Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Herz ; 43(5): 406-414, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29808277

RESUMEN

End-stage heart failure is associated with significant morbidity and mortality. Heart transplantation has the potential to offer a return to daily activities for critically ill patients and is the gold standard therapy. However, heart transplantations are decreasing yearly with a historic low in Germany in 2017. By striking contrast, both waiting list numbers and waiting time have increased owing to a lack of acceptable donor organs. Ventricular assist devices (VAD) represent a reasonable therapeutic alternative for patients on heart transplantation waiting lists. Patients ineligible for transplantation may undergo VAD implantation as a destination therapy. However, the necessity for life-long anticoagulation must be weighed against bleeding complications in potential VAD candidates. VAD-dependent patients also face risks of driveline infections, in addition to restricted activities of daily living owing to limited battery capacities. Given Germany's low transplantation rate, VAD implantation may serve as a middle ground. With the recent events in transplantation medicine, trust among the German population has declined. Transplant centers must ensure graft quality and ongoing care, define minimum caseload for accreditation, and implement specialty care units in heart failure. Furthermore, the legislation shift from extended consent to dissent solution has the potential to end donor organ shortage.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Actividades Cotidianas , Adulto , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad
2.
Technol Health Care ; 26(1): 69-80, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28968250

RESUMEN

BACKGROUND: Survival rates of out-of-hospital cardiac arrest remain poor. Bystander cardiopulmonary resuscitation (CPR) is crucial for survival and feedback devices could improve its quality. OBJECTIVE: We investigated the quality of chest compression when using the Cardio First AngelTM (CFA) feedback device compared to standard basic life support (BLS). The analysis focused on laymen. METHODS: Laymen without (n= 43) and with (n= 96) explanation of the device, medical students (n= 128) and medical staff (n= 27) performed 60 seconds of standard versus assisted chest compression using the CFA on a resuscitation manikin. Compression frequency, depth and position were analyzed according to current guidelines. RESULTS: Laymen showed significantly better success rates regarding correct compression depth when using the CFA (23.3% vs. 55.8%, p= 0.004 and 25.0% vs. 52.1%, p< 0.001, laymen without and with explanation of the device, respectively). Medical students likewise improved (22.7% vs. 42.2%, p= 0.004). Hand positioning was 100% correct in all groups with the device. Improvement in frequency yielded by the CFA was more pronounced for probands with fears of contact (p= 0.02). The benefit of using the device did not differ significantly in laymen with or without explanation. CONCLUSIONS: Chest compression as performed by laymen was significantly improved with regard to compression depth when using the CFA for guidance and feedback. With the device, no cases of incorrect hand positioning occurred in any group.


Asunto(s)
Reanimación Cardiopulmonar/educación , Reanimación Cardiopulmonar/normas , Maniquíes , Adolescente , Adulto , Anciano , Estudios Cruzados , Femenino , Humanos , Masculino , Cuerpo Médico de Hospitales , Persona de Mediana Edad , Estudiantes de Medicina , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA