Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 47(5): 614-625, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38558218

RESUMEN

INTRODUCTION: The use of esophageal temperature monitoring (ETM) for the prevention of esophageal injury during atrial fibrillation (AF) ablation is often advocated. However, evidence supporting its use is scarce and controversial. We therefore aimed to review the evidence assessing the efficacy of ETM for the prevention of esophageal injury. METHODS: We performed a meta-analysis and systematic review of the available literature from inception to December 31, 2022. All studies comparing the use of ETM, versus no ETM, during radiofrequency (RF) AF ablation and which reported the incidence of endoscopically detected esophageal lesions (EDELs) were included. RESULTS: Eleven studies with a total of 1112 patients undergoing RF AF ablation were identified. Of those patients, 627 were assigned to ETM (56%). The overall incidence of EDELs was 9.8%. The use of ETM during AF ablation was associated with a non significant increase in the incidence of EDELs (12.3% with ETM, vs. 6.6 % without ETM, odds ratio, 1.44, 95%CI, 0.49, 4.22, p = .51, I2 = 72%). The use of ETM was associated with a significant increase in the energy delivered specifically on the posterior wall compared to patients without ETM (mean power difference: 5.13 Watts, 95% CI, 1.52, 8.74, p = .005). CONCLUSIONS: The use of ETM does not reduce the incidence of EDELs during RF AF ablation. The higher energy delivered on the posterior wall is likely attributable to a false sense of safety that may explain the lack of benefit of ETM. Further randomized controlled trials are needed to provide conclusive results.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Esófago , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/prevención & control , Esófago/lesiones , Temperatura Corporal , Monitoreo Intraoperatorio/métodos , Complicaciones Intraoperatorias/prevención & control
2.
Europace ; 25(10)2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37695314

RESUMEN

AIMS: Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR. METHODS AND RESULTS: From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR. CONCLUSION: STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude.

3.
Catheter Cardiovasc Interv ; 96(2): 424-431, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31642609

RESUMEN

BACKGROUND: Interatrial septum (IAS) dissection due to transseptal puncture (TSP) is a rare, underreported complication of the procedure. Data on the mechanism, diagnosis, and management of this complication are lacking. METHODS: We conducted a systematic review of all reported cases of IAS dissection with or without associated LA hematoma due to TSP, by thoroughly searching MEDLINE and EMBASE through May 2019. RESULTS: After screening of n = 882 studies, eight studies with a total of 19 patients addressed the complication of IAS dissection and/or LA hematoma secondary to TSP. Median age was 63 years with a 1:1 male to female ratio. Ablation of atrial fibrillation was the most frequently reported procedure (84%). Diagnosis was established using fluoroscopy with contrast injection (58%), TEE (32%) or intracardiac echocardiography (5%). The mechanism identified involved puncture of the septum secundum portion of the IAS, leading to transient needle passage into the extracardiac space. In the majority of patients, the hematoma remained localized in the IAS and management was conservative with progressive resolution of the hematoma during follow-up (95%). Two patients (11%) required further intervention by either pericardiocentesis or surgical drainage due to hemodynamic instability. CONCLUSIONS: IAS dissection with or without hematoma after TSP remains an underdiagnosed entity. The main mechanism involves lesion to the septum secundum portion of the IAS, resulting in needle passage into the extracardiac space and local bleeding. Although conservative management may be sufficient in the majority of cases, interventional cardiologists should be familiar with this complication and its diagnosis.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Lesiones Cardíacas/etiología , Hematoma/etiología , Anciano , Femenino , Atrios Cardíacos/diagnóstico por imagen , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/terapia , Tabiques Cardíacos , Hematoma/diagnóstico por imagen , Hematoma/terapia , Humanos , Masculino , Persona de Mediana Edad , Punciones/efectos adversos , Medición de Riesgo , Factores de Riesgo
4.
Rev Med Suisse ; 16(696): 1148-1152, 2020 Jun 03.
Artículo en Francés | MEDLINE | ID: mdl-32496703

RESUMEN

The gene SCN5A encodes the cardiac sodium channel which, through the conduction of Na+ current into the cell, generates the fast upstroke of the action potential of cardiomyocytes. Pathogenic variants of SCN5A have been causally associated to several hereditary cardiac diseases including, among others, Brugada syndrome, congenital long QT syndrome and sinus node dysfunction. Recently, overlap syndromes have been described that are characterized by the simultaneous expression of mixed clinical phenotypes among two or more hereditary cardiac diseases associated to the gene SCN5A (HCD-SCN5A). For this reason, it is time to rethink about HCD-SCN5A as different expressions of the same complex spectrum encompassing multiple clinical phenotypes with pronounced overlaps instead of as distinct clinical entities.


Le gène SCN5A code pour le canal sodique cardiaque qui est responsable de la pente de dépolarisation rapide du potentiel d'action. Plusieurs cardiopathies héréditaires (CH) ont été associées à des variants pathogènes du gène SCN5A incluant, entre autres, le syndrome de Brugada, le syndrome du QT long congénital et la dysfonction sinusale. Récemment, des syndromes de chevauchement ont été également décrits, s'exprimant, chez un même patient, par un phénotype clinique mixte comprenant une combinaison des manifestations rapportées ci-dessus. Dans ce contexte, nous devrions donc reconsidérer cliniquement les CH impliquant le gène SCN5A comme des expressions différentes d'un même éventail de phénotypes cliniques avec chevauchements marqués plutôt que comme des entités cliniques distinctes et isolées.


Asunto(s)
Síndrome de Brugada , Síndrome de QT Prolongado , Síndrome del Seno Enfermo , Síndrome de Brugada/genética , Humanos , Síndrome de QT Prolongado/genética , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/genética , Fenotipo , Síndrome del Seno Enfermo/genética , Síndrome
5.
Rev Med Suisse ; 15(652): 1082-1086, 2019 May 22.
Artículo en Francés | MEDLINE | ID: mdl-31116523

RESUMEN

Stereotactic body radiotherapy (SBRT) is routinely used in oncology to treat non-invasively solid tumors with high precision and efficacy. Recently, this technology has been evaluated in the treatment of ventricular tachycardia (VT). This article presents the basic underlying principles, proofs of concept and main results of clinical studies that used SBRT for the treatment of VT.


La radiothérapie stéréotaxique (SBRT) est une technologie couramment utilisée en oncologie pour traiter de façon non invasive les tumeurs solides avec précision et efficacité. Récemment, cette technologie a été évaluée dans le traitement des tachycardies ventriculaires (TV). Cet article présente les principes de base sous-jacents, le concept ainsi que les résultats des premières études cliniques ayant traité avec succès des patients souffrant de TV avec la SBRT.


Asunto(s)
Radiocirugia , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/radioterapia
7.
Europace ; 18(10): 1587-1592, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26705564

RESUMEN

AIMS: The early repolarization pattern (ERP) has been shown to be associated with arrhythmias in patients with short QT syndrome, Brugada syndrome, and ischaemic heart disease. Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmia syndrome and related to malignant ventricular tachyarrhythmias in a structurally normal heart. The aim of this study was to evaluate the prevalence of ERP and clinical events in patients with CPVT. METHODS AND RESULTS: Digitalized resting 12-lead ECGs of patients were analysed for ERP and for repolarization markers (QT and Tpeak-Tend interval). The ERP was diagnosed as 'notching' or 'slurring' at the terminal portion of QRS with ≥0.1 mV elevation in at least two consecutive inferior (II, III, aVF) and/or lateral leads (V4-V6, I, aVL). Among 51 CPVT patients (mean age 36 ± 15 years, 11 males), the ERP was present in 23 (45%): strictly in the inferior leads in 9 (18%) patients, in the lateral leads in 9 (18%) patients, and in infero-lateral leads in 5 (10%) patients. All patients with ERP were symptomatic at presentation (23 of 23 patients with ERP vs. 19 of 28 patients without ERP, P = 0.003). Syncope was also more frequent in patients with ERP (18 of 23 patients with ERP vs. 11 of 28 patients without ERP, P = 0.005). CONCLUSION: A pathologic ERP is present in an unexpected large proportion (45%) of patients and is associated with an increased frequency of syncope. In patients with unexplained syncope and ERP at baseline, exercise testing should be performed to detect CPVT.


Asunto(s)
Sistema de Conducción Cardíaco/fisiopatología , Síncope/epidemiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Adolescente , Antagonistas de Receptores Adrenérgicos beta 1/uso terapéutico , Adulto , Anciano , Niño , Desfibriladores Implantables , Electrocardiografía , Femenino , Pruebas Genéticas , Alemania , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Síncope/etiología , Taquicardia Ventricular/terapia , Adulto Joven
9.
J Cardiovasc Electrophysiol ; 25(3): 266-70, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24172190

RESUMEN

BACKGROUND: Thrombi form mainly in the left rather than the right atria of patients with atrial fibrillation (AF), the reason of this predilection being unknown. OBJECTIVE: The purpose of this study was to investigate whether atrial-specific differences in endothelial damage, leukocyte activation, platelet stimulation, and tissue factor activity occur in patients with AF. METHODS: Twenty-two patients (16 men, 6 women; age 56 ± 8 years; 16 paroxysmal AF, 6 persistent AF) with AF undergoing pulmonary vein isolation were investigated. Blood samples from the left and the right atrium were obtained at the start of the procedure. Microparticles (MPs) released by apoptotic/stimulated cells were measured by capture assays. Their procoagulant abilities were quantified by functional prothrombinase and tissue factor assays and their cellular origin were determined (endothelium, platelet, leukocyte). Platelet reactivity was evaluated by whole blood flow cytometry for expression of platelet P-selectin (CD62P), active glycoprotein IIb/IIIa receptor (PAC-1). Platelet aggregation was evaluated using ADP, TRAP and collagen-induced whole blood aggregometry. RESULTS: There were no atrial-specific differences in the levels of total procoagulant MPs, leukocyte-derived-MPs or platelet-derived MPs. Conversely, endothelial-derived MPs and tissue factor activity and collagen-induced platelet aggregation were slightly elevated in the right atrium (P < 0.05). CONCLUSIONS: Our data show no evidence for increased thrombogenic status in the left atrium that would account for its greater propensity for thrombus formation in patients with AF.


Asunto(s)
Fibrilación Atrial/diagnóstico , Endotelio Vascular/patología , Atrios Cardíacos/patología , Activación Plaquetaria/fisiología , Trombosis/diagnóstico , Fibrilación Atrial/sangre , Micropartículas Derivadas de Células/metabolismo , Micropartículas Derivadas de Células/patología , Endotelio Vascular/metabolismo , Femenino , Atrios Cardíacos/metabolismo , Humanos , Leucocitos/metabolismo , Leucocitos/patología , Masculino , Persona de Mediana Edad , Tromboplastina/metabolismo , Trombosis/sangre
10.
Physiol Meas ; 45(2)2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38266291

RESUMEN

Objective.Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date.Approach. ThePPG-beatsopen-source framework, developed by Charlton and colleagues, evaluates the performance of the beat detectors namedQPPG,MSPTDandABDamong others. We applied thePPG-beatsframework on two newly acquired datasets, one containing seven different types of cardiac arrhythmia in hospital settings, and another dataset including two cardiac arrhythmias in ambulatory settings.Main Results. In a clinical setting, theQPPGbeat detector performed best on atrial fibrillation (with a medianF1score of 94.4%), atrial flutter (95.2%), atrial tachycardia (87.0%), sinus rhythm (97.7%), ventricular tachycardia (83.9%) and was ranked 2nd for bigeminy (75.7%) behindABDdetector (76.1%). In an ambulatory setting, theMSPTDbeat detector performed best on normal sinus rhythm (94.6%), and theQPPGdetector on atrial fibrillation (91.6%) and bigeminy (80.0%).Significance. Overall, the PPG beat detectorsQPPG,MSPTDandABDconsistently achieved higher performances than other detectors. However, the detection of beats from wrist-PPG signals is compromised in presence of bigeminy or ventricular tachycardia.


Asunto(s)
Fibrilación Atrial , Taquicardia Ventricular , Humanos , Frecuencia Cardíaca , Fibrilación Atrial/diagnóstico , Fotopletismografía/métodos , Benchmarking , Taquicardia Ventricular/diagnóstico , Algoritmos , Electrocardiografía/métodos
11.
Front Cardiovasc Med ; 10: 1213165, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547255

RESUMEN

Background: Cardiac sarcoidosis is associated with heart failure, conduction abnormalities, and life-threatening arrhythmias including ventricular tachycardia (VT). Radiotherapy has been suggested as a treatment for extra-cardiac sarcoidosis in patients refractory to immunomodulatory treatment. Methods: The effectiveness and safety of low-dose whole-heart radiotherapy for therapy refractory cardiac sarcoidosis were evaluated in a pre- and post-intervention case report comparing the 54 months before and after treatment. Immunomodulatory low-dose whole-heart irradiation as sarcoidosis treatment consisted of a 2 × 2 Gy scheme. Additionally, high-dose single-fraction stereotactic arrhythmia radioablation of 1 × 20 Gy was applied to the pro-arrhythmic region to manage the ventricular tachycardia episodes. Cardiac sarcoidosis disease activity was measured by hypermetabolic areas on repeated fluorodeoxyglucose ([18F]FDG)-PET/computed tomography (CT) scans and by evaluating changes in ventricular tachycardia episodes before and after treatment. Results: One patient with therapy refractory progressive cardiac sarcoidosis and recurrent ventricular tachycardia was treated. The cardiac sarcoidosis disease activity showed a durable regression of inflammatory disease activity from 3 months onwards. The [18F]FDG-PET/CT scan at 54 months did not show any signs of active cardiac sarcoidosis, and a state of remission was achieved. The number of sustained VT episodes was reduced by 95%. We observed that the development of moderate aortic valve regurgitation was likely irradiation-related. No other irradiation-related adverse events occurred, and the left ventricular ejection fraction remained stable. Conclusion: We report here for the first time on the beneficial and lasting effects of combined immunomodulatory low-dose whole-heart radiotherapy and high-dose stereotactic arrhythmia radioablation in a patient with therapy refractory cardiac sarcoidosis and recurrent VT.

12.
Front Cardiovasc Med ; 10: 1267800, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37799779

RESUMEN

Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02-0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52-1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51-1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.

13.
Radiother Oncol ; 189: 109910, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37709052

RESUMEN

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) appears to be beneficial in selected patients with therapy-refractory ventricular tachycardia (VT). However, high-dose radiotherapy used for STAR-treatment may affect functioning of the patients' implantable cardioverter defibrillator (ICD) by direct effects of radiation on ICD components or cardiac tissue. Currently, the effect of STAR on ICD functioning remains unknown. METHODS: A retrospective pre-post multicenter study evaluating ICD functioning in the 12-month before and after STAR was performed. Patients with (non)ischemic cardiomyopathies with therapy-refractory VT and ICD who underwent STAR were included and the occurrence of ICD-related adverse events was collected. Evaluated ICD parameters included sensing, capture threshold and impedance. A linear mixed-effects model was used to investigate the association between STAR, radiotherapy dose and changes in lead parameters over time. RESULTS: In total, 43 patients (88% male) were included in this study. All patients had an ICD with an additional right atrial lead in 34 (79%) and a ventricular lead in 17 (40%) patients. Median ICD-generator dose was 0.1 Gy and lead tip dose ranged from 0-32 Gy. In one patient (2%), a reset occurred during treatment, but otherwise, STAR and radiotherapy dose were not associated with clinically relevant alterations in ICD leads parameters. CONCLUSIONS: STAR treatment did not result in major ICD malfunction. Only one radiotherapy related adverse event occurred during the study follow-up without patient harm. No clinically relevant alterations in ICD functioning were observed after STAR in any of the leads. With the reported doses STAR appears to be safe.


Asunto(s)
Desfibriladores Implantables , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Femenino , Desfibriladores Implantables/efectos adversos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Estudios Retrospectivos , Arritmias Cardíacas/etiología , Isquemia Miocárdica/etiología , Resultado del Tratamiento
14.
Front Cardiovasc Med ; 9: 783576, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35282352

RESUMEN

Over the last decades, the implementation of new technology in cardiac pacemakers and defibrillators as well as the increasing life expectancy have been associated with a higher incidence of transvenous lead complications over time. Variable degrees of venous stenosis at the level of the subclavian vein, the innominate trunk and the superior vena cava are reported in up to 50% of implanted patients. Importantly, the number of implanted leads seems to be the main risk factor for such complications. Extraction of abandoned or dysfunctional leads is a potential solution to overcome venous stenosis in case of device upgrades requiring additional leads, but also, in addition to venous angioplasty and stenting, to reduce symptoms related to the venous stenosis itself, i.e., the superior vena cava syndrome. This review explores the role of transvenous lead extraction procedures as therapeutical option in case of central venous disorders related to transvenous cardiac leads. We also describe the different extraction techniques available and other clinical indications for lead extractions such as lead infections. Finally, we discuss the alternative therapeutic options for cardiac stimulation or defibrillation in case of chronic venous occlusions that preclude the implant of conventional transvenous cardiac devices.

16.
Front Cardiovasc Med ; 9: 910693, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36148076

RESUMEN

Background: Studies suggest that performing an electrophysiological study (EPS) may be useful to identify patients with new-onset left bundle branch block (LBBB) post-TAVR at risk of atrioventricular block. However, tools to optimize the yield of such strategy are needed. We therefore aimed to investigate whether 12-lead ECG changes post-TAVR may help identify patients with abnormal EPS findings. Materials and methods: Consecutive patients with new-onset LBBB post-TAVR who underwent EPS were included. PR and QRS intervals were measured on 12-lead ECG pre-TAVR and during EPS. Abnormal EPS was defined as an HV interval > 55 ms. Results: Among 61 patients, 28 (46%) had an HV interval > 55 ms after TAVR. Post-TAVR PR interval and ΔPR (PR-post-pre-TAVR) were significantly longer in patients with prolonged HV (PR: 188 ± 38 vs. 228 ± 34 ms, p < 0.001, ΔPR: 10 ± 30 vs. 34 ± 23 ms, p = 0.001), while no difference was found in QRS duration. PR and ΔPR intervals both effectively discriminated patients with HV > 55 ms (AUC = 0.804 and 0.769, respectively; p < 0.001). A PR > 200 ms identified patients with abnormal EPS results with a sensitivity of 89% and a negative predictive value (NPV) of 88%. ΔPR ≥ 20 ms alone provided a somewhat lower sensitivity (64%) but combining both criteria (i.e., PR > 200 ms or ΔPR ≥ 20 ms) identified almost every patients with abnormal HV (sensitivity = 96%, NPV = 95%). Selecting EPS candidate based on both criteria would avoid 1/3 of exams. Conclusion: PR interval assessment may be useful to select patients with new-onset LBBB after TAVR who may benefit most from an EPS. In patients with PR ≤ 200 ms and ΔPR < 20 ms the likelihood of abnormal EPS is very low independently of QRS changes.

17.
Eur Heart J Case Rep ; 5(11): ytab418, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34805739

RESUMEN

BACKGROUND: The diagnosis of inflammatory cardiomyopathy remains challenging in cases presenting with arrhythmia as sole manifestation. An early diagnosis is critical as it may prevent life-threatening complications such as sudden cardiac death and atrioventricular block (AVB). The diagnostic workup of suspected cases includes multimodality imaging that requires an adequate interpretation in order to limit the risk of overdiagnosis. CASE SUMMARY: Herein, we report three cases presenting with various new-onset arrhythmias. The first patient was admitted for a third-degree AVB. The second patient suffered from a supraventricular tachycardia which degenerated into ventricular fibrillation. The third case was investigated for symptomatic premature ventricular complexes. No apparent heart disease was observed on standard exams (clinical, biological examinations, and echocardiography). However, cardiac magnetic resonance imaging (MRI) and nuclear imaging (68Ga-DOTATOC and/or 18F-FDG PET/CT) suggested an inflammatory substrate that seemed to correlate with the arrhythmic phenotype. Cardiac inflammation disappeared on immunotherapy for the first case and spontaneously for the third case. DISCUSSION: These cases emphasize the incremental diagnostic yield of multimodality imaging to highlight myocardial inflammation. Nuclear imaging modalities may complement MRI by enabling the detection of active inflammation. The 18F-FDG PET/CT is well established for the diagnosis of cardiac sarcoidosis but its role remains to be clarified for the diagnosis of myocarditis. An alternative radiotracer, 68Ga-DOTATOC, appears promising by overcoming the main limitation of 18F-FDG but its specificity is not yet well established. The role of functional investigations is discussed as well as the benefit of immunosuppressive treatments.

18.
J Clin Med ; 10(14)2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-34300187

RESUMEN

The Swiss Ablation Registry provides a national database for electrophysiologic studies and catheter ablations. We analyzed the database to provide an in-depth look at changing trends over the last 20 years. During the study period a total of 78622 catheter ablations (age 61.0 ± 1.2 years; 63.7% male) were performed in 29 centers. The number of ablations increased by approximately ten-fold in 20 years. Ablation for atrial fibrillation (AF) was the main driver behind this increase, with more than hundred-fold (39.7% of all ablations in 2019). Atrioventricular-nodal-reentrant-tachycardia (AVNRT) and accessory pathways, being the main indications for ablation in 2000 (44.1%/25.1%, respectively), made up of only a small proportion (15.2%/3.5%,) respectively in 2019. Fluoroscopy, ablation, and procedure durations were reduced for all ablations over time. The highest repeat ablations were performed for ventricular tachycardia and AF (24.4%/24.3%). The majority of ablations (63.0%) are currently performed in private hospitals and non-university public hospitals whereas university hospitals had dominated (82.4%) at the turn of the century. A pronounced increase in the number of catheter ablations in Switzerland was accompanied by a marked decrease in fluoroscopy, ablation, and procedure durations. We observed a shift toward more complex procedures in older patients with comorbidities.

19.
J Clin Med ; 10(17)2021 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-34501258

RESUMEN

BACKGROUND: The wearable cardioverter defibrillator (WCD) uses surface electrodes to detect arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. OBJECTIVE: The aim of this study is to assess the alarm burden in patients and its impact on clinical outcomes. METHODS: Patients from the nationwide Swiss WCD Registry were included. Clinical characteristics and data were obtained from the WCDs. Arrhythmia recordings ≥30 s in length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia (SVT) or artefact. RESULTS: A total of 10653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0 ± 1.6 months. Episode duration was 30 s or more in 2996 alarms (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) SVT). Two-hundred and seven patients (45%) had three or more alarms per month. Obesity was significantly associated with three or more alarms per month (p = 0.01, 27.7% vs. 15.9%). High alarm burden was not associated with a lower average daily wear time (20.8 h vs. 20.7 h, p = 0.785) or a decreased implantable cardioverter defibrillator implantation rate after stopping WCD use (48% vs. 47.3%, p = 0.156). CONCLUSIONS: In patients using WCDs, alarms emitted by the device and impending inappropriate shocks were frequent and most commonly caused by artefacts. A high alarm burden was associated with obesity but did not lead to a decreased adherence.

20.
JACC Case Rep ; 2(6): 973-978, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34317394

RESUMEN

Ethanol infusion has been used for the treatment of ventricular arrhythmia. We describe a case of ethanol infusion through the coronary sinus venous network to treat refractory epicardial premature ventricular complexes. The premature ventricular complexes were initially successfully suppressed but recurred after resolution of the myocardial edema. (Level of Difficulty: Intermediate.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA