Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Cell ; 164(3): 433-46, 2016 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-26824656

RESUMEN

The phosphoinositide 3-kinase (PI3K) pathway regulates multiple steps in glucose metabolism and also cytoskeletal functions, such as cell movement and attachment. Here, we show that PI3K directly coordinates glycolysis with cytoskeletal dynamics in an AKT-independent manner. Growth factors or insulin stimulate the PI3K-dependent activation of Rac, leading to disruption of the actin cytoskeleton, release of filamentous actin-bound aldolase A, and an increase in aldolase activity. Consistently, PI3K inhibitors, but not AKT, SGK, or mTOR inhibitors, cause a significant decrease in glycolysis at the step catalyzed by aldolase, while activating PIK3CA mutations have the opposite effect. These results point toward a master regulatory function of PI3K that integrates an epithelial cell's metabolism and its form, shape, and function, coordinating glycolysis with the energy-intensive dynamics of actin remodeling.


Asunto(s)
Fructosa-Bifosfato Aldolasa/metabolismo , Fosfatidilinositol 3-Quinasas/metabolismo , Animales , Neoplasias de la Mama/metabolismo , Línea Celular Tumoral , Citoesqueleto/metabolismo , Citosol/metabolismo , Modelos Animales de Enfermedad , Células Epiteliales/metabolismo , Glucólisis , Humanos , Insulina/metabolismo , Ratones , Inhibidores de las Quinasa Fosfoinosítidos-3 , Transducción de Señal
2.
NMR Biomed ; 34(8): e4560, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34086382

RESUMEN

In many tumors, cancer cells take up large quantities of glucose and metabolize it into lactate, even in the presence of sufficient oxygen to support oxidative metabolism. It has been hypothesized that this malignant metabolic phenotype supports cancer growth and metastasis, and that reversal of this so-called "Warburg effect" may selectively harm cancer cells. Conversion of glucose to lactate can be reduced by ablation or inhibition of lactate dehydrogenase (LDH), the enzyme responsible for conversion of pyruvate to lactate at the endpoint of glycolysis. Recently developed inhibitors of LDH provide new opportunities to investigate the role of this metabolic pathway in cancer. Here we show that magnetic resonance spectroscopic imaging of hyperpolarized pyruvate and its metabolites in models of breast and lung cancer reveal that inhibition of LDH was readily visualized through reduction in label exchange between pyruvate and lactate, while genetic ablation of the LDH-A isoform alone had smaller effects. During the acute phase of LDH inhibition in breast cancer, no discernible bicarbonate signal was observed and small signals from alanine were unchanged.


Asunto(s)
Neoplasias de la Mama/enzimología , Eliminación de Gen , Lactato Deshidrogenasa 5/antagonistas & inhibidores , Lactato Deshidrogenasa 5/genética , Neoplasias Pulmonares/enzimología , Espectroscopía de Resonancia Magnética , Ácido Pirúvico/metabolismo , Animales , Proteína BRCA1/metabolismo , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Lactato Deshidrogenasa 5/metabolismo , Neoplasias Pulmonares/diagnóstico por imagen , Ratones , Transportadores de Ácidos Monocarboxílicos/metabolismo , Proteínas Musculares/metabolismo , Piridonas/administración & dosificación , Piridonas/farmacología , Simportadores/metabolismo , Tiofenos/administración & dosificación , Tiofenos/farmacología
3.
Magn Reson Med ; 78(4): 1362-1372, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-27859618

RESUMEN

PURPOSE: This paper describes a technique that can be used in vivo to measure the dipolar relaxation time, T1D , of macromolecular protons contributing to magnetization transfer (MT) in tissues and to produce quantitative T1D maps. THEORY AND METHODS: The technique builds upon the inhomogeneous MT (ihMT) technique that is particularly sensitive to tissue components with long T1D . A standard ihMT experiment was altered to introduce a variable time for switching between positive and negative offset frequencies for RF saturation. A model for the dependence of ihMT was developed and used to fit data acquired in vivo. RESULTS: Application of the method to images from brains of healthy volunteers produced values of T1D = (5.9 ± 1.2) ms in gray matter and T1D = (6.2 ± 0.4) ms in white matter regions and provided maps of the T1D parameter. CONCLUSION: The model and experiments described provide access to a new relaxation characteristic of tissue with potentially unique diagnostic information. Magn Reson Med 78:1362-1372, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Mapeo Encefálico/métodos , Sustancia Gris/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Humanos , Vaina de Mielina/química , Fantasmas de Imagen , Adulto Joven
4.
Magn Reson Med ; 76(4): 1102-15, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26507361

RESUMEN

PURPOSE: In balanced steady state free precession (bSSFP), the signal intensity has a well-known dependence on the off-resonance frequency, or, equivalently, the phase advance between successive radiofrequency (RF) pulses. The signal profile can be used to resolve the contributions from the spectrally separated metabolites. This work describes a method based on use of a variable RF phase advance to acquire spatial and spectral data in a time-efficient manner for hyperpolarized 13C MRI. THEORY AND METHODS: The technique relies on the frequency response from a bSSFP acquisition to acquire relatively rapid, high-resolution images that may be reconstructed to separate contributions from different metabolites. The ability to produce images from spectrally separated metabolites was demonstrated in vitro, as well as in vivo following administration of hyperpolarized 1-13C pyruvate in mice with xenograft tumors. RESULTS: In vivo images of pyruvate, alanine, pyruvate hydrate, and lactate were reconstructed from four images acquired in 2 s with an in-plane resolution of 1.25 × 1.25 mm(2) and 5 mm slice thickness. CONCLUSION: The phase advance method allowed acquisition of spectroscopically selective images with high spatial and temporal resolution. This method provides an alternative approach to hyperpolarized 13C spectroscopic MRI that can be combined with other techniques such as multiecho or fluctuating equilibrium bSSFP. Magn Reson Med 76:1102-1115, 2016. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Alanina/metabolismo , Espectroscopía de Resonancia Magnética con Carbono-13/métodos , Ácido Láctico/metabolismo , Imagen por Resonancia Magnética/métodos , Neoplasias Experimentales/metabolismo , Ácido Pirúvico/metabolismo , Procesamiento de Señales Asistido por Computador , Células A549 , Algoritmos , Animales , Biomarcadores de Tumor/metabolismo , Isótopos de Carbono/farmacocinética , Línea Celular Tumoral , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Ratones , Ratones Desnudos , Imagen Molecular/métodos , Neoplasias Experimentales/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Radiographics ; 35(6): 1722-37, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26466181

RESUMEN

Magnetic resonance (MR) imaging can provide critical diagnostic and anatomic information while avoiding the use of ionizing radiation, but it has a unique set of safety risks associated with its reliance on large static and changing magnetic fields, high-powered radiofrequency coil systems, and exogenous contrast agents. It is crucial for radiologists to understand these risks and how to mitigate them to protect themselves, their colleagues, and their patients from avoidable harm and to comply with safety regulations at MR imaging sites. Basic knowledge of MR imaging physics and hardware is necessary for radiologists to understand the origin of safety regulations and to avoid common misconceptions that could compromise safety. Each of the components of the MR imaging unit can be a factor in injuries to patients and personnel. Safety risks include translational force and torque, projectile injury, excessive specific absorption rate, burns, peripheral neurostimulation, interactions with active implants and devices, and acoustic injury. Standards for MR imaging device safety terminology were first issued in 2005 and are required by the U.S. Food and Drug Administration, with devices labeled as "MR safe," "MR unsafe," or "MR conditional." MR imaging contrast agent safety is also discussed. Additional technical and safety policies relate to pediatric, unconscious, incapacitated, or pregnant patients and pregnant imaging personnel. Division of the MR imaging environment into four distinct, clearly labeled zones--with progressive restriction of entry and increased supervision for higher zones--is a mandatory and key aspect in avoidance of MR imaging-related accidents. All MR imaging facilities should have a documented plan to handle emergencies within zone IV, including cardiac arrest or code, magnet quench, and fires. Policies from the authors' own practice are provided for additional reference. Online supplemental material is available for this article.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Seguridad del Paciente , Radiología/métodos , Contraindicaciones , Medios de Contraste/efectos adversos , Aprobación de Recursos/normas , Femenino , Humanos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/normas , Masculino , Salud Laboral/normas , Guías de Práctica Clínica como Asunto , Embarazo , Prótesis e Implantes , Gestión de Riesgos
6.
Radiol Imaging Cancer ; 6(2): e230056, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38426887

RESUMEN

Purpose To characterize the metabolomic profiles of two hepatocellular carcinoma (HCC) rat models, track evolution of these profiles to a stimulated tumor state, and assess their effect on lactate flux with hyperpolarized (HP) carbon 13 (13C) MRI. Materials and Methods Forty-three female adult Fischer rats were implanted with N1S1 or McA-RH7777 HCC tumors. In vivo lactate-to-pyruvate ratio (LPR) was measured with HP 13C MRI at 9.4 T. Ex vivo mass spectrometry was used to measure intratumoral metabolites, and Ki67 labeling was used to quantify proliferation. Tumors were first compared with three normal liver controls. The tumors were then compared with stimulated variants via off-target hepatic thermal ablation treatment. All comparisons were made using the Mann-Whitney test. Results HP 13C pyruvate MRI showed greater LPR in N1S1 tumors compared with normal liver (mean [SD], 0.564 ± 0.194 vs 0.311 ± 0.057; P < .001 [n = 9]), but not for McA-RH7777 (P = .44 [n = 8]). Mass spectrometry confirmed that the glycolysis pathway was increased in N1S1 tumors and decreased in McA-RH7777 tumors. The pentose phosphate pathway was also decreased only in McA-RH7777 tumors. Increased proliferation in stimulated N1S1 tumors corresponded to a net increase in LPR (six stimulated vs six nonstimulated, 0.269 ± 0.148 vs 0.027 ± 0.08; P = .009), but not in McA-RH7777 (eight stimulated vs six nonstimulated, P = .13), despite increased proliferation and metastases. Mass spectrometry demonstrated relatively increased lactate production with stimulation in N1S1 tumors only. Conclusion Two HCC subtypes showed divergent glycolytic dependency at baseline and during transformation to a high proliferation state. This metabolic heterogeneity in HCC should be considered with use of HP 13C MRI for diagnosis and tracking. Keywords: Molecular Imaging-Probe Development, Liver, Abdomen/GI, Oncology, Hepatocellular Carcinoma © RSNA, 2024 See also commentary by Ohliger in this issue.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Ratas , Femenino , Animales , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Ácido Pirúvico/metabolismo , Imagen por Resonancia Magnética , Ratas Endogámicas F344 , Lactatos
7.
Cell Mol Gastroenterol Hepatol ; 15(1): 61-75, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36162723

RESUMEN

BACKGROUND & AIMS: Metabolic reprogramming, in particular, glycolytic regulation, supports abnormal survival and growth of hepatocellular carcinoma (HCC) and could serve as a therapeutic target. In this study, we sought to identify glycolytic regulators in HCC that could be inhibited to prevent tumor progression and could also be monitored in vivo, with the goal of providing a theragnostic alternative to existing therapies. METHODS: An orthotopic HCC rat model was used. Tumors were stimulated into a high-proliferation state by use of off-target liver ablation and were compared with lower-proliferating controls. We measured in vivo metabolic alteration in tumors before and after stimulation, and between stimulated tumors and control tumors using hyperpolarized 13C magnetic resonance imaging (MRI) (h13C MRI). We compared metabolic alterations detected by h13C MRI to metabolite levels from ex vivo mass spectrometry, mRNA levels of key glycolytic regulators, and histopathology. RESULTS: Glycolytic lactate flux increased within HCC tumors 3 days after tumor stimulation, correlating positively with tumor proliferation as measured with Ki67. This was associated with a shift towards aerobic glycolysis and downregulation of the pentose phosphate pathway detected by mass spectrometry. MRI-measured lactate flux was most closely coupled with PFKFB3 expression and was suppressed with direct inhibition using PFK15. CONCLUSIONS: Inhibition of PFKFB3 prevents glycolytic-mediated HCC proliferation, trackable by in vivo h13C MRI.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Ratas , Animales , Carcinoma Hepatocelular/patología , Fosfofructoquinasa-2/genética , Fosfofructoquinasa-2/metabolismo , Neoplasias Hepáticas/patología , Proliferación Celular , Glucólisis , Ácido Láctico/metabolismo
8.
Mol Imaging Biol ; 24(5): 769-779, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35467249

RESUMEN

PURPOSE: To evaluate the use of hyperpolarized [1-13C]pyruvate magnetic resonance spectroscopic imaging (HP-13C MRSI) for quantitative measurement of early changes in glycolytic metabolism and its ability to predict response to pan-tyrosine kinase inhibitor (Pan-TKI) therapy in gastric cancer (GCa). PROCEDURES: Pan-TKI afatinib-sensitive NCI-N87 and resistant SNU16 human GCa cells were assessed for GLUT1, hexokinase-II (HKII), lactate dehydrogenase (LDHA), phosphorylated AKT (pAKT), and phosphorylated MAPK (pMAPK) at 0-72 h of treatment with 0.1 µM afatinib. Subcutaneous NCI-N87 tumor-bearing nude mice underwent [18F]FDG PET/MRI and HP-13C MRSI at baseline and 4 days after treatment with afatinib 10 mg/kg/day or vehicle (n = 10/group). Changes in PET and HP-13C MRSI metabolic parameters were compared between the two groups. Imaging findings were correlated with tumor growth and histopathology over 3 weeks of treatment. RESULTS: In vitro analysis showed a continuous decrease in LDHA, pAKT, and pMAPK in NCI-N87 compared to SNU16 cells within 72 h of treatment with afatinib, without a significant change in GLUT1 and HKII in either cell type. [18F]FDG PET of NCI-N87 tumors showed no significant change in PET measures at baseline and day 4 of treatment in either treatment group (SUVmean day 4/day 0: 2.7 ± 0.42/2.34 ± 0.38, p = 0.57 in the treated group vs. 1.73 ± 0.66/2.24 ± 0.43, p = 0.4 in the control group). HP-13C MRSI demonstrated significantly decreased lactate-to-pyruvate ratio (L/P) in treated tumors (L/P day 4/day 0: 0.83 ± 0.30/1.10 ± 0.20, p = 0.012 vs. 0.94 ± 0.20/0.98 ± 0.30, p = 0.75, in the treated vs. control group, respectively). Response to afatinib was confirmed with decreased tumor size over 3 weeks (11.10 ± 16.50 vs. 293.00 ± 79.30 mm3, p < 0.001, treated group vs. control group, respectively) and histopathologic evaluation. CONCLUSIONS: HP-13C MRSI is a more representative biomarker of early metabolic changes in response to pan-TKI in GCa than [18F]FDG PET and could be used for early prediction of response to targeted therapies.


Asunto(s)
Fluorodesoxiglucosa F18 , Neoplasias Gástricas , Animales , Ratones , Humanos , Ácido Pirúvico/metabolismo , Hexoquinasa/metabolismo , Transportador de Glucosa de Tipo 1 , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/tratamiento farmacológico , Proteínas Tirosina Quinasas/metabolismo , Afatinib , Ratones Desnudos , Proteínas Proto-Oncogénicas c-akt/metabolismo , Imagen por Resonancia Magnética/métodos , Inhibidores de Proteínas Quinasas/farmacología , Inhibidores de Proteínas Quinasas/uso terapéutico , Espectroscopía de Resonancia Magnética/métodos , Lactato Deshidrogenasas/metabolismo , Lactatos
9.
J Magn Reson ; 343: 107286, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36075133

RESUMEN

PURPOSE: We constructed a 13C/31P surface coil at 3 T for studying cancer metabolism and bioenergetics. In a single scan session, hyperpolarized 13C-pyruvate MRS and 31P MRS was carried out for a healthy rat brain. METHODS: All experiments were carried out at 3 Tesla. The multinuclear surface coil was designed as two coplanar loops each tuned to either the 13C or 31P operating frequency with an LCC trap on the 13C loop. A commercial volume proton coil was used for anatomical localization and B0 shimming. Single tuned coils operating at either the 13C or 31P frequency were built to evaluate the relative performance of the multinuclear coil. Coil performance metrics consisted of measuring Q factor ratio, calculating system input power using a single-pulse acquisition, and acquiring SNR and flip angle maps using 2D CSI sequences. To observe in vivo spectra, a bolus of hyperpolarized [1-13C] pyruvate was administered via tail vein. In vivo13C and endogenous 31P spectra were obtained in a single scan session using 1D slice selective acquisitions. RESULTS: When compared with single tuned surface coils, the multinuclear coil performance showed a decrease in Q factor ratio, SNR, and transmit efficiency. Flip angle maps showed adequate flip angles within the phantom when the transmit voltage was set using an external phantom. Results show good detection of 13C labeled lactate, alanine, and bicarbonate in addition to ATP from 31P MRS. CONCLUSIONS: The coil enables obtaining complementary information within a scan session, thus reducing the number of trials and minimizing biological variability for studies of metabolism and bioenergetics.


Asunto(s)
Imagen por Resonancia Magnética , Protones , Animales , Ratas , Roedores/metabolismo , Bicarbonatos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Fantasmas de Imagen , Ácido Pirúvico/metabolismo , Lactatos , Alanina , Adenosina Trifosfato , Diseño de Equipo
10.
Theranostics ; 12(18): 7646-7667, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36451861

RESUMEN

Rationale: High mortality in pancreatic cancer (PDAC) and triple negative breast cancer (TNBC) highlight the need to capitalize on nanoscale-design advantages for multifunctional diagnostics and therapies. DNA/RNA-therapies can provide potential breakthroughs, however, to date, there is no FDA-approved systemic delivery system to solid tumors. Methods: Here, we report a Janus-nanoparticle (jNP)-system with modular targeting, payload-delivery, and targeted-imaging capabilities. Our jNP-system consists of 10 nm ultrasmall superparamagnetic iron oxide nanoparticles (USPION) with opposing antibody-targeting and DNA/RNA payload-protecting faces, directionally self-assembled with commercially available zwitterionic microbubbles (MBs) and DNA/RNA payloads. Results: Sonoporation of targeted jNP-payload-MBs delivers functional reporter-DNA imparting tumor-fluorescence, and micro-RNA126 reducing non-druggable KRAS in PDAC-Panc1 and TNBC-MB231 xenografted tumors. The targeting jNP-system enhances ultrasound-imaging of intra-tumoral microvasculature using less MBs/body weight (BW). The jNP-design enhances USPION's T2*-magnetic resonance (MR) and MR-imaging of PDAC-peritoneal metastases using less Fe/BW. Conclusion: Altogether, data advance the asymmetric jNP-design as a potential theranostic Janus-USPION Modular Platform - a JUMP forward.


Asunto(s)
MicroARNs , Neoplasias de la Mama Triple Negativas , Humanos , Medicina de Precisión , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen , Neoplasias de la Mama Triple Negativas/terapia , Diagnóstico por Imagen , ADN , Neoplasias Pancreáticas
11.
Magn Reson Med ; 66(3): 746-55, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21432901

RESUMEN

Contrast agents that can diffuse freely into or within tissue have numerous attractive features for perfusion imaging. Here we present preliminary data illustrating the suitability of hyperpolarized (13)C labeled 2-methylpropan-2-ol (also known as dimethylethanol, tertiary butyl alcohol and tert-butanol) as a freely diffusible contrast agent for magnetic resonance perfusion imaging. Dynamic (13)C images acquired in rat brain with a balanced steady-state free precession sequence following administration of hyperpolarized 2-methylpropan-2-ol show that this agent can be imaged with 2-4 s temporal resolution, 2 mm slice thickness, and 700 µm in-plane resolution while retaining adequate signal-to-noise ratio. (13)C relaxation measurements on 2-methylpropan-2-ol in blood at 9.4 T yield T(1) = 46 ± 4s and T(2) = 0.55 ± 0.03 s. In the rat brain at 4.7 T, analysis of the temporal dynamics of the balanced steady-state free precession image intensity in tissue and venous blood indicate that 2-methylpropan-2-ol has a T(2) of roughly 2-4s and a T(1) of 43 ± 24 s. In addition, the images indicate that 2-methylpropan-2-ol is freely diffusible in brain and hence has a long residence time in tissue; this in turn makes it possible to image the agent continuously for tens of seconds. These characteristics show that 2-methylpropan-2-ol is a promising agent for robust and quantitative perfusion imaging in the brain and body.


Asunto(s)
Mapeo Encefálico/métodos , Medios de Contraste/farmacocinética , Imagen por Resonancia Magnética/métodos , Alcohol terc-Butílico/farmacocinética , Animales , Isótopos de Carbono , Circulación Cerebrovascular , Gadolinio , Compuestos Heterocíclicos/farmacocinética , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Compuestos Organometálicos/farmacocinética , Ratas , Ratas Wistar , Relación Señal-Ruido
12.
Magn Reson Imaging ; 80: 90-97, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33901585

RESUMEN

PURPOSE: Hepatic thermal ablation therapy can result in c-Met-mediated off-target stimulation of distal tumor growth. The purpose of this study was to determine if a similar effect on tumor metabolism could be detected in vivo with hyperpolarized 13C MRI. MATERIALS AND METHODS: In this prospective study, female Fisher rats (n = 28, 120-150 g) were implanted with R3230 rat breast adenocarcinoma cells and assigned to either: sham surgery, hepatic radiofrequency ablation (RFA), or hepatic RFA + adjuvant c-Met inhibition with PHA-665752 (RFA + PHA). PHA-665752 was administered at 0.83 mg/kg at 24 h post-RFA. Tumor growth was measured daily. MRI was performed 24 h before and 72 h after treatment on 14 rats, and the conversion of 13C-pyruvate into 13C-lactate within each tumor was quantified as lactate:pyruvate ratio (LPR). Comparisons of tumor growth and LPR were performed using paired and unpaired t-tests. RESULTS: Hepatic RFA alone resulted in increased growth of the distant tumor compared to sham treatment (0.50 ± 0.13 mm/day versus 0.11 ± 0.07 mm/day; p < 0.001), whereas RFA + PHA (0.06 ± 0.13 mm/day) resulted in no significant change from sham treatment (p = 0.28). A significant increase in LPR was seen following hepatic RFA (+0.016 ± 0.010, p = 0.02), while LPR was unchanged for sham treatment (-0.048 ± 0.051, p = 0.10) or RFA + PHA (0.003 ± 0.041, p = 0.90). CONCLUSION: In vivo hyperpolarized 13C MRI can detect hepatic RFA-induced increase in lactate flux within a distant R3230 tumor, which correlates with increased tumor growth. Adjuvant inhibition of c-Met suppresses these off-target effects, supporting a role for the HGF/c-Met signaling axis in these tumorigenic responses.


Asunto(s)
Ablación por Catéter , Neoplasias Hepáticas , Neoplasias , Animales , Femenino , Hígado/diagnóstico por imagen , Hígado/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Ratas
13.
NMR Biomed ; 23(2): 142-51, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19904727

RESUMEN

The quality of an RF detector coil design is commonly judged on how it compares with other coil configurations. The aim of this article is to develop a tool for evaluating the absolute performance of RF coil arrays. An algorithm to calculate the ultimate intrinsic signal-to-noise ratio (SNR) was implemented for a spherical geometry. The same imaging tasks modeled in the calculations were reproduced experimentally using a 32-element head array. Coil performance maps were then generated based on the ratio of experimentally measured SNR to the ultimate intrinsic SNR, for different acceleration factors associated with different degrees of parallel imaging. The relative performance in all cases was highest near the center of the samples (where the absolute SNR was lowest). The highest performance was found in the unaccelerated case and a maximum of 85% was observed with a phantom whose electrical properties are consistent with values in the human brain. The performance remained almost constant for 2-fold acceleration, but deteriorated at higher acceleration factors, suggesting that larger arrays are needed for effective highly-accelerated parallel imaging. The method proposed here can serve as a tool for the evaluation of coil designs, as well as a tool to guide the development of original designs which may begin to approach the optimal performance.


Asunto(s)
Elementos Químicos , Espectroscopía de Resonancia Magnética/instrumentación , Algoritmos , Electricidad , Estudios de Evaluación como Asunto , Humanos , Fantasmas de Imagen , Propiedades de Superficie
14.
J Orthop Res ; 38(4): 719-725, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31687789

RESUMEN

Magnetic resonance imaging (MRI) and computed tomography (CT) are widely used to image cartilage and their diagnostic capability is enhanced in the presence of contrast agents. The aim of the study is to directly compare the performance between commercial anionic MRI (Gd(DTPA), Gd2-) and CT (Ioxaglate, Iox1-) contrast agents with novel cationic MRI (Gd(DTPA)Lys2 , Gd4+) and CT (CA4+) contrast agents for assessment of cartilage mechanical and biochemical properties using the ex vivo human osteoarthritis metacarpal cartilage model. First, indentation testing was conducted to obtain the compressive modulus of the human fifth metacarpals. The samples were then immersed in the anionic and cationic contrast agents prior to delayed gadolinium-enhanced MRI of cartilage and CT scanning, respectively. The cartilage glycosaminoglycan (GAG) content and distribution were determined using the 1,9-dimethylmethylene blue assay and Safranin-O histology. Cationic agents significantly accumulate in cartilage compared with anionic agents. Significant positive correlations (p < 0.05) exist between imaging results of cationic agents and GAG content (Gd4+: R2 = 0.43; CA4+: R2 = 0.67) and indentation equilibrium modulus (Gd4+: R2 = 0.48; CA4+: R2 = 0.77). Significant negative correlations are observed between anionic MRI relaxation times, but not contrast-enhanced computed tomography attenuation and cartilage GAG content (Gd2-: R2 = 0.56, p < 0.05; Iox1-: R2 = 0.31, p > 0.05) and indentation equilibrium modulus (Gd2-: R2 = 0.38, p < 0.05; Iox1-: R2 = 0.17, p > 0.05). MRI or CT with cationic contrast agents provides greater sensitivity than their anionic analogs at assessing the biochemical and biomechanical properties of ex vivo human metacarpal cartilage. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:719-725, 2020.


Asunto(s)
Medios de Contraste , Articulación Metacarpofalángica/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
15.
Magn Reson Med ; 61(2): 315-34, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19165885

RESUMEN

The promise of increased signal-to-noise ratio and spatial/spectral resolution continues to drive MR technology toward higher magnetic field strengths. SAR management and B1 inhomogeneity correction become critical issues at the high frequencies associated with high field MR. In recent years, multiple coil excitation techniques have been recognized as potentially powerful tools for controlling specific absorption rate (SAR) while simultaneously compensating for B1 inhomogeneities. This work explores electrodynamic constraints on transmit homogeneity and SAR, for both fully parallel transmission and its time-independent special case known as radiofrequency shimming. Ultimate intrinsic SAR--the lowest possible SAR consistent with electrodynamics for a particular excitation profile but independent of transmit coil design--is studied for different field strengths, object sizes, and pulse acceleration factors. The approach to the ultimate intrinsic limit with increasing numbers of finite transmit coils is also studied, and the tradeoff between homogeneity and SAR is explored for various excitation strategies. In the case of fully parallel transmission, ultimate intrinsic SAR shows flattening or slight reduction with increasing field strength, in contradiction to the traditionally cited quadratic dependency, but consistent with established electrodynamic principles.


Asunto(s)
Algoritmos , Diseño Asistido por Computadora , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagen por Resonancia Magnética/instrumentación , Transductores , Simulación por Computador , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Modelos Teóricos , Ondas de Radio , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Magn Reson Med ; 60(4): 895-907, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18816810

RESUMEN

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise ratio and g-factor and is demonstrated for SENSE and GRAPPA reconstructions for accelerated acquisitions that have not previously been amenable to such assessment. Only a simple "prescan" measurement of noise amplitude and correlation in the phased-array receiver, and a single accelerated image acquisition are required, allowing robust assessment of signal-to-noise ratio and g-factor. The "pseudo multiple replica" method has been rigorously validated in phantoms and in vivo, showing excellent agreement with true multiple replica and analytical methods. This method is universally applicable to the parallel imaging reconstruction techniques used in clinical applications and will allow pixel-by-pixel image noise measurements for all parallel imaging strategies, allowing quantitative comparison between arbitrary k-space trajectories, image reconstruction, or noise conditioning techniques.


Asunto(s)
Algoritmos , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
J Magn Reson ; 188(1): 176-82, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17600743

RESUMEN

Recent work has shown that singlet states of two-spin systems in low magnetic fields can have lifetimes up to an order of magnitude longer than the usual spin-lattice relaxation time. This result may enable new applications of NMR, and in particular hyperpolarized NMR via parahydrogen-induced polarization, to the study of slow processes that take place over previously inaccessible timescales. At present it is unclear whether similar results apply to multi-spin systems, or if these long lifetimes are a peculiarity of the two-spin case. Moderately long-lived states have been observed in systems containing more than two spins, although the mechanisms that prolong their lifetimes are not well understood. Here we present formalism for the study of relaxation in multi-spin systems in low magnetic fields. This approach is used to derive a family of quantum-mechanical selection rules governing intramolecular dipolar relaxation at low field that may account for the extended lifetimes observed in multi-spin systems.


Asunto(s)
Algoritmos , Espectroscopía de Resonancia Magnética/métodos , Modelos Teóricos
18.
Elife ; 52016 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-27156560

RESUMEN

The axolotl can regenerate multiple organs, including the brain. It remains, however, unclear whether neuronal diversity, intricate tissue architecture, and axonal connectivity can be regenerated; yet, this is critical for recovery of function and a central aim of cell replacement strategies in the mammalian central nervous system. Here, we demonstrate that, upon mechanical injury to the adult pallium, axolotls can regenerate several of the populations of neurons present before injury. Notably, regenerated neurons acquire functional electrophysiological traits and respond appropriately to afferent inputs. Despite the ability to regenerate specific, molecularly-defined neuronal subtypes, we also uncovered previously unappreciated limitations by showing that newborn neurons organize within altered tissue architecture and fail to re-establish the long-distance axonal tracts and circuit physiology present before injury. The data provide a direct demonstration that diverse, electrophysiologically functional neurons can be regenerated in axolotls, but challenge prior assumptions of functional brain repair in regenerative species.


Asunto(s)
Ambystoma mexicanum , Lesiones Encefálicas , Encéfalo/fisiología , Regeneración , Animales
19.
JCI Insight ; 1(9): e87415, 2016 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-27699275

RESUMEN

Radiation therapy (RT), a critical modality in the treatment of lung cancer, induces direct tumor cell death and augments tumor-specific immunity. However, despite initial tumor control, most patients suffer from locoregional relapse and/or metastatic disease following RT. The use of immunotherapy in non-small-cell lung cancer (NSCLC) could potentially change this outcome by enhancing the effects of RT. Here, we report significant (up to 70% volume reduction of the target lesion) and durable (up to 12 weeks) tumor regressions in conditional Kras-driven genetically engineered mouse models (GEMMs) of NSCLC treated with radiotherapy and a programmed cell death 1 antibody (αPD-1). However, while αPD-1 therapy was beneficial when combined with RT in radiation-naive tumors, αPD-1 therapy had no antineoplastic efficacy in RT-relapsed tumors and further induced T cell inhibitory markers in this setting. Furthermore, there was differential efficacy of αPD-1 plus RT among Kras-driven GEMMs, with additional loss of the tumor suppressor serine/threonine kinase 11/liver kinase B1 (Stk11/Lkb1) resulting in no synergistic efficacy. Taken together, our data provide evidence for a close interaction among RT, T cells, and the PD-1/PD-L1 axis and underscore the rationale for clinical combinatorial therapy with immune modulators and radiotherapy.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/terapia , Inmunoterapia , Neoplasias Pulmonares/terapia , Receptor de Muerte Celular Programada 1/antagonistas & inhibidores , Proteínas Quinasas Activadas por AMP , Animales , Anticuerpos Monoclonales/uso terapéutico , Antineoplásicos , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Línea Celular Tumoral , Femenino , Neoplasias Pulmonares/radioterapia , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Recurrencia Local de Neoplasia , Proteínas Serina-Treonina Quinasas/genética , Proteínas Proto-Oncogénicas p21(ras)/genética
20.
J Magn Reson ; 176(2): 187-98, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16027017

RESUMEN

A generalized method for phase-constrained parallel MR image reconstruction is presented that combines and extends the concepts of partial-Fourier reconstruction and parallel imaging. It provides a framework for reconstructing images employing either or both techniques and for comparing image quality achieved by varying k-space sampling schemes. The method can be used as a parallel image reconstruction with a partial-Fourier reconstruction built in. It can also be used with trajectories not readily handled by straightforward combinations of partial-Fourier and SENSE-like parallel reconstructions, including variable-density, and non-Cartesian trajectories. The phase constraint specifies a better-conditioned inverse problem compared to unconstrained parallel MR reconstruction alone. This phase-constrained parallel MRI reconstruction offers a one-step alternative to the standard combination of homodyne and SENSE reconstructions with the added benefit of flexibility of sampling trajectory. The theory of the phase-constrained approach is outlined, and its calibration requirements and limitations are discussed. Simulations, phantom experiments, and in vivo experiments are presented.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Metodologías Computacionales , Análisis de Fourier , Humanos , Almacenamiento y Recuperación de la Información/métodos , Imagen por Resonancia Magnética/instrumentación , Análisis Numérico Asistido por Computador , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA