Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 180
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Cell ; 186(18): 3882-3902.e24, 2023 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-37597510

RESUMEN

Inflammation can trigger lasting phenotypes in immune and non-immune cells. Whether and how human infections and associated inflammation can form innate immune memory in hematopoietic stem and progenitor cells (HSPC) has remained unclear. We found that circulating HSPC, enriched from peripheral blood, captured the diversity of bone marrow HSPC, enabling investigation of their epigenomic reprogramming following coronavirus disease 2019 (COVID-19). Alterations in innate immune phenotypes and epigenetic programs of HSPC persisted for months to 1 year following severe COVID-19 and were associated with distinct transcription factor (TF) activities, altered regulation of inflammatory programs, and durable increases in myelopoiesis. HSPC epigenomic alterations were conveyed, through differentiation, to progeny innate immune cells. Early activity of IL-6 contributed to these persistent phenotypes in human COVID-19 and a mouse coronavirus infection model. Epigenetic reprogramming of HSPC may underlie altered immune function following infection and be broadly relevant, especially for millions of COVID-19 survivors.


Asunto(s)
COVID-19 , Memoria Epigenética , Síndrome Post Agudo de COVID-19 , Animales , Humanos , Ratones , Diferenciación Celular , COVID-19/inmunología , Modelos Animales de Enfermedad , Células Madre Hematopoyéticas , Inflamación/genética , Inmunidad Entrenada , Monocitos/inmunología , Síndrome Post Agudo de COVID-19/genética , Síndrome Post Agudo de COVID-19/inmunología , Síndrome Post Agudo de COVID-19/patología
2.
Cell ; 185(2): 266-282.e15, 2022 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-35026153

RESUMEN

HIV-1-infected cells that persist despite antiretroviral therapy (ART) are frequently considered "transcriptionally silent," but active viral gene expression may occur in some cells, challenging the concept of viral latency. Applying an assay for profiling the transcriptional activity and the chromosomal locations of individual proviruses, we describe a global genomic and epigenetic map of transcriptionally active and silent proviral species and evaluate their longitudinal evolution in persons receiving suppressive ART. Using genome-wide epigenetic reference data, we show that proviral transcriptional activity is associated with activating epigenetic chromatin features in linear proximity of integration sites and in their inter- and intrachromosomal contact regions. Transcriptionally active proviruses were actively selected against during prolonged ART; however, this pattern was violated by large clones of virally infected cells that may outcompete negative selection forces through elevated intrinsic proliferative activity. Our results suggest that transcriptionally active proviruses are dynamically evolving under selection pressure by host factors.


Asunto(s)
VIH-1/genética , Provirus/genética , Transcripción Genética , Anciano , Secuencia de Bases , Evolución Biológica , Cromatina/metabolismo , Células Clonales , ADN Viral/genética , Epigénesis Genética/efectos de los fármacos , Femenino , Humanos , Ionomicina/farmacología , Masculino , Persona de Mediana Edad , Filogenia , Provirus/efectos de los fármacos , ARN Viral/genética , Acetato de Tetradecanoilforbol/farmacología , Transcripción Genética/efectos de los fármacos , Integración Viral/genética , Latencia del Virus/efectos de los fármacos , Latencia del Virus/genética
3.
Cell ; 183(1): 143-157.e13, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32877699

RESUMEN

Humoral responses in coronavirus disease 2019 (COVID-19) are often of limited durability, as seen with other human coronavirus epidemics. To address the underlying etiology, we examined post mortem thoracic lymph nodes and spleens in acute SARS-CoV-2 infection and observed the absence of germinal centers and a striking reduction in Bcl-6+ germinal center B cells but preservation of AID+ B cells. Absence of germinal centers correlated with an early specific block in Bcl-6+ TFH cell differentiation together with an increase in T-bet+ TH1 cells and aberrant extra-follicular TNF-α accumulation. Parallel peripheral blood studies revealed loss of transitional and follicular B cells in severe disease and accumulation of SARS-CoV-2-specific "disease-related" B cell populations. These data identify defective Bcl-6+ TFH cell generation and dysregulated humoral immune induction early in COVID-19 disease, providing a mechanistic explanation for the limited durability of antibody responses in coronavirus infections, and suggest that achieving herd immunity through natural infection may be difficult.


Asunto(s)
Infecciones por Coronavirus/inmunología , Centro Germinal/inmunología , Neumonía Viral/inmunología , Linfocitos T Colaboradores-Inductores/inmunología , Anciano , Anciano de 80 o más Años , Linfocitos B/inmunología , COVID-19 , Femenino , Centro Germinal/patología , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Proteínas Proto-Oncogénicas c-bcl-6/genética , Proteínas Proto-Oncogénicas c-bcl-6/metabolismo , Bazo/inmunología , Bazo/patología , Factor de Necrosis Tumoral alfa/metabolismo
4.
Nature ; 585(7824): 261-267, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32848246

RESUMEN

Sustained, drug-free control of HIV-1 replication is naturally achieved in less than 0.5% of infected individuals (here termed 'elite controllers'), despite the presence of a replication-competent viral reservoir1. Inducing such an ability to spontaneously maintain undetectable plasma viraemia is a major objective of HIV-1 cure research, but the characteristics of proviral reservoirs in elite controllers remain to be determined. Here, using next-generation sequencing of near-full-length single HIV-1 genomes and corresponding chromosomal integration sites, we show that the proviral reservoirs of elite controllers frequently consist of oligoclonal to near-monoclonal clusters of intact proviral sequences. In contrast to individuals treated with long-term antiretroviral therapy, intact proviral sequences from elite controllers were integrated at highly distinct sites in the human genome and were preferentially located in centromeric satellite DNA or in Krüppel-associated box domain-containing zinc finger genes on chromosome 19, both of which are associated with heterochromatin features. Moreover, the integration sites of intact proviral sequences from elite controllers showed an increased distance to transcriptional start sites and accessible chromatin of the host genome and were enriched in repressive chromatin marks. These data suggest that a distinct configuration of the proviral reservoir represents a structural correlate of natural viral control, and that the quality, rather than the quantity, of viral reservoirs can be an important distinguishing feature for a functional cure of HIV-1 infection. Moreover, in one elite controller, we were unable to detect intact proviral sequences despite analysing more than 1.5 billion peripheral blood mononuclear cells, which raises the possibility that a sterilizing cure of HIV-1 infection, which has previously been observed only following allogeneic haematopoietic stem cell transplantation2,3, may be feasible in rare instances.


Asunto(s)
Silenciador del Gen , Infecciones por VIH/genética , Infecciones por VIH/virología , VIH-1/genética , Heterocromatina/genética , Provirus/genética , Integración Viral/genética , Latencia del Virus/genética , Adulto , Anciano , Centrómero/genética , Cromosomas Humanos Par 19/genética , ADN Satélite/genética , Femenino , Genoma Viral/genética , Infecciones por VIH/sangre , VIH-1/aislamiento & purificación , Heterocromatina/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Provirus/aislamiento & purificación , Proteínas Represoras/genética , Sitio de Iniciación de la Transcripción
5.
Circulation ; 147(21): 1568-1578, 2023 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-36960730

RESUMEN

BACKGROUND: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. METHODS: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. RESULTS: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation (P<0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P=0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. CONCLUSIONS: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04420078.


Asunto(s)
Síndrome de Brugada , Ablación por Catéter , Desfibriladores Implantables , Humanos , Masculino , Adulto , Fibrilación Ventricular , Electrocardiografía/métodos , Ventrículos Cardíacos , Síndrome de Brugada/cirugía , Síndrome de Brugada/complicaciones , Desfibriladores Implantables/efectos adversos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de Registros
6.
Pacing Clin Electrophysiol ; 47(3): 448-454, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38291877

RESUMEN

BACKGROUND: Application of electrocautery to a J-wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique. METHODS: Two hundred consecutive patients were randomized in a 1:1 fashion to either the ICE-guided electrified J-wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, "coag" mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time. RESULTS: All patients complete the procedure safely. The electrified J-wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra-atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J-wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra-atrial shunt (4.3% vs. 6%, p = .654) during the 3-month's follow up. CONCLUSION: Using an electrified J-wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non-fluoroscopy AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/cirugía , Fibrilación Atrial/cirugía , Estudios Prospectivos , Punciones/métodos , Ablación por Catéter/métodos , Ecocardiografía , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 47(1): 167-171, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38041413

RESUMEN

BACKGROUND: Atrial esophageal fistula (AEF) is a lethal complication that can occur post atrial fibrillation (AF) ablation. Esophageal injury (EI) is likely to be the initial lesion leading to AEF. Endoscopic examination is the gold standard for a diagnosis of EI but extensive endoscopic screening is invasive and costly. This study was conducted to determine whether fecal calprotectin (Fcal), a marker of inflammation throughout the intestinal tract, may be associated with the existence of esophageal injury. METHODS: This diagnostic study was conducted in a cohort of 166 patients with symptomatic AF undergoing radiofrequency catheter ablation from May 2020 to June 2021. Fcal tests were performed 1-7 days after ablation. All patients underwent endoscopic ultrasonography 1 or 2 days after ablation. RESULTS: The levels of Fcal were significantly different between the EI and non-EI groups (404.9 µg/g (IQR 129.6-723.6) vs. 40.4 µg/g (IQR 15.0-246.2), p < .001). Analysis of ROC curves revealed that a Fcal level of 125 µg/g might be the optimal cut-off value for a diagnosis of EI, giving a 78.8% sensitivity and a 65.4% specificity. The negative predictive value of Fcal was 100% for ulcerated EI. CONCLUSIONS: The level of Fcal is associated with EI post AF catheter ablation. 125 µg/g might be the optimal cut-off value for a diagnosis of EI. Negative Fcal could predict the absence of ulcerated EI, which could be considered a precursor to AEF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula Esofágica , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Complejo de Antígeno L1 de Leucocito , Atrios Cardíacos , Fístula Esofágica/etiología , Ablación por Catéter/efectos adversos
8.
J Appl Toxicol ; 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38527925

RESUMEN

Centella asiatica (L.) Urban is a famous Chinese traditional medicine, which is widely used for treating various chronic inflammatory diseases. Although there are reports that Centella total glycosides exhibit heart-protective properties, our previous experiment showed that it has cardiac toxic effects in zebrafish. The components of Centella total glycosides are complex, so we recommend further research to determine their key components and mechanisms. In this study, sample quantification was done using liquid chromatography-tandem mass spectrometry. The cardiotoxicity of Centella total glycosides, asiaticoside, madecassoside, asiatic acid, and madecassic acid was evaluated using zebrafish and cell models. The zebrafish oxidative stress model and myocarditis model were used to explore further the mechanisms through which cardiotoxicity is achieved. Asiatic acid and madecassic acid caused zebrafish cardiotoxicity and H9C2 cell death. However, no toxicity effects were observed for asiaticoside and madecassoside in zebrafish, until the solution was saturated. The results from the cell model study showed that asiatic acid and madecassic acid changed the expression of apoptosis-related genes in myocardial cells. In the zebrafish model, high concentrations of these components raised the levels of induced systemic inflammation, neutrophils gathered in the heart, and oxidative stress injury. Asiatic acid and madecassic acid are the main components causing cardiotoxicity in zebrafish. This may be due to enhanced inflammation and reactive oxygen species injury, which causes myocardial cell apoptosis, which further leads to cardiac toxicity.

9.
Pak J Med Sci ; 40(3Part-II): 297-302, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38356797

RESUMEN

Objective: To analyze the efficacy of single-channel percutaneous endoscopic lumbar discectomy (PELD) and conventional open surgery in the treatment of lumbar disc herniation (LDH). Methods: This is a retrospective study. A total of 66 patients with LDH admitted to Tianjin Medical University from June 2017 to June 2018 were divided into two groups: the observation group (single-channel PELD) and the control group (posterior lumbar interbody fusion), with 33 cases in each group. The two groups were compared in terms of visual analogue scale(VAS), oswestry disability index (ODI), Japanese Orthopaedic Association Score(JOA), perioperative indicators, clinical efficacy, postoperative complications, changes in inflammatory factors and serum T lymphocyte subsets. Results: The operation time, incision length, intraoperative blood loss, time in bed, hospital stay in the observation group were all lower than those in the control group. At 7d after treatment, the improvement of ODI, VAS and JOA in the observation group were better than that in the control group. At the last follow-up, there was no significant difference in Cobb angle and lumbar lordosis angle between the two groups. The levels of serum IL-1, IL-6 and TNF-α in the observation group were lower than those in the control group. The degree of reduction of serum CD3+ and CD4+ in the observation group were higher than those in the control group. And the level of elevation of CD8+ in the observation group was lower than that in the control group. Moreover, there was no significant difference in CD4+/CD8+ level between the two groups. The excellent rate of surgical results in the observation group was higher than that in the control group. Complications occurred in both groups, with no significant difference between the two groups. Conclusions: Single-channel PELD can achieve superior clinical efficacy over conventional open surgery in the treatment of LDH.

10.
Circulation ; 145(25): 1839-1849, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35507499

RESUMEN

BACKGROUND: Catheter ablation as first-line therapy for ventricular tachycardia (VT) at the time of implantable cardioverter defibrillator (ICD) implantation has not been adopted into clinical guidelines. Also, there is an unmet clinical need to prospectively examine the role of VT ablation in patients with nonischemic cardiomyopathy, an increasingly prevalent population that is referred for advanced therapies globally. METHODS: We conducted an international, multicenter, randomized controlled trial enrolling 180 patients with cardiomyopathy and monomorphic VT with an indication for ICD implantation to assess the role of early, first-line ablation therapy. A total of 121 patients were randomly assigned (1:1) to ablation plus an ICD versus conventional medical therapy plus an ICD. Patients who refused ICD (n=47) were followed in a prospective registry after stand-alone ablation treatment. The primary outcome was a composite end point of VT recurrence, cardiovascular hospitalization, or death. RESULTS: Randomly assigned patients had a mean age of 55 years (interquartile range, 46-64) and left ventricular ejection fraction of 40% (interquartile range, 30%-49%); 81% were male. The underlying heart disease was ischemic cardiomyopathy in 35%, nonischemic cardiomyopathy in 30%, and arrhythmogenic cardiomyopathy in 35%. Ablation was performed a median of 2 days before ICD implantation (interquartile range, 5 days before to 14 days after). At 31 months, the primary outcome occurred in 49.3% of the ablation group and 65.5% in the control group (hazard ratio, 0.58 [95% CI, 0.35-0.96]; P=0.04). The observed difference was driven by a reduction in VT recurrence in the ablation arm (hazard ratio, 0.51 [95%CI, 0.29-0.90]; P=0.02). A statistically significant reduction in both ICD shocks (10.0% versus 24.6%; P=0.03) and antitachycardia pacing (16.2% versus 32.8%; P=0.04) was observed in patients who underwent ablation compared with control. No differences in cardiovascular hospitalization (32.0% versus. 33.7%; hazard ratio, 0.82 [95% CI, 0.43-1.56]; P=0.55) or mortality (8.9% versus 8.8%; hazard ratio, 1.40 [95% CI, 0.38-5.22]; P=0.62]) were observed. Ablation-related complications occurred in 8.3% of patients. CONCLUSIONS: Among patients with cardiomyopathy of varied causes, early catheter ablation performed at the time of ICD implantation significantly reduced the composite primary outcome of VT recurrence, cardiovascular hospitalization, or death. These findings were driven by a reduction in ICD therapies. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02848781.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Cardiomiopatías/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda
11.
Am Heart J ; 260: 34-43, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813122

RESUMEN

BACKGROUND: In randomized studies, the strategy of pulmonary vein antral isolation (PVI) plus linear ablation has failed to increase success rates for persistent atrial fibrillation (PeAF) ablation when compared with PVI alone. Peri-mitral reentry related atrial tachycardia due to incomplete linear block is an important cause of clinical failures of a first ablation procedure. Ethanol infusion (EI) into the vein of Marshall (EI-VOM) has been demonstrated to facilitate a durable mitral isthmus linear lesion. OBJECTIVE: This trial is designed to compare arrhythmia-free survival between PVI and an ablation strategy termed upgraded '2C3L' for the ablation of PeAF. STUDY DESIGN: The PROMPT-AF study (clinicaltrials.gov 04497376) is a prospective, multicenter, open-label, randomized trial using a 1:1 parallel-control approach. Patients (n = 498) undergoing their first catheter ablation of PeAF will be randomized to either the upgraded '2C3L' arm or PVI arm in a 1:1 fashion. The upgraded '2C3L' technique is a fixed ablation approach consisting of EI-VOM, bilateral circumferential PVI, and 3 linear ablation lesion sets across the mitral isthmus, left atrial roof, and cavotricuspid isthmus. The follow-up duration is 12 months. The primary end point is freedom from atrial arrhythmias of >30 seconds, without antiarrhythmic drugs, in 12 months after the index ablation procedure (excluding a blanking period of 3 months). CONCLUSIONS: The PROMPT-AF study will evaluate the efficacy of the fixed '2C3L' approach in conjunction with EI-VOM, compared with PVI alone, in patients with PeAF undergoing de novo ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Estudios Prospectivos , Atrios Cardíacos/cirugía , Etanol , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
12.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38165731

RESUMEN

AIMS: Pulsed-field ablation (PFA) is a promising new ablation modality to treat atrial fibrillation. However, PFA can cause varying degrees of diaphragmatic contraction and dry cough, especially under conscious sedation. This prospective study presents a method to minimize the impact of PFA on diaphragmatic contraction and dry cough during the procedure. METHODS AND RESULTS: Twenty-eight patients underwent PFA for pulmonary vein (PV) and superior vena cava isolation under conscious sedation. Each patient received two groups of ablations in each vein: the control group allowed PFA application during any phase of respiratory cycle, while the test group used respiratory control, delivering PFA energy only at the end of expiration. A rating score system was developed to assess diaphragmatic contraction and dry cough. A total of 1401 control ablations and 4317 test ablations were performed. The test group had significantly lower scores for diaphragmatic contraction (P < 0.01) and dry cough (P < 0.001) in all PVs compared to the control group. The average relative reductions in scores for all PVs were 33-47% for diaphragmatic contraction and 67-83% for dry cough. The percentage of ablations with scores ≧2 for diaphragmatic contraction decreased significantly from 18.5-28.0% in the control group to 0.4-2.6% in the test group (P < 0.001). For dry cough, the percentage decreased from 11.9-43.7% in the control group to 0.7-2.1% in the test group. CONCLUSION: Pulsed-field ablation application at the end of expiration can reduce the severity of diaphragmatic contraction and eliminate moderate and severe dry cough during PV isolation performed under conscious sedation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Vena Cava Superior/cirugía , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Diafragma , Venas Pulmonares/cirugía , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 46(8): 1010-1018, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37377409

RESUMEN

BACKGROUND: Vasovagal syncope (VVS) is one of the most common causes of syncope. Traditional treatment has not achieved satisfactory results. The purpose of this study was to assess the feasibility and efficacy of selective anatomical catheter ablation of left atrial ganglionated plexus (GP) as a therapeutic strategy for the patients of symptomatic VVS. METHODS: A total of 70 patients with at least once recurrent syncopal episode of VVS with a positive head-up tilt test were enrolled. They were divided into GP ablation group and control group. Patients in GP ablation group received anatomical catheter ablation of left superior ganglionated plexus (LSGP) and right anterior ganglionated plexus (RAGP). Patients in the control group were guideline-directed conventional therapy. The primary endpoint was VVS recurrences. The secondary endpoint was the recurrence of syncope and prodrome events. RESULTS: There were no statistical differences in clinical characteristics between the ablation group (n = 35) and the control group (n = 35). Over a follow-up of 12 months, the ablation group had significantly lower syncope recurrence compared with the control group (5.7% vs. 25.7%, p = .02), and the ablation group had significantly lower syncope and prodrome recurrence compared with the control group (11.4% vs. 51.4%, p < .001). In GP ablation, 88.6% of the patients showed significant vagal response during LSGP ablation, and 88.6% of the patients showed significantly increased heart rate during RAGP ablation. CONCLUSIONS: For patients with recurrent VVS, selective anatomical catheter ablation of LSGP and RAGP is superior to conventional therapy in reducing syncope recurrence.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Síncope Vasovagal , Humanos , Síncope Vasovagal/cirugía , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos
14.
Pacing Clin Electrophysiol ; 46(12): 1478-1483, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37943004

RESUMEN

BACKGROUND: Patients with non-valvular atrial fibrillation (NVAF) and previous stroke have a significantly higher risk of stroke recurrence. This study aimed to examine the safety and efficacy of the LAmbre left atrial appendage occlusion device in NVAF patients with a history of stroke. METHODS: We examined 103 consecutive NVAF patients in 11 Chinese medical centers who had a history of stroke or transient ischemic attacks (TIA) and underwent placement of the LAmbre device. Follow-up was conducted 1, 3, 6, and 12 months after the procedure. The primary endpoints were the incidence of new ischemic or hemorrhagic stroke, TIA, systemic embolism, or cardiac death. Secondary endpoints were serious perioperative or device-related complications and cerebral, gastrointestinal, or other bleeding events requiring transfusion of at least 2 units of packed red blood cells. RESULTS: Mean patient age was 67.63 ± 7.14 years; mean CHA2DS2-VASc score was 4.72 ± 1.18 and mean HAS-BLED score was 1.90 ± 1.00. LAmbre device placement was successful in 101 patients (98.05%). Mean follow-up was 12.2 months. Five patients (4.95%) developed a new pericardial effusion after the procedure; none required treatment. Eighty-six patients (85.15%) exhibited no peri-device leak (PDL). However, 13 (12.8%) had a small (0-3 mm) PDL and two (2.3%) had a moderate PDL (3-5 mm). One recurrent stroke occurred during follow-up (1.1%). No other complications occurred. CONCLUSIONS: This multicenter study shows the safety and efficacy of LAmbre left atrial appendage occlusion for NVAF patients with a history of stroke or TIA.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ataque Isquémico Transitorio , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Persona de Mediana Edad , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Accidente Cerebrovascular Isquémico/complicaciones , Apéndice Atrial/cirugía , Ataque Isquémico Transitorio/complicaciones , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Resultado del Tratamiento
15.
Pacing Clin Electrophysiol ; 46(1): 3-10, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36301182

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) technology has been increasingly accepted as an integral part of atrial fibrillation (AF) ablation procedures. It is still unknown whether ICE can routinely replace transesophageal echocardiography (TEE) for routine thrombus screening in non-selective AF patients. OBJECTIVE: To assess whether ICE can routinely replace TEE in screening for left atrial (LA)/left atrial appendage (LAA) thrombus in general patients undergoing catheter ablation for AF. METHODS: A total of 2003 consecutive patients undergoing AF ablation were included. 1155 patients (ICE group) received intra-procedural ICE examination for LA/LAA thrombus screening, while 848 patients (TEE group) received pre-procedure TEE examination. The incidence of thrombus, peri-procedure complications, and hospital efficiency were assessed. RESULTS: The LA and LAA were adequately visualized in all patients. Five patients in the ICE group and 15 patients in the TEE group were found to have LAA thrombus. The incidence of major periprocedural thrombo-embolic events was comparable between two groups (0.2% vs. 0.1%, p = .76), none were due to undetected LA/LAA thrombus. Other major periprocedural complications occurred at similar rates in both groups, while post-procedure fever was less common in the ICE group (12.7% vs. 17.4%, p < .001). Procedure times and hospital length of stay were both shorter in the ICE group (142 min [87-197 min] vs. 150 min [95-205 min], and 3[2-4] day vs. 4[3-5] day, respectively, both p < .001). CONCLUSIONS: ICE can replace TEE for atrial thrombus screening in AF patients undergoing ablation without increased complications. An "ICE replacing TEE" workflow can also reduce the incidence of postoperative fever and improve hospital efficiency.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Cardiopatías , Trombosis , Humanos , Ecocardiografía Transesofágica/métodos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cardiopatías/complicaciones , Trombosis/complicaciones
16.
Pacing Clin Electrophysiol ; 46(9): 1035-1048, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37573146

RESUMEN

Transcatheter radiofrequency ablation has been widely introduced for the treatment of tachyarrhythmias. The demand for catheter ablation continues to grow rapidly as the level of recommendation for catheter ablation. Traditional catheter ablation is performed under the guidance of X-rays. X-rays can help display the heart contour and catheter position, but the radiobiological effects caused by ionizing radiation and the occupational injuries worn caused by medical staff wearing heavy protective equipment cannot be ignored. Three-dimensional mapping system and intracardiac echocardiography can provide detailed anatomical and electrical information during cardiac electrophysiological study and ablation procedure, and can also greatly reduce or avoid the use of X-rays. In recent years, fluoroless catheter ablation technique has been well demonstrated for most arrhythmic diseases. Several centers have reported performing procedures in a purposefully designed fluoroless electrophysiology catheterization laboratory (EP Lab) without fixed digital subtraction angiography equipment. In view of the lack of relevant standardized configurations and operating procedures, this expert task force has written this consensus statement in combination with relevant research and experience from China and abroad, with the aim of providing guidance for hospitals (institutions) and physicians intending to build a fluoroless cardiac EP Lab, implement relevant technologies, promote the standardized construction of the fluoroless cardiac EP Lab.


Asunto(s)
Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Cirugía Asistida por Computador , Humanos , Electrofisiología Cardíaca , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
17.
Neurol Sci ; 44(10): 3545-3556, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37184590

RESUMEN

BACKGROUND: The discovery of skin intranuclear inclusions and GGC repeat expansion of NOTCH2NLC has greatly promoted the diagnosis of neuronal intranuclear inclusion disease (NIID). With highly heterogeneous clinical manifestations, NIID patients tend to be underdiagnosed at early stages. METHODS: This study comprehensively studied clinical manifestations, magnetic resonance imaging (MRI), and peripheral nerve conduction in 24 NIID and 166 other neurodegenerative disease (ND) subjects. The nomogram was plotted using the "rms" package, and the t-distributed stochastic neighbor embedding algorithm was performed. Associations between skin intranuclear inclusions and NOTCH2NLC GGC repeats were further analyzed. RESULTS: The clinical, MRI, and peripheral nerve conduction features seriously overlapped in NIID and ND patients; they were assigned variables according to their frequency and specificity in NIID patients. A nomogram that could distinguish NIID from ND was constructed according to the assigned variables and cutoff values of the above features. The occurrence of skin intranuclear inclusions and NOTCH2NLC GGC repeats ≥ 60 showed 100% consistency, and intranuclear inclusion frequency positively correlated with NOTCH2NLC GGC repeats. A hierarchical diagnostic flowchart for definite NIID was further established. CONCLUSION: We provide a novel nomogram with the potential to realize early identification and update the diagnostic flowchart for definitive diagnosis. Moreover, this is the first study to define the association between skin pathology and NOTCH2NLC genetics in NIID.


Asunto(s)
Enfermedades Neurodegenerativas , Humanos , Enfermedades Neurodegenerativas/diagnóstico por imagen , Enfermedades Neurodegenerativas/genética , Cuerpos de Inclusión Intranucleares/genética , Cuerpos de Inclusión Intranucleares/patología , Imagen por Resonancia Magnética , Piel
18.
Scott Med J ; 68(1): 21-31, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36253715

RESUMEN

BACKGROUND: This study employs machine learning strategy algorithms to screen the optimal gene signature of pulmonary arterial hypertension (PAH) under big data in the medical field. METHODS: The public database Gene Expression Omnibus (GEO) was used to analyze datasets of 32 normal controls and 37 PAH disease samples. The enrichment analysis was performed after selecting the differentially expressed genes. Two machine learning methods, the least absolute shrinkage and selection operator (LASSO) and support vector machine (SVM), were used to identify the candidate genes. The external validation data set further tests the expression level and diagnostic value of candidate diagnostic genes. The diagnostic effectiveness was evaluated by obtaining the receiver operating characteristic curve (ROC). The convolution tool CIBERSORT was used to estimate the composition pattern of the immune cell subtypes and to perform correlation analysis based on the combined training dataset. RESULTS: A total of 564 differentially expressed genes (DEGs) were screened in normal control and pulmonary hypertension samples. The enrichment analysis results were found to be closely related to cardiovascular diseases, inflammatory diseases, and immune-related pathways. The LASSO and SVM algorithms in machine learning used 5 × cross-validation to identify 9 and 7 characteristic genes. The two machine learning algorithms shared Caldesmon 1 (CALD1) and Solute Carrier Family 7 Member 11 (SLC7A11) as genetic signals highly correlated with PAH. The results showed that the area under ROC (AUC) of the specific characteristic diagnostic genes were CALD1 (AUC = 0.924) and SLC7A11 (AUC = 0.962), indicating that the two diagnostic genes have high diagnostic value. CONCLUSION: CALD1 and SLC7A11 can be used as diagnostic markers of PAH to obtain new insights for the further study of the immune mechanism involved in PAH.


Asunto(s)
Enfermedades Cardiovasculares , Hipertensión Arterial Pulmonar , Humanos , Hipertensión Arterial Pulmonar/diagnóstico , Hipertensión Arterial Pulmonar/genética , Máquina de Vectores de Soporte , Algoritmos
19.
Angew Chem Int Ed Engl ; 62(16): e202216605, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-36811516

RESUMEN

A chiral Brønsted acid-catalysed asymmetric hydrophosphinylation of 2-vinylazaarenes by secondary phosphine oxides is described. A variety of P-chiral 2-azaaryl-ethylphosphine oxides are synthesized with high yields and ees, of which both the substituents of phosphines and azaarenes can be flexibly modulated, underscoring an exceptionally broad scope of substrates. These adducts are valuable to asymmetric metal catalysis since the resultant P-chiral tertiary phosphines from the reduction of them are verified as a kind of effective C1 -symmetric chiral 1,5-hybrid P,N-ligands. Importantly, this catalysis platform enables the generic and efficient kinetic resolution of P-chiral secondary phosphine oxides. It thus provides an expedient approach to access the enantiomers of the P-chiral tertiary phosphine oxides derived from asymmetric hydrophosphinylation, further improving the utility of the method.

20.
J Am Chem Soc ; 144(9): 3957-3967, 2022 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-35192764

RESUMEN

The importance of selenium (Se) in biology and health has become increasingly clear. Hydrogen selenide (H2Se), the biologically available and active form of Se, is suggested to be an emerging nitric oxide (NO)-like signaling molecule. Nevertheless, the research on H2Se chemical biology has technique difficulties due to the lack of well-characterized and controllable H2Se donors under physiological conditions, as well as a robust assay for direct H2Se quantification. Motivated by these needs, here, we demonstrate that selenocyclopropenones and selenoamides are tunable donor motifs that release H2Se upon reaction with cysteine (Cys) at pH 7.4 and that structural modifications enable the rate of Cys-mediated H2Se release to be tuned. We monitored the reaction pathways for the H2Se release and confirmed H2Se generation qualitatively using different methods. We further developed a quantitative assay for direct H2Se trapping and quantitation in an aqueous solution, which should also be operative for investigating future H2Se donor motifs. In addition, we demonstrate that arylselenoamide has the capability of Cys-mediated H2Se release in cellular environments. Importantly, mechanistic investigations and density functional theory (DFT) calculations illustrate the plausible pathways of Cys-activated H2Se release from arylselenoamides in detail, which may help understand the mechanistic issues of the H2S release from pharmacologically important arylthioamides. We anticipate that the well-defined chemistries of Cys-activated H2Se donor motifs will be useful for studying Se biology and for development of new H2Se donors and bioconjugate techniques.


Asunto(s)
Sulfuro de Hidrógeno , Selenio , Cisteína , Sulfuro de Hidrógeno/química , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA