Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Cancer ; 22(1): 151, 2022 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-35130848

RESUMEN

BACKGROUND: The surgical management of Mayo III/IV tumor thrombi is difficult and risky, and robotic surgery is even more difficult. The purpose of this study was to introduce the step-by-step and orderly lowering of the height of inferior vena cava tumor thrombus, which was the core technique of robot operation for Mayo III/IV tumor thrombus. METHOD: A total of 18 patients were included in this study. The average tumor thrombus height was 2.4 cm above the level of the second porta hepatis (SPH), and 9 patients were prepared for cardiopulmonary bypass (CPB) before surgery. During the operation, the height of the tumor thrombus was lowered orderly for 2-3 times, and the blood flow blocking method was changed sequentially. The CPB was required when tumor thrombus in the atrium; After the height of the thrombus was lowered to the atrium entrance, CPB was stopped and the blood flow was blocked in the upper- and retro-hepatic inferior vena cava (IVC); After the tumor thrombus continued to descend to the lower part of the SPH, liver blood flow could be restored, and then, the blood flow was simply blocked in the retro-hepatic IVC to complete the removal of the thrombus and the repair or resection of the IVC. Finally, the diseased kidney and renal vein were removed. RESULTS: All operations were successfully completed, and 2 cases were transferred to laparotomy. Seven cases received CPB, while the other 11 did not. 15 patients underwent two times of the lowering of the tumor thrombus, 2 patients underwent one time and 1 patient underwent three times. The mean liver/IVC dissociation and vascular suspension time was 22.0 min. All patients had less than Clavien-Dindo grade III complications, no serious complications occurred during operation, and no patient died within 90 days. CONCLUSIONS: The step-by-step and orderly decline of tumor thrombus height is the key to the success of robot Mayo III / IV tumor thrombus surgery. This method can shorten FPH and CPB time and improve the success rate of surgery.


Asunto(s)
Neoplasias Renales/irrigación sanguínea , Procedimientos Quirúrgicos Robotizados/métodos , Trombectomía/métodos , Vena Cava Inferior/cirugía , Trombosis de la Vena/cirugía , Anciano , Femenino , Humanos , Riñón/irrigación sanguínea , Riñón/cirugía , Neoplasias Renales/complicaciones , Masculino , Persona de Mediana Edad , Venas Renales/cirugía , Resultado del Tratamiento , Trombosis de la Vena/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA