Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 98(2): E262-E274, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33780150

RESUMEN

OBJECTIVE: We compared 5-year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post-approval study (PAS) and the investigational device exemption (IDE) trial. BACKGROUND: As a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a "real-world" environment. The 5-year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared. METHODS: The cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time-related outcomes and valve-related adverse events were compared between the two trials with Kaplan-Meier curves and log-rank testing. RESULTS: 167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both. CONCLUSIONS: Hemodynamic and time-related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real-world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post-approval studies as part of the regulatory process for Class III medical devices.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/cirugía , Resultado del Tratamiento , Adulto Joven
2.
Catheter Cardiovasc Interv ; 91(3): 485-494, 2018 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-29193671

RESUMEN

BACKGROUND: Since FDA approval of the Melody valve, transcatheter pulmonary valve replacement (TPVR) has been offered to an expanding population. Limited data exist regarding the safety and feasibility of TPVR in smaller patients. METHODS: All patients weighing <20 kg who underwent catheterization for percutaneous TPVR at four centers were reviewed. RESULTS: Of the 51 patients reviewed, 43 (84%) had successful valve implantation and 8 (16%) were found not to be candidates due to access veins too small (n = 3), coronary artery/aortic root compression (n = 3), and RVOT too large (n = 2). The 43 patients who underwent successful percutaneous TPVR had a median age and weight of 5.8 years (3.3-10) and 17.7 kg (13.5-19.8), and most had tetralogy of Fallot (TOF). TPVR was performed via femoral vein (FV) access in 24 patients and internal jugular vein (IJV) access in 19 patients. Median weight in patients with IJV implant was 1.1 kg lower than those who underwent transfemoral implant (17.0 vs. 18.1 kg, P = 0.05). There were four adverse events: one iliac vein injury, one contained MPA tear, and two patients with post-procedure femoral vein bleeding. All patients were alive at recent follow-up, a median of 2.0 years (0.1-6.0) after TPVR. There was excellent valve function with mean Doppler gradients of 3-20 mm Hg, and trivial or mild pulmonary regurgitation in all but one patient. There were no RVOT reinterventions and no cases of endocarditis. CONCLUSIONS: Percutaneous TPVR can be safely performed in patients <20 kg. The procedure frequently requires IJV access, and access site/bleeding complications may be more common in this cohort.


Asunto(s)
Peso Corporal , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Factores de Edad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Niño , Desarrollo Infantil , Preescolar , Angiografía Coronaria , Ecocardiografía Doppler , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Válvula Pulmonar/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos
3.
Circulation ; 131(22): 1960-70, 2015 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-25944758

RESUMEN

BACKGROUND: Studies of transcatheter pulmonary valve (TPV) replacement with the Melody valve have demonstrated good short-term outcomes, but there are no published long-term follow-up data. METHODS AND RESULTS: The US Investigational Device Exemption trial prospectively enrolled 171 pediatric and adult patients (median age, 19 years) with right ventricular outflow tract conduit obstruction or regurgitation. The 148 patients who received and were discharged with a TPV were followed up annually according to a standardized protocol. During a median follow-up of 4.5 years (range, 0.4-7 years), 32 patients underwent right ventricular outflow tract reintervention for obstruction (n=27, with stent fracture in 22), endocarditis (n=3, 2 with stenosis and 1 with pulmonary regurgitation), or right ventricular dysfunction (n=2). Eleven patients had the TPV explanted as an initial or second reintervention. Five-year freedom from reintervention and explantation was 76±4% and 92±3%, respectively. A conduit prestent and lower discharge right ventricular outflow tract gradient were associated with longer freedom from reintervention. In the 113 patients who were alive and reintervention free, the follow-up gradient (median, 4.5 years after implantation) was unchanged from early post-TPV replacement, and all but 1 patient had mild or less pulmonary regurgitation. Almost all patients were in New York Heart Association class I or II. More severely impaired baseline spirometry was associated with a lower likelihood of improvement in exercise function after TPV replacement. CONCLUSIONS: TPV replacement with the Melody valve provided good hemodynamic and clinical outcomes up to 7 years after implantation. Primary valve failure was rare. The main cause of TPV dysfunction was stenosis related to stent fracture, which was uncommon once prestenting became more widely adopted. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870.


Asunto(s)
Cateterismo Cardíaco/tendencias , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Hemodinámica , Insuficiencia de la Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Niño , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/epidemiología , Resultado del Tratamiento , Estados Unidos/epidemiología , Obstrucción del Flujo Ventricular Externo/diagnóstico , Obstrucción del Flujo Ventricular Externo/epidemiología , Adulto Joven
4.
Catheter Cardiovasc Interv ; 85(5): 847-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25257952

RESUMEN

Trans-catheter balloon angioplasty is a well-established treatment modality for pulmonary artery (PA) stenosis in children with congenital heart disease. We report a case of an unusual complication where a fistula developed between the left PA and the left atrium during balloon angioplasty in a patient with history of tetralogy of Fallot. This was successfully treated with placement of a covered stent.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Atrios Cardíacos/lesiones , Cardiopatías Congénitas/cirugía , Enfermedad Iatrogénica , Arteria Pulmonar/lesiones , Fístula Vascular/etiología , Procedimientos Quirúrgicos Vasculares/métodos , Angiografía , Ecocardiografía , Humanos , Lactante , Masculino , Complicaciones Posoperatorias , Reoperación , Stents , Fístula Vascular/diagnóstico , Fístula Vascular/cirugía
5.
Echocardiography ; 32(3): 541-7, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25039533

RESUMEN

BACKGROUND: Quantitative assessment of right ventricular (RV) function is important for the management of patients with congenital heart disease. Tissue Doppler (TDI)-derived myocardial acceleration during isovolumic contraction (IVA) is an echocardiographic measure of contractility that is independent of loading conditions. The aim of this study was to establish normative data for IVA at the lateral tricuspid valve annulus (RV IVA). METHODS: This is a retrospective study of 340 children who had normal echocardiograms. We analyzed RV IVA in relation to age, body surface area (BSA), gender, heart rate (HR), tricuspid annular plane systolic excursion (TAPSE), and TDI-derived S' (RV S'). RESULTS: RV IVA showed a positive correlation with HR (r = 0.58, P<0.001) and a negative correlation with age and BSA (r = -0.44, P<0.001, for both). RV IVA ranged from 2.3 m/sec(2) (±2 SD: 1-3.7 m/sec(2) ) at a HR of <60 beats per minute (bpm) to 4.9 m/sec(2) (±2 SD: 3.5-6.4 m/sec(2) ) at a HR of >160 bpm. When RV IVA was corrected for HR (RV IVAc), it became independent of HR, age, BSA, and gender. The mean RV IVAc was 2.3 m/sec(1.5) (±2 SD: 1.1-3.6 m/sec(1.5) ). There was a correlation of normalized RV IVAc with normalized TAPSE and RV S'. CONCLUSION: RV IVA, a marker of RV contractility, shows a strong dependence on HR. HR corrected RV IVA (RV IVAc) is independent of age, BSA, gender, and HR. We suggest measuring RV IVAc routinely in patients at risk for RV dysfunction.


Asunto(s)
Ecocardiografía/métodos , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Función Ventricular Derecha/fisiología , Aceleración , Envejecimiento/fisiología , Niño , Connecticut , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Pediatr Cardiol ; 33(7): 1183-6, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22354225

RESUMEN

The reported case involved a 7-year-old girl with congenitally corrected transposition of the great arteries (ccTGA) and situs inversus who after surgical management experienced symptoms of dyspnea and left-sided obstructive heart disease. Her symptoms, chest X-ray, and cardiac catheterization demonstrated pulmonary venous obstruction, a known but rare complication associated with intra-atrial baffle obstruction. The incidence of the reported disorder, the follow-up assessment, and the current literature regarding complications of Senning/Mustard surgery are discussed in the context of patients with ccTGA.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Enfermedad Veno-Oclusiva Pulmonar/diagnóstico por imagen , Situs Inversus/cirugía , Transposición de los Grandes Vasos/cirugía , Niño , Transposición Congénitamente Corregida de las Grandes Arterias , Ecocardiografía , Femenino , Humanos , Radiografía
7.
Circ Cardiovasc Interv ; 15(1): e010852, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34930015

RESUMEN

BACKGROUND: The Melody valve was developed to extend the useful life of previously implanted right ventricular outflow tract (RVOT) conduits or bioprosthetic pulmonary valves, while preserving RV function and reducing the lifetime burden of surgery for patients with complex congenital heart disease. METHODS: Enrollment for the US Investigational Device Exemption study of the Melody valve began in 2007. Extended follow-up was completed in 2020. The primary outcome was freedom from transcatheter pulmonary valve (TPV) dysfunction (freedom from reoperation, reintervention, moderate or severe pulmonary regurgitation, and/or mean RVOT gradient >40 mm Hg). Secondary end points included stent fracture, catheter reintervention, surgical conduit replacement, and death. RESULTS: One hundred seventy-one subjects with RVOT conduit or bioprosthetic pulmonary valve dysfunction were enrolled. One hundred fifty underwent Melody TPV replacement. Median age was 19 years (Q1-Q3: 15-26). Median discharge mean RVOT Doppler gradient was 17 mm Hg (Q1-Q3: 12-22). The 149 patients implanted >24 hours were followed for a median of 8.4 years (Q1-Q3: 5.4-10.1). At 10 years, estimated freedom from mortality was 90%, from reoperation 79%, and from any reintervention 60%. Ten-year freedom from TPV dysfunction was 53% and was significantly shorter in children than in adults. Estimated freedom from TPV-related endocarditis was 81% at 10 years (95% CI, 69%-89%), with an annualized rate of 2.0% per patient-year. CONCLUSIONS: Ten-year outcomes from the Melody Investigational Device Exemption trial affirm the benefits of Melody TPV replacement in the lifetime management of patients with RVOT conduits and bioprosthetic pulmonary valves by providing sustained symptomatic and hemodynamic improvement in the majority of patients. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00740870.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Adolescente , Adulto , Humanos , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
8.
Circulation ; 122(5): 507-16, 2010 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-20644013

RESUMEN

BACKGROUND: Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. METHODS AND RESULTS: From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (>or=1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8+/-4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5+/-2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. CONCLUSIONS: In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Cateterismo Cardíaco/métodos , Niño , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Falla de Prótesis , Atresia Pulmonar/diagnóstico por imagen , Atresia Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Radiografía , Stents/estadística & datos numéricos , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Resultado del Tratamiento , Estados Unidos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Adulto Joven
10.
Congenit Heart Dis ; 13(1): 140-146, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29148206

RESUMEN

OBJECTIVE: Trans-catheter (TC) pulmonary valve replacement (PVR) has become common practice for patients with right ventricular outflow tract obstruction (RVOTO) and/or pulmonic insufficiency (PI). Our aim was to compare PVR and right ventricular (RV) function of patients who received TC vs surgical PVR. DESIGN: Retrospective review of echocardiograms obtained at three time points: before, immediately after PVR, and most recent. PATIENTS: Sixty-two patients (median age 19 years, median follow-up 25 months) following TC (N = 32) or surgical (N = 30) PVR at Yale-New Haven Hospital were included. OUTCOME MEASURES: Pulmonary valve and right ventricular function before, immediately after, and most recently after PVR. RESULTS: At baseline, the TC group had predominant RVOTO (74% vs 10%, P < .001), and moderate-severe PI was less common (61% vs 100%, P < .001). Immediate post-procedural PVR function was good throughout. At last follow-up, the TC group had preserved valve function, but the surgical group did not (moderate RVOTO: 6% vs 41%, P < .001; >mild PI: 0% vs 24%, P = .003). Patients younger than 17 years at surgical PVR had the highest risk of developing PVR dysfunction, while PVR function in follow-up was similar in adults. Looking at RV size and function, both groups had a decline in RV size following PVR. However, while RV function remained stable in the TC group, there was a transient postoperative decline in the surgical group. CONCLUSIONS: TC PVR in patients age <17 years is associated with better PVR function in follow-up compared to surgical valves. There was a transient decline in RV function following surgical but not TC PVR. TC PVR should therefore be the first choice in children who are considered for PVR, whenever possible.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ventrículos Cardíacos/fisiopatología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Válvula Pulmonar/cirugía , Función Ventricular Derecha/fisiología , Remodelación Ventricular/fisiología , Adolescente , Adulto , Cateterismo Cardíaco/métodos , Niño , Preescolar , Ecocardiografía , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/cirugía , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
J Am Coll Cardiol ; 72(22): 2717-2728, 2018 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-30497557

RESUMEN

BACKGROUND: Endocarditis has emerged as one of the most concerning adverse outcomes in patients with congenital anomalies involving the right ventricular outflow tract (RVOT) and prosthetic valves. OBJECTIVES: The aim of this study was to evaluate rates and potential risk factors for endocarditis after transcatheter pulmonary valve replacement in the prospective Melody valve trials. METHODS: All patients in whom a transcatheter pulmonary valve (TPV) was implanted in the RVOT as part of 3 prospective multicenter studies comprised the analytic cohort. The diagnosis of endocarditis and involvement of the TPV were determined by the implanting investigator. RESULTS: A total of 309 patients underwent transcatheter pulmonary valve replacement (TPVR) and were discharged with a valve in place. The median follow-up duration was 5.1 years, and total observation until study exit was 1,660.3 patient-years. Endocarditis was diagnosed in 46 patients (median 3.1 years after TPVR), and a total of 35 patients were reported to have TPV-related endocarditis (34 at the initial diagnosis, 1 with a second episode). The annualized incidence rate of endocarditis was 3.1% per patient-year and of TPV-related endocarditis was 2.4% per patient-year. At 5 years post-TPVR, freedom from a diagnosis of endocarditis was 89% and freedom from TPV-related endocarditis was 92%. By multivariable analysis, age ≤12 years at implant (hazard ratio: 2.3; 95% confidence interval: 1.2 to 4.4; p = 0.011) and immediate post-implant peak gradient ≥15 mm Hg (2.7; 95% confidence interval: 1.4 to 4.9; p = 0.002) were associated with development of endocarditis and with development of TPV-related endocarditis (age ≤12 years: 2.8; 95% confidence interval: 1.3 to 5.7; p = 0.006; gradient ≥15 mm Hg: 2.6; 95% confidence interval: 1.3 to 5.2; p = 0.008). CONCLUSIONS: Endocarditis is an important adverse outcome following TVPR in children and adults with post-operative congenital heart disease involving the RVOT. Ongoing efforts to understand, prevent, and optimize management of this complication are paramount in making the best use of TPV therapy. (Melody Transcatheter Pulmonary Valve [TPV] Study: Post Approval Study of the Original Investigational Device Exemption [IDE] Cohort; NCT00740870; Melody Transcatheter Pulmonary Valve Post-Approval Study; NCT01186692; and Melody Transcatheter Pulmonary Valve [TPV] Post-Market Surveillance Study; NCT00688571).


Asunto(s)
Endocarditis Bacteriana/etiología , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adolescente , Adulto , Niño , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Contaminación de Equipos , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/microbiología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/epidemiología , Adulto Joven
12.
JACC Cardiovasc Interv ; 10(17): 1746-1759, 2017 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-28823778

RESUMEN

OBJECTIVES: This study sought to evaluate the incidence of and risk factors for conduit and stent-related outcomes following transcatheter pulmonary valve replacement (TPVR). BACKGROUND: Stent fracture (SF) and right ventricular outflow tract (RVOT) reintervention are among the most important adverse outcomes after TPVR using the Melody valve (Medtronic, Minneapolis, Minnesota). The conduit environment and conduit preparation practices vary among patients who undergo TPVR. METHODS: Data from 3 prospective Melody valve multicenter studies were pooled and analyzed. All patients who had successful implant of a Melody valve that was present at hospital discharge comprised the study cohort; patients who had TPVR into a stentless conduit comprised the analysis cohort. SF was diagnosed using protocol-specified or clinical fluoroscopy or radiography, and classified as major or minor. RESULTS: Of 358 patients who underwent catheterization with intent to perform TPVR, 309 were discharged with the Melody valve in place (study cohort) of which 251 patients had TPVR into a stentless conduit (analysis cohort). Median follow-up was 5 years. New pre-stents were placed in 68% of patients with a stentless conduit, and 22% received multiple pre-stents. At 3 years, freedom from any SF and major SF was 74 ± 3% and 85 ± 2%, respectively, and freedom from RVOT reintervention was 85 ± 2%. New pre-stents were associated with longer freedom from SF and RVOT reintervention than was no pre-stent. CONCLUSIONS: Risks of SF and reintervention after TPVR with a Melody valve were reduced by implantation of pre-stents, which has become standard practice. This study supports pre-stenting as an important component of TPVR therapy.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Válvula Pulmonar/cirugía , Stents , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Niño , Bases de Datos Factuales , Supervivencia sin Enfermedad , Europa (Continente) , Femenino , Cardiopatías Congénitas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , América del Norte , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/fisiopatología , Adulto Joven
13.
Am J Cardiol ; 120(8): 1387-1392, 2017 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-28823485

RESUMEN

This early feasibility study was designed to obtain in vivo data to confirm assumptions on device loading conditions of the Medtronic Harmony transcatheter pulmonary valve (TPV). Secondary objectives included procedural feasibility, safety, and valve performance. The Harmony TPV was developed for nonsurgical pulmonary valve replacement in non-right ventricle-pulmonary artery conduit patients. The Native Outflow Tract TPV Research Clinical Study was the first study approved under the Food and Drug Administration Early Feasibility Study guidance. Enrollment required that patient anatomy be precisely matched to the single-size Harmony TPV implant, necessitating a rigorous selection process. The study was nonrandomized, prospective, and performed at 3 sites. All patients met standard indications for surgical pulmonary valve replacement. The goal of the screening committee was to match the candidate anatomy to predetermined engineering criteria thought to be predictive of secure Harmony TPV implantation for the single-size device under study. A majority of the screening committee was required to recommend a patient as eligible for implant. A total of 270 patients underwent prescreening cardiac magnetic resonance imaging, 66 were enrolled and received a computed tomography scan (24%), 21 met criteria for implant and were catheterized (8%), and 20 underwent implant. Nineteen of 20 met criteria for implant success. In conclusion, the Medtronic Harmony TPV represents an emerging therapeutic option for patients with complex postoperative right ventricular outflow tract failure. The initial clinical evaluation of this technology was unique, and the highly variable anatomy of this population required careful screening to ensure acceptable device fit.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Selección de Paciente , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adulto , Estudios Clínicos como Asunto , Ecocardiografía , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Estudios Prospectivos , Insuficiencia de la Válvula Pulmonar/diagnóstico , Factores de Tiempo , Resultado del Tratamiento
14.
Am Heart J ; 152(5): 1004.e9-17, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17070181

RESUMEN

OBJECTIVE: To determine the experience with anomalous right coronary artery arising from the pulmonary artery (ARCAPA) at our institution. BACKGROUND: Anomalous right coronary artery from the pulmonary artery is a rare congenital defect affecting 0.002% of the population. Unlike anomalous left coronary artery from the pulmonary artery (ALCAPA), ARCAPA generally has not been considered to be a lethal defect in infancy or childhood, although case reports of sudden death exist. The natural history of ARCAPA is difficult to describe because of the relatively small number of cases reported. Medical knowledge of this defect has been collected from case reports alone. No pediatric series of ARCAPA has been published. METHODS: Hospital databases were retrospectively searched for cases of ARCAPA diagnosed at the New York Presbyterian Hospital over the past 25 years. A comprehensive literature search for case reports of ARCAPA was performed. RESULTS: Seven pediatric cases are described. The cases range in clinical presentation from a young infant with tetralogy of Fallot to an adolescent with chest pain on exertion. Only 1 patient came to medical attention because of chest pain; 6 patients were asymptomatic. In these 6, ARCAPA was diagnosed upon evaluation of either a murmur (3) or associated congenital heart disease (3). All 7 patients have undergone repair. One patient died after repair of complex tetralogy of Fallot/pulmonary atresia. One patient developed a thrombus in the dilated right coronary artery years after repair. The thrombus resolved with anticoagulation. CONCLUSIONS: Anomalous right coronary artery from the pulmonary artery is an uncommon coronary anomaly that, unlike ALCAPA, rarely leads to sudden death. Surgical correction is low risk and should be considered for all patients.


Asunto(s)
Anomalías de los Vasos Coronarios , Arteria Pulmonar/anomalías , Niño , Preescolar , Anomalías de los Vasos Coronarios/mortalidad , Anomalías de los Vasos Coronarios/cirugía , Vasos Coronarios , Bases de Datos como Asunto , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos
15.
J Am Coll Cardiol ; 68(14): 1525-35, 2016 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-27687194

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is a common and important comorbidity in patients with postoperative right ventricular outflow tract (RVOT) obstruction or pulmonary regurgitation (PR). Transcatheter pulmonary valve replacement (TPVR) has become a useful tool in the management of postoperative RVOT obstruction and PR, but it is unknown whether relief of the right ventricular volume and/or pressure overload by TPVR will have a beneficial effect on TR, as is often seen with surgical pulmonary valve replacement. OBJECTIVES: This study sought to assess the prevalence of and factors associated with significant TR in patients undergoing TPVR for RVOT obstruction or PR. METHODS: Data were combined from 3 prospective multicenter trials of patients referred for TPVR. Follow-up data through 5 years post-implantation were analyzed. RESULTS: Of 300 patients studied, 77 (25.6%) had moderate or severe TR at baseline. After TPVR, TR severity was improved in 65% of those patients, and more than one-half had mild TR or less TR at discharge. Of 13 patients with severe TR pre-implantation, only 1 had severe TR at 1-year follow-up and beyond. Moderate or severe baseline TR was associated with shorter freedom from RVOT reintervention after TPVR. CONCLUSIONS: In this prospective multicenter study of post-operative patients with RVOT obstruction and/or PR, TR was common. In patients with significant baseline TR, TPVR resulted in clinically relevant acute reductions in TR that persisted over at least 5 years of follow-up. These observations support the application of TPVR therapy in patients with RVOT obstruction or PR who are anatomically suitable, even in the setting of significant concomitant TR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Niño , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Insuficiencia de la Válvula Pulmonar/complicaciones , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide/complicaciones , Obstrucción del Flujo Ventricular Externo/complicaciones , Adulto Joven
16.
Circulation ; 110(5): 501-7, 2004 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-15262841

RESUMEN

BACKGROUND: Our purpose was to describe a 13-year experience with patients undergoing transcatheter device closure of unrepaired congenital or postoperative residual ventricular septal defects (VSDs). METHODS AND RESULTS: Since 1989, 170 patients (median age, 3.9 years) have undergone catheterization for closure of 1 or more congenital (n=92) or postoperative (n=78) residual VSDs using successive generations of STARFlex-type devices. Outcomes included echocardiographic assessment of residual flow and device position, assessment of VSD shunt/severity, and adverse events. Among 168 patients in whom device implantation was performed, between 1 and 7 devices were placed per patient (median, 1), with multiple devices placed in 40%. There was a significant decrease in left-to-right shunting after device implantation (P<0.001) and significant improvement in VSD size/severity, and device position proved stable. Of 332 adverse events, 39 were related to the device and 261 were related to the catheterization; all but 5 occurred in the periprocedural period. At a median follow-up of 24 months (0 to 154 months), 14 patients had died and 18 had device(s) explanted. CONCLUSIONS: Congenital and postoperative VSD closure using STARFlex-type devices resulted in stable improvement in clinical status and decreased interventricular shunting. Although periprocedural events occurred frequently, late events caused by the device were rare. Transcatheter device closure is an effective management option for patients with complex muscular VSDs that are difficult to approach surgically and for postoperative residual VSDs.


Asunto(s)
Cateterismo Cardíaco , Defectos del Tabique Interventricular/terapia , Prótesis e Implantes , Preescolar , Estudios de Cohortes , Falla de Equipo , Femenino , Cardiopatías Congénitas/cirugía , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/cirugía , Humanos , Lactante , Tablas de Vida , Masculino , Resultado del Tratamiento , Ultrasonografía
17.
J Am Coll Cardiol ; 44(3): 513-9, 2004 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-15358013

RESUMEN

OBJECTIVES: We sought to review and report initial and one-year efficacy and safety results of the multicenter USA Amplatzer ductal occluder (ADO) device trial. BACKGROUND: Transcatheter closure of a moderate to large patent ductus arteriosus (PDA) using conventional techniques is challenging. The ADO can close a PDA up to 12 mm in diameter. METHODS: From September 1999 to June 2002, 484 patients were enrolled in 25 U.S. centers. Forty-five (9%) of 484 patients did not have ADO implantation, because the PDA was too small or because of elevated pulmonary resistance. The median age of the patients at catheterization was 1.8 years (range 0.2 to 70.7 years), and weight was 11 kg (range 4.5 to 164.5 kg). RESULTS: The median PDA minimal diameter was 2.6 mm (range 0.9 to 11.2 mm); 76 (17%) of 439 were larger than 4.0 mm. Median pulmonary artery mean pressure was 20 mm Hg (range 7 to 80 mm Hg). The ADO was implanted successfully in 435 (99%) of 439 patients, with a median fluoroscopy time of 7.1 min (range 2.9 to 138.4 min). Angiographic demonstration of occlusion was seen in 329 (76%) of 435. This increased to 384 (89%) of 433 on post-catheterization day 1, with occlusion documented in 359 (99.7%) of 360 at one year. At the last evaluation in all patients at any time, PDA closure was documented in 428 (98%) of 435 patients. There have been two cases of partial left pulmonary artery occlusion after ADO implantation and no cases of significant aortic obstruction. CONCLUSIONS: Moderate to large PDAs can be effectively and safely closed using the ADO device, with excellent initial and one-year results. This device should obviate the need for multiple coils or surgical intervention for these defects.


Asunto(s)
Oclusión con Balón/métodos , Cateterismo Cardíaco/instrumentación , Conducto Arterioso Permeable/cirugía , Adolescente , Adulto , Anciano , Angiografía , Cateterismo Cardíaco/efectos adversos , Presión Venosa Central , Niño , Preescolar , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/patología , Conducto Arterioso Permeable/fisiopatología , Diseño de Equipo , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Arteria Pulmonar/patología , Arteria Pulmonar/fisiopatología , Instrumentos Quirúrgicos , Resultado del Tratamiento , Estados Unidos
18.
J Thorac Cardiovasc Surg ; 129(3): 559-68, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15746739

RESUMEN

OBJECTIVES: We reviewed our experience with repair of truncus arteriosus to assess the effect of type of right ventricular outflow tract reconstruction on perioperative morbidity, survival, and freedom from catheter-based interventions and reoperation. METHODS: Patients undergoing repair of truncus arteriosus from June 1990 through February 2004 were evaluated on the basis of operative procedure regarding preoperative and postoperative variables, the need for postoperative catheter-based intervention or reoperation, and survival on the basis of univariate, multivariable, and actuarial analyses. RESULTS: Of 54 study patients, 15 (28%) received a valved homograft, and 39 (72%) received a direct connection with a variety of hood materials. Five (9.1%) patients died. Valved homograft recipients were more likely to require reoperation than patients receiving direct connections (40% vs 15%, P = .046); however, valved homograft and direct connection recipients had a similar incidence of the combined end point of reoperation or catheter-based intervention (40.0% vs 37.5%, P = .865). Univariate and multivariable modeling demonstrated use of valved homografts or direct connections with an autologous pericardial hood to be predictive of the need for later catheter-based intervention or reoperation. Actuarial analysis demonstrated a trend toward improved outcomes in the direct connection group and within the direct connection cohort, a statistically significant difference on the basis of hood type. CONCLUSIONS: Although the direct connection technique might not prevent later catheter-based intervention, it does reduce the need for reoperation. Outcomes among direct connection recipients were associated with hood type: polytetrafluoroethylene hoods (W. L. Gore & Associates, Inc, Tempe, Ariz) had the lowest rate of reintervention, and untreated autologous pericardial hoods had the highest rate of reintervention. We report excellent outcomes with primary repair of truncus arteriosus. Where anatomically appropriate, we advocate the direct connection technique.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Tronco Arterial Persistente/cirugía , Puente Cardiopulmonar , Humanos , Hipotermia Inducida , Lactante , Recién Nacido , Arteria Pulmonar/cirugía , Venas Pulmonares/cirugía , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
19.
Expert Rev Med Devices ; 12(6): 653-65, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26513599

RESUMEN

Synthetic conduits and bioprosthetic valves are used in the treatment of patients with congenital heart disease involving the right ventricular outflow tract and pulmonary valve. In-situ time-dependent degradation uniformly results in conduit and valve dysfunction. The abnormal hemodynamics imposed by valve and conduit dysfunction have been linked to exercise intolerance, arrhythmia, right heart failure, and sudden death. Starting in childhood, affected patients are subjected to repeated open-heart surgeries to restore valve function and potentially reduce morbidity and mortality. Percutaneous transcatheter pulmonary valve replacement with the Melody Transcatheter Pulmonary Valve (Medtronic, Inc., Minneapolis, MN) has been performed in ≈8000 patients worldwide. The valve and implant procedure provide a far less invasive means of restoring valve and conduit function and allow patients to forego multiple operations. Recent clinical trials have shown excellent and durable results in terms of valve function, relief of obstruction, and improvement in functional class up to 7 years from implant.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Arteria Pulmonar/fisiopatología , Válvula Pulmonar/fisiopatología , Disfunción Ventricular Derecha/cirugía , Ensayos Clínicos como Asunto , Implantación de Prótesis de Válvulas Cardíacas/economía , Implantación de Prótesis de Válvulas Cardíacas/legislación & jurisprudencia , Humanos , Complicaciones Posoperatorias/etiología
20.
Ann Thorac Surg ; 100(3): 996-1002; discussion 1002-3, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26190388

RESUMEN

BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review of databases from 3 prospective Melody TPV (Medtronic Inc, Minneapolis, MN) trials. RESULTS: Among 358 patients who were catheterized with the intent to implant a Melody TPV for RVOT conduit stenosis or regurgitation (PR) as part of 3 prospective multicenter studies, 67 (19%) had a prior Ross procedure. Of these, 56 (84%) received a Melody valve; in 5 of the 11 patients who did not, the implant was aborted due to concern for coronary artery compression, and 1 implanted patient required emergent surgery for left coronary compression. The RVOT gradient decreased from a median 38 mm Hg to 13.5 mm Hg (p < 0.001). There was no or trivial PR in all but 4 patients, in whom it was mild. At a median follow-up of 4.0 years, 1 patient died from sepsis. Twelve patients underwent 14 transcatheter (n = 8) or surgical (n = 6) TPV reinterventions for obstruction with stent fracture (n = 9), endocarditis with conduit obstruction (n = 3), or reoperation (n = 2). Freedom from TPV explant was 89% ± 5% at 4 years. Among patients who did not undergo reintervention for obstruction, there was no change in RVOT gradient over time, and all but 1 patient had mild or less PR at last follow-up. CONCLUSIONS: The TPVR with the Melody valve provides acceptable early outcomes and durable valve function in the majority of Ross patients. Recurrent RVOT obstruction associated with stent fracture was the main reason for reintervention. Coronary compression is not uncommon in Ross patients and should be assessed prior to TPVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/cirugía , Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Adulto , Cateterismo Cardíaco , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA