Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Acta Radiol ; 65(7): 689-699, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38778748

RESUMEN

BACKGROUND: Post-treatment evaluation of patients with rectal cancer (RC) using magnetic resonance imaging (MRI) burdens medical resources, necessitating an exploration of abbreviated protocols. PURPOSE: To evaluate the diagnostic performance of abbreviated MRI (A-MRI) for the post-treatment evaluation of RC patients. MATERIAL AND METHODS: This retrospective study included RC patients who underwent non-contrast rectal MRI and standard liver MRI, as well as abdominal contrast-enhanced computed tomography (CECT) for post-treatment evaluation. A-MRI comprised diffusion-weighted imaging (DWI) and T2-weighted imaging of the upper abdomen and the pelvic cavity. Three radiologists independently reviewed A-MRI, CECT, and standard liver MRI in the detection of viable disease. The diagnostic performances were compared using a reference standard considering all available information, including pathology, FDG-PET, endoscopic results, and clinical follow-up. RESULTS: We included 78 patients (50 men, 28 women; mean age=60.9 ± 10.2 years) and observed viable disease in 34 (43.6%). On a per-patient-basis analysis, A-MRI showed significantly higher sensitivity (95% vs. 81%, P = 0.04) and higher accuracy (93% vs. 82%, P < 0.01), compared to those of CECT, while A-MRI showed comparable sensitivity (91% vs. 91%, P = 0.42) and accuracy (97% vs. 98%, P = 0.06) to that of standard liver MRI. On a per-lesion-based analysis, A-MRI exhibited significantly superior lesion detectability than that of CECT (figure of merit 0.91 vs. 0.77, P < 0.01) and comparable to that of standard liver MRI (figure of merit 0.91 vs. 0.92, P = 0.75). CONCLUSION: A-MRI exhibited higher sensitivity and diagnostic accuracy than those of CECT in the post-treatment evaluation of RC, while it showed comparable performances with standard liver MRI. A-MRI provides diagnostic added value in the follow-up of RC patients.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias del Recto , Sensibilidad y Especificidad , Humanos , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/terapia , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Anciano , Reproducibilidad de los Resultados , Recto/diagnóstico por imagen
2.
Acta Radiol ; 64(1): 404-414, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34928730

RESUMEN

BACKGROUND: Recent advances in magnetic resonance imaging (MRI) may allow it to be an alternative emerging tool for the non-invasive evaluation of renal parenchymal disease. PURPOSE: To validate the usefulness of quantitative multiparametric MRI protocols and suggest the suitable quantitative MR sequence protocol to evaluate parenchymal fibrosis using an animal model of chronic kidney disease (CKD) by long-term adenine intake. MATERIAL AND METHODS: In this prospective animal study, 16 male Wistar rats were analyzed and categorized into three groups. Rats in the CKD groups underwent 0.25% adenine administration for three or six weeks. Quantitative MRI protocols, including diffusion-weighted imaging (DWI), T1ρ (T1 rho), and T2* mapping were performed using a 9.4-T animal MR scanner. A semi-quantitative histopathologic analysis for renal fibrosis was conducted. Quantitative MR values measured from anatomic regions of kidneys underwent intergroup comparative analyses. RESULTS: The apparent diffusion coefficient (ADC) and T1 (T1 rho) values were significantly increased in all CKD groups. Values measured from the cortex and outer medulla showed significant intergroup differences. Total ADC values tended to increase according to periods, and T1ρ values increased in three weeks and decreased in six weeks. CONCLUSION: Quantitative MRI protocols could be a non-invasive assessment modality in the diagnosis and evaluation of CKD. Particularly, T1ρ may be a suitable MR sequence to quantitatively assess renal parenchymal fibrosis.


Asunto(s)
Imagen por Resonancia Magnética , Insuficiencia Renal Crónica , Ratas , Masculino , Animales , Estudios Prospectivos , Ratas Wistar , Imagen por Resonancia Magnética/métodos , Insuficiencia Renal Crónica/diagnóstico por imagen , Insuficiencia Renal Crónica/patología , Riñón/diagnóstico por imagen , Riñón/patología , Imagen de Difusión por Resonancia Magnética/métodos , Fibrosis
3.
Int J Hyperthermia ; 33(8): 905-910, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28540795

RESUMEN

OBJECTIVE: We evaluated long-term follow-up results of radiofrequency ablation of benign thyroid nodules to analyse the role of marginal vital tissue on nodule regrowth. MATERIALS AND METHODS: We reviewed the medical records of 54 patients who underwent radiofrequency ablation between June 2008 and November 2013 with pressure symptoms, and/or cosmetic problems. All patients were followed up at least 12 months on three occasions. To evaluate an early sign of regrowth, three types of nodule volumes (total volume, ablated volume and vital volume) were measured and calculated using ultrasonography. Regrowth was defined as a more than a 50% increase in the total volume and vital volume increase was defined as a more than 50% increase compared to the previously reported smallest volume on ultrasonography. RESULTS: The mean follow-up period was 39.4 ± 21.7 (range, 13-87) months. Vital volume increases occurred in 31 nodules (57.4%) and there was regrowth in 13 nodules (24.1%). The mean timing of the vital volume increase was 27.5 ± 18.5 months, and for regrowth it was 39.9 ± 17.5 months. Vital volume increase tended to precede regrowth. CONCLUSION: Vital volume increase tended to occur earlier than regrowth and might be an early sign of regrowth in following-up after the radiofrequency ablation of benign thyroid nodules.


Asunto(s)
Ablación por Catéter , Nódulo Tiroideo/cirugía , Adulto , Anciano , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Resultado del Tratamiento , Ultrasonografía Doppler en Color , Adulto Joven
4.
J Clin Ultrasound ; 45(9): 542-550, 2017 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-28547764

RESUMEN

BACKGROUND: To investigate the agreement between Kupffer phase of Sonazoid contrast-enhanced sonography (CEUS) and hepatobiliary phase of gadoxetic acid-enhanced MRI in the evaluation of focal liver lesions (FLLs). METHODS: One hundred fifty-four FLLs in 154 patients who underwent both Sonazoid CEUS and gadoxetic acid-enhanced liver MRI were included in this retrospective study. FLL visibility on the Kupffer-phase images was graded as one (invisible or isoenhancing), two (vaguely visible or vaguely hypoenhancing), or three (clearly visible or clearly hypoenhancing), and that on the hepatobiliary-phase images of MRI was graded as one (invisible or hyper/isointense), two (vaguely visible or weakly hypointense), or three (clearly visible or strongly hypointense). Pairwise comparison of lesion visibility between the two modalities was performed, and intermodality agreement was assessed. RESULTS: On Kupffer-phase CEUS, 31 (20.1%) lesions were invisible, 17 (11.1%) were vaguely visible, and 106 (68.9%) were clearly visible. On the hepatobiliary-phase MRI, 9 (5.9%) lesions were invisible, 45 (29.2%) were vaguely visible, and 100 (64.9%) were clearly visible. Overall, lesion visibility scores were not significantly different between the two modalities (p = 0.121), but the visibility was significantly better on MRI in smaller lesions. Twenty-eight lesions (18.2%) showed discrepancy in the visibility on CEUS and MRI, and most of the cases (89.7%) were lesions that were invisible on CEUS but visible on MRI. CONCLUSIONS: The overall visibility of FLLs was comparable between the Kupffer phase of Sonazoid-CEUS and the hepatobiliary-phase images of gadoxetic acid-enhanced MRI, with a discrepancy between the two modalities in 18% of the cases. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:542-550, 2017.


Asunto(s)
Compuestos Férricos , Gadolinio DTPA , Aumento de la Imagen/métodos , Hierro , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Óxidos , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
J Korean Med Sci ; 31(7): 1114-20, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27366011

RESUMEN

The Clinical Assessment Interview for Negative Symptoms (CAINS) was developed to overcome the limitations of existing instruments and reflect the current view of negative symptoms. The aim of the present study was to evaluate the reliability and validity of the Korean version of the Clinical Assessment Interview for Negative Symptoms (K-CAINS). Inpatients (n = 49) and outpatients (n = 70) with schizophrenia were recruited from three institutions. The confirmative factor analysis, test-retest reliability, inter-rater reliability, convergent validity, and discriminant validity were assessed. The study group consisted of 71 males (59.7%) and 48 females (40.3%). Their mean age was 42.15 years (SD = 12.2). The K-CAINS was confirmed to be divided into two subscales of 9 items related to "motivation/pleasure" and 4 items related to "expression" in concordance with the original version of the CAINS. The results showed that the K-CAINS had a good inter-rater reliability (ICC = 0.84-0.94), test-retest reliability (r = 0.90, P < 0.001). Convergent validity was proven by demonstrating a significant correlation with the Positive and Negative Syndrome Scale (PANSS) negative subscale, and the Scale for the Assessment of Negative Symptoms (SANS). Discriminant validity was proven by the lack of a significant correlation with the PANSS positive subscale, the Korean version of the Beck depression inventory (BDI), the Korean version of the Calgary depression scale for schizophrenia (K-CDSS), and the Modified Simpson Angus scale (MSAS). The K-CAINS could be a reliable and valid tool to assess the negative symptoms of Korean schizophrenia patients.


Asunto(s)
Esquizofrenia/diagnóstico , Traducción , Adulto , Pueblo Asiatico , Análisis Discriminante , Femenino , Humanos , Entrevistas como Asunto , Masculino , Persona de Mediana Edad , Escalas de Valoración Psiquiátrica/normas , República de Corea
7.
J Ultrasound Med ; 34(3): 411-21, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25715362

RESUMEN

OBJECTIVES: To evaluate the utility of Kupffer-phase imaging by real-time contrast-enhanced sonography using the perflurobutane microbubble contrast agent Sonazoid (GE Healthcare, Oslo, Norway) in guiding biopsy or radiofrequency (RF) ablation of focal liver lesions. METHODS: A total of 75 patients (mean age, 59.7 years) who were referred for percutaneous biopsy (n = 42) or RF ablation (n = 33) were included in the study. Grayscale sonography and contrast-enhanced sonography using Sonazoid were performed in all patients before the procedure. The conspicuity of each targeted liver lesion on grayscale sonography, vascular-phase contrast-enhanced sonography, and Kupffer-phase contrast-enhanced sonography was graded using a 5-point scale. Lesion detection rates were calculated, and the conspicuity of the lesions among the imaging modalities was compared. The technical success of the procedures was also assessed. RESULTS: The procedures were conducted in 66 patients (biopsy in 41 and RF ablation in 25) under real-time guidance by Kupffer-phase contrast-enhanced sonography. Lesion detection rates were 77.3% (58 of 75), 84.0% (63 of 75), and 92.0% (69 of 75) on grayscale sonography, vascular-phase contrast-enhanced sonography, and Kupffer-phase contrast-enhanced sonography, respectively, and were significantly different among the 3 modalities (P= .034). Overall, lesion conspicuity was significantly increased on vascular-phase and Kupffer-phase contrast-enhanced sonography compared to grayscale sonography (P < .001). Technical success rates for the procedures were 95.2% (40 of 42) for biopsy and 69.7% (23 of 33) for RF ablation. CONCLUSIONS: Kupffer-phase imaging by contrast-enhanced sonography using Sonazoid increases the conspicuity of the liver lesions compared to grayscale sonography, and it is useful for real-time guidance of percutaneous biopsy or RF ablation of focal liver lesions.


Asunto(s)
Ablación por Catéter/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Compuestos Férricos/uso terapéutico , Hierro/uso terapéutico , Macrófagos del Hígado/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/cirugía , Óxidos/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Sistemas de Computación , Medios de Contraste/administración & dosificación , Femenino , Compuestos Férricos/administración & dosificación , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Hierro/administración & dosificación , Masculino , Persona de Mediana Edad , Óxidos/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos
8.
Abdom Imaging ; 39(2): 348-57, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24407727

RESUMEN

PURPOSE: To evaluate effect of tumor size and contour type for the detection of renal cell carcinoma (RCC) on unenhanced CT. METHODS: This retrospective institutional review board approved study that includes 111 patients with RCC and 100 patients without RCC who underwent unenhanced CT. Two readers performed a blinded and independent review of the presence of RCC on unenhanced CT. The area under the receiver operating characteristic curves (AUC) was compared by tumor size (<3 cm: small, or ≥3 cm: large) and contour type (endophytic, mesophytic, or exophytic). RESULTS: For tumor size, the AUC for small RCC (0.70 and 0.78, for reader 1 and reader 2) was significantly lower than that for large RCC (0.97 and 0.99, for reader 1 and reader 2) (p < 0.001). As for contour type of tumor, the AUC for endophytic RCC (0.60 and 0.71, for reader 1 and reader 2) was significantly lower than that for mesophytic RCC (0.95 and 0.98, for reader 1 and reader 2) and exophytic RCC (0.98 and 0.99, reader 1 and reader 2) (p < 0.001). CONCLUSION: On unenhanced CT, tumor size and contour type can affect the detection of RCC. While most large or exophytic RCC can be easily detected, the detection of small and endophytic RCC is highly limited.


Asunto(s)
Carcinoma de Células Renales/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/patología , Femenino , Humanos , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad
9.
Diagnostics (Basel) ; 14(8)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38667435

RESUMEN

The accurate measurement of splenic size is essential for the diagnosis and management of various gastrointestinal and hematological conditions. While ultrasound (US) and computed tomography (CT) are widely used imaging modalities for assessing splenic size, discrepancies between their measurements have been observed in clinical practice. This study aimed to analyze the measurement differences between US and CT and identify factors influencing these differences. A retrospective analysis of 598 asymptomatic patients who underwent both abdominal US and CT was conducted. Measurements of splenic size obtained from US, axial CT, and coronal CT scans were compared, and various factors such as patient demographics, operator experience, and imaging parameters were evaluated to elucidate their impact on the measurement discrepancies. The results revealed that US consistently underestimated splenic size compared to CT. The magnitude of the discrepancy was influenced by factors such as patient age, body mass index (BMI), depth of the spleen from skin on US and that on CT, visibility of the splenic hilum on US, sonic window quality, and operator experience. This study underscores the importance of considering these factors when interpreting splenic measurements obtained from different imaging modalities in clinical practice.

10.
Radiology ; 269(2): 493-503, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23878284

RESUMEN

PURPOSE: To evaluate the incremental value of using diffusion-weighted magnetic resonance (MR) imaging in addition to T2-weighted imaging for the detection of prostate cancer in the transition zone and the assessment of tumor aggressiveness. MATERIALS AND METHODS: This retrospective HIPAA-compliant institutional review board-approved study included 156 consecutive patients (median age, 59.2 years) who underwent MR imaging before radical prostatectomy. Two readers who were blinded to patient data independently recorded their levels of suspicion on a five-point scale of the presence of transition zone tumors on the basis of T2-weighted imaging alone and then, 4 weeks later, diffusion-weighted imaging and T2-weighted imaging together. Apparent diffusion coefficients (ADCs) were measured in transition zone cancers and glandular and stromal benign prostatic hyperplasia. Areas under the receiver operating characteristic curves were used to evaluate detection accuracy, and generalized linear models were used to test ADC differences between benign and malignant prostate regions. Whole-mount step-section histopathologic examination was the reference standard. RESULTS: In overall tumor detection, addition of diffusion-weighted imaging to T2-weighted imaging improved the areas under the receiver operating characteristic curves for readers 1 and 2 from 0.60 and 0.60 to 0.75 and 0.71, respectively, at the patient level (P = .004 for reader 1 and P = .027 for reader 2) and from 0.64 and 0.63 to 0.73 and 0.68, respectively, at the sextant level (P = .001 for reader 1 and P = .100 for reader 2). Least squares mean ADCs (× 10(-3) mm(2)/sec) in glandular and stromal benign prostatic hyperplasia were 1.44 and 1.09, respectively. Mean ADCs were inversely associated with tumor Gleason scores (1.10, 0.98, 0.87, and 0.75 for Gleason scores of 3 + 3, 3 + 4, 4 + 3, and ≥ 4 + 4, respectively). CONCLUSION: Use of diffusion-weighted imaging in addition to T2-weighted imaging improved detection of prostate cancer in the transition zone, and tumor ADCs were inversely associated with tumor Gleason scores in the transition zone.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Hiperplasia Prostática/diagnóstico , Hiperplasia Prostática/patología , Neoplasias de la Próstata/patología , Estudios Retrospectivos
11.
Radiology ; 268(2): 440-50, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23481164

RESUMEN

PURPOSE: To compare diagnostic accuracy of T2-weighted magnetic resonance (MR) imaging with that of multiparametric (MP) MR imaging combining T2-weighted imaging with diffusion-weighted (DW) MR imaging, dynamic contrast material-enhanced (DCE) MR imaging, or both in the detection of locally recurrent prostate cancer (PCa) after radiation therapy (RT). MATERIALS AND METHODS: This retrospective HIPAA-compliant study was approved by the institutional review board; informed consent was waived. Fifty-three men (median age, 70 years) suspected of having post-RT recurrence of PCa underwent MP MR imaging, including DW and DCE sequences, within 6 months after biopsy. Two readers independently evaluated the likelihood of PCa with a five-point scale for T2-weighted imaging alone, T2-weighted imaging with DW imaging, T2-weighted imaging with DCE imaging, and T2-weighted imaging with DW and DCE imaging, with at least a 4-week interval between evaluations. Areas under the receiver operating characteristic curve (AUC) were calculated. Interreader agreement was assessed, and quantitative parameters (apparent diffusion coefficient [ADC], volume transfer constant [K(trans)], and rate constant [k(ep)]) were assessed at sextant- and patient-based levels with generalized estimating equations and the Wilcoxon rank sum test, respectively. RESULTS: At biopsy, recurrence was present in 35 (66%) of 53 patients. In detection of recurrent PCa, T2-weighted imaging with DW imaging yielded higher AUCs (reader 1, 0.79-0.86; reader 2, 0.75-0.81) than T2-weighted imaging alone (reader 1, 0.63-0.67; reader 2, 0.46-0.49 [P ≤ .014 for all]). DCE sequences did not contribute significant incremental value to T2-weighted imaging with DW imaging (reader 1, P > .99; reader 2, P = .35). Interreader agreement was higher for combinations of MP MR imaging than for T2-weighted imaging alone (κ = 0.34-0.63 vs κ = 0.17-0.20). Medians of quantitative parameters differed significantly (P < .0001 to P = .0233) between benign tissue and PCa (ADC, 1.64 × 10(-3) mm(2)/sec vs 1.13 × 10(-3) mm(2)/sec; K(trans), 0.16 min(-1) vs 0.33 min(-1); k(ep), 0.36 min(-1) vs 0.62 min(-1)). CONCLUSION: MP MR imaging has greater accuracy in the detection of recurrent PCa after RT than T2-weighted imaging alone, with no additional benefit if DCE is added to T2-weighted imaging and DW imaging.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Recurrencia Local de Neoplasia/diagnóstico , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/radioterapia , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Biopsia , Medios de Contraste , Imagen de Difusión por Resonancia Magnética , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Estadísticas no Paramétricas , Resultado del Tratamiento
12.
J Comput Assist Tomogr ; 37(3): 440-2, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23674018

RESUMEN

PURPOSE: This study aimed to evaluate the efficacy of computed tomography (CT)-based acute pyelonephritis (APN) grades for predicting clinical severity and disease course. MATERIALS AND METHODS: This study involved the analysis of the data of 204 consecutive patients with APN who underwent a CT examination at admission. Patients who had undergone prior treatment and those with ureteral calculi or an abscess by CT were excluded. Computed tomographic findings were divided into 4 grades according to renal parenchymal involvement, as follows: no renal parenchyma involvement (grade 1), less than 25% involvement (grade 2), 25% to 50% involvement (grade 3), and greater than 50% (grade 4). Patients with these grades were compared with respect to APN severity index (highest body temperature, initial C-reactive protein, and leukocytosis) and recovery index (hospital stay, fever duration, and leukocytosis duration). RESULTS: A total of 204 patients of mean age 39.3 years were included. Acute pyelonephritis severity indices and recovery indices increased with APN grade. Mean highest body temperature values were 38.3°C and 38.9°C in grades 1 and 4, respectively (P = 0.002). Mean hospital stay increased from 5.7 days for grade 1 to 7.6 days for grade 4 (P < 0.001). Initial C-reactive protein, initial leukocytosis, fever duration, and leukocytosis duration also increased with APN grade. CONCLUSIONS: This study suggests that APN grades, as determined by CT examination, valuably predict the clinical course of APN.


Asunto(s)
Pielonefritis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Enfermedad Aguda , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pielonefritis/patología , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
13.
Ultrasonography ; 42(4): 555-560, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37586719

RESUMEN

PURPOSE: The objective of this study was to evaluate pain and image quality associated with the use of two different ultrasound transducers. METHODS: Fifty healthy male participants aged 30 years or older were prospectively enrolled. All ultrasound procedures were performed using a V8 machine (Samsung Medison, Seoul, Korea) equipped with EA2-11 (conventional) and miniER7 (small-caliber) transrectal transducers, operated by a single genitourinary radiologist. To minimize bias, one group of volunteers underwent ultrasonography with the conventional transducer first, followed by the small transducer. For the remaining participants, the examinations were performed in the opposite order. Ultrasonography, including the measurement of total prostate and transitional zone volumes, was conducted in accordance with standard practice. After testing with both probes, participants were asked to rate their pain on a 10-point numerical rating scale (NRS). A radiologist then evaluated the quality of the images acquired with each probe using a 5-point numeric scale and compared the prostate volume measurements obtained by each method. RESULTS: The mean NRS scores associated with the conventional and small transducers were 4.7±1.8 and 2.7±1.2, respectively (P<0.05). The mean ultrasound image qualities from the two transducers were statistically similar (4.78 and 4.74, P>0.05). The whole prostate gland volume as measured with the conventional transducer (mean±standard deviation, 24.2±9.1 mL) was greater than the measurement (22.1±8.7 mL) obtained with the small-caliber transducer (P<0.05). However, only two of the 50 whole gland volume measurements differed by more than two standard deviations. CONCLUSION: The use of a small transrectal probe significantly reduced pain without compromising image quality.

14.
Diagnostics (Basel) ; 13(3)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36766584

RESUMEN

Preoperative diagnosis of borderline ovarian tumors (BOTs) is of increasing concern. This study aimed to determine computed tomography (CT) features in differentiating stage 1 BOTs from stage I malignant epithelial ovarian tumors (MEOTs). A total of 170 ovarian masses (97 BOTs and 73 MEOTs) from 141 consecutive patients who underwent preoperative CT imaging were retrospectively analyzed. Two readers independently and retrospectively reviewed quantitative and qualitative CT features. Multivariate logistic analysis demonstrated that a larger tumor size (p = 0.0284 for reader 1, p = 0.0391 for reader 2) and a smaller solid component (p = 0.0007 for reader 1, p = 0.0003 for reader 2) were significantly associated with BOTs compared with MEOTs. In the subanalysis of cases with a solid component, smaller (p = 0.0092 for reader 1, p = 0.0014 for reader 2) and ill-defined (p = 0.0016 for reader 1, p = 0.0414 for reader 2) solid component was significantly associated with BOTs compared with MEOTs. Tumor size and the size and margin of the solid component were useful for differentiating stage 1 BOTs from stage 1 MEOTs on CT images.

15.
Ultrasonography ; 42(3): 440-445, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37337359

RESUMEN

PURPOSE: This study was conducted to assess the role of renal Doppler ultrasonography (US) in predicting non-diabetic kidney disease (NDKD) in patients with diabetes, using histologic findings as the reference standard. METHODS: Fifty-nine consecutive patients with diabetes who underwent renal Doppler US and native kidney biopsy were included in this retrospective, single-institutional study. Based on histologic findings, patients were classified as having diabetic nephropathy (DN) or NDKD. Renal Doppler US findings, including cortical echogenicity, corticomedullary differentiation, and the resistive index (RI), were compared between DN and NDKD. A subgroup analysis according to chronic kidney disease (CKD) status was also performed. RESULTS: Cortical echogenicity and corticomedullary differentiation showed no significant differences between DN and NDKD (P=0.887 and P>0.99, respectively), whereas the RI was significantly higher in patients with DN than in those with NDKD (P=0.032). The subgroup analysis revealed a significant difference in the RI between DN and NDKD in patients with diabetes and CKD (P=0.010), but a significant difference was not found in those without CKD (P=0.713). When limited to patients with diabetes and CKD, the RI had an area under the curve value of 0.759, sensitivity of 57.1%, specificity of 81.0%, positive likelihood ratio of 3.0, and negative LR of 0.5 for predicting NDKD, using a cutoff value of ≤0.69. CONCLUSION: Renal Doppler US may be useful in predicting NDKD in patients with diabetes and CKD.

16.
Diagnostics (Basel) ; 13(6)2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36980314

RESUMEN

It is challenging to overcome motion artifacts in diffusion-weighted imaging (DWI) of the abdomen. This study aimed to evaluate the image quality of motion-corrected DWI of the liver using non-rigid registration in comparison with conventional DWI (c-DWI) in patients with liver diseases. Eighty-nine patients who underwent 3-T magnetic resonance imaging (MRI) of the liver were retrospectively included. DWI was performed using c-DWI and non-rigid motion-corrected (moco) DWI was performed in addition to c-DWI. The image quality and conspicuity of hepatic focal lesions were scored using a five-point scale by two radiologists and compared between the two DWI image sets. The apparent diffusion coefficient (ADC) was measured in three regions of the liver parenchyma and in hepatic focal lesions, and compared between the two DWI image sets. Moco-DWI achieved higher scores in image quality compared to c-DWI in terms of liver edge sharpness and hepatic vessel margin delineation. The conspicuity scores of hepatic focal lesions were higher in moco-DWI. The standard deviation values of ADC of the liver parenchyma were lower in the moco-DWI than in the c-DWI. Moco-DWI using non-rigid registration showed improved overall image quality and provided more reliable ADC measurement, with an equivalent scan time, compared with c-DWI.

17.
Acta Radiol ; 53(5): 501-7, 2012 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-22572467

RESUMEN

BACKGROUND: Benign regional lymph nodes (LNs) are sometimes enlarged in gastric cancer patients due to reactive or inflammatory changes. Frequently these enlarged LNs can mimic LN metastasis and lead to overstaging. PURPOSE: To assess frequency of benign regional LNs in gastric cancer patients compared with that in a healthy population and to assess the frequency of benign regional LNs in gastric cancer according to T-staging. MATERIAL AND METHODS: Between August 2005 and June 2009, 177 patients with surgically proven gastric cancer without LN metastasis (TanyN0M0) who had previously undergone preoperative multidetector row CT (MDCT) and 168 healthy patients who visited the healthcare center and underwent an abdominal MDCT were included in this retrospective study. An abdominal radiologist evaluated the distribution of regional LNs and measured the short diameter of LNs ≥6 mm, ≥8 mm, and ≥10 mm. The number of enlarged benign LNs was compared between the two groups, and the distribution of LN with regard to T-stage of gastric cancer was also evaluated. RESULTS: At least one LN ≥6 mm, ≥8 mm, and ≥10 mm was detected in 64.4% (114/177), 22.0% (39/177), and 4.0% (7/177) of patients in the gastric cancer group, respectively, compared to 29.8% (50/168), 4.2% (7/168), and 0% of patients in the healthy group, respectively. The difference between the two groups was statistically significant (P <0.0001). The LN ≥8 mm was found in 14.9% (20/134) in early gastric cancer (T1), and 44.2% (19/43) in advanced cancer (T2 or higher); the difference was statistically significant (P = 0.0002). However, the frequency of LN ≥6 mm in mucosal cancer (T1a) and submucosal cancer (T2b) was not significantly different, regardless of its size. CONCLUSION: Benign regional LNs ≥6 mm are more frequently detected in gastric cancer patients than in a healthy population and in advanced gastric cancer than in early cancer.


Asunto(s)
Ganglios Linfáticos/diagnóstico por imagen , Neoplasias Gástricas/patología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Metástasis Linfática/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/cirugía
18.
J Comput Assist Tomogr ; 35(5): 535-8, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21926844

RESUMEN

OBJECTIVES: The objective of the study was to retrospectively evaluate (a) which clinical/laboratory features are associated with the presence of diffuse gallbladder wall thickening (DGWT) in cirrhotic patients and (b) whether the degree of DGWT is correlated with such clinical/laboratory variables. METHODS: After excluding patients with DGWT or laboratory test abnormalities from known causes unrelated to liver cirrhosis, a retrospective review of liver computed tomography obtained from 242 consecutive cirrhotic patients was performed by 2 radiologists in consensus to determine the presence of DGWT of greater than 3 mm in thickness and, if present, to measure the degree of DGWT defined as maximal thickness. Univariate and multivariate analysis were performed to evaluate association between presence/degree of DGWT and clinical/laboratory features. RESULTS: Of 242 patients, 73 (30.2%) had DGWT. Diffuse gallbladder wall thickening was seen in 7.6% (12/157) of patients with Child-Pugh class A, 61.1% (33/54) of class B, and 90.3% (28/31) of class C (P < 0.001). The presence of ascites, lower platelet count, and lower albumin level were independently associated with the presence of DGWT (P < 0.01, P = 0.01, and P = 0.02, respectively). However, these factors did not show significant correlation with the degree of DGWT. CONCLUSIONS: The presence of DGWT in cirrhotic patients is associated with the presence of ascites, lower platelet count, and lower albumin level. The degree of DGWT is not correlated with such variables.


Asunto(s)
Enfermedades de la Vesícula Biliar/diagnóstico por imagen , Cirrosis Hepática/complicaciones , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Ascitis/diagnóstico por imagen , Distribución de Chi-Cuadrado , Medios de Contraste , Femenino , Enfermedades de la Vesícula Biliar/patología , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Recuento de Plaquetas , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Albúmina Sérica/análisis
19.
J Obstet Gynaecol Res ; 37(3): 228-35, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21114582

RESUMEN

AIM: To evaluate retrospectively the performance of computed tomography (CT) for the diagnosis of acute pelvic inflammatory disease (PID) by the use of clinical and laboratory data as the reference standard. METHODS: The study was approved by the institutional review board. A total of 190 women of reproductive age (age range, 16-49 years; mean age, 29.3 ± 7.6 years) with complaints of non-traumatic acute lower abdominal pain underwent subsequent abdominopelvic CT. The diagnosis of acute PID was confirmed by the clinical and laboratory findings. Two radiologists performed a blinded, independent, retrospective review of the CT findings of acute PID. Discordant findings were resolved by a consensus review with a third radiologist. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of each CT finding for the diagnosis of acute PID were determined. Kappa statistics were used to estimate agreement between readers. RESULTS: Pelvic inflammatory disease was present in 48 (25.3%) of the 190 patients. The most specific CT finding for the diagnosis of acute PID was tubal thickening of both fallopian tubes (95.1%). The most sensitive CT finding was mid-pelvic fat stranding (60.4%). CONCLUSION: The CT finding of tubal thickening is highly specific for the diagnosis of acute PID, although overall CT sensitivity is poor.


Asunto(s)
Enfermedad Inflamatoria Pélvica/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Enfermedad Aguda , Adolescente , Adulto , Trompas Uterinas/patología , Femenino , Humanos , Persona de Mediana Edad , Variaciones Dependientes del Observador , Enfermedad Inflamatoria Pélvica/patología , Estudios Retrospectivos , Sensibilidad y Especificidad
20.
Diagnostics (Basel) ; 11(12)2021 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-34943405

RESUMEN

The noninvasive diagnosis of hepatic steatosis is of increasing concern. This study investigated the association of hepatic steatosis determined by non-enhanced CT criteria with clinical parameters in a screening population. Asymptomatic patients who underwent abdominal CT at our healthcare center were retrospectively analyzed (n = 339). Two radiologists measured the attenuation values of the liver parenchyma and spleen using non-enhanced CT images. CT criteria for hepatic steatosis were (a) absolute liver attenuation value <48 Hounsfield units (HU), (b) liver-to-spleen attenuation ratio <0.8, and (c) attenuation difference between the liver and spleen <-10. Body mass index (BMI) and hepatic steatosis index (HSI) were calculated, and laboratory findings were recorded. The association of hepatic steatosis with clinical parameters was assessed using univariate and logistic regression analyses. The presence of hepatic steatosis was significantly associated with the levels of serum fasting glucose and triglycerides, the alanine aminotransferase to aspartate aminotransferase (ALT/AST) ratio, BMI, and HSI values using any of the CT criteria. Logistic regression analysis revealed that the serum fasting glucose level and HSI were significantly associated with hepatic steatosis using criterion (a), while the ALT/AST ratio and HSI were associated with hepatic steatosis using criteria (b) and (c). The presence of hepatic steatosis on non-enhanced CT should be considered to indicate possible clinical profile abnormalities regarding metabolic syndrome.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA