liver surgery, laparoscopic and robotic minimally invasive donor hepatectomies (MIDH) are increasingly performed worldwide. We conducted a retrospective, multicentre, propensity score-matched analysis on right lobe MIDH by comparing the robotic, laparoscopic, and open approaches to assess the feasibility, safety, and early outcomes of MIDHs. From January 2016 until December 2020, 1194 donors underwent a right donor hepatectomy performed with a robotic (n = 92), laparoscopic (n = 306), and open approach (n = 796) at 6 high-volume centers. Donor and recipients were matched for different variables using propensity score matching (1:1:2). Donor outcomes were recorded, and postoperative pain was measured through a visual analog scale. Recipients' outcomes were also analyzed. Ninety-two donors undergoing robotic surgery were matched and compared to 92 and 184 donors undergoing laparoscopic and open surgery, respectively. Conversions to open surgery occurred during 1 (1.1%) robotic and 2 (2.2%) laparoscopic procedures. Robotic procedures had a longer operative time (493 ± 96 min) compared to laparoscopic and open procedures (347 ± 120 and 358 ± 95 min; p < 0.001) but were associated with reduced donor blood losses ( p < 0.001). No differences were observed in overall and major complications (≥ IIIa). Robotic hepatectomy donors had significantly less pain compared to the 2 other groups ( p < 0.001). Fifty recipients of robotic-procured grafts were matched to 50 and 100 recipients of laparoscopic and open surgery procured grafts, respectively. No differences were observed in terms of postoperative complications, and recipients' survival was similar ( p =0.455). In very few high-volume centers, robotic right lobe procurement has shown to be a safe procedure. Despite an increased operative and the first warm ischemia times, this approach is associated with reduced intraoperative blood losses and pain compared to the laparoscopic and open approaches. Further data are needed to confirm it as a valuable option for the laparoscopic approach in MIDH.


Asunto(s)
Laparoscopía , Trasplante de Hígado , Procedimientos Quirúrgicos Robotizados , Humanos , Hepatectomía/efectos adversos , Hepatectomía/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Estudios Retrospectivos , Trasplante de Hígado/efectos adversos , Trasplante de Hígado/métodos , Donadores Vivos , Hígado , Laparoscopía/efectos adversos , Laparoscopía/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/etiología , Tiempo de Internación
2.
Ann Surg Oncol ; 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879668

RESUMEN

INTRODUCTION: Despite the increasing widespread adoption and experience in minimally invasive liver resections (MILR), open conversion occurs not uncommonly even with minor resections and as been reported to be associated with inferior outcomes. We aimed to identify risk factors for and outcomes of open conversion in patients undergoing minor hepatectomies. We also studied the impact of approach (laparoscopic or robotic) on outcomes. METHODS: This is a post-hoc analysis of 20,019 patients who underwent RLR and LLR across 50 international centers between 2004-2020. Risk factors for and perioperative outcomes of open conversion were analysed. Multivariate and propensity score-matched analysis were performed to control for confounding factors. RESULTS: Finally, 10,541 patients undergoing either laparoscopic (LLR; 89.1%) or robotic (RLR; 10.9%) minor liver resections (wedge resections, segmentectomies) were included. Multivariate analysis identified LLR, earlier period of MILR, malignant pathology, cirrhosis, portal hypertension, previous abdominal surgery, larger tumor size, and posterosuperior location as significant independent predictors of open conversion. The most common reason for conversion was technical issues (44.7%), followed by bleeding (27.2%), and oncological reasons (22.3%). After propensity score matching (PSM) of baseline characteristics, patients requiring open conversion had poorer outcomes compared with successful MILR cases as evidenced by longer operative times, more blood loss, higher requirement for perioperative transfusion, longer duration of hospitalization and higher morbidity, reoperation, and 90-day mortality rates. CONCLUSIONS: Multiple risk factors were associated with conversion of MILR even for minor hepatectomies, and open conversion was associated with significantly poorer perioperative outcomes.

3.
Colorectal Dis ; 2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38881241

RESUMEN

AIM: Crohn's disease has debilitating effects on patients' quality of life. Currently, there are limited data on the effect of anastomotic configuration on health-related quality of life after ileocaecal resection for Crohn's disease. This study aimed to assess the impact of Kono-S anastomosis on quality of life after ileocolic resection, compared to the conventional side-to-side anastomosis. METHOD: Patients with primary or recurrent Crohn's disease participating in the ongoing SuPREMe-CD trial were interviewed about quality of life using the Inflammatory Bowel Disease Questionnaire (IBDQ). The primary endpoint was disease-specific quality of life, assessed with IBDQ. Secondary outcomes were quality of life related to bowel symptoms, systemic symptoms, social function and emotional function. RESULTS: Of the 94 patients included, 51 (54%) received the conventional side-to-side anastomosis and 43 (46%) the Kono-S anastomosis. Demographics were comparable between the two groups. The IBDQ was assessed at a mean follow-up of 54.0 ± 18.7 months from surgical intervention. The mean total IBDQ score was 155.1 ± 28.07 in the conventional group and 163.8 ± 25.23 in the Kono-S group (P = 0.11). When considering bowel symptoms and social function, mean scores were 50.7 and 23.5 in the conventional group, and 56.3 and 26.5 in the Kono-S group (P = 0.002 and P = 0.02, respectively). Kono-S anastomosis was independently associated with improved quality of life regarding bowel symptoms (P = 0.006) and social function (P = 0.03) after correcting for other confounding factors on linear regression analysis. CONCLUSION: Compared to conventional side-to-side anastomosis, patients with Kono-S anastomosis presented significantly better bowel symptoms and social function scores at 54 months after surgery.

4.
HPB (Oxford) ; 26(5): 682-690, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38342647

RESUMEN

BACKGROUND: Minimally Invasive thermal ablation (MITA) of liver tumors is a commonly performed procedure, alone or in combination with liver resection. Despite being a first-option strategy for small lesions, it is technically demanding, and many concerns still exist about local disease control. METHODS: Consecutive patients undergoing MITA from 1-2019 to 12-2022 were retrospectively enrolled. Risk factors of local recurrence were investigated through univariate and multivariable cox regression analysis. RESULTS: At the multivariable analysis of the 207 nodules undergoing MITA, RFA was associated with worse local Recurrence Free Survival (lRFS) than MWA (HR 2.87 [95 % CI 0.96-8.66], p = 0.05), as well as a concomitant surgical resection (HR 3.89 [95 % CI 1.06-9.77], p = 0.02). A concomitant surgical resection showed worse lRFS in the subgroup analysis of both HCC (HR 3.98 [95 % CI 1.16-13.62], p = 0.02) and CRLM patients (HR 2.68 [95 % CI 0.66-5.92], p = 0.04). Interestingly, a tumor size between 30 and 40 mm was not associated to worse lRFS. CONCLUSION: MWA may reduce the risk of local recurrence in comparison to RFA, while MITA associated to liver resection may face an increased risk of local recurrence. Further prospective studies are needed to confirm such results.


Asunto(s)
Neoplasias Hepáticas , Recurrencia Local de Neoplasia , Humanos , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/patología , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Anciano , Hepatectomía/efectos adversos , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/patología , Procedimientos Quirúrgicos Mínimamente Invasivos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Radiofrecuencia/efectos adversos , Medición de Riesgo
5.
Liver Transpl ; 29(2): 172-183, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36168270

RESUMEN

Precise graft weight (GW) estimation is essential for planning living donor liver transplantation to select grafts of adequate size for the recipient. This study aimed to investigate whether a machine-learning model can improve the accuracy of GW estimation. Data from 872 consecutive living donors of a left lateral sector, left lobe, or right lobe to adults or children for living-related liver transplantation were collected from January 2011 to December 2019. Supervised machine-learning models were trained (80% of observations) to predict GW using the following information: donor's age, sex, height, weight, and body mass index; graft type (left, right, or left lateral lobe); computed tomography estimated graft volume and total liver volume. Model performance was measured in a random independent set (20% of observations) and in an external validation cohort using the mean absolute error (MAE) and the mean absolute percentage error and compared with methods currently available for GW estimation. The best-performing machine-learning model showed an MAE value of 50 ± 62 g in predicting GW, with a mean error of 10.3%. These errors were significantly lower than those observed with alternative methods. In addition, 62% of predictions had errors <10%, whereas errors >15% were observed in only 18.4% of the cases compared with the 34.6% of the predictions obtained with the best alternative method ( p < 0.001). The machine-learning model is made available as a web application ( http://graftweight.shinyapps.io/prediction ). Machine learning can improve the precision of GW estimation compared with currently available methods by reducing the frequency of significant errors. The coupling of anthropometric variables to the preoperatively estimated graft volume seems necessary to improve the accuracy of GW estimation.


Asunto(s)
Trasplante de Hígado , Aprendizaje Automático , Adulto , Niño , Humanos , Trasplante de Hígado/métodos , Donadores Vivos , Tamaño de los Órganos
6.
Liver Transpl ; 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38079264

RESUMEN

Graft survival is a critical end point in adult-to-adult living donor liver transplantation (ALDLT), where graft procurement endangers the lives of healthy individuals. Therefore, ALDLT must be responsibly performed in the perspective of a positive harm-to-benefit ratio. This study aimed to develop a risk prediction model for early (3 months) graft failure (EGF) following ALDLT. Donor and recipient factors associated with EGF in ALDLT were studied using data from the European Liver Transplant Registry. An artificial neural network classification algorithm was trained on a set of 2073 ALDLTs, validated using cross-validation, tested on an independent random-split sample (n=518), and externally validated on United Network for Organ Sharing Standard Transplant Analysis and Research data. Model performance was assessed using the AUC, calibration plots, and decision curve analysis. Graft type, graft weight, level of hospitalization, and the severity of liver disease were associated with EGF. The model ( http://ldlt.shinyapps.io/eltr_app ) presented AUC values at cross-validation, in the independent test set, and at external validation of 0.69, 0.70, and 0.68, respectively. Model calibration was fair. The decision curve analysis indicated a positive net benefit of the model, with an estimated net reduction of 5-15 EGF per 100 ALDLTs. Estimated risks>40% and<5% had a specificity of 0.96 and sensitivity of 0.99 in predicting and excluding EGF, respectively. The model also stratified long-term graft survival ( p <0.001), which ranged from 87% in the low-risk group to 60% in the high-risk group. In conclusion, based on a panel of donor and recipient variables, an artificial neural network can contribute to decision-making in ALDLT by predicting EGF risk.

7.
Ann Surg Oncol ; 30(8): 4783-4796, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37202573

RESUMEN

INTRODUCTION: Despite the advances in minimally invasive (MI) liver surgery, most major hepatectomies (MHs) continue to be performed by open surgery. This study aimed to evaluate the risk factors and outcomes of open conversion during MI MH, including the impact of the type of approach (laparoscopic vs. robotic) on the occurrence and outcomes of conversions. METHODS: Data on 3880 MI conventional and technical (right anterior and posterior sectionectomies) MHs were retrospectively collected. Risk factors and perioperative outcomes of open conversion were analyzed. Multivariate analysis, propensity score matching, and inverse probability treatment weighting analysis were performed to control for confounding factors. RESULTS: Overall, 3211 laparoscopic MHs (LMHs) and 669 robotic MHs (RMHs) were included, of which 399 (10.28%) had an open conversion. Multivariate analyses demonstrated that male sex, laparoscopic approach, cirrhosis, previous abdominal surgery, concomitant other surgery, American Society of Anesthesiologists (ASA) score 3/4, larger tumor size, conventional MH, and Institut Mutualiste Montsouris classification III procedures were associated with an increased risk of conversion. After matching, patients requiring open conversion had poorer outcomes compared with non-converted cases, as evidenced by the increased operation time, blood transfusion rate, blood loss, hospital stay, postoperative morbidity/major morbidity and 30/90-day mortality. Although RMH showed a decreased risk of conversion compared with LMH, converted RMH showed increased blood loss, blood transfusion rate, postoperative major morbidity and 30/90-day mortality compared with converted LMH. CONCLUSIONS: Multiple risk factors are associated with conversion. Converted cases, especially those due to intraoperative bleeding, have unfavorable outcomes. Robotic assistance seemed to increase the feasibility of the MI approach, but converted robotic procedures showed inferior outcomes compared with converted laparoscopic procedures.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Humanos , Masculino , Hepatectomía/efectos adversos , Hepatectomía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Laparoscopía/efectos adversos , Laparoscopía/métodos , Factores de Riesgo , Tiempo de Internación , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento
8.
Surg Endosc ; 37(5): 3439-3448, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36542135

RESUMEN

BACKGROUND: Left lateral sectionectomy (LLS) is one of the most commonly performed minimally invasive liver resections. While laparoscopic (L)-LLS is a well-established technique, over traditional open resection, it remains controversial if robotic (R)-LLS provides any advantages of L-LLS. METHODS: A post hoc analysis of 997 patients from 21 international centres undergoing L-LLS or R-LLS from 2006 to 2020 was conducted. A total of 886 cases (214 R-LLS, 672 L-LLS) met study criteria. 1:1 and 1:2 propensity score matched (PSM) comparison was performed between R-LLS & L-LLS. Further subset analysis by Iwate difficulty was also performed. Outcomes measured include operating time, blood loss, open conversion, readmission rates, morbidity and mortality. RESULTS: Comparison between R-LLS and L-LLS after PSM 1:2 demonstrated statistically significantly lower open conversion rate in R-LLS than L-LLS (0.6% versus 5%, p = 0.009) and median blood loss was also statistically significantly lower in R-LLS at 50 (80) versus 100 (170) in L-LLS (p = 0.011) after PSM 1:1 although there was no difference in the blood transfusion rate. Pringle manoeuvre was also found to be used more frequently in R-LLS, with 53(24.8%) cases versus to 84(12.5%) L-LLS cases (p < 0.001). There was no significant difference in the other key perioperative outcomes such as operating time, length of stay, postoperative morbidity, major morbidity and 90-day mortality between both groups. CONCLUSION: R-LLS was associated with similar key perioperative outcomes compared to L-LLS. It was also associated with significantly lower blood loss and open conversion rates compared to L-LLS.


Asunto(s)
Laparoscopía , Neoplasias Hepáticas , Procedimientos Quirúrgicos Robotizados , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Puntaje de Propensión , Resultado del Tratamiento , Tiempo de Internación , Estudios Retrospectivos , Hepatectomía/métodos , Laparoscopía/métodos , Neoplasias Hepáticas/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía
9.
HPB (Oxford) ; 25(8): 915-923, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37149483

RESUMEN

BACKGROUND: 3D rendering (3DR) represents a promising approach to plan surgical strategies. The study aimed to compare the results of minimally invasive liver resections (MILS) in patients with 3DR versus conventional 2D CT-scan. METHODS: We performed 118 3DR for various indications; the patients underwent a preoperative tri-phasic CT-scan and rendered with Synapse3D® Software. Fifty-six patients undergoing MILS with pre-operative 3DR were compared to a similar cohort of 127 patients undergoing conventional pre-operative 2D CT-scan using the propensity score matching (PSM) analysis. RESULTS: The 3DR mandated pre-operative surgical plan variations in 33.9% cases, contraindicated surgery in 12.7%, providing a new surgical indication in 5.9% previously excluded cases. PSM identified 39 patients in both groups with comparable results in terms of conversion rates, blood loss, blood transfusions, parenchymal R1-margins, grade ≥3 Clavien-Dindo complications, 90-days mortality, and hospital stay respectively in 3DR and conventional 2D. Operative time was significantly increased in the 3DR group (402 vs. 347 min, p = 0.020). Vascular R1 resections were 25.6% vs 7.7% (p = 0.068), while the conversion rate was 0% vs 10.2% (p = 0.058), respectively, for 3DR group vs conventional 2D. CONCLUSION: 3DR may help in surgical planning increasing resectability rate while reducing conversion rates, allowing the precise identification of anatomical landmarks in minimally invasive parenchyma-preserving liver resections.


Asunto(s)
Laparoscopía , Neoplasias Hepáticas , Humanos , Hepatectomía/efectos adversos , Hepatectomía/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Tomografía Computarizada por Rayos X , Estudios Retrospectivos , Complicaciones Posoperatorias/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos
10.
Liver Transpl ; : 172-183, 2022 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-37160073

RESUMEN

ABSTRACT: Precise graft weight (GW) estimation is essential for planning living donor liver transplantation to select grafts of adequate size for the recipient. This study aimed to investigate whether a machine-learning model can improve the accuracy of GW estimation. Data from 872 consecutive living donors of a left lateral sector, left lobe, or right lobe to adults or children for living-related liver transplantation were collected from January 2011 to December 2019. Supervised machine-learning models were trained (80% of observations) to predict GW using the following information: donor's age, sex, height, weight, and body mass index; graft type (left, right, or left lateral lobe); computed tomography estimated graft volume and total liver volume. Model performance was measured in a random independent set (20% of observations) and in an external validation cohort using the mean absolute error (MAE) and the mean absolute percentage error and compared with methods currently available for GW estimation. The best-performing machine-learning model showed an MAE value of 50 ± 62 g in predicting GW, with a mean error of 10.3%. These errors were significantly lower than those observed with alternative methods. In addition, 62% of predictions had errors <10%, whereas errors >15% were observed in only 18.4% of the cases compared with the 34.6% of the predictions obtained with the best alternative method ( p < 0.001). The machine-learning model is made available as a web application ( http://graftweight.shinyapps.io/prediction ). Machine learning can improve the precision of GW estimation compared with currently available methods by reducing the frequency of significant errors. The coupling of anthropometric variables to the preoperatively estimated graft volume seems necessary to improve the accuracy of GW estimation.

11.
Int J Colorectal Dis ; 37(6): 1421-1428, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35599268

RESUMEN

INTRODUCTION: Intra-abdominal abscesses complicating Crohn's disease (CD) present an additional challenge as their presence can contraindicate immunosuppressive treatment whilst emergency surgery is associated with high stoma rate and complications. Treatment options include a conservative approach, percutaneous drainage, and surgical intervention. The current multicentre study audited the short-term outcomes of patients who underwent preoperative radiological drainage of intra-abdominal abscesses up to 6 weeks prior to surgery for ileocolonic CD. METHODS: This is a retrospective, multicentre, observational study promoted by the Italian Society of Colorectal Surgery (SICCR), including all adults undergoing ileocolic resection for primary or recurrent CD from June 2018 to May 2019. The outcomes of patients who underwent radiological guided drainage prior to ileocolonic resection were compared to the patients who did not require preoperative drainage. Postoperative morbidity within 30 days of surgery was the primary endpoint. Postoperative length of hospital stay (LOS) and anastomotic leak rate were the secondary outcomes. RESULTS: Amongst a group of 575 included patients who had an ileocolic resection for CD, there were 36 patients (6.2%) who underwent abscess drainage prior to surgery. Postoperative morbidity (44.4%) and anastomotic leak (11.1%) were significantly higher in the group of patients who underwent preoperative drainage. CONCLUSIONS: Patients with Crohn's disease who require preoperative radiological guided drainage of intra-abdominal abscesses are at increased risk of postoperative morbidity and septic complications following ileocaecal or re-do ileocolic resection.


Asunto(s)
Absceso Abdominal , Enfermedad de Crohn , Absceso Abdominal/complicaciones , Absceso Abdominal/cirugía , Adulto , Fuga Anastomótica/etiología , Fuga Anastomótica/cirugía , Colectomía/efectos adversos , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/cirugía , Drenaje/efectos adversos , Humanos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos
12.
HPB (Oxford) ; 24(2): 143-151, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34625342

RESUMEN

BACKGROUND: Central pancreatectomy is usually performed to excise lesions of the neck or proximal body of the pancreas. In the last decade, thanks to the advent of novel technologies, surgeons have started to perform this procedure robotically. This review aims to appraise the results and outcomes of robotic central pancreatectomies (RCP) through a systematic review and meta-analysis. METHODS: A systematic search of MEDLINE, Embase, and Web Of Science identified studies reporting outcomes of RCP. Pooled prevalence rates of postoperative complications and mortality were computed using random-effect modelling. RESULTS: Thirteen series involving 265 patients were included. In all cases but one, RCP was performed to excise benign or low-grade tumours. Clinically relevant post-operative pancreatic fistula (POPF) occurred in 42.3% of patients. While overall complications were reported in 57.5% of patients, only 9.4% had a Clavien-Dindo score ≥ III. Re-operation was necessary in 0.7% of the patients. New-onset diabetes occurred postoperatively in 0.3% of patients and negligible mortality and open conversion rates were observed. CONCLUSION: RCP is safe and associated with low perioperative mortality and well preserved postoperative pancreatic function, although burdened by high overall morbidity and POPF rates.


Asunto(s)
Neoplasias Pancreáticas , Procedimientos Quirúrgicos Robotizados , Humanos , Páncreas/cirugía , Pancreatectomía/efectos adversos , Pancreatectomía/métodos , Fístula Pancreática/epidemiología , Fístula Pancreática/etiología , Fístula Pancreática/cirugía , Neoplasias Pancreáticas/complicaciones , Neoplasias Pancreáticas/cirugía , Complicaciones Posoperatorias/epidemiología , Procedimientos Quirúrgicos Robotizados/efectos adversos
13.
HPB (Oxford) ; 24(11): 1823-1831, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35654671

RESUMEN

BACKGROUND: During pancreatic resections assessing tumour boundaries and identifying the ideal resection margins can be challenging due to the associated pancreatic gland inflammation and texture. This is particularly true in the context of minimally invasive surgery, where there is a very limited or absent tactile feedback. Indocyanine green (ICG) fluorescence imaging can assist surgeons by simply providing valuable real-time intraoperative information at low cost with minimal side effects. This meta-analysis summarises the available evidence on the use of near-infrared fluorescence imaging with ICG for the intraoperative visualization of pancreatic tumours (PROSPERO ID: CRD42021247203). METHODS: MEDLINE, Embase, and Web Of Science electronic databases were searched to identify manuscripts where ICG was intravenously administered prior to or during pancreatic surgery and reporting the prevalence of pancreatic lesions visualised through fluorescence imaging. RESULTS: Six studies with 7 series' reporting data on 64 pancreatic lesions were included in the analysis. MINOR scores ranged from 6 to 10, with a median of 8. The most frequent indications were pancreatic adenocarcinoma and neuroendocrine tumours. In most cases (67.2%) ICG was administered during surgery. ICG fluorescence identified 48/64 lesions (75%) with 81.3% accuracy, 0.788 (95%CI 0.361-0.961) sensitivity, 1 (95%CI 0.072-1) specificity and positive predictive value of 0.982 (95%CI 0.532-1). In line with the literature, ICG fluorescence identified 5/6 (83.3%) of pancreatic lesions during robotic pancreatic resections performed at our Institution. CONCLUSION: This meta-analysis is the first summarising the results of ICG immunofluorescence in detecting pancreatic tumours during surgery, showing good accuracy. Additional research is needed to define optimal ICG administration strategies and fluorescence intensity cut-offs.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Adenocarcinoma/cirugía , Verde de Indocianina , Imagen Óptica/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Espectroscopía Infrarroja Corta/métodos
14.
HPB (Oxford) ; 24(12): 2086-2095, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35961933

RESUMEN

BACKGROUND: Virtual reality (VR) is increasingly used in surgical education, but evidence of its benefits in complex cognitive training compared to conventional 3-dimensional (3D) visualization methods is lacking. The objective of this study is to assess the impact of 3D liver models rendered visible by VR or desktop interfaces (DIs) on residents' performance in clinical decision-making. METHOD: From September 2020 to April 2021, a single-blinded, crossover randomized educational intervention trial was conducted at two university hospitals in Belgium and Italy. A proficiency-based stepwise curriculum for preoperative liver surgery planning was developed for general surgery residents. After completing the training, residents were randomized in one of two assessment sequences to evaluate ten real clinical scenarios. RESULTS: Among the 50 participants, 46 (23 juniors/23 seniors) completed the training and were randomized. Forty residents (86.96%) achieved proficiency in decision-making. The accuracy of virtual surgical planning using VR was higher than that using DI in both groups A (8.43 ± 1.03 vs 6.86 ± 1.79, p < 0.001) and B (8.08 ± 0.9 vs 6.52 ± 1.37, p < 0.001). CONCLUSION: Proficiency-based curricular training for liver surgery planning successfully resulted in the acquisition of complex cognitive skills. VR was superior to DI visualization of 3D models in decision-making. GOV ID: NCT04959630.


Asunto(s)
Competencia Clínica , Realidad Virtual , Humanos , Curriculum , Hígado , Cognición
15.
Surg Endosc ; 35(3): 1362-1369, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32253556

RESUMEN

INTRODUCTION: There has been a constant increase in the number of published surgical videos with preference for open-access sources, but the proportion of videos undergoing peer-review prior to publication has markedly decreased, raising questions over quality of the educational content presented. The aim of this study was the development and validation of a standard framework for the appraisal of surgical videos submitted for presentation and publication, the LAParoscopic surgery Video Educational GuidelineS (LAP-VEGaS) video assessment tool. METHODS: An international committee identified items for inclusion in the LAP-VEGaS video assessment tool and finalised the marking score utilising Delphi methodology. The tool was finally validated by anonymous evaluation of selected videos by a group of validators not involved in the tool development. RESULTS: 9 items were included in the LAP-VEGaS video assessment tool, with every item scoring from 0 (item not presented in the video) to 2 (item extensively presented in the video), with a total marking score ranging from 0 to 18. The LAP-VEGaS video assessment tool resulted highly accurate in identifying and selecting videos for acceptance for conference presentation and publication, with high level of internal consistency and generalisability. CONCLUSIONS: We propose that peer review in adherence to the LAP-VEGaS video assessment tool could enhance the overall quality of published video outputs.


Asunto(s)
Lista de Verificación , Evaluación Educacional , Guías como Asunto , Laparoscopía/normas , Grabación en Video/normas , Humanos , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
16.
Ann Surg ; 272(2): 210-217, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32675483

RESUMEN

OBJECTIVE: This trial aimed to provide randomized controlled data comparing Kono-S anastomosis and stapled ileocolic side-to-side anastomosis. BACKGROUND: Recently, a new antimesenteric, functional, end-to-end, hand-sewn ileocolic anastomosis (Kono-S) has shown a significant reduction in endoscopic recurrence score and surgical recurrence rate in Crohn disease (CD). METHODS: Randomized controlled trial (RCT) at a tertiary referral institution. Primary endpoint: endoscopic recurrence (ER) (Rutgeerts score ≥i2) after 6 months. Secondary endpoints: clinical recurrence (CR) after 12 and 24 months, ER after 18 months, and surgical recurrence (SR) after 24 months. RESULTS: In all, 79 ileocolic CD patients were randomized in Kono group (36) and Conventional group (43). After 6 months, 22.2% in the Kono group and 62.8% in the Conventional group presented an ER [P < 0.001, odds ratio (OR) 5.91]. A severe postoperative ER (Rutgeerts score ≥i3) was found in 13.8% of Kono versus 34.8% of Conventional group patients (P = 0.03, OR 3.32). CR rate was 8% in the Kono group versus 18% in the Conventional group after 12 months (P = 0.2), and 18% versus 30.2% after 24 months (P = 0.04, OR 3.47). SR rate after 24 months was 0% in the Kono group versus 4.6% in the Conventional group (P = 0.3). Patients with Kono-S anastomosis presented a longer time until CR than patients with side-to-side anastomosis (hazard ratio 0.36, P = 0.037). On binary logistic regression analysis, the Kono-S anastomosis was the only variable significantly associated with a reduced risk of ER (OR 0.19, P < 0.001). There were no differences in postoperative outcomes. CONCLUSIONS: This is the first RCT comparing Kono-S anastomosis and standard anastomosis in CD. The results demonstrate a significant reduction in postoperative endoscopic and clinical recurrence rate for patients who underwent Kono-S anastomosis, and no safety issues.ClinicalTrials.gov ID NCT02631967.


Asunto(s)
Anastomosis Quirúrgica/efectos adversos , Colectomía/métodos , Enfermedad de Crohn/cirugía , Endoscopía/efectos adversos , Mesenterio/patología , Prevención Secundaria/métodos , Adulto , Anciano , Anastomosis Quirúrgica/métodos , Colon/cirugía , Enfermedad de Crohn/diagnóstico , Endoscopía/métodos , Femenino , Estudios de Seguimiento , Humanos , Íleon/cirugía , Modelos Logísticos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Modelos de Riesgos Proporcionales , Recurrencia , Medición de Riesgo , Índice de Severidad de la Enfermedad , Centros de Atención Terciaria , Resultado del Tratamiento
17.
Ann Surg Oncol ; 27(7): 2370-2380, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32060758

RESUMEN

BACKGROUND: Laparoscopic ablation (LA) of colorectal liver metastases (CRLMs) is frequently performed in combination with laparoscopic liver resection or as a stand-alone procedure. However, LA is technically demanding and whether the results are comparable with those of open ablation (OA) has not been determined to date. This study compared the effectiveness of LA and OA in achieving local tumor control of CRLMs. METHODS: Patients undergoing LA or OA of CRLMs at Ghent University Hospital between June 2007 and February 2018 were identified from a prospective database. Lesions treated by LA and OA were matched 1:1 using a propensity score based on lesions (liver segment, size, deepness, proximity to a vessel), patients, and procedural characteristics. Ablation sites were followed up with computed-tomography or magnetic resonance imaging to assess the completeness of the ablation and ablation-site recurrence (ASR). Analysis of ASR was performed with the Kaplan-Meier method and Cox regression. RESULTS: In this study, 163 patients underwent the surgical ablation (78 LA, 85 OA) of 333 CRLMs (143 LA, 190 OA). After matching, 220 lesions (110 LA, 110 OA) were analyzed. Ablation was complete in 93.7% (LA) and 97.3% (OA) of the sites (p = 0.195). No difference in ASR was observed (p = 0.351), with a cumulative risk of ASR at 12 months of 9.1% (LA) and 8.2% (OA). After multivariable analysis, ASR was confirmed to be independent of the surgical approach. CONCLUSION: The findings showed that LA and OA achieve a comparable local control of CRLMs. This result further supports the adoption of a laparoscopic approach for the treatment of CRLMs.


Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales , Neoplasias Hepáticas , Neoplasias Colorrectales/cirugía , Humanos , Laparoscopía , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Recurrencia Local de Neoplasia/cirugía , Puntaje de Propensión , Estudios Retrospectivos , Resultado del Tratamiento
18.
HPB (Oxford) ; 22(8): 1092-1101, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32471694

RESUMEN

BACKGROUND: Pancreatic duct occlusion (PDO) without anastomosis is a technique proposed to mitigate the clinical consequences of postoperative pancreatic fistulas (POPF) after pancreaticoduodenectomy. The aim of this study was to appraise the morbidity following PDO through a systematic review and meta-analysis. METHODS: A systematic search of MEDLINE, Embase, and Web Of Science identified studies reporting outcomes of PDO following pancreaticoduodenectomy. Pooled prevalence rates of postoperative complications and mortality were computed using random-effect modeling. Meta-regression analyses were performed to examine the impact of moderators on the overall estimates. RESULTS: Sixteen studies involving 1000 patients were included. Pooled postoperative mortality was 2.7%. A POPF was reported in 29.7% of the patients. Clinically relevant POPFs occurred in 13.5% of the patients, while intra-abdominal abscess and haemorrhages occurred in 6.7% and 5.5% of the patients, respectively. Re-operation was necessary in 7.6% of the patients. Postoperatively new onset diabetes occurred in 15.8% of patients, more frequently after the use of chemical substances for PDO (p = 0.003). CONCLUSIONS: PDO is associated with significant morbidity including new onset of post-operative diabetes. The risk of new onset post-operative diabetes is associated with the use of chemical substance for PDO. Further evidence is needed to evaluate the potential benefits of PDO in patients at high risk of POPF.


Asunto(s)
Fístula Pancreática , Pancreaticoduodenectomía , Anastomosis Quirúrgica , Humanos , Morbilidad , Conductos Pancreáticos/cirugía , Fístula Pancreática/diagnóstico , Fístula Pancreática/epidemiología , Fístula Pancreática/etiología , Pancreaticoduodenectomía/efectos adversos , Pancreatoyeyunostomía/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía
19.
HPB (Oxford) ; 22(10): 1420-1428, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32057681

RESUMEN

BACKGROUND: Post hepatectomy liver failure (PHLF) after ALPPS has been related to the discrepancy between liver volume and function. Pre-operative hepatobiliary scintigraphy (HBS) can predict post-operative liver function and guide when it is safe to proceed with major hepatectomy. Aim of this study was to evaluate the role of HBS in predicting PHLF after ALPPS, defining a safe cut-off. METHODS: A multicenter retrospective study was approved by the ALPPS Registry. All patients selected for ALPPS between 2012 and 2018, were evaluated. Every patient underwent HBS during ALPPS evaluation. PHLF was reported according to ISGLS definition, considering grade B or C as clinically significant. RESULTS: 98 patients were included. Thirteen patients experienced PHLF grade B or C (14%) following ALPPS-2. The HBS and the daily gain in volume (KGRFLR) of the future liver remnant (FLR) were significantly lower in PHLF B and C (p = .004 and .041 respectively). ROC curves indicated safe cut-offs of 4.1%/day (AUC = 0.68) for KGRFLR, and of 2.7 %/min/m2 (AUC = 0.75) for HBSFLR. Multivariate analysis confirmed these cut-offs as variables predicting PHLF after ALPPS-2. CONCLUSION: Patients presenting a KGRFLR ≤4.1%/day and a HBSFLR ≤2.7%/min/m2 are at high risk of PHLF and their second stage should be re-discussed.


Asunto(s)
Fallo Hepático , Neoplasias Hepáticas , Hepatectomía/efectos adversos , Humanos , Hígado/diagnóstico por imagen , Hígado/cirugía , Fallo Hepático/diagnóstico por imagen , Fallo Hepático/etiología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Vena Porta/diagnóstico por imagen , Vena Porta/cirugía , Cintigrafía , Estudios Retrospectivos
20.
Ann Surg ; 269(6): 1025-1033, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31082898

RESUMEN

OBJECTIVE: To investigate the safety and efficacy of somatostatin as liver inflow modulator in patients with end-stage liver disease (ESLD) and clinically significant portal hypertension (CSPH) undergoing liver transplantation (LT) (ClinicalTrials.gov number,01290172). BACKGROUND: In LT, portal hyperperfusion can severely impair graft function and survival, mainly in cases of partial LT. METHODS: Thirty-three patients undergoing LT for ESLD and CSPH were randomized double-blindly to receive somatostatin or placebo (2:1). The study drug was administered intraoperatively as 5-mL bolus (somatostatin: 500 µg), followed by a 2.5 mL/h infusion (somatostatin: 250 µg/h) for 5 days. Hepatic and systemic hemodynamics were measured, along with liver function tests and clinical outcomes. The ischemia-reperfusion injury (IRI) was analyzed through histological and protein expression analysis. RESULTS: Twenty-nine patients (18 receiving somatostatin, 11 placebo) were included in the final analysis. Ten patients responded to somatostatin bolus, with a significant decrease in hepatic venous portal gradient (HVPG) and portal flow of -28.3% and -29.1%, respectively. At graft reperfusion, HVPG was lower in patients receiving somatostatin (-81.7% vs -58.8%; P = 0.0084), whereas no difference was observed in the portal flow (P = 0.4185). Somatostatin infusion counteracted the decrease in arterial flow (-10% vs -45%; P = 0.0431). There was no difference between the groups in the severity of IRI, incidence of adverse events, long-term complications, graft, and patient survival. CONCLUSIONS: Somatostatin infusion during LT in patients with CSPH is safe, reduces the HVPG, and preserves the arterial inflow to the graft. This study establishes the efficacy of somatostatin as a liver inflow modulator.


Asunto(s)
Enfermedad Hepática en Estado Terminal/complicaciones , Enfermedad Hepática en Estado Terminal/cirugía , Hormonas/uso terapéutico , Hipertensión Portal/tratamiento farmacológico , Trasplante de Hígado , Somatostatina/uso terapéutico , Anciano , Método Doble Ciego , Enfermedad Hepática en Estado Terminal/fisiopatología , Femenino , Humanos , Hipertensión Portal/complicaciones , Masculino , Persona de Mediana Edad , Presión Portal , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA