Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 25(9): 985-989, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24758374

RESUMEN

BACKGROUND: Whether gender differences exist in procedure-related adverse events following cardiac resynchronization therapy (CRT-D) implantation is unknown. We investigated the type and frequency of procedure-related adverse events among those enrolled in MADIT-CRT and identified clinical predictors for gender-specific events. METHODS: We compared differences in the rate of procedure-related adverse events by gender (444 females and 1,346 males) that occurred ≤30 days after the index procedure in the implantable cardioverter defibrillator (ICD) and CRT-D groups. Eight types of major adverse events were identified, defined as procedure-related complications deemed potentially life-threatening. Best subset regression analysis (P < 0.10) was performed to identify baseline clinical factors associated with procedure-related adverse events that differed by gender. RESULTS: Women randomized to CRT-D received a greater reduction in the risk of heart failure or death versus men (P < 0.001). Women were twice as likely as men to experience a major procedure-related adverse event (6.3% vs. 2.7%; P < 0.001), including pneumothorax/hemothorax (3% vs. 1%; P < 0.001). Women were more likely to experience a major adverse event related to CRT-D than ICD implantation (7.7% vs. 2.9%; P = 0.018). Clinical predictors of major adverse events in females were smaller body mass index (BMI), elevated blood urea nitrogen, and elevated creatinine. The main predictor for pneumothorax/hemothorax was reduced BMI for women and men. CONCLUSION: Women demonstrate greater clinical benefit from CRT than men but are more likely to experience adverse procedure-related events within the first 30 days after device implantation. A smaller BMI seems to be a major factor associated with pneumothorax/hemothorax in both females and males.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Distribución por Sexo , Factores Sexuales , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA