Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(2): 366-369, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38044489

RESUMEN

INTRODUCTION: In patients with prior atrial septal defect (ASD) closure and atrial tachyarrhythmias, transseptal puncture can be challenging. METHODS AND RESULTS: This case report discusses a 65-year-old man who had previously undergone pulmonary vein isolation (PVI) and cavo-tricuspid isthmus ablation for atrial fibrillation before ASD closure, respectively. He developed atrial tachycardia (AT) and underwent catheter ablation. AT was diagnosed as peri-mitral flutter and the mitral isthmus (MI) linear ablation via a trans-aortic approach successfully terminated it. CONCLUSION: This case demonstrates the feasibility and safety of transaortic MI linear ablation in patients with ASD closure devices or anatomical challenges when transseptal puncture is difficult.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Defectos del Tabique Interatrial , Taquicardia Supraventricular , Masculino , Humanos , Anciano , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Atrios Cardíacos , Taquicardia/cirugía , Ablación por Catéter/efectos adversos
2.
Pacing Clin Electrophysiol ; 47(4): 561-563, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-37377387

RESUMEN

T-wave oversensing in pacemakers is rare because the set sensitivity is generally fixed. However, several models of pacemaker employ automatic sensitivity adjustment. Here, we present two cases of atrioventricular block treated by implantation of the pacemaker with automatic sensitivity adjustment. After implanting the pacemaker with automatic sensitivity adjustment, ventricular pacing suppression due to T-wave oversensing occurred. In both cases, T-wave oversensing disappeared after adjusting the setting sensitivity from 0.9 to 2.0 mV.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/efectos adversos , Ventrículos Cardíacos
3.
J Cardiovasc Electrophysiol ; 34(8): 1622-1629, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37393602

RESUMEN

INTRODUCTION: Posterior wall isolation (PWI) combined with pulmonary vein isolation (PVI) has proven effective for persistent atrial fibrillation (AF). However, when performing PWI, creating transmural lesions with subendocardial ablation is sometimes difficult. Endocardial unipolar voltage amplitude had a higher sensitivity than bipolar voltage mapping for identifying intramural viable myocardium in the atria. In this study, we aimed to retrospectively investigate the correlation between the residual potential in the posterior wall (PW) following PWI for persistent AF and atrial arrhythmia recurrence using endocardial unipolar voltage. METHODS: This was a single-center observational study. Patients who underwent PVI and PWI for persistent AF in the first procedure between March 2018 and December 2021 at the Tokyo Metropolitan Hiroo Hospital were included in this study. The patients were divided into two groups based on the presence of residual unipolar PW potentials after PWI with a cutoff of 1.08 mV and the recurrence of atrial arrhythmias was compared. RESULTS: In total, 109 patients were included in the analysis. Forty-three patients had residual unipolar potentials after PWI and 66 patients had no residual unipolar potentials. The atrial arrhythmia recurrence rate was significantly higher in the group with residual unipolar potential (41.8% vs. 17.9%, p = 0.003). The residual unipolar potential was an independent predictor of recurrence (odds ratio: 4.53; confidence interval: 1.67-12.3, p = 0.003). CONCLUSION: Residual unipolar potential after PWI for persistent AF is associated with recurrent atrial arrhythmias.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía
4.
J Cardiovasc Electrophysiol ; 34(1): 71-81, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378816

RESUMEN

INTRODUCTION: Local impedance (LI) parameters of IntellaNav STABLEPOINT for successful pulmonary vein isolation (PVI) of atrial fibrillation (AF) remain unclear. The purpose of this study was to seek LI data achieving successful PVI. METHODS: Consecutive AF patients who underwent catheter ablation with STABLEPOINT were prospectively enrolled in two centers. PVI was performed under a constant 35-or 40-watt power, 20-s duration, and >5-g contact force. The operators were blinded to the LI data. The characteristics of all ablation points with/without conduction gaps (Unsuccess or Success tags) after the first-attempt PVI were evaluated for the right/left PVs and anterior/posterior wall (RPV/LPV and AW/PW, respectively), and cutoff values of LI data were calculated for successful lesion formation. RESULTS: A total of 5257 ablation points in 102 patients (65 [58-72] years old, 65.7% male) were evaluated. The LI drop values were higher in the Success tags than Unsuccess tags on the LPV-AW and RPV-AW/PW (p < .001), except for the LPV-PW (p = .105). The %LI drop values (LI drop/initial LI) were higher for the Success tags in all areas (15.8 [12.2%-19.6%] vs. 11.6 [9.7%-15.6%] in LPV-AW: p < .001, 15.0 [11.5%-19.3%] vs. 11.4 [8.7%-17.3%] in LPV-PW: p = .035, 15.3 [11.5%-19.4%] vs. 9.9 [8.1%-13.7%] in RPV-AW: p < .001, and 13.3 [10.1%-17.4%] vs. 8.1 [6.3%-9.5%] in RPV-PW, p < .001). The LI drop and %LI drop cutoff values were 20.0 ohms and 11.6%, respectively. CONCLUSIONS: An insufficient LI drop with STABLEPOINT was associated with a gap formation during PVI, and the best cutoff values for the LI drop and %LI drop were 20.0 ohms and 11.6%, respectively.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Impedancia Eléctrica , Resultado del Tratamiento , Frecuencia Cardíaca , Ablación por Catéter/efectos adversos , Recurrencia
5.
Europace ; 25(4): 1400-1407, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36892146

RESUMEN

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fallo Renal Crónico , Tromboembolia , Humanos , Femenino , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Anticoagulantes/efectos adversos , Hemorragia/inducido químicamente , Tromboembolia/etiología , Tromboembolia/prevención & control , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Ablación por Catéter/efectos adversos , Sistema de Registros
6.
J Cardiovasc Electrophysiol ; 33(11): 2407-2410, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36183403

RESUMEN

Although it is common for bi-atrial tachycardia (AT) circuits to include the Bachmann bundle, there are few reports of its role in left AT circuits. A 77-year-old man was admitted for recurrent AT with a cycle length of 425 ms. The endocardial and epicardial activation map revealed an AT circuit located in the left atrial anterior wall and transverse pericardial sinus, showing a centrifugal pattern stemming from the left atrial appendage. After radiofrequency ablation, AT was no longer induced. This case suggests that the Bachmann bundle may be part of the left AT circuit.


Asunto(s)
Apéndice Atrial , Ablación por Catéter , Taquicardia Supraventricular , Masculino , Humanos , Anciano , Mapeo Epicárdico , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Atrios Cardíacos/cirugía , Taquicardia
7.
Lasers Med Sci ; 37(3): 1567-1573, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34436695

RESUMEN

Excimer laser coronary atherectomy (ELCA) is an effective treatment to remove intracoronary thrombi. In the present study, we compared in-hospital mortality in patients with acute myocardial infarction (AMI) who underwent conventional treatment and conventional treatment plus ELCA. Among 656 patients who were admitted to our hospital through the Tokyo CCU Network, 104 patients with AMI who were treated by percutaneous coronary intervention between January 2013 and December 2016 met inclusions criteria and underwent conventional treatment with ELCA (ELCA group) and 89 underwent conventional treatment alone (conventional group). We retrospectively evaluated in-hospital mortality within 30 days and used propensity score (PS) matching to reduce assignment bias and multivariate analysis to detect the predictors of in-hospital mortality. In-hospital mortality rate was significantly lower in the ELCA group before and after PS matching (2.9% vs. 13.5%, p = 0.006 before PS matching, and 2.8% vs. 14.1%, p = 0.016 after PS matching). After PS matching, ß-blocker or statins use, incidence of shock, Killip classification, and door-to-balloon time were not significantly different. A multivariate logistic regression analysis identified ELCA, dyslipidemia, shock, and left ventricular ejection fraction as independent predictors of in-hospital mortality (odds ratio (OR), 0.147, 95% confidence interval [CI], 0.022-0.959, p = 0.045; OR, 0.077, 95% CI, 0.007-0.805, p = 0.032; OR, 6.494, 95% CI, 1.228-34.34, p = 0.028; OR, 0.890, 95% CI, 0.828-0.957, p = 0.002, respectively). Our data indicate that ELCA with the small diameter and low level emission may reduce the in-hospital mortality compared to conventional methods in patients with AMI in drug-eluting stent era.


Asunto(s)
Aterectomía Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Aterectomía Coronaria/efectos adversos , Angiografía Coronaria , Humanos , Láseres de Excímeros/efectos adversos , Infarto del Miocardio/cirugía , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda
8.
J Cardiovasc Electrophysiol ; 32(3): 597-604, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33484213

RESUMEN

INTRODUCTION: It is important to consider recurrent arrhythmia after catheter ablation for persistent atrial fibrillation (AF) for planning an ablation strategy. However, the studies are limited to pulmonary vein isolation (PVI) plus posterior wall isolation (PWI), which were reported to improve procedural outcomes. The objective of this study is to evaluate the effect of PWI on recurrent arrhythmia. METHODS: This is an observational study on patients with persistent AF comparing PVI plus PWI and PVI only strategies. In PVI plus PWI group, linear ablation of the left atrium roofline and bottom line were performed to achieve PWI after PVI. Some patients with AF recurrence underwent the second procedure. The presence of recurrent arrhythmia and results of the second procedures were evaluated. RESULTS: A total of 181 patients (mean age, 66.9 ± 10.2 years; male, 76.8%) were included. PVI plus PWI group and PVI only group consisted of 90 and 91 patients, respectively. AF recurrence was observed in 28 of 90 (31.1%) patients with PVI plus PWI and in 43 of 91 (47.3%) with PVI only, and log-rank test did not show any significant difference (p = .35). The occurrence of recurrent persistent AF was significantly lower in PVI plus PWI group than in PVI only group (5/90; 5.6% vs. 18/91; 20.9%, p = .002). There was no significant difference between the two groups in recurrent paroxysmal AF and atrial tachycardia (AT). CONCLUSION: PWI, in addition to PVI, for persistent AF was significantly related to fewer episodes of recurrent persistent AF, and it did not increase recurrent AT.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 32(5): 1461-1463, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33783898

RESUMEN

The Accufix bipolar active fixation atrial pacing lead (Model 330-801; Telectronics) can have mechanical complications due to a fracture of its J retention wire. An 80-year-old man had the Accufix atrial pacing lead implanted 29 years prior, and surgical removal was required because a part of the lead was perforating the apex of the right ventricle. Regular follow-up examinations are recommended to eliminate the possibility of protrusion and detachment of the J retention wire, even if the clinical course after implantation is stable for a prolonged period.


Asunto(s)
Electrodos Implantados , Marcapaso Artificial , Anciano de 80 o más Años , Electrodos Implantados/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Marcapaso Artificial/efectos adversos
10.
J Cardiovasc Electrophysiol ; 32(1): 41-48, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33206418

RESUMEN

INTRODUCTION: In patients with coronary artery disease, a high coronary artery calcium score (CACS) correlates with atrial fibrillation (AF); however, the association between left atrial (LA) remodeling progression and coronary arteriosclerosis is unclear. This study aimed to evaluate the relationship between LA remodeling progression and the CACS. METHODS: This retrospective study enrolled 148 patients with AF (paroxysmal AF, n = 94) who underwent catheter ablation. Voltage mapping for the left atrium and coronary computed tomography for CACS calculations were performed. The ratio of the LA low-voltage area (LA-LVA), defined by values less than 0.5 mV divided by the total LA surface without pulmonary veins, was calculated. Patients with LA-LVA (<0.5 mV) >5% and ≤5% were classified as the LVA (n = 30) and non-LVA (n = 118) groups, respectively. Patient characteristics and CACS values were compared between the two groups. RESULTS: LA volume, age, CHA2 DS2 VASc score, and percentage of female patients were significantly higher, and the estimated glomerular filtration rate was lower in the LVA group than in the non-LVA group. The CACS was significantly higher in the LVA group (248.4 vs. 13.2; p = .001). Multivariate analysis identified the LA volume index and CACS as independent predictors of LA-LVA (<0.5 mV) greater than 5%. The areas under the receiver operating characteristic curves for predicting LA-LVA (<0.5 mV) greater than 5% with CACS were 0.695 in the entire population, 0.782 in men, and 0.587 in women. CONCLUSION: Progression of LA remodeling and coronary artery calcification may occur in parallel. A high CACS may indicate advanced LA remodeling, especially in men.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Calcio , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Técnicas Electrofisiológicas Cardíacas , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Masculino , Estudios Retrospectivos , Caracteres Sexuales
11.
J Cardiovasc Electrophysiol ; 31(8): 2013-2021, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32468685

RESUMEN

INTRODUCTION: Successful pulmonary vein isolation (PVI) can improve the quality of life (QOL) of patients with atrial fibrillation (AF). However, the role of durable PVI for such QOL improvement is not known. The aim of this study was to clarify the effectiveness of durable PVI in improving the QOL of patients with AF. METHODS AND RESULTS: We assessed 119 patients who underwent PVI (age 66.4 ± 9.6 years, 104 paroxysmal AF). A scheduled electrophysiological study was performed 6 months after the first PVI session-regardless of recurrence of AF-to assess the durability of PVI and to identify and re-isolate reconnected pulmonary veins. QOL scores were evaluated by an AF-specific QOL questionnaire and checked at baseline, 6 months, and 1 year after the first session. In patients without AF recurrence (nonrecurrence group, n = 93), the scores at 6 months improved compared with those at baseline; conversely, the scores did not improve in patients with AF recurrence (n = 26). Nevertheless, the scores at 1 year improved compared with those at 6 months in both groups. Within the nonrecurrence group, the score difference between 6 months and baseline was higher in the durable PVI group (n = 58) than that in the nondurable PVI group (n = 35). CONCLUSIONS: The QOL of AF patients improved by the resumption of sinus rhythm following PVI. Patients with durable PVI had increased QOL scores compared with those with nondurable PVI. The durability of PVI may achieve further improvements in the QOL of patients with AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Humanos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 31(6): 1298-1306, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32270566

RESUMEN

INTRODUCTION: This study aimed to compare touch-up ablation (TUA) rates and pulmonary vein isolation (PVI) durability of hot balloon ablation (HBA) and cryoballoon ablation (CBA) in paroxysmal atrial fibrillation (PAF) patients. METHODS: In total, 137 PAF patients were enrolled in the study. Among them, 59 underwent two HBA procedures at 6-month intervals and 78 patients underwent two CBA sessions, both regardless of atrial fibrillation recurrence. Propensity score matching was performed to estimate similar patient characteristics between the HBA and CBA groups. RESULTS: Each group comprised of 46 matched patients for comparison. The TUA rate at the first session was higher for HBA (49 of 184 PVs) than for CBA (20 PVs) (P = .01), with the highest incidence at the left superior pulmonary vein (LSPV). The rates of PVI durability at the second session performed 7 months later were similar between HBA (168 of 184 PVs) and CBA (162 PVs) groups. The PVI durability rate at the TUA sites of the first session was higher for HBA than for CBA (41 of 49 PVs vs 10 PVs, respectively; P = .01). Fifty percent of the patients underwent HBA at 73°C for the LSPV. HBA performed at 73°C yielded a lower TUA rate than that at 70°C (16 of 23 PVs vs 7 of 23 PVs; P = .008). CONCLUSIONS: While PVI durability was similar between HBA and CBA, the TUA rate was higher for HBA than for CBA, especially on the LSPV. For LSPV, HBA at a balloon temperature of 73°C may reduce the TUA rate.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Calor/uso terapéutico , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Criocirugía/efectos adversos , Criocirugía/instrumentación , Femenino , Frecuencia Cardíaca , Calor/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 30(2): 263-264, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30288841

RESUMEN

A 79-year-old woman with a history of pulmonary vein isolation for persistent atrial fibrillation was admitted for recurrence of atrial tachycardia, with a tachycardia cycle length of 236 milliseconds. The ultra-high-resolution mapping system revealed that tachycardia circuit detouring the epicardium at the anterior wall scar and breaking through to the endocardium below the left atrial appendage. Radiofrequency energy was applied to this site, which successfully terminated the tachycardia. This case suggests that epicardial conduction could occur even at the left atrial anterior wall and identifies a variation in epicardial conduction around the left atrium, which could be a tachycardia circuit.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Pericardio/fisiopatología , Taquicardia Supraventricular/diagnóstico , Potenciales de Acción , Anciano , Ablación por Catéter , Femenino , Atrios Cardíacos/cirugía , Humanos , Pericardio/cirugía , Valor Predictivo de las Pruebas , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
14.
J Cardiovasc Electrophysiol ; 30(4): 575-581, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30710406

RESUMEN

INTRODUCTION: While characteristic waveforms of 12-lead electrocardiograms have been reported to predict the epicardial origin of ventricular tachycardia (VT), it has not been fully examined whether ventricular intracardiac electrograms (VEGMs) recorded from the implantable cardioverter defibrillator (ICD) via telemetry can determine the origin of VT or not. The aim of this study was to investigate the VEGM characteristics of VT originating from the epicardia. METHOD AND RESULTS: Intracardiac VEGMs of the induced VTs, with detected sites of origin during the VT study, were recorded in 15 (23 VTs) of the 46 patients. The characteristics of the 23 VTs were evaluated using far-field and near-field VEGMs recorded via telemetry. Five of 23 VTs were found to be focused on the epicardial site (epi group) and 18 VTs were focused on the endocardium (endo group). VTs of the epi group had longer VEGM duration in far-field EGM than those of the endo group (epi group: 240 ± 49 ms vs endo group: 153 ± 45 ms; P = 0.002) and the duration from the onset to the peak of VEGM was also longer than that of the endo group (epi group: 153 ± 53 ms vs endo group: 63 ± 28 ms; P < 0.001). There was no difference in the V wave duration in tip-ring EGM between both groups (epi group: 122 ± 52 ms vs endo group: 98 ± 6 ms; P = 0.377). CONCLUSION: Evaluation of intracardiac VEGM before VT ablation may be helpful to predict the epicardial origin of VT in patients with an ICD.


Asunto(s)
Potenciales de Acción , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Frecuencia Cardíaca , Pericardio/fisiopatología , Taquicardia Ventricular/diagnóstico , Telemetría/instrumentación , Anciano , Ablación por Catéter , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía , Factores de Tiempo
15.
J Cardiovasc Electrophysiol ; 29(1): 138-145, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28988444

RESUMEN

BACKGROUND: During epicardial mapping, determination of appropriate ablation sites in low voltage areas (LVA) is challenging because of large epicardial areas covered by adipose tissue. OBJECTIVE: To evaluate the impedance difference between epicardial fat and the epicardial LVA using multiple detector computed tomography (MDCT). METHODS: We enrolled patients who underwent ventricular tachycardia (VT) ablation via the epicardial approach after endocardial ablation failure. After the procedure, MDCT-derived images of epicardial fat were loaded to the mapping system. Then, all points acquired during sinus rhythm were retrospectively superimposed and analyzed. RESULTS: This study included data from 7 patients (62.5 ± 3.9 years old) who underwent eight epicardial VT ablation procedures. After the procedure, MDCT-derived images of epicardial fat were registered in eight procedures. Retrospective analysis of 1,595 mapping and 236 ablation points was performed. Of the 1,595 mapping points on the merged electroanatomical and epicardial fat maps, normal voltage area (NVA) and low voltage area (LVA) without fat had lower impedance than those with fat (NVA without fat 182 ± 46 Ω vs. NVA with fat 321 ± 164.0 Ω, P  =  0.001, LVA without fat 164 ± 69 Ω vs. LVA with fat 248 ± 89 Ω, P  =  0.002). Of the 236 ablation points, initial impedance before ablation was higher on epicardial fat than on epicardial LVA without fat (134 ± 16 Ω vs. 156 ± 28 Ω, P  =  0.01). CONCLUSIONS: Real time epicardial impedance evaluation may be useful to determine effective epicardial ablation sites and avoid adipose tissue. However, the number of patients in the present study is limited. Further investigation with a large number of patients is needed to confirm our result.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Ablación por Catéter , Tomografía Computarizada Multidetector , Pericardio/diagnóstico por imagen , Taquicardia Ventricular/diagnóstico por imagen , Potenciales de Acción , Tejido Adiposo/fisiopatología , Tejido Adiposo/cirugía , Anciano , Impedancia Eléctrica , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Pericardio/fisiopatología , Pericardio/cirugía , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía
16.
Circ J ; 81(2): 235-240, 2017 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-28003574

RESUMEN

BACKGROUND: Sodium bicarbonate and ascorbic acid have been proposed to prevent contrast-induced nephropathy (CIN). The present study evaluated the effect of their combined use on CIN incidence.Methods and Results:We prospectively enrolled 429 patients with chronic kidney disease (CKD: baseline estimated glomerular filtration rate <60 mL/min/1.73 m2) prior to elective coronary catheterization. CIN was defined as absolute (≥0.5 mg/dL) or relative (≥25%) increase in serum creatinine within 72 h. In the saline hydration (n=218) and combined sodium bicarbonate+ascorbic acid (n=211) groups, a total of 1,500-2,500 mL 0.9% saline was given before and after the procedure. In addition, the combination group received 20 mEq sodium bicarbonate and 3 g ascorbic acid i.v. before the procedure, followed by 2 g ascorbic acid after the procedure and a further 2 g after 12 h. There were no significant differences between the basic characteristics and contrast volume in the 2 groups. CIN occurred in 19 patients (8.7%) in the saline group, and in 6 patients (2.8%) in the combined treatment group (P=0.008). CONCLUSIONS: Combined sodium bicarbonate and ascorbic acid could prevent CIN following catheterization in CKD patients.


Asunto(s)
Ácido Ascórbico/uso terapéutico , Medios de Contraste/efectos adversos , Nefrosis/prevención & control , Insuficiencia Renal Crónica/complicaciones , Bicarbonato de Sodio/uso terapéutico , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Creatinina/sangre , Quimioterapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nefrosis/inducido químicamente , Insuficiencia Renal Crónica/terapia
17.
Europace ; 18(8): 1252-8, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26559917

RESUMEN

AIMS: An early repolarization (ER) pattern is a risk factor for ventricular fibrillation (VF) in certain diseases. However, it is unclear whether this association holds for patients with vasospastic angina (VSA). Moreover, the reported long-term follow-up of implantable cardioverter defibrillator (ICD) therapy for VSA patients is limited to 3 years. This study aimed to clarify the relation between ER and VF in patients with VSA and to investigate the long-term outcomes of ICD therapy. METHODS AND RESULTS: This retrospective, observational survey evaluated 265 consecutive VSA patients, including 21 with VF. Their electrocardiogram findings and clinical course were analysed over a mean follow-up of 5.5 ± 3.3 years. Early repolarization was observed in 64 patients (24.2%) and was more frequent in patients with VF history than those without (P = 0.001). Early repolarization was independently associated with VF history. During follow-up, four patients had VF recurrences. Ventricular fibrillation recurrence was higher in patients with ER (log-rank, P = 0.018) or VF history (log-rank, P < 0.001) than those without. Among patients with ER, day-to-day variations in ER (P = 0.003) and notching of ER pattern (P = 0.03) were associated with VF history. Cases with day-to-day variation showed a higher incidence of VF recurrence during follow-up (log-rank, P = 0.007). During long-term follow-up, 23.5% of patients with an ICD received appropriate shock therapy. CONCLUSION: The presence of ER, especially with day-to-day variation, can help predict VF recurrence in VSA patients. Implantable cardioverter defibrillator implantation is a reasonable approach for the secondary prevention of VF in high-risk VSA patients.


Asunto(s)
Angina de Pecho/complicaciones , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Fibrilación Ventricular/terapia , Anciano , Angina de Pecho/diagnóstico por imagen , Angiografía Coronaria , Electrocardiografía , Femenino , Humanos , Japón , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Prevención Secundaria
18.
J Electrocardiol ; 49(1): 18-22, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26607406

RESUMEN

We performed catheter ablation to septal superior vena cava (SVC)-right atrium (RA) junction rapid firing in a 57-year-old man with paroxysmal atrial fibrillation. He later experienced transient sinus node dysfunction resulting from injury to the sinus node artery (SNA), which branched only from the proximal region of the left circumflex artery. The direction of the SNA should be considered during catheter ablation at the septal SVC-RA junction, especially if the sinus node is supplied by only one SNA from the right coronary artery or the left circumflex artery.


Asunto(s)
Ablación por Catéter/efectos adversos , Estenosis Coronaria/etiología , Vasos Coronarios/lesiones , Atrios Cardíacos/cirugía , Síndrome del Seno Enfermo/etiología , Vena Cava Superior/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Diagnóstico Diferencial , Electrocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Síndrome del Seno Enfermo/diagnóstico , Resultado del Tratamiento , Vena Cava Superior/diagnóstico por imagen
20.
Heart Vessels ; 29(3): 417-21, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23893269

RESUMEN

A 47-year-old man underwent slow pathway ablation for slow-fast atrioventricular nodal reentrant tachycardia. Following the procedure, he felt palpitations while swallowing, and swallowing-induced atrial tachycardia was diagnosed. Swallowing-induced atrial tachycardia arose from the right atrium-superior vena cava junction and was cured by catheter ablation. After the procedure, the patient's heart rate variability changed significantly, indicating suppression of parasympathetic nerve activity. In this case, swallowing-induced atrial tachycardia was related to the vagal nerve reflex. Analysis of heart rate variability may be helpful in elucidating the mechanism of swallowing-induced atrial tachycardia.


Asunto(s)
Ablación por Catéter , Deglución , Frecuencia Cardíaca , Taquicardia Supraventricular/cirugía , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Reflejo , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento , Nervio Vago/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA