Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Radiology ; 271(3): 633-52, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24848958

RESUMEN

Through a marriage of spiral computed tomography (CT) and graphical volumetric image processing, CT angiography was born 20 years ago. Fueled by a series of technical innovations in CT and image processing, over the next 5-15 years, CT angiography toppled conventional angiography, the undisputed diagnostic reference standard for vascular disease for the prior 70 years, as the preferred modality for the diagnosis and characterization of most cardiovascular abnormalities. This review recounts the evolution of CT angiography from its development and early challenges to a maturing modality that has provided unique insights into cardiovascular disease characterization and management. Selected clinical challenges, which include acute aortic syndromes, peripheral vascular disease, aortic stent-graft and transcatheter aortic valve assessment, and coronary artery disease, are presented as contrasting examples of how CT angiography is changing our approach to cardiovascular disease diagnosis and management. Finally, the recently introduced capabilities for multispectral imaging, tissue perfusion imaging, and radiation dose reduction through iterative reconstruction are explored with consideration toward the continued refinement and advancement of CT angiography.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/terapia , Angiografía Coronaria/tendencias , Tomografía Computarizada Espiral/tendencias , Técnicas de Imagen Sincronizada Cardíacas , Angiografía Coronaria/métodos , Humanos , Imagenología Tridimensional , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada Espiral/métodos
2.
Acad Radiol ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060206

RESUMEN

RATIONALE AND OBJECTIVES: Evidence is building in support of the clinical utility of atherosclerotic plaque imaging by computed tomography angiography (CTA). There is increasing organized activity to embrace non-calcified plaque (NCP) as a formally defined biomarker for clinical trials, and high-risk plaque (HRP) for clinical care, as the most relevant measures for the field to advance and worthy of community efforts to validate. Yet the ability to assess the quantitative performance of any given specific solution to make these measurements or classifications is not available. Vendors use differing definitions, assessment metrics, and validation data sets to describe their offerings without clinician users having the capability to make objective assessments of accuracy and precision and how this affects diagnostic confidence. MATERIALS AND METHODS: The QIBA Profile for Atherosclerosis Biomarkers by CTA was created by the Quantitative Imaging Biomarkers Alliance (QIBA) to improve objectivity and decrease the variability of noninvasive plaque phenotyping. The Profile provides claims on the accuracy and precision of plaque measures individually and when combined. RESULTS: Individual plaque morphology measurements are evaluated in terms of bias (accuracy), slope (consistency of the bias across the measurement range, needed for measurements of change), and variability. The multiparametric plaque stability phenotype is evaluated in terms of agreement with expert pathologists. The Profile is intended for a broad audience, including those engaged in discovery science, clinical trials, and patient care. CONCLUSION: This report provides a rationale and overview of the Profile claims and how to comply with the Profile in research and clinical practice. SUMMARY STATEMENT: This article summarizes objective means to validate the analytical performance of non-calcified plaque (NCP), other emerging plaque morphology measurements, and multiparametric histology-defined high-risk plaque (HRP), as outlined in the QIBA Profile for Atherosclerosis Biomarkers by CTA.

3.
Pediatr Cardiol ; 34(3): 518-24, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22956060

RESUMEN

Computed tomographic angiography (CTA) and cardiac catheterization are useful adjuncts to echocardiography for delineating cardiovascular anatomy in pediatric patients. These studies require ionizing radiation, and it is paramount to understand the amount of radiation pediatric patients receive when these tests are performed. Modern dosimetry methods facilitate the conversion of radiation doses of varying units into an effective radiation dose. To compare the effective radiation dose between nongated CTA of the chest and diagnostic cardiac catheterization in pediatric patients. This is a retrospective cohort study of patients of patients who underwent either nongated CTA of the chest or diagnostic cardiac catheterization between July 2009 and April 2010. Fifty patients were included in each group as consecutive samples at a single tertiary care center. An effective radiation dose (mSv) was formulated using conversion factors for each group. The median effective dose (ED) for the CTA group was 0.74 mSv compared with 10.8 mSv for the catheterization group (p < 0.0001). The median ED for children <1 year of age in the CTA group was 0.76 mSv compared with 13.4 mSv for the catheterization group (p < 0.0001). Nongated CTA of the chest exposes children to 15 times less radiation than diagnostic cardiac catheterization. Unless hemodynamic data are necessary, CTA of the chest should be considered in lieu of diagnostic cardiac catheterization in patients with known or presumed cardiac disease who need additional imaging beyond echocardiography.


Asunto(s)
Cateterismo Cardíaco/métodos , Dosis de Radiación , Radiografía Intervencional/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos , Adolescente , Factores de Edad , Angiografía/efectos adversos , Angiografía/métodos , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Estudios de Cohortes , Relación Dosis-Respuesta en la Radiación , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Masculino , Protección Radiológica/métodos , Radiografía Intervencional/métodos , Estudios Retrospectivos , Medición de Riesgo , Tórax/efectos de la radiación , Tomografía Computarizada por Rayos X/métodos
4.
J Biomech ; 151: 111513, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36868983

RESUMEN

Establishing a patient-specific and non-invasive technique to derive blood flow as well as coronary structural information from one single cardiac CT imaging modality. 336 patients with chest pain or ST segment depression on electrocardiogram were retrospectively enrolled. All patients underwent adenosine-stressed dynamic CT myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) in sequence. Relationship between myocardial mass (M) and blood flow (Q), defined as log(Q) = b · log(M) + log(Q0), was explored based on the general allometric scaling law. We used 267 patients to obtain the regression results and found strong linear relationship between M (gram) and Q (mL/min) (b = 0.786, log(Q0) = 0.546, r = 0.704; p < 0.001). We Also found this correlation was applicable for patients with either normal or abnormal myocardial perfusion (p < 0.001). Datasets from the other 69 patients were used to validate this M-Q correlation and found the patient-specific blood flow could be accurately estimated from CCTA compared to that measured from CT-MPI (146.480 ± 39.607 vs 137.967 ± 36.227, r = 0.816, and 146.480 ± 39.607 vs 137.967 ± 36.227, r = 0.817, for the left ventricle region and LAD-subtended region, respectively, all unit in mL/min). In conclusion, we established a technique to provide general and patient-specific myocardial mass-blood flow correlation obeyed to allometric scaling law. Blood flow information could be directly derived from structural information acquired from CCTA.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Humanos , Angiografía Coronaria/métodos , Estudios Retrospectivos , Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada por Rayos X/métodos , Corazón , Valor Predictivo de las Pruebas
5.
Eur Radiol ; 21(6): 1214-23, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21225269

RESUMEN

PURPOSE: To evaluate the effect of a computer-aided detection (CAD) algorithm on the performance of novice readers for detection of pulmonary embolism (PE) at CT pulmonary angiography (CTPA). MATERIALS AND METHODS: We included CTPA examinations of 79 patients (50 female, 52 ± 18 years). Studies were evaluated by two independent inexperienced readers who marked all vessels containing PE. After 3 months all studies were reevaluated by the same two readers, this time aided by CAD prototype. A consensus read by three expert radiologists served as the reference standard. Statistical analysis used χ(2) and McNemar testing. RESULTS: Expert consensus revealed 119 PEs in 32 studies. For PE detection, the sensitivity of CAD alone was 78%. Inexperienced readers' initial interpretations had an average per-PE sensitivity of 50%, which improved to 71% (p < 0.001) with CAD as a second reader. False positives increased from 0.18 to 0.25 per study (p = 0.03). Per-study, the readers initially detected 27/32 positive studies (84%); with CAD this number increased to 29.5 studies (92%; p = 0.125). CONCLUSION: Our results suggest that CAD significantly improves the sensitivity of PE detection for inexperienced readers with a small but appreciable increase in the rate of false positives.


Asunto(s)
Algoritmos , Angiografía/métodos , Competencia Profesional , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Inteligencia Artificial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , South Carolina
6.
Eur J Radiol ; 135: 109478, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33360269

RESUMEN

PURPOSE: To investigate whether minimum intensity projection (MinIP) reconstructions enable more accurate depiction of pulmonary ground-glass opacity (GGO) compared to standard transverse sections and multiplanar reformat (MPR) series in patients with suspected coronavirus disease 2019 (COVID-19). METHOD: In this multinational study, chest CT scans of 185 patients were retrospectively analyzed. Diagnostic accuracy, diagnostic confidence, image quality regarding the assessment of GGO, as well as subjective time-efficiency of MinIP and standard MPR series were analyzed based on the assessment of six radiologists. In addition, the suitability for COVID-19 evaluation, image quality regarding GGO and subjective time-efficiency in clinical routine was assessed by five clinicians. RESULTS: The reference standard revealed a total of 149 CT scans with pulmonary GGO. MinIP reconstructions yielded significantly higher sensitivity (99.9 % vs 95.6 %), specificity (95.8 % vs 86.1 %) and accuracy (99.1 % vs 93.8 %) for assessing of GGO compared with standard MPR series. MinIP reconstructions achieved significantly higher ratings by radiologists concerning diagnostic confidence (medians, 5.00 vs 4.00), image quality (medians, 4.00 vs 4.00), contrast between GGO and unaffected lung parenchyma (medians, 5.00 vs 4.00) as well as subjective time-efficiency (medians, 5.00 vs 4.00) compared with MPR-series (all P < .001). Clinicians preferred MinIP reconstructions for COVID-19 assessment (medians, 5.00 vs 3.00), image quality regarding GGO (medians, 5.00 vs 3.00) and subjective time-efficiency in clinical routine (medians, 5.00 vs 3.00). CONCLUSIONS: MinIP reconstructions improve the assessment of COVID-19 in chest CT compared to standard images and may be suitable for routine application.


Asunto(s)
COVID-19/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , SARS-CoV-2 , Sensibilidad y Especificidad , Adulto Joven
7.
Int J Cardiol ; 281: 150-155, 2019 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-30738608

RESUMEN

BACKGROUND: The noninvasive equilibrium contrast-enhanced cardiac computed tomography (CCT) has potential for myocardial tissue characterization. The objective of this study was to test the feasibility of CCT-based extracellular volume (ECV) fraction in beagle models of doxorubicin-induced interstitial myocardial fibrosis, with cardiac magnetic resonance (CMR) as the reference. METHODS: This study was approved by local ethics committee. Thirteen beagles were included with ECV quantified by CCT and CMR at baseline, 16 and 24 weeks after modeling. Spearman correlation analysis was used to determine the association between CT ECV, CMR ECV, collagen volume fraction (CVF), LVEF and serum fibrosis index (Hyaluronic acid [HA], Laminin [LN] and Type-III procollagen [PCIII]). RESULTS: Median ECV values in CT and CMR at 16 and 24 weeks were significantly higher than those at baseline (CT ECV: 34.4% and 37.7% vs. 25.2%; CMR ECV: 32.2% and 37.4% vs. 22.7%; P < 0.001). A strong correlation was found between CCT and CMR for ECV (r = 0.899, P < 0.001). Both correlated well with CVF (r = 0.951 and 0.879 for CT and MR ECV vs. CVF, P < 0.001), serum fibrosis index (r = 0.830-0.907 for CT and MR ECV vs. HA, LN, PCIII, respectively, P < 0.05) and were inversely related to LVEF (r = -0.846 and -0.804 for CCT and CMR, P < 0.001). Bland-Altman analysis showed a small bias (1.5%), with 95% limits of agreement of -2.7% and 5.6%. CONCLUSIONS: CCT-derived ECV correlates well with CMR, histology and serum fibrosis index, suggesting that CCT is capable of myocardial tissue characterization.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Modelos Animales de Enfermedad , Doxorrubicina/toxicidad , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Tomografía Computarizada por Rayos X/métodos , Animales , Antibióticos Antineoplásicos/toxicidad , Cardiomiopatías/inducido químicamente , Perros , Femenino , Fibrosis
8.
Front Neurosci ; 13: 763, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31404153

RESUMEN

OBJECTIVE: To explore the relationship among serum uric acid (SUA) levels in different states of disease, human cognition, and spontaneous brain activities by resting-state functional MRI (rs-fMRI). METHODS: We prospectively recruited 100 subjects (age 58 ± 11 years, 55 females) who underwent fasting blood sampling, cognitive tests and rs-fMRI scans. The subjects were divided into two groups by sex and each sex group was further stratified into three subgroups according to SUA level in different states of disease. The amplitude of low-frequency fluctuation (ALFF) method was applied to assess spontaneous brain activity among groups. Pearson's correlation analysis was used to investigate the relationships between the mean ALFF values (mALFF) and cognitive tests. RESULTS: A total of 97 patients completed the study protocol successfully. Significant differences in age, education level, number connection test (NCT), and word fluency were observed among the three subgroups in males (all P < 0.05). Results of group-by-sex interaction were distributed in bilateral pallidum and putamen [voxel P-value < 0.001, cluster P-value < 0.05, Gaussian random field (GRF)-corrected]. The tendency of the SUA effect on mALFF was different in males and females, particularly in corresponding High SUA subgroups (that is pre-hyperuricemia, both P < 0.001). Among the male subjects, mALFF values of the bilateral pallidum and putamen negatively correlated with attention/executive function. CONCLUSION: Our results suggest that elevated SUA levels have different effects on spontaneous brain activities and cognitive function in males and females. Males with pre-hyperuricemia and hyperuricemia are more susceptible to changes in spontaneous brain activities and lower neuropsychological assessment scores, particularly in word fluency tests and NCT, compared to females.

9.
Eur J Radiol ; 117: 69-74, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31307655

RESUMEN

PURPOSE: To investigate the protective effect of oral Vitamin C on DNA double-strand breaks (DSBs) after abdominal contrast-enhanced CT examination. MATERIALS AND METHODS: Sixty patients undergoing abdominal multiphase contrast-enhanced CT were divided into control group (n = 30) and prevention group (n = 30). Patients in the prevention group were orally administered 1 g Vitamin C 30-120 minutes prior to CT examination. Blood samples were obtained prior to and 5 min following CT examination for each subject. γ-H2AX foci representing DSBs in the nucleus of lymphocytes were marked by fluorescent markers. Change in γ-H2AX foci/cell was compared through Student t-tests or ANOVA testing. The relationship between physical parameters and increase in γ-H2AX foci was analyzed through Pearson or Spearman correlation analysis. RESULTS: The mean increase in γ-H2AX was 0.49 foci /cell in the control group and 0.19 foci/cell in the prevention group (p < 0.001), corresponding to a 61% reduction in the mean increase in γ-H2AX foci in the prevention group compared to the control group. In the prevention group, increase in γ-H2AX foci/cell positively correlated with dose length product and volume CT dose index (r = 0.449 and 0.403, respectively; both p < 0.05). No difference in the increase in γ-H2AX foci/cell was found between the different time interval subgroups of 30, 60, and 120 min between Vitamin C administration and CT examination (p > 0.05). CONCLUSION: Oral Vitamin C can significantly reduce the level of DSBs after abdominal contrast-enhanced CT examination and is a simple and effective method to decrease DNA damage.


Asunto(s)
Ácido Ascórbico/administración & dosificación , Ácido Ascórbico/farmacología , Roturas del ADN de Doble Cadena/efectos de la radiación , Profilaxis Pre-Exposición , Radiografía Abdominal/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos , Anciano , Antioxidantes/administración & dosificación , Antioxidantes/farmacología , Daño del ADN , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Adulto Joven
10.
Eur J Radiol ; 84(6): 1062-7, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25843418

RESUMEN

OBJECTIVES: To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. METHODS: 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTAD: coronary CT angiography (CTA), diastolic phase; (b) CTAS: coronary CTA, systolic phase; (c) CaScD: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (-15HU, -30 HU, -45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. RESULTS: Mean EATV differed between all three image series at a -30HU threshold (CTAD 87.2 ± 38.5 ml, CTAS 90.9 ± 37.7 ml, CaScD 130.7 ± 49.5 ml, P<0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P=0.225). Mean EATV for contrast enhanced CTA at a -15HU threshold (CTAD15 102.4 ± 43.6 ml, CTAS15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at -45HU threshold (CaScD45 105.3 ± 40.8 ml). The correlation was excellent: CTAS15-CTAD15, rho=0.943; CTAD15-CaScD45, rho=0.905; CTAS15-CaScD45, rho=0.924; each P<0.001). Bias values from Bland Altman Analysis were: CTAS15-CTAD15, 4.9%; CTAD15-CaScD45, -4.3%; CTAS15-CaScD45, 0.6%. CONCLUSIONS: Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements.


Asunto(s)
Tejido Adiposo/patología , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/patología , Pericardio/patología , Tomografía Computarizada por Rayos X , Tejido Adiposo/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardio/diagnóstico por imagen , Sístole , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA