Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur Radiol ; 26(10): 3752-9, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26792428

RESUMEN

OBJECTIVES: This work evaluates rapid magnetic resonance projection hydrography (PH) based amniotic fluid volume (AFV) estimates against established routine ultrasound single deepest vertical pocket (SDVP) and amniotic fluid index (AFI) measurements, in utero at 28-32 weeks gestation. Manual multi-section planimetry (MSP) based measurement of AFV is used as a proxy reference standard. METHODS: Thirty-five women with a healthy singleton pregnancy (20-41 years) attending routine antenatal ultrasound were recruited. SDVP and AFI were measured using ultrasound, with same day MRI assessing AFV with PH and MSP. The relationships between the respective techniques were assessed using linear regression analysis and Bland-Altman method comparison statistics. RESULTS: When comparing estimated AFV, a highly significant relationship was observed between PH and the reference standard MSP (R(2) = 0.802, p < 0.001). For the US measurements, SDVP measurement related most closely to amniotic fluid volume, (R(2) = 0.470, p < 0.001), with AFI demonstrating a weaker relationship (R(2) = 0.208, p = 0.007). CONCLUSION: This study shows that rapid MRI based PH measurement is a better predictor of AFV, relating more closely to our proxy standard than established US techniques. Although larger validation studies across a range of gestational ages are required this approach could form part of MR fetal assessment, particularly where poly- or oligohydramnios is suspected. KEY POINTS: • MR projection hydrography can be used to estimate amniotic fluid volume. • MR projection hydrography relies on the T2w signal from amniotic fluid. • Amniotic fluid volume (AFV) is more accurately assessed than with ultrasound.


Asunto(s)
Líquido Amniótico/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Diagnóstico Prenatal/métodos , Adulto , Femenino , Edad Gestacional , Humanos , Variaciones Dependientes del Observador , Embarazo , Ultrasonografía Prenatal , Adulto Joven
2.
Clin Radiol ; 68(5): 521-8, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23218593

RESUMEN

The purpose of this article is to review the underlying causes of secondary pneumothoraces as observed on multidetector computed tomography (MDCT). Using examples from our institutional experience, we shall illustrate important diagnostic features to indicate the underlying lung disease. Understanding the varied range of conditions is important for accurate diagnosis and facilitation of patient management.


Asunto(s)
Enfermedades Pulmonares/complicaciones , Enfermedades Pulmonares/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Neumotórax/diagnóstico por imagen , Neumotórax/etiología , Humanos
3.
Semin Vasc Surg ; 29(3): 126-134, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27989318

RESUMEN

The Nellix stent graft has novel features that influence interpretation of imaging follow-up, in particular, the use of endobags that seal the aneurysm sac. The polymer within the endobags contains a small amount of contrast medium, which causes a predictable temporal change in appearances. Understanding of these features allows correct image evaluation. In this article, we review the appearance of Nellix on computed tomography, ultrasound, magnetic resonance imaging, and plain radiography. We describe the special considerations that are important to consider when reviewing imaging, including endobag position and seal, endobag configuration, endobag and polymer maturation, and endobag gas. Detection of complications is discussed, with suggestion of a follow-up protocol based on the authors' experience.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Diagnóstico por Imagen/métodos , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/instrumentación , Stents , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Endofuga/etiología , Endofuga/prevención & control , Procedimientos Endovasculares/efectos adversos , Humanos , Angiografía por Resonancia Magnética , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento , Ultrasonografía Doppler en Color
4.
Placenta ; 43: 35-40, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27324097

RESUMEN

OBJECTIVE: The aim of this work was to evaluate whether the uterine arteries (UtA) could be identified and their flow profiles measured during a fetal MRI examination. A comparison was performed against same day sonographic Doppler assessment. METHODS: 35 normal, healthy, singleton pregnancies at 28-32 weeks gestation underwent routine Doppler examination, followed by MRI examination. The resistivity index (RI) and pulsatility index (PI) of the left and right UtA were measured using phase contrast MRI. Bland Altman statistics were used to compare MRI and ultrasound results. RESULTS: Sixty-nine comparable vessels were analysed. Six vessels were excluded due to artefact or technical error. Bland-Altman analysis demonstrated the ultrasound indices were comparable, although systematically lower than the MRI indices; Right UtA RI bias -0.03 (95% limits of agreement (LOA) -0.27 to +0.20), and left UtA RI bias -0.06 (95% LOA -0.26 to +0.14); Right UtA PI bias -0.06 (95% LOA -0.50 to +0.38), Left UtA PI bias -0.11 (95% LOA -0.54 to +0.32). The inter-rater agreement for the MRI derived PI and RI analysis was good. CONCLUSION: This study demonstrates that in the majority of early third trimester pregnancies, the uterine arteries can be identified, and their flow profiles measured using MRI, and that the derived PI and RI values are comparable with Doppler ultrasound values.


Asunto(s)
Imagen por Resonancia Magnética , Tercer Trimestre del Embarazo/fisiología , Ultrasonografía Doppler , Arteria Uterina/diagnóstico por imagen , Resistencia Vascular/fisiología , Femenino , Humanos , Embarazo , Flujo Pulsátil/fisiología , Arteria Uterina/fisiología
6.
Protein Expr Purif ; 2(2-3): 151-7, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1821784

RESUMEN

We used site-directed mutagenesis to introduce both a NdeI restriction endonuclease site and an initiator codon at the junction of the leader and structural gene sequences of the metallo-beta-lactamase of Bacillus cereus 5/B/6. This construct allowed us to clone just the beta-lactamase structural gene sequence into an Escherichia coli expression vector. E. coli cells were transformed with the recombinant plasmid, the B. cereus beta-lactamase was expressed, and these E. coli cells were disrupted by sonic oscillation. When the resultant suspensions were clarified by ultracentrifugation, the B. cereus beta-lactamase represented 15% of the total protein in the supernatant. Subsequent gel filtration and ion-exchange chromatography allowed the first reported purification to homogeneity of the B. cereus beta-lactamase from E. coli with an 87% recovery and an overall yield of 17 mg of enzyme per liter of cell culture. The electrophoretic mobilities of the enzyme expressed in and purified from E. coli and the enzyme purified directly from B. cereus were identical in both native and sodium dodecyl sulfate gel electrophoreses. As with the B. cereus enzyme, Km and Vmax (using cephalosporin C as substrate) for the enzyme purified from E. coli were 0.39 mM and 1333 units/mg protein, respectively. Likewise, the Co(II)-reconstituted enzyme purified from E. coli, which retained 29% of the activity of the Zn(II) enzyme, had electronic absorption spectra with maxima at 347, 551, 617, and 646 nm with extinction coefficients of 900, 250, 173, and 150 M-1 cm-1, respectively.


Asunto(s)
Bacillus cereus/enzimología , Bacillus cereus/genética , beta-Lactamasas/genética , beta-Lactamasas/aislamiento & purificación , Secuencia de Bases , Cromatografía en Gel , Cromatografía por Intercambio Iónico , Clonación Molecular , ADN Bacteriano/genética , Escherichia coli/genética , Expresión Génica , Genes Bacterianos , Cinética , Datos de Secuencia Molecular , Mutagénesis Sitio-Dirigida , beta-Lactamasas/metabolismo
7.
Arch Biochem Biophys ; 291(1): 195-9, 1991 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-1929431

RESUMEN

Recent preparations of nitrite reductase do not display the heterodimeric quaternary structure obtained previously (total molecular weight 85,000; subunit molecular weights 24,000 and 61,000), but rather yield only the 61,000 molecular weight subunit, even when buffers containing the protease inhibitor phenylmethylsulfonyl fluoride are used. Nevertheless, such preparations retain the high ratio of ferredoxin-linked to methyl viologen-linked enzyme activity which has been previously taken as a characteristic of only the heterodimeric form. These preparations display a siroheme prosthetic group to protein ratio of 1.1. When nitrite reductase samples are frozen during the purification scheme, even though the ferredoxin-linked specific activity does not significantly decrease, enzyme activity-stained native gel electrophoresis of the subsequently purified protein reveals that gels with several bands of activity can be obtained. Further evidence of protein heterogeneity in these preparations comes from N-terminal amino acid analysis which reveals that even nonfrozen preparations contain two major peptides with valine and cysteine as the N-termini. Formation of complexes of purified nitrite reductase with ferredoxin resulted in siroheme difference electronic spectra which resembled those observed previously for monomeric preparations. However, the siroheme midpoint potential of recent preparations of nitrite reductase (-287 mV) is close to that of the heterodimeric preparations. Ultrafiltration studies of crude extracts of the enzyme indicate that, at least at certain stages of the preparation, higher molecular weight forms of the enzyme may exist. We conclude that the 24,000 molecular weight polypeptide is a contaminant and that the heterodimeric quaternary structure model for spinach nitrite reductase is incorrect. Furthermore, the monomeric preparations we do obtain display both significant protein heterogeneity and facile loss of siroheme upon gel filtration.


Asunto(s)
Nitrito Reductasas/metabolismo , Cromatografía en Gel , Electroforesis en Gel de Poliacrilamida , Hemo/análogos & derivados , Hemo/análisis , Nitrito Reductasas/aislamiento & purificación , Proteínas de Plantas/análisis , Plantas/enzimología , Ultrafiltración
8.
Int J Pharm Compd ; 2(6): 427, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-23988316
9.
J Am Pharm Assoc ; 16(4): 200, 213, 1976 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-1270732
SELECCIÓN DE REFERENCIAS