Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 51(5): 1215-1220, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38082197

RESUMEN

This study aimed to determine whether the whole-body bone Single Photon Emission Computed Tomography (SPECT) recording times of around 10 min, routinely provided by a high-sensitivity 360° cadmium and zinc telluride (CZT) camera, can be further reduced by a deep-learning noise reduction (DLNR) algorithm. METHODS: DLNR was applied on whole-body images recorded after the injection of 545 ± 33 MBq of [99mTc]Tc-HDP in 19 patients (14 with bone metastasis) and reconstructed with 100%, 90%, 80%, 70%, 60%, 50%, 40%, and 30% of the original SPECT recording times. RESULTS: Irrespective of recording time, DLNR enhanced the contrast-to-noise ratios and slightly decreased the standardized uptake values of bone lesions. Except in one markedly obese patient, the quality of DLNR processed images remained good-to-excellent down to 60% of the recording time, corresponding to around 6 min SPECT-recording. CONCLUSION: Ultra-fast SPECT recordings of 6 min can be achieved when DLNR is applied on whole-body bone 360° CZT-SPECT.


Asunto(s)
Cadmio , Aprendizaje Profundo , Humanos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Telurio , Zinc
2.
Eur J Nucl Med Mol Imaging ; 51(9): 2672-2683, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38637354

RESUMEN

BACKGROUND: Amino acid PET is recommended for the initial diagnosis of brain lesions, but its value for identifying aggressive lesions remains to be established. The current study therefore evaluates the added-value of dynamic [18 F]FDOPA PET as an adjunct to conventional MRI for determining the aggressiveness of presumed glial lesions at diagnosis. METHODS: Consecutive patients, with a minimal 1 year-follow-up, underwent contrast-enhanced MRI (CE MRI) and dynamic [18 F]FDOPA PET to characterize their suspected glial lesion. Lesions were classified semi-automatically by their CE MRI (MRI-/+), and PET parameters (static tumor-to-background ratio, TBR; dynamic time-to-peak ratio, TTPratio). Diagnostic accuracies of MRI and PET parameters for the differentiation of tumor aggressiveness were evaluated by chi-square test or receiver operating characteristic analyses. Aggressive lesions were either defined as lesions with dismal molecular characteristics based on the WHO 2021 classification of brain tumors or with compatible clinico-radiological profiles. Time-to-treatment failure (TTF) and overall survival (OS) were evaluated. RESULTS: Of the 109 patients included, 46 had aggressive lesions (45 confirmed by histo-molecular analyses). CE MRI identified aggressive lesions with an accuracy of 73%. TBRmax (threshold of 3.2), and TTPratio (threshold of 5.4 min) respectively identified aggressive lesions with an accuracy of 83% and 76% and were independent of CE MRI and clinical factors in the multivariate analysis. Among the MRI-lesions, 11/56 (20%) were aggressive and respectively 55% and 50% of these aggressive lesions showed high TBRmax and short TTPratio in PET. High TBRmax and short TTPratio in PET were significantly associated to poorer survivals (p ≤ 0.009). CONCLUSION: Dynamic [18 F]FDOPA PET provides a similar diagnostic accuracy as contrast enhancement in MRI to identify the aggressiveness of suspected glial lesions at diagnosis. Both methods, however, are complementary and [18 F]FDOPA PET may be a useful additional tool in equivocal cases.


Asunto(s)
Neoplasias Encefálicas , Dihidroxifenilalanina , Glioma , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Humanos , Masculino , Femenino , Dihidroxifenilalanina/análogos & derivados , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Adulto , Glioma/diagnóstico por imagen , Glioma/patología , Anciano , Adulto Joven
3.
Eur J Nucl Med Mol Imaging ; 51(5): 1323-1332, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38114618

RESUMEN

PURPOSE: Dopamine transporter (DAT) imaging is used to support the diagnosis of neurodegenerative parkinsonian disorders. Specific medications have been reported to confound the interpretation of [123I]I-FP-CIT SPECT scans, but there is limited data. The aim of the current study is to identify potential medication effects on the interpretation of [123I]I-FP-CIT SPECT scans in routine practice. MATERIALS AND METHODS: Consecutive patients undergoing a [123I]I-FP-CIT SPECT/CT scan on a 360° CZT camera between September 2019 and December 2022 were included. An exhaustive review of patient medications (antidepressants, antipsychotics, anti-epileptics, anti-parkinsonians, benzodiazepines, lithium, opioids, and stimulants) was performed. Two experienced nuclear physicians, blinded to the medication reports, interpreted the [123I]I-FP-CIT SPECT scans visually and a semi-quantitative analysis was performed using a local normal database. RESULTS: The study included 305 patients (71.0 ± 10.4, 135 women) and 145 (47.5%) visually interpreted normal scans. In normal scans, the striatum/occiput radioligand uptake ratio was decreased by noradrenergic and specific serotonergic antidepressants (NASSAs) (n = 15, z-score of - 0.93) and opioid medication (tramadol, n = 6, z-score of - 0.85) and was associated with a younger age in the multivariate analysis. In the overall population, the striatum/occiput ratio was influenced by NASSAs and associated with consensual visual analysis, age, sex, and anti-parkinsonian medications related to the status of the disease. CONCLUSION: Our study confirms the potential impact of antidepressant (NASSA) and opioid (tramadol) medications on the semi-quantitative analysis of [123I]I-FP-CIT SPECT scans. However, when performing a visual analysis, only NASSAs significantly impacted the interpretation of [123I]I-FP-CIT SPECT scans.


Asunto(s)
Enfermedades Neurodegenerativas , Tramadol , Humanos , Femenino , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática , Analgésicos Opioides , Imágenes Dopaminérgicas , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tropanos , Antidepresivos
4.
J Nucl Cardiol ; 35: 101849, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38508443

RESUMEN

BACKGROUND: The outcome of breast cancer (BrCa) women monitored by low-dose equilibrium radionuclide angiography (ERNA) remains challenging to predict. AIM: This study aims to determine whether heart rate (HR)/blood pressure (BP) ratio-based indexes, previously confirmed to predict outcomes of various diseases, also predict BrCa-therapy-related cardiotoxicity and survival. METHODS: Predictors of cardiotoxicity and survival were determined among pre-therapy variables, including shock index ([SI HR/systolic BP) and age-adjusted SI (ASI), in a female BrCa cohort with normal baseline ERNA-left ventricular ejection fraction (LVEF). RESULTS: We included 274 women with a median age of 54.8 (interquartile range: 45.5-65.4) years, 271 treated with anthracyclines and 96 with trastuzumab. During a median follow-up of 25.9 (18.6-33.5) months, 31 women developed cardiotoxicity (LVEF: <50% and ≥10% drop from baseline), and 25 died. Baseline ASI was a multivariate predictor (p < 0.001) of (i) cardiotoxicity, in association with trastuzumab treatment (p = 0.010), and LV end-diastolic volume (p = 0.001) and (ii) survival, in association with metastasis (p < 0.001) and estimated glomerular filtration rate (p = 0.008). Cardiotoxicity poorly impacted survival (p = 0.064). The 36-month cardiotoxicity and mortality rates were markedly higher for patients in the upper half of baseline ASI values (ASI: >30 years min-1.mmHg-1, 16.5% and 20.7%, respectively) than in the lower half (7.6% and 4.5%, respectively, both p < 0.05). CONCLUSIONS: In BrCa women with normal baseline ERNA-LVEF, HR/BP ratio-based indexes unmask hemodynamic profiles associated with increased cardiotoxicity risk and decreased survival, highlighting the need for a comprehensive assessment of cardiac- and vascular-related risks in BrCa women monitored by ERNA. CONDENSED ABSTRACT: In a cohort of 274 women BrCa women who were monitored by ERNA for potentially cardiotoxic drugs (anthracyclines or trastuzumab) and who had no history of cardiac disease and a normal left ventricular ejection fraction before treatment, baseline indexes based on HR/BP ratios unmask hemodynamic profiles strongly associated with an increased risk of cardiotoxicity and subsequently decreased survival. Although further validations in other cohorts are needed, these findings highlight the need for a more comprehensive assessment of the cardiac- and vascular-related risk in BrCa women monitored by ERNA.


Asunto(s)
Neoplasias de la Mama , Cardiotoxicidad , Trastuzumab , Humanos , Femenino , Persona de Mediana Edad , Neoplasias de la Mama/tratamiento farmacológico , Anciano , Trastuzumab/efectos adversos , Hemodinámica/efectos de los fármacos , Antraciclinas/efectos adversos , Volumen Sistólico/efectos de los fármacos , Frecuencia Cardíaca/efectos de los fármacos , Presión Sanguínea/efectos de los fármacos , Imagen de Acumulación Sanguínea de Compuerta , Factores de Riesgo
5.
Eur Radiol ; 33(10): 7089-7098, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37148355

RESUMEN

OBJECTIVES: Tumor dosimetry with somatostatin receptor-targeted peptide receptor radionuclide therapy (SSTR-targeted PRRT) by 177Lu-DOTATATE may contribute to improved treatment monitoring of refractory meningioma. Accurate dosimetry requires reliable and reproducible pretherapeutic PET tumor segmentation which is not currently available. This study aims to propose semi-automated segmentation methods to determine metabolic tumor volume with pretherapeutic 68Ga-DOTATOC PET and evaluate SUVmean-derived values as predictive factors for tumor-absorbed dose. METHODS: Thirty-nine meningioma lesions from twenty patients were analyzed. The ground truth PET and SPECT volumes (VolGT-PET and VolGT-SPECT) were computed from manual segmentations by five experienced nuclear physicians. SUV-related indexes were extracted from VolGT-PET and the semi-automated PET volumes providing the best Dice index with VolGT-PET (Volopt) across several methods: SUV absolute-value (2.3)-threshold, adaptative methods (Jentzen, Otsu, Contrast-based method), advanced gradient-based technique, and multiple relative thresholds (% of tumor SUVmax, hypophysis SUVmean, and meninges SUVpeak) with optimal threshold optimized. Tumor-absorbed doses were obtained from the VolGT-SPECT, corrected for partial volume effect, performed on a 360° whole-body CZT-camera at 24, 96, and 168 h after administration of 177Lu-DOTATATE. RESULTS: Volopt was obtained from 1.7-fold meninges SUVpeak (Dice index 0.85 ± 0.07). SUVmean and total lesion uptake (SUVmeanxlesion volume) showed better correlations with tumor-absorbed doses than SUVmax when determined with the VolGT (respective Pearson correlation coefficients of 0.78, 0.67, and 0.56) or Volopt (0.64, 0.66, and 0.56). CONCLUSION: Accurate definition of pretherapeutic PET volumes is justified since SUVmean-derived values provide the best tumor-absorbed dose predictions in refractory meningioma patients treated by 177Lu-DOTATATE. This study provides a semi-automated segmentation method of pretherapeutic 68Ga-DOTATOC PET volumes to achieve good reproducibility between physicians. CLINICAL RELEVANCE STATEMENT: SUVmean-derived values from pretherapeutic 68Ga-DOTATOC PET are predictive of tumor-absorbed doses in refractory meningiomas treated by 177Lu-DOTATATE, justifying to accurately define pretherapeutic PET volumes. This study provides a semi-automated segmentation of 68Ga-DOTATOC PET images easily applicable in routine. KEY POINTS: • SUVmean-derived values from pretherapeutic 68Ga-DOTATOC PET images provide the best predictive factors of tumor-absorbed doses related to 177Lu-DOTATATE PRRT in refractory meningioma. • A 1.7-fold meninges SUVpeak segmentation method used to determine metabolic tumor volume on pretherapeutic 68Ga-DOTATOC PET images of refractory meningioma treated by 177Lu-DOTATATE is as efficient as the currently routine manual segmentation method and limits inter- and intra-observer variabilities. • This semi-automated method for segmentation of refractory meningioma is easily applicable to routine practice and transferrable across PET centers.


Asunto(s)
Neoplasias Meníngeas , Meningioma , Tumores Neuroendocrinos , Compuestos Organometálicos , Humanos , Meningioma/diagnóstico por imagen , Meningioma/radioterapia , Receptores de Somatostatina/metabolismo , Radioisótopos de Galio , Reproducibilidad de los Resultados , Octreótido/uso terapéutico , Tomografía de Emisión de Positrones , Neoplasias Meníngeas/diagnóstico por imagen , Neoplasias Meníngeas/radioterapia , Compuestos Organometálicos/uso terapéutico , Tumores Neuroendocrinos/patología
6.
J Nucl Cardiol ; 30(3): 1202-1209, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36289164

RESUMEN

BACKGROUND: This study assesses a first-line left ventricular ejection fraction (LVEF) monitoring provided by an ultra-low-dose equilibrium radionuclide angiography (ERNA) in breast cancer women treated with potentially cardiotoxic drugs and analyzes patient outcome based on the ERNA results. METHODS: Breast cancer women treated with anthracyclines, followed or not by trastuzumab, were monitored using ERNA with a high-sensitivity CZT-camera. Calibrated LVEF measurements were obtained with an almost threefold reduction of radiation doses and 10-min recording times. RESULTS: During a mean 24 ± 6 months follow-up, 552 ERNAs with a mean effective dose of 2.3 ± 0.6 mSv were performed in 195 women, among whom 22 (11%) presented both ERNA criteria of cardiotoxicity (LVEF < 50% and > 10% drop from baseline; Tox + group), 35 (18%) only one criterion (Tox ± group), and 138 (71%) neither (Tox - group). This ERNA-based classification correlated with trastuzumab-anthracycline treatment (p = 0.001), prior cardiovascular disease (p = 0.018), and cardiac outcome, with a 30-month survival with no cardiotoxicity-driven drug regimen changes of 97 ± 2% in Tox -, 60 ± 13% in Tox ± and 36 ± 13% in Tox + (p < 0.001) groups. CONCLUSION: First-line detection of breast cancer therapy-related cardiotoxicity by ultra-low-dose ERNA provides consistent results, confirming the excellent cardiac outcome for the greatest majority of women with no ERNA cardiotoxicity criteria.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/tratamiento farmacológico , Volumen Sistólico , Imagen de Acumulación Sanguínea de Compuerta , Función Ventricular Izquierda , Trastuzumab/uso terapéutico , Cardiotoxicidad , Antibióticos Antineoplásicos , Antraciclinas/uso terapéutico
7.
J Nucl Cardiol ; 30(3): 1043-1049, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36123566

RESUMEN

Somatostatin receptors are overexpressed by inflammatory cells but not by cardiac cells, under normal conditions. This study assesses the detection of acute myocarditis by the ECG-triggered digital-PET imaging of somatostatin receptors (68Ga-DOTATOC-PET), as compared to Cardiac Magnetic Resonance (CMR) imaging, which is the reference diagnostic method in this setting. METHODS: Fourteen CMR-defined acute myocarditis patients had a first 15-minutes ECG-triggered 68Ga-DOTATOC PET recording, 4.4 ± 3.0 days from peak troponin, and 10 had a second 4.3 ± 0.3 months later. Myocardial/blood SUVmax ratio was analyzed relative to the normal upper limit of 2.18, which had been previously determined from oncology 68Ga-DOTATOC-PET recordings of patients with a similar age range as the myocarditis patients. RESULTS: An increased myocardial 68Ga-DOTATOC uptake relative to blood activity was invariably observed during the acute phase. SUVmax ratio exceeded 2.18 in all patients during the acute phase but also in 3/10 patients at 4-months, at a time when there were no more signs of active inflammation on CMR. A residual myocardial 68Ga-DOTATOC uptake was still observed on all gated-PET cine loops at 4-months. CONCLUSION: These preliminary results suggest that 68Ga-DOTATOC ECG-triggered digital-PET may be as sensitive as CMR at detecting myocarditis during the acute phase and more sensitive at later stages.


Asunto(s)
Miocarditis , Compuestos Organometálicos , Humanos , Receptores de Somatostatina , Radioisótopos de Galio , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Electrocardiografía
8.
Eur J Nucl Med Mol Imaging ; 49(4): 1223-1231, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34655307

RESUMEN

PURPOSE: Our study assesses the routine reporting of exercise ischemia using very low-dose exercise-first myocardial perfusion SPECT in a large number of patients and under real-life conditions, by evaluating correlations with the subsequent routine reporting of coronary stenosis by angiography and with factors that predict ischemia. METHODS: Data from 13,126 routine exercise MPI reports, from 11,952 patients (31% women), using very low doses of sestamibi and a high-sensitivity cardiac CZT camera, were extracted to assess the reporting of significant MPI-ischemia (> 1 left ventricular segment), to determine the MPI normalcy rate in a group with < 5% pretest probability of coronary artery disease (CAD) (n = 378), and to assess the ability of MPI to predict a > 50% coronary stenosis in patients with available coronary angiography reports in the 3 months after the MPI (n = 713). RESULTS: The median effective patient dose was 2.51 [IQR: 1.00-4.71] mSv. The normalcy rate was 98%, and the MPI-ischemia rate was independently predicted by a known CAD, the male gender, obesity, and a < 50% LV ejection fraction, ranging from 29.5% with all these risk factors represented to 1.5% when there were no risk factors. A > 50% coronary stenosis was significantly predicted by MPI-ischemia, less significantly for mild (odds ratio [95% confidence interval]: 1.61 [1.26-1.96]) than for moderate-to-severe MPI-ischemia (4.05 [3.53-4.57]) and was also impacted by having a known CAD (2.17 [1.83-2.51]), by a submaximal exercise test (1.48 [1.15-1.81]) and being ≥ 65 years of age (1.43 [1.11-1.76]). CONCLUSION: Ischemia detected using a very low-dose exercise-first MPI protocol in a large-scale clinical cohort and under real-life routine conditions is a highly significant predictor for the subsequent reporting of coronary stenosis, although this prediction is enhanced by other variables. This weakly irradiating approach is amenable to being repeated at shorter time intervals, in target patient groups with a high probability of MPI-ischemia.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Imagen de Perfusión Miocárdica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Prueba de Esfuerzo/métodos , Femenino , Humanos , Masculino , Imagen de Perfusión Miocárdica/métodos , Perfusión , Tomografía Computarizada de Emisión de Fotón Único/métodos
9.
J Nucl Cardiol ; 29(6): 3256-3262, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35194753

RESUMEN

BACKGROUND: This study aims to determine whether the suppression of myocardial FDG uptake and detection of infectious endocarditis (IE) may be enhanced when FDG-PET is repeated on the next day while maintaining patients on a ketogenic diet in the interim. METHODS: Seventeen patients with definite IE underwent FDG-PET investigations both after a conventional metabolic preparation (> 12-hour fast after a low-carbohydrate evening meal) and a subsequent 12-hour extension of the low-carbohydrate diet followed by an additional > 12-hour fast. RESULTS: Plasma biomarkers showed increased ketogenic metabolism between the two FDG-PET scans. A myocardial FDG uptake persisted on the 1st PET in 9 patients (53%) for whom myocardial FDG uptake decreased significantly on the 2nd PET (SUVmax: 6.05 ± 3.25 vs 4.32 ± 3.47, P = 0.021), resulting in an enhancement in the diagnostic confidence of IE in 6 cases. These enhancements were not documented in the 8 patients exhibiting a total suppression of myocardial FDG uptake on the 1st PET. CONCLUSIONS: Better suppression of myocardial uptake and enhanced detection of IE may be achieved when an FDG-PET, showing an incomplete suppression of the myocardial FDG uptake, is repeated as soon as the next day, while maintaining patients on a ketogenic diet in the interim.


Asunto(s)
Dieta Cetogénica , Endocarditis , Humanos , Fluorodesoxiglucosa F18 , Radiofármacos , Tomografía de Emisión de Positrones , Endocarditis/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones
10.
Eur J Nucl Med Mol Imaging ; 48(8): 2525-2530, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33420611

RESUMEN

BACKGROUND: This study aimed to analyze the rates of tracheobronchitis signs observed on the ventilation scans of COVID-19 patients with shortness of breath, with comparisons to a non-COVID population. METHODS: Lung scintigraphy was collected in 10 such COVID patients, as well as from a non-COVID population investigated outside the epidemic wave period, on a CZT-SPECT/CT system, with ventilation images recorded with 99mTc-labeled Technegas® and perfusion images with 99mTc-labeled albumin macroaggregates. RESULTS: A diffuse tracheobronchial uptake was observed on the ventilation scans from 3 COVID patients (30%), whereas this rate was 3% (3/90) in the non-COVID group (P = 0.013). These 3 patients had no laryngeal extension of Technegas® uptake and limited parenchymal lung abnormalities. Follow-up scintigraphy demonstrated the withdrawal of tracheobronchitis signs in two cases, and the advent of a severe pulmonary embolism in one. CONCLUSION: Signs of tracheobronchitis may constitute the principal finding on lung SPECT/CT images of COVID-19 patients with shortness of breath.


Asunto(s)
COVID-19 , Humanos , Pulmón , SARS-CoV-2 , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X
11.
Eur J Nucl Med Mol Imaging ; 48(1): 282-286, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32808079

RESUMEN

PURPOSE: CT signs that are evocative of lung COVID-19 infections have been extensively described, whereas 18F-FDG-PET signs have not. Our current study aimed to identify specific COVID-19 18F-FDG-PET signs in patients that were (i) suspected to have a lung infection based on 18F-FDG-PET/CT recorded during the COVID-19 outbreak and (ii) whose COVID-19 diagnosis was definitely established or excluded by appropriate viral testing. METHODS: Twenty-two consecutive patients referred for routine 18F-FDG-PET/CT examinations during the COVID-19 outbreak (March 25th to May 15th 2020) and for whom CT slices were evocative of a lung infection were included in the study. All patients had undergone a SARS-COV-2 diagnostic test to confirm COVID-19 infection (positivity was based on molecular and/or serological tests) or exclude it (negativity of at least the serological test). RESULTS: Eleven patients were confirmed to be affected by COVID-19 (COVID+), whereas the other eleven patients were not (COVID-) and were predominantly suspected of having bacterial pneumonia. CT abnormalities were not significantly different between COVID+ and COVID- groups, although trends toward larger CT abnormalities (p = 0.16) and lower rates of consolidation patterns (0.09) were observed in the COVID+ group. The maximal standardized uptake values (SUVmax) of lung areas with CT abnormalities were however significantly lower in the COVID+ than the COVID- group (3.7 ± 1.9 vs. 6.9 ± 4.1, p = 0.03), with the highest SUVmax consistently not associated with COVID-19. CONCLUSION: Among CT abnormalities evocative of lung infection, those related to COVID-19 are associated with a more limited 18F-FDG uptake. This observation may help improve our ability to detect COVID-19 patients.


Asunto(s)
COVID-19/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , Prueba de Ácido Nucleico para COVID-19 , Prueba Serológica para COVID-19 , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas
12.
Eur J Nucl Med Mol Imaging ; 47(6): 1381-1390, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31529264

RESUMEN

PURPOSE: 18F-FDopa PET imaging of gliomas is routinely interpreted with standardized uptake value (SUV)-derived indices. This study aimed to determine the added value of dynamic 18F-FDopa PET parameters for predicting the molecular features of newly diagnosed gliomas. METHODS: We retrospectively included 58 patients having undergone an 18F-FDopa PET for establishing the initial diagnosis of gliomas, whose molecular features were additionally characterized according to the WHO 2016 classification. Dynamic parameters, involving time-to-peak (TTP) values and curve slopes, were tested for the prediction of glioma types in addition to current static parameters, i.e., tumor-to-normal brain or tumor-to-striatum SUV ratios and metabolic tumor volume (MTV). RESULTS: There were 21 IDH mutant without 1p/19q co-deletion (IDH+/1p19q-) gliomas, 16 IDH mutants with 1p/19q co-deletion (IDH+/1p19q+) gliomas, and 21 IDH wildtype (IDH-) gliomas. Dynamic parameters enabled differentiating the gliomas according to these molecular features, whereas static parameters did not. In particular, a longer TTP was the single best independent predictor for identifying (1) IDH mutation status (area under the curve (AUC) of 0.789, global accuracy of 74% for the criterion of a TTP ≥ 5.4 min) and (2) 1p/19q co-deletion status (AUC of 0.679, global accuracy of 69% for the criterion of a TTP ≥ 6.9 min). Moreover, the TTP from IDH- gliomas was significantly shorter than those from both IDH+/1p19q- and IDH+/1p19q+ (p ≤ 0.007). CONCLUSION: Prediction of the molecular features of newly diagnosed gliomas with 18F-FDopa PET and especially of the presence or not of an IDH mutation, may be obtained with dynamic but not with current static uptake parameters.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/genética , Glioma/diagnóstico por imagen , Glioma/genética , Humanos , Isocitrato Deshidrogenasa/genética , Mutación , Tomografía de Emisión de Positrones , Estudios Retrospectivos
13.
J Nucl Cardiol ; 27(3): 755-768, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-30574676

RESUMEN

BACKGROUND: The aim of this study was to compare the diagnostic performances for the detection of myocardial ischemia of 82-Rb-PET-MPS and 99m-Tc-SPECT-MPS in overweight individuals and women. METHODS AND RESULTS: Men with BMI ≥ 25 and women referred for MPS were considered for inclusion. All individuals underwent 99m-Tc-SPECT-MPS with CZT cameras and 82-Rb-PET-MPS in 3D-mode. Individuals with at least one positive MPS were referred for coronary angiography (CA) with FFR measurements. A criterion for positivity was a composite endpoint including significant stenosis on CA or, in the absence of CA, the occurrence of acute coronary event during the following year. 313 patients (46% women) with mean BMI of 31.8 ± 6.5 were included. Sensitivity for the detection of myocardial ischemia was higher with 82-Rb-PET-MPS compared with 99m-Tc-SPECT-MPS (85% vs. 57%, P < .05); specificity was equally high with both imaging techniques (93% vs. 94%, P > .05). 82-Rb-PET allowed for a more accurate detection of patients with a high-risk coronary artery disease (HR-CAD) than 99m-Tc-SPECT-MPS (AUC = 0.86 vs. 0.75, respectively; P = .04). CONCLUSIONS: In women and overweight individuals, 82-Rb-PET-MPS provides higher sensitivity for the detection of myocardial ischemia than 99m-Tc-SPECT-MPS thanks to a better image quality and an improved detection of HR-CAD.


Asunto(s)
Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Sobrepeso/complicaciones , Sobrepeso/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Rubidio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Área Bajo la Curva , Índice de Masa Corporal , Cadmio , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Telurio , Zinc
15.
J Nucl Cardiol ; 26(4): 1313-1322, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-29327252

RESUMEN

This phantom-based study was aimed to determine whether cardiac CZT-cameras, which provide an enhanced spatial resolution and image contrast compared to Anger cameras, are similarly affected by small cardiac motions. Translations of a left ventricular (LV) insert at half-SPECT acquisitions through six possible orthogonal directions and with 5- or 10-mm amplitude were simulated on the Discovery NM-530c and DSPECT CZT-cameras and on an Anger Symbia T2 camera equipped with an astigmatic (IQ.SPECT) or conventional parallel-hole collimator (Conv.SPECT). SPECT images were initially reconstructed as currently recommended for clinical routine. The heterogeneity in recorded activity from the 17 LV segments gradually increased between baseline and motions simulated at 5- and 10-mm amplitudes with all cameras, although being higher for Anger- than CZT-cameras at each step and resulting in a higher mean number of artifactual abnormal segments (at 10-mm amplitude, Conv.SPECT: 3.7; IQ.SPECT: 1.8, Discovery: 0.7, DSPECT: 0). However, this vulnerability to motion was markedly (1) decreased for Conv.SPECT reconstructed without the recommended Resolution Recovery algorithm and (2) increased for DSPECT reconstructed without the recommended cardiac model. CZT-cameras and especially the DSPECT appear less vulnerable to small cardiac motions than Anger-cameras although these differences are strongly dependent on reconstruction parameters.


Asunto(s)
Corazón/diagnóstico por imagen , Movimiento (Física) , Imagen de Perfusión Miocárdica/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Artefactos , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen , Reproducibilidad de los Resultados
16.
J Nucl Cardiol ; 26(5): 1539-1549, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30815836

RESUMEN

PURPOSE: To determine whether the left ventricular ejection fractions (EFs), measured on a high-sensitivity CZT single photon emission computed tomography (SPECT)-camera with a 70% reduction in recording times and a prevention of EF overestimation through an additional count-calibration, are concordant with reference EF from planar radionuclide angiography (2D-RNA). METHODS: An additional 10-minute CZT-SPECT recording was performed in patients referred to 2D-RNA for cardiomyopathy (n = 23) or chemotherapy monitoring (n = 50) with an in vivo red blood cell labeling with 850 MBq [Formula: see text]. The EF, obtained from CZT-SPECT with 100% (SPECT100) or 30% (SPECT30) projection times and with a SPECT-count calibration on the 2D-RNA counts of corresponding cavity volumes, were compared to EF from 2D-RNA. RESULTS: Strong and equivalent relationships were documented between the EF from 2D-RNA and the calibrated EF from SPECT100 (y = 0.89x + 6.62; R2 = 0.87) and SPECT30 (y = 0.87x + 8.40; R2 = 0.85), and the mean EF from SPECT100 (54% ± 15%) and SPECT30 (53% ± 16%) were close to that from 2D-RNA (55% ± 15%). However, upward shifts in these mean values were documented in the absence of count calibration for both SPECT100 (60% ± 18%) and SPECT30 (60% ± 18%). CONCLUSION: Left ventricular EF may be determined on a high-sensitivity CZT-camera, a 70% reduction in injected activities, and an additional count-calibration for further enhancing the concordance with 2D-RNA values.


Asunto(s)
Angiografía , Cardiomiopatías/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Neoplasias/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Antineoplásicos/uso terapéutico , Cadmio , Calibración , Simulación por Computador , Eritrocitos/efectos de los fármacos , Femenino , Cámaras gamma , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/tratamiento farmacológico , Estudios Prospectivos , Angiografía por Radionúclidos , Volumen Sistólico , Telurio , Función Ventricular Izquierda , Zinc
17.
J Nucl Cardiol ; 25(1): 249-256, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27677613

RESUMEN

PURPOSE: Gamma-cameras, with Cadmium-Zinc-Telluride (CZT) detectors, allow to perform myocardial perfusion imaging (MPI) with limited injected activities and recorded times. This study aimed at determining whether the routine assessment of left ventricular (LV) function with such limited counts protocols compares well with reference values from cardiac MRI. METHODS: The study included patients who have undergone cardiac MRI and an MPI routinely planned on a CZT camera with a low-dose protocol (120 MBq of Sestamibi for stress and 360 MBq at rest for 75 kg body weight), while targeting the recording of only 500 myocardial kcounts in order to limit the recording times (<10 minutes for stress, <4 minutes for rest). SPECT images were reconstructed with a method maintaining rather high spatial (8 mm) and temporal (16 frames/cycle) resolutions. RESULTS: Seventy-six patients were included, and mean effective dose was 3.5 ± 1.7 mSv for the total MPI protocol. Correlations between CZT-SPECT and MRI were good to excellent for ejection fraction (r 2 = 0.77), end-diastolic (r 2 = 0.88) and end-systolic (r 2 = 0.93) volumes, and the analysis of segmental contractility correlated well between the two techniques (kappa score = 0.72 ± 0.02). CONCLUSION: LV function, assessed on a CZT camera with low injected activities and limited recording times, correlates well with the reference assessment from cardiac MRI.


Asunto(s)
Cadmio , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica , Telurio , Tomografía Computarizada de Emisión de Fotón Único , Función Ventricular Izquierda , Zinc , Anciano , Peso Corporal , Femenino , Cámaras gamma , Corazón/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Dosis de Radiación , Radiofármacos , Estudios Retrospectivos , Sístole , Tecnecio Tc 99m Sestamibi , Factores de Tiempo
18.
J Nucl Cardiol ; 25(6): 2016-2023, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-28512723

RESUMEN

PURPOSE OF THE REPORT: This study aimed at assessing an original low-dose dual-isotope procedure in which the abnormal stress Tc-99m Sestamibi SPECT is followed by rest Tl-201 SPECT, along with a head-to-head comparison with a single-isotope procedure. METHODS AND RESULTS: One hundred two patients, referred for a low-dose stress-SPECT with Sestamibi (123 ± 20 MBq) on a CZT camera and for whom a rest Sestamibi SPECT was warranted, had an additional Tl-201 rest-SPECT (52 ± 5 MBq) between stress and rest Sestamibi SPECT recordings. Tl-201 images were processed for spill-over and scatter corrections, and uptake differences with stress Sestamibi SPECT were analyzed: (1) for rest acquisitions from Tl-201 (dual-isotope procedure) and from Sestamibi (single-isotope procedure) and (2) in segments for which a diagnosis of ischemia, infarct, or normal perfusion was achieved. Mean effective dose was 8.3 mSv for dual-isotope but would decrease to 5.7 mSv for an expected rate of 37% of patients for whom rest-SPECT is not warranted. After a further background correction of Tl-201 images, the rest-stress difference in myocardial uptake was equivalent between dual- and single-procedures for identifying ischemic segments (respective areas-under-curves: 0.83 ± 0.03 and 0.81 ± 0.03). CONCLUSION: This original dual-isotope procedure provides acceptable radiation doses and consistent results, as compared with conventional single-isotope.


Asunto(s)
Imagen de Perfusión Miocárdica/métodos , Radiofármacos , Tecnecio Tc 99m Sestamibi , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Cadmio , Humanos , Dosis de Radiación , Telurio , Zinc
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA