Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Catheter Cardiovasc Interv ; 102(1): 155-158, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37210620

RESUMEN

A 70-year-old man with history of transcatheter aortic valve-in-valve implantation was admitted because of suspected infective endocarditis (IE). Transesophageal echocardiogram did not reveal any vegetations, as the metallic stent frames caused significant artifacts. Position emission tomography was also negative. Intracardiac echocardiogram (ICE) was performed retrogradely through the ascending aorta, which showed clear vegetations over the stent frame of the transcatheter heart valve. Endocarditis after transcatheter aortic valve implantation was not uncommon. With increasing use of valve-in-valve procedures, echocardiographic diagnosis of IE would be more challenging. This case demonstrated the advantage of ICE over conventional echocardiography in visualizing the neo-aortic valve complex for diagnosing IE.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Infecciones Relacionadas con Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/terapia , Resultado del Tratamiento , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Endocarditis/etiología , Endocarditis/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Ecocardiografía/efectos adversos
2.
Heart Lung Circ ; 31(11): e140-e142, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36055925

RESUMEN

A 68-year old lady present with left ventricular free wall rupture and cardiac arrest post-myocardial infarction. This article illustrates a strategy combining pericardiocentesis with autologous transfusion together with VA-ECMO as a bridge to definitive surgical repair.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Rotura Cardíaca Posinfarto , Rotura Cardíaca , Femenino , Humanos , Anciano , Pericardiocentesis , Rotura Cardíaca Posinfarto/cirugía , Transfusión de Sangre Autóloga , Rotura Cardíaca/cirugía
3.
J Invasive Cardiol ; 2024 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-38814905

RESUMEN

A 63-year-old man presented with delayed inferior ST-elevation myocardial infarction complicated with ventricular septal rupture (VSR). He developed cardiogenic shock and respiratory failure requiring intubation and Impella (Abiomed) support.

4.
Int J Cardiol ; 418: 132614, 2024 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-39395724

RESUMEN

BACKGROUND: Patient-specific 3-dimensional (3D) computational modelling offers a tailored approach with promising results, but experience using digital-twin fusion on real-time fluoroscopy to guide left atrial appendage closure (LAAC) is unreported. OBJECTIVES: To assess whether LAAC guided by fusion of a 3D computational model on real-time fluoroscopy is safe and effective. METHODS: We included retrospectively through a multicenter registry all consecutive patients with non-valvular atrial fibrillation (AF) who underwent LAAC guided by artificial intelligence (AI)-enabled computer simulations (FEops, Gent, Belgium) fusion with real-time fluoroscopy. Operators selected the appropriate device size and position in relation to the LAA using FEops HEARTguide™, and a digital twin was provided for image fusion. The primary efficacy endpoint was successful LAAC with the use of a single device, without moderate or greater peri-device leak and/or device related thrombus (DRT) on follow-up imaging. The primary safety endpoint was a composite of major procedural complications including tamponade, stroke, systemic embolism, major bleeding, and device embolization. RESULTS: A total of 106 patients underwent LAAC with an Amulet™ or Watchman FLX™ device using CT-model-fluoroscopy fusion imaging. Device implantation was successful in 100 % of cases. The primary efficacy endpoint was met in 82 patients (89 %). A single-device SINGLE-deployment LAAC procedure was observed in 49 cases (46 %). The primary safety endpoint occurred in 2 patients (1.9 %). After a median follow-up of 405 days, two patients suffered an ischemic stroke and four expired. CONCLUSIONS: Fusion of a CT-based 3D computational model on real-time fluoroscopy is a safe and effective approach that may optimize transcatheter LAAC outcomes.

5.
ESC Heart Fail ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38982624

RESUMEN

AIMS: Currently, there is limited data on prognostic indicators after insertion of percutaneous ventricular assist device (PVAD) in the treatment of cardiogenic shock (CS). This study evaluated the prognostic role of cardiac power output (CPO) ratio, defined as CPO at 24 h divided by early CPO (30 min to 2 h), in CS patients after PVAD. METHODS AND RESULTS: Consecutive CS patients from the QEH-PVAD Registry were followed up for survival at 90 days after PVAD. Among 121 consecutive patients, 98 underwent right heart catheterization after PVAD, with CPO ratio available in 68 patients. The CPO ratio and 24-h CPO, but not the early CPO post PVAD, were significantly associated with 90-day survival, with corresponding area under curve in ROC analysis of 0.816, 0.740, and 0.469, respectively. In multivariate analysis, only the CPO ratio and lactate level at 24 h remained as independent survival predictors. The CPO ratio was not associated with age, sex, and body size. Patients with lower CPO ratio had significantly lower coronary perfusion pressure, worse right heart indices, and higher pulmonary vascular resistance. A lower CPO ratio was also significantly associated with mechanical ventilation and higher creatine kinase levels in myocardial infarction patients. CONCLUSION: In post-PVAD patients, the CPO ratio outperformed the absolute CPO values and other haemodynamic metrics in predicting survival at 90 days. Such a proportional change of CPO over time, likely reflecting native heart function recovery, may help to guide management of CS patients post-PVAD.

6.
J Invasive Cardiol ; 35(7): E394-E397, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37769614

RESUMEN

Traditionally, percutaneous mitral commissurotomy (PMC) is performed under fluoroscopy only. In difficult cases, general anesthesia with transesophageal echocardiography (TEE) guidance is needed. Intracardiac echocardiography (ICE) enables operators to perform PMC under local anesthesia while providing intra-procedural imaging guidance, as in TEE. Hereby, we describe a case of PMC guided by ICE to allow early detection of complications.


Asunto(s)
Apéndice Atrial , Ecocardiografía Transesofágica , Humanos , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Fluoroscopía , Ultrasonografía Intervencional/métodos , Apéndice Atrial/diagnóstico por imagen , Cateterismo Cardíaco/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA