Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ann Intern Med ; 175(12): 1658-1665, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36343346

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) improve survival in patients at risk for cardiac arrest, but are associated with intravascular lead-related complications. The subcutaneous ICD (S-ICD), with no intravascular components, was developed to minimize lead-related complications. OBJECTIVE: To assess key ICD performance measures related to delivery of ICD therapy, including inappropriate ICD shocks (delivered in absence of life-threatening arrhythmia) and failed ICD shocks (which did not terminate ventricular arrhythmia). DESIGN: Randomized, multicenter trial. (ClinicalTrials.gov: NCT02881255). SETTING: The ATLAS trial. PATIENTS: 544 eligible patients (141 female) with a primary or secondary prevention indication for an ICD who were younger than age 60 years, had a cardiogenetic phenotype, or had prespecified risk factors for lead complications were electrocardiographically screened and 503 randomly assigned to S-ICD (251 patients) or transvenous ICD (TV-ICD) (252 patients). Mean follow-up was 2.5 years (SD, 1.1). Mean age was 49.0 years (SD, 11.5). MEASUREMENTS: The primary outcome was perioperative major lead-related complications. RESULTS: There was a statistically significant reduction in perioperative, lead-related complications, which occurred in 1 patient (0.4%) with an S-ICD and in 12 patients (4.8%) with TV-ICD (-4.4%; 95% CI, -6.9 to -1.9; P = 0.001). There was a trend for more inappropriate shocks with the S-ICD (hazard ratio [HR], 2.37; 95% CI, 0.98 to 5.77), but no increase in failed appropriate ICD shocks (HR, 0.61 (0.15 to 2.57). Patients in the S-ICD group had more ICD site pain, measured on a 10-point numeric rating scale, on the day of implant (4.2 ± 2.8 vs. 2.9 ± 2.2; P < 0.001) and 1 month later (1.3 ± 1.8 vs. 0.9 ± 1.5; P = 0.035). LIMITATION: At present, the ATLAS trial is underpowered to detect differences in clinical shock outcomes; however, extended follow-up is ongoing. CONCLUSION: The S-ICD reduces perioperative, lead-related complications without significantly compromising the effectiveness of ICD shocks, but with more early postoperative pain and a trend for more inappropriate shocks. PRIMARY FUNDING SOURCE: Boston Scientific.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Femenino , Humanos , Desfibriladores Implantables/efectos adversos , Resultado del Tratamiento , Arritmias Cardíacas , Factores de Riesgo , Muerte Súbita Cardíaca/etiología
2.
Am Heart J ; 207: 1-9, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30399474

RESUMEN

BACKGROUND: The defibrillator lead is the weakest part of the transvenous (TV) implantable cardioverter defibrillation (ICD) system and a frequent cause of morbidity. Lead dislodgement, cardiac perforation, insertion-related trauma including pneumothorax and vascular injury, are common early complications of TV-ICD implantation. Venous occlusion, tricuspid valve dysfunction, lead fracture and lead insulation failure are additional, later complications. The introduction of a totally sub-cutaneous ICD (S-ICD) may reduce these lead-related issues, patient morbidity, hospitalizations and costs. However, such benefits compared to the TV-ICD have not been demonstrated in a randomized trial. DESIGN: ATLAS (Avoid Transvenous Leads in Appropriate Subjects) is a multi-centered, randomized, open-label, parallel group trial. Patients younger than 60 years are eligible. If older than 60 years, patients are eligible if they have an inherited heart rhythm disease, or risk factors for ICD-related complication, such as hemodialysis, a history of ICD or pacemaker infection, heart valve replacement, or severe pulmonary disease. This study will determine if using an S-ICD compared to a TV-ICD reduces a primary composite outcome of perioperative complications including pulmonary or pericardial perforation, lead dislodgement or dysfunction, tricuspid regurgitation and ipsilateral venous thrombosis. Five hundred patients will be enrolled from 14 Canadian hospitals, and data collected to both early- (at 6 months) and mid-term complications (at 24 months) as well as mortality and ICD shock efficacy. SUMMARY: The ATLAS randomized trial is comparing early- and mid-term vascular and lead-related complications among S-ICD versus TV-ICD recipients who are younger or at higher risk of ICD-related complications.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Falla de Equipo , Selección de Paciente , Complicaciones Posoperatorias/prevención & control , Adulto , Comités Consultivos , Factores de Edad , Canadá , Diseño de Equipo , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Proyectos de Investigación , Factores de Riesgo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA