RESUMEN
Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.
Asunto(s)
American Heart Association , Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Estados Unidos , Enfermedades de las Válvulas Cardíacas/terapia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/terapia , Implantación de Prótesis de Válvulas CardíacasRESUMEN
BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.
RESUMEN
AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.
Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Masculino , Humanos , Femenino , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Sistema de Registros , Insuficiencia Cardíaca/complicacionesRESUMEN
BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8â mL, P < .001) and cardiac output (0.6 ± 1.2â L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2â m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Índice de Severidad de la EnfermedadRESUMEN
Current guidelines of aortic stenosis (AS) management focus on valve parameters, LV systolic dysfunction, and symptoms; however, emerging data suggest that there may be benefit of aortic valve replacement before it becomes severe by present criteria. Myocardial assessment using novel multimodality imaging techniques exhibits subclinical myocardial injury and remodeling at various stages before guideline-directed interventions, which predicts adverse outcomes. This raises the question of whether implementing serial myocardial assessment should become part of the standard appraisal, thereby identifying high-risk patients aiming to minimize adverse outcomes.
Asunto(s)
Estenosis de la Válvula Aórtica , Imagen Multimodal , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , MiocardioRESUMEN
Since the 1st discovery of transcriptional enhancers in 1981, their textbook definition has remained largely unchanged in the past 37 years. With the emergence of high-throughput assays and genome editing, which are switching the paradigm from bottom-up discovery and testing of individual enhancers to top-down profiling of enhancer activities genome-wide, it has become increasingly evidenced that this classical definition has left substantial gray areas in different aspects. Here we survey a representative set of recent research articles and report the definitions of enhancers they have adopted. The results reveal that a wide spectrum of definitions is used usually without the definition stated explicitly, which could lead to difficulties in data interpretation and downstream analyses. Based on these findings, we discuss the practical implications and suggestions for future studies.
Asunto(s)
Elementos de Facilitación Genéticos , Edición Génica , Ensayos Analíticos de Alto Rendimiento/métodos , Animales , HumanosRESUMEN
Background and Objective: As one of the most prevalent valvular pathologies affecting millions globally, moderate-to-severe tricuspid regurgitation (TR) predisposes to increased mortality. Despite the well-established risk of adverse outcomes, an overwhelming majority of TR patients are managed conservatively due to challenges associated with timely diagnosis, clinical course of the disease, competing comorbities that carry prohibitive surgical risk, and poor surgical outcomes. These challenges highlight the importance of transcatheter tricuspid valve replacement (TTVR) which has restructured TR management in promising and innovative ways. Methods: We start with an overview of the pathophysiology of TR considering its implications in management. We then elaborate on the current state of TR management, including its limitations, thereby highlighting the unique role of TTVR. This is followed by a review of perioperative considerations such as careful patient selection, role of multimodality imaging, the various imaging techniques that are available and their contribution towards successful TTVR. We then review the valves that are currently available and under investigation, including the latest data available on device efficacy and safety, and highlight the ongoing clinical trials. Results and Conclusions: TTVR is evolving at an exponential pace and has made its mark in the treatment of severe symptomatic tricuspid regurgitation. The promising results sustained by currently available devices and ongoing investigation of valves under development continue to pave the path for further innovation in transcatheter interventions. However, it is important to acknowledge and appreciate the novelty of this approach, the lack of long-term data on safety, efficacy, morbidity, and mortality, and use the lessons learned from real-world experiences to provide a definitive and reproducible solution for patients with symptomatic TR.
RESUMEN
This paper presents a succinct review of attempts in the literature to use game theory to model decision-making scenarios relevant to defence applications. Game theory has been proven as a very effective tool in modelling the decision-making processes of intelligent agents, entities, and players. It has been used to model scenarios from diverse fields such as economics, evolutionary biology, and computer science. In defence applications, there is often a need to model and predict the actions of hostile actors, and players who try to evade or out-smart each other. Modelling how the actions of competitive players shape the decision making of each other is the forte of game theory. In past decades, there have been several studies that applied different branches of game theory to model a range of defence-related scenarios. This paper provides a structured review of such attempts, and classifies existing literature in terms of the kind of warfare modelled, the types of games used, and the players involved. After careful selection, a total of 29 directly relevant papers are discussed and classified. In terms of the warfares modelled, we recognise that most papers that apply game theory in defence settings are concerned with Command and Control Warfare, and can be further classified into papers dealing with (i) Resource Allocation Warfare (ii) Information Warfare (iii) Weapons Control Warfare, and (iv) Adversary Monitoring Warfare. We also observe that most of the reviewed papers are concerned with sensing, tracking, and large sensor networks, and the studied problems have parallels in sensor network analysis in the civilian domain. In terms of the games used, we classify the reviewed papers into papers that use non-cooperative or cooperative games, simultaneous or sequential games, discrete or continuous games, and non-zero-sum or zero-sum games. Similarly, papers are also classified into two-player, three-player or multi-player game based papers. We also explore the nature of players and the construction of payoff functions in each scenario. Finally, we also identify gaps in literature where game theory could be fruitfully applied in scenarios hitherto unexplored using game theory. The presented analysis provides a concise summary of the state-of-the-art with regards to the use of game theory in defence applications and highlights the benefits and limitations of game theory in the considered scenarios.
Asunto(s)
Evolución Biológica , Teoría del JuegoRESUMEN
OBJECTIVES: We investigated the durability of tricuspid regurgitation (TR) reduction and the clinical outcomes through 12 months after transcatheter tricuspid valve repair (TTVr) with the PASCAL Transcatheter Valve Repair System. BACKGROUND: TTVr has rapidly developed and demonstrated favorable acute outcomes, but longer follow-up data are needed. METHODS: Overall, 30 patients (age 77 ± 6 years; 57% female) received PASCAL implantation from September 2017 to May 2019 and completed a clinical follow-up at 12 months. RESULTS: The TR etiology was functional in 25 patients (83%), degenerative in three (10%), and mixed in two (7%). All patients had TR severe or greater (massive or torrential in 80%) and heart failure symptoms (90% in NYHA III or IV) under optimal medical treatment. Single-leaflet device attachment occurred in two patients. Moderate or less TR was achieved in 23/28 patients (82%) at 30 days, which was sustained at 12 months (86%). Two patients underwent repeat TTVr due to residual torrential TR (day 173) and recurrence of severe TR (day 280), respectively. One-year survival rate was 93%; 6 patients required rehospitalization due to acute heart failure. NYHA functional class I or II was achieved in 90% and 6-minute walk distance improved from 275 ± 122 m at baseline to 347 ± 112 m at 12-month (+72 ± 82 m, p < .01). There was no stroke, endocarditis, or device embolization during the follow-up. CONCLUSIONS: Twelve-month outcomes from this multicenter compassionate use experience with the PASCAL System demonstrated high procedural success, acceptable safety, and significant clinical improvement.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Masculino , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugíaRESUMEN
PURPOSE OF REVIEW: Worldwide experience in transcatheter tricuspid valve intervention is increasing as more options become available for the treatment of severe tricuspid regurgitation. These devices can be categorized by their primary mechanism of action, including edge-to-edge leaflet devices, space occupying devices, annuloplasty devices, complete valve replacement and caval valve implantation. This review summarizes the current technologies in use, early clinical results and factors that may affect procedural success. RECENT FINDINGS: Almost all transcatheter devices for tricuspid regurgitation are investigational with very limited evidence. The most commonly used device is the MitraClip (Abbott, Santa Clara, CA, USA) edge-to-edge leaflet device, which is often more effective when the leaflet coaptation gap is not too large (ideally under 7âmm). The Tricuspid Cardioband (Edwards Lifesciences, Irvine, CA, USA) annuloplasty device has CE mark approval with promising short-term procedural results. Guideline-based assessment of disease severity and medication optimization is crucial during heart team evaluation of eligibility for intervention. SUMMARY: Although important lessons have been learned thus far regarding patient and device selection for transcatheter tricuspid regurgitation interventions, the field remains young and further research is needed to optimize treatment in terms of who, when and with what device. Our proposed algorithm for patient selection based on current knowledge incorporates both clinical and anatomic factors.
Asunto(s)
Algoritmos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Selección de Paciente , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco , Humanos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugíaRESUMEN
Recurrent mitral regurgitation (MR) due to mitral annuloplasty ring dehiscence is an uncommon late complication of surgery, and is associated with an increased risk of heart failure and mortality. We report the first application of MitraClip for recurrent primary MR and annuloplasty ring dehiscence in a patient with prohibitive surgical risk.
Asunto(s)
Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Falla de Prótesis , Anciano , Cateterismo Cardíaco/métodos , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Recuperación de la Función , Recurrencia , Reoperación , Índice de Severidad de la Enfermedad , Resultado del TratamientoRESUMEN
PURPOSE OF REVIEW: Mitral regurgitation remains a common problem, and when severe, is associated with significant morbidity and mortality. At present, echocardiography remains the primary modality for assessing both mechanism and severity of mitral regurgitation. However, recent studies demonstrate that the echocardiographic assessment of mitral regurgitation severity may be subject to variability as a result of semiquantitative parameters, dependence upon loading conditions and significant interobserver variability. RECENT FINDINGS: Cardiac magnetic resonance (CMR) imaging is the gold standard in the assessment of cardiac function and structure, and offers an alternative method to estimate mitral regurgitation severity. Herein, we discuss the pitfalls of echocardiography in the assessment of mitral regurgitation and describe recent data demonstrating improved accuracy of CMR in the assessment of mitral regurgitation severity. Further, CMR derived regurgitant volume of ≤55âml is associated with freedom from surgical intervention, in contrast to traditional volumetric measures, which fail to predict the need for surgical intervention. SUMMARY: The CMR assessment of mitral regurgitation severity is easily performed and appears to be more accurate and predictive of the need for surgery than traditional echocardiography. These promising findings require further confirmation in larger outcome trials.
Asunto(s)
Ecocardiografía/métodos , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Humanos , Válvula Mitral , Índice de Severidad de la EnfermedadRESUMEN
X-linked lymphoproliferative disease (XLP) is a primary immunodeficiency caused by mutations in SH2D1A which encodes SAP. SAP functions in signalling pathways elicited by the SLAM family of leukocyte receptors. A defining feature of XLP is exquisite sensitivity to infection with EBV, a B-lymphotropic virus, but not other viruses. Although previous studies have identified defects in lymphocytes from XLP patients, the unique role of SAP in controlling EBV infection remains unresolved. We describe a novel approach to this question using female XLP carriers who, due to random X-inactivation, contain both SAP(+) and SAP(-) cells. This represents the human equivalent of a mixed bone marrow chimera in mice. While memory CD8(+) T cells specific for CMV and influenza were distributed across SAP(+) and SAP(-) populations, EBV-specific cells were exclusively SAP(+). The preferential recruitment of SAP(+) cells by EBV reflected the tropism of EBV for B cells, and the requirement for SAP expression in CD8(+) T cells for them to respond to Ag-presentation by B cells, but not other cell types. The inability of SAP(-) clones to respond to Ag-presenting B cells was overcome by blocking the SLAM receptors NTB-A and 2B4, while ectopic expression of NTB-A on fibroblasts inhibited cytotoxicity of SAP(-) CD8(+) T cells, thereby demonstrating that SLAM receptors acquire inhibitory function in the absence of SAP. The innovative XLP carrier model allowed us to unravel the mechanisms underlying the unique susceptibility of XLP patients to EBV infection in the absence of a relevant animal model. We found that this reflected the nature of the Ag-presenting cell, rather than EBV itself. Our data also identified a pathological signalling pathway that could be targeted to treat patients with severe EBV infection. This system may allow the study of other human diseases where heterozygous gene expression from random X-chromosome inactivation can be exploited.
Asunto(s)
Herpesvirus Humano 4/patogenicidad , Péptidos y Proteínas de Señalización Intracelular/inmunología , Trastornos Linfoproliferativos/patología , Antígenos CD/inmunología , Linfocitos B/patología , Linfocitos B/virología , Antígeno CD48 , Linfocitos T CD8-positivos/inmunología , Linfocitos T CD8-positivos/patología , Linfocitos T CD8-positivos/virología , Células Dendríticas/inmunología , Infecciones por Virus de Epstein-Barr/genética , Infecciones por Virus de Epstein-Barr/inmunología , Infecciones por Virus de Epstein-Barr/virología , Femenino , Genotipo , Herpesvirus Humano 4/inmunología , Humanos , Cambio de Clase de Inmunoglobulina , Gripe Humana/inmunología , Gripe Humana/virología , Péptidos y Proteínas de Señalización Intracelular/genética , Leucocitos Mononucleares/inmunología , Leucocitos Mononucleares/patología , Leucocitos Mononucleares/virología , Trastornos Linfoproliferativos/genética , Trastornos Linfoproliferativos/inmunología , Trastornos Linfoproliferativos/virología , Orthomyxoviridae/inmunología , Orthomyxoviridae/patogenicidad , Receptores de Superficie Celular/inmunología , Receptores Inmunológicos/inmunología , Transducción de Señal , Proteína Asociada a la Molécula de Señalización de la Activación Linfocitaria , Familia de Moléculas Señalizadoras de la Activación Linfocitaria , Miembro 1 de la Familia de Moléculas Señalizadoras de la Activación Linfocitaria , Inactivación del Cromosoma XRESUMEN
BACKGROUND: An increasing number of very elderly patients aged ≥80 years will require aortic valve replacement (AVR) for severe aortic stenosis (AS). Many are classified as high-risk surgical candidates. Transcatheter aortic valve implantation (TAVI) has been proposed as an alternative to surgical AVR (SAVR) for high-risk patients. We evaluated early clinical outcomes of very elderly patients undergoing SAVR to optimise TAVI candidate selection. METHODS: We conducted a retrospective case review of 132 consecutive patients aged ≥80 years undergoing isolated SAVR (49 patients) or combined SAVR/CABG (83 patients) during February 2002-January 2010 at a single tertiary referral hospital. Risk for cardiac surgery was calculated using the logistic EuroSCORE (ES(log)). Mortality and morbidity data were collected for the 30-day postoperative period. RESULTS: Thirty-day mortality rate was 8.3% for patients undergoing SAVR (6.1% for isolated SAVR and 9.6% for SAVR/CABG). Permanent stroke occurred in 3.8% and renal insufficiency in 7.6% of the cohort. Thirty-five percent of patients had left ventricular ejection fraction <50%, 67% had advanced symptoms (NYHA class III or IV), and 42% of patients were stratified as high-risk (ES(log)≥20%). CONCLUSIONS: SAVR can be performed in very elderly patients with acceptable operative morbidity and mortality. The outcomes at our institution are comparable to contemporary SAVR and TAVI outcomes.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Servicios de Salud para Ancianos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Insuficiencia Renal/etiología , Insuficiencia Renal/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Factores de TiempoRESUMEN
Current guidelines of aortic stenosis (AS) management focus on valve parameters, LV systolic dysfunction, and symptoms; however, emerging data suggest that there may be benefit of aortic valve replacement before it becomes severe by present criteria. Myocardial assessment using novel multimodality imaging techniques exhibits subclinical myocardial injury and remodeling at various stages before guideline-directed interventions, which predicts adverse outcomes. This raises the question of whether implementing serial myocardial assessment should become part of the standard appraisal, thereby identifying high-risk patients aiming to minimize adverse outcomes.
Asunto(s)
Estenosis de la Válvula Aórtica , Imagen Multimodal , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Imagen Multimodal/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Miocardio/patología , Imagen por Resonancia Cinemagnética/métodosRESUMEN
Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in â¼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.
Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la EnfermedadRESUMEN
3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.
RESUMEN
BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.
Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de RegistrosRESUMEN
BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).
Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Valor Predictivo de las Pruebas , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Anciano , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Estudios de Factibilidad , Medición de Riesgo , Diseño de Prótesis , Ecocardiografía TridimensionalRESUMEN
BACKGROUND: Transcatheter tricuspid valve intervention (TTVI) has been increasingly adopted in recent years for the treatment of patients with tricuspid regurgitation (TR). However, no dedicated risk stratification has been established for patients undergoing TTVI. OBJECTIVES: The aim of the present study was to propose a dedicated risk score for patients affected by severe TR undergoing TTVI. METHODS: The score was derived from the TRIVALVE (International Multisite Transcatheter Tricuspid Valve Therapies Registry; NCT03416166) registry, according to data availability. A stepwise model approach was used on predictor variables to develop a scoring system for predicting 12-month mortality or rehospitalization using multivariable logistic regression. Internal discrimination, calibration, and validation were assessed using receiver-operating characteristic curve analysis and bootstrapping with 1,000 resamples. RESULTS: A total of 483 patients were included in the study, with an overall 12-month mortality or rehospitalization rate of 19% (n = 94). The final risk score, ranging from 0 to 4.5, included the following 5 parameters (adjusted for age and gender): 1) atrial fibrillation at baseline; 2) glomerular filtration rate <30 mL/min; 3) elevated gamma-glutamyl transferase/bilirubin levels; 4) signs of right heart failure; and 5) left ventricular ejection fraction <50%. The bias-corrected area under the receiver-operating characteristic curve was 68% (95% CI: 62%-75%). A cutoff value of 2.5 demonstrated sensitivity of 65.4% and specificity of 60.5% for the outcome. CONCLUSIONS: The present study proposes a dedicated risk score for patients undergoing TTVI, providing an additional and simple tool for heart teams to select the best therapy for patients affected by severe TR.