Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38501333

RESUMEN

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Asunto(s)
Ablación por Catéter , Cicatriz , Recurrencia , Reoperación , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Cicatriz/fisiopatología , Cicatriz/diagnóstico , Cicatriz/cirugía , Cicatriz/etiología , Factores de Tiempo , Potenciales de Acción , Agujas , Frecuencia Cardíaca , Factores de Riesgo , Resultado del Tratamiento
2.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38367008

RESUMEN

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Taquicardia Ventricular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Solución Salina/efectos adversos , Vapor , Estudios Prospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Ventricular/cirugía , Irrigación Terapéutica/efectos adversos
3.
J Cardiovasc Electrophysiol ; 34(1): 135-141, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36300705

RESUMEN

INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Péptido Natriurético Encefálico , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/patología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/metabolismo , Ecocardiografía Transesofágica , Péptido Natriurético Encefálico/sangre , Péptido Natriurético Encefálico/química , Apnea Obstructiva del Sueño/diagnóstico , Volumen Sistólico , Función Ventricular Izquierda
4.
J Cardiovasc Electrophysiol ; 32(4): 1044-1052, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33512055

RESUMEN

BACKGROUND: Nonchicken wing left atrial appendage (LAA) morphology is associated with higher risk for stroke in patients with atrial fibrillation (AF) than chicken wing (CW) morphology. OBJECTIVE: Assess whether LAA morphology predicts the formation of LAA thrombus independent of age, sex, presenting rhythm, left ventricular ejection fraction (LVEF), or anticoagulant use. METHODS: A cross-sectional analysis was performed on patients prospectively enrolled in the Vanderbilt LAA Registry or presenting for transesophageal echocardiogram (TEE) between January 1, 2015, and November 1, 2017 (n = 306). Two physicians independently reviewed TEEs interpreted as having LAA thrombus. Determination of LAA morphology, ejection velocity, and presence of thrombus (n = 102) were based on 0°, 45°, 90°, and 135° TEE views. The control cohort (n = 204) included consecutive AF patients undergoing TEE without LAA thrombus. RESULTS: LAA morphology in patients with LAA thrombus was: 35% windsock, 47% broccoli, and 12% CW. Windsock (odds ratio [OR], 4.0; 95% confidence interval [CI]: 1.7-9.3, p = .001) and broccoli (OR, 6.6; 95% CI: 2.6-16.6; p < .001) morphology were higher risk for thrombus compared to CW. Female sex predicted higher-odds for LAA thrombus (OR, 2.6; 95% CI: 1.4-4.8; p = .002) as did LAA-EV < 20 cm/s (OR, 11.12; 95% CI: 5.6-22.1). Anticoagulation use (OR, 0.5; 95% CI: 0.3-0.9; p = .03) and higher LVEF (OR, 0.95; 95% CI: 0.93-0.98; p < .001) were associated with lower risk. In patients with a CW morphology who had LAA thrombus, 4 of the 7 had an LAA-EV < 20 cm/s and acute systolic heart failure with LVEF < 30% or active malignancy. In multivariable linear regression analysis controlling for presenting rhythm, anticoagulant use, age, sex, and LVEF, CW morphology appears relatively protective from LAA thrombus (p = .001). CONCLUSION: CW LAA morphology appears relatively protective against the formation of LAA thrombus.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Trombosis , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Estudios Transversales , Ecocardiografía Transesofágica , Femenino , Humanos , Volumen Sistólico , Trombosis/diagnóstico por imagen , Función Ventricular Izquierda
5.
J Cardiovasc Electrophysiol ; 30(10): 1994-2001, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31328298

RESUMEN

INTRODUCTION: Subclinical atrial fibrillation (AF), in the form of cardiac implantable device-detected atrial high rate episodes (AHREs), has been associated with increased thromboembolism. An implantable cardioverter-defibrillator (ICD) lead with a floating atrial dipole may permit a single lead (DX) ICD system to detect AHREs. We sought to assess the utility of the DX ICD system for subclinical AF detection in patients, with a prospective multicenter, cohort-controlled trial. METHODS AND RESULTS: One hundred fifty patients without prior history of AF (age 59 ± 13 years; 108 [72%] male) were enrolled into the DX cohort and implanted with a Biotronik DX ICD system at eight centers. Age-, sex-, and left ventricular ejection fraction-matched single- and dual-chamber ICD cohorts were derived from a Cornell database and from the IMPACT trial, respectively. The primary endpoint were AHRE detection at 12 months. During median 12 months follow-up, AHREs were detected in 19 (13%) patients in the DX, 8 (5.3%) in the single-chamber, and 19 (13%) in the dual-chamber cohorts. The rate of AHRE detection was significantly higher in the DX cohort compared to the single-chamber cohort (P = .026), but not significantly different compared to the dual-chamber cohort. There were no inappropriate ICD therapies in the DX cohort. At 12 months, only 3.0% of patients in the DX cohort had sensed atrial amplitudes less than 1.0 mV. CONCLUSION: Use of a DX ICD lead allows subclinical AF detection with a single lead DX system that is superior to that of a conventional single-chamber ICD system.


Asunto(s)
Fibrilación Atrial/diagnóstico , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Tecnología de Sensores Remotos/instrumentación , Potenciales de Acción , Adulto , Anciano , Enfermedades Asintomáticas , Fibrilación Atrial/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Estados Unidos
6.
Pacing Clin Electrophysiol ; 42(7): 965-969, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31045260

RESUMEN

BACKGROUND: Boston Scientific (Marlborough, MA, USA) implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds) manufactured between 2008 and 2014 are potentially subject to premature battery depletion through a low-voltage capacitor malfunction occurring as a result of hydrogen buildup within the device. Although some of these devices are currently under advisory, other devices manufactured during this timeframe carry a lower risk of the same malfunction. These same devices are known to have superior longevity in general, and the overall mean lifespan of the devices remains long. METHODS: All patients implanted or followed at our two centers who experienced premature battery depletion and had a Boston Scientific ICD or CRT-D potentially at risk for low-voltage capacitor malfunction were studied retrospectively. RESULTS: Nineteen out of 838 patients (2.3%) with devices potentially at risk have had premature battery depletion: 5.7% of those under advisory and 1.1% of those not under advisory. None of our patients had compromised therapy, and all had >27 days of projected battery longevity remaining. CONCLUSIONS: Undetected premature battery depletion in this population of ICDs has the potential to expose a patient to an interval of time where the device is unable to provide therapy. However, with enrollment in remote monitoring, regular follow-up, and attention to audible alerts, the risk of therapy loss due to low-voltage state can be effectively mitigated. For these reasons, prophylactic generator replacement is not recommended.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Suministros de Energía Eléctrica , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Estudios Retrospectivos
10.
J Cardiovasc Electrophysiol ; 27(1): 120-4, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26511459

RESUMEN

We present three cases within 11 months at a single institution of sustained VT that fell below the programmed detection rate of the patients' implantable cardioverter-defibrillators (ICDs), two of which continued until converting to an agonal VF that did not meet criteria for detection, and a third case that could not be successfully defibrillated after a prolonged period of VT. These episodes may be under-recognized due to the dependence of device diagnostic storage on programming and the post-mortem effort that is often required to review these events. Some patients, likely those with the most advanced heart failure, may not tolerate sustained ventricular tachycardia (VT) and may even die from ventricular arrhythmias without ever having a rhythm that meets detection criteria in a ventricular fibrillation (VF) zone.


Asunto(s)
Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/instrumentación , Taquicardia Ventricular/terapia , Anciano , Causas de Muerte , Desfibriladores Implantables , Electrocardiografía , Resultado Fatal , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Insuficiencia del Tratamiento
11.
JACC Clin Electrophysiol ; 10(2): 193-202, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38069975

RESUMEN

BACKGROUND: Risks of radiofrequency catheter ablation for ventricular arrhythmias include emboli and bleeding complications but data on antithrombotic regimens are limited and guidelines do not specify a systematic approach. OBJECTIVES: This study sought to assess embolic and bleeding complications in relation to pre-periprocedure and post-periprocedure antithrombotic regimens. METHODS: Prospective assessment for complications was performed for 663 endocardial radiofrequency catheter ablation procedures in 616 consecutive patients (median age 64 years [Q1-Q3: 54-73 years], 70.3% men, 71.6% with cardiomyopathy, 44.5% with sustained ventricular tachycardia). RESULTS: There were 2 strokes (0.3%; 95% CI: 0.0%-0.8%), 1 transient ischemic attack (0.15%), and 2 pulmonary emboli (0.3%). There were 39 bleeding complications (5.9%) including 11 pericardial effusions (1.7%), and 28 related to vascular access (4.2%). Consistent with the prevalence of coronary artery disease (47.5%), atrial fibrillation (30.0%), and prior stroke (10.6%), preprocedure, 464 patients (70.0%) were taking antithrombotic agents including 220 (33.2%) taking aspirin alone (ASA), and 163 (24.6%) taking warfarin or a direct acting oral anticoagulant (DOAC). Preprocedure non-ASA antiplatelet use (OR: 2.846; P = 0.011) and DOAC use (OR: 2.585; P = 0.032) were associated with risk of bleeding complications. Following ablation, 49.8% of patients were treated with ASA 325 mg/d and 30.3% received DOACs or warfarin. New DOAC or warfarin administration was initiated in only 6.6% of patients. Overall, 39.7% of patients continued the same preprocedure antithrombotic regimen. CONCLUSIONS: Stroke is a rare complication of radiofrequency catheter ablation for ventricular arrhythmia using ASA 325 mg/d as a minimal postprocedure regimen with more potent regimens for selected patients.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Warfarina/efectos adversos , Anticoagulantes/efectos adversos , Hemorragia/etiología , Hemorragia/inducido químicamente , Fibrinolíticos , Estudios Prospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Fibrilación Atrial/cirugía , Aspirina/efectos adversos
12.
Circ Arrhythm Electrophysiol ; 17(6): e012635, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38804141

RESUMEN

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% (P<0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P=0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P=0.004, and odds ratio, 29.93; P<0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.


Asunto(s)
Ablación por Catéter , Ecocardiografía , Solución Salina , Vapor , Taquicardia Ventricular , Irrigación Terapéutica , Humanos , Masculino , Femenino , Solución Salina/administración & dosificación , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico por imagen , Anciano , Embolia Aérea/prevención & control , Embolia Aérea/etiología , Embolia Aérea/diagnóstico por imagen , Resultado del Tratamiento , Factores de Riesgo , Valor Predictivo de las Pruebas , Impedancia Eléctrica
13.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38471835

RESUMEN

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Angiopoyetina 2 , Interleucina-6 , Modelos Estadísticos , Volumen Sistólico , Remodelación Ventricular , Factores de Riesgo , Pronóstico , Recurrencia , Función Ventricular Izquierda , Biomarcadores , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
14.
Artículo en Inglés | MEDLINE | ID: mdl-39243256

RESUMEN

BACKGROUND: Patients with rare, pathogenic cardiomyopathy (CM) and arrhythmia variants can present with atrial fibrillation (AF). The efficacy of AF ablation in these patients is unknown. OBJECTIVE: This study tested the hypotheses that: 1) patients with a pathogenic variant in any CM or arrhythmia gene have increased recurrence following AF ablation; and 2) patients with a pathogenic variant associated with a specific gene group (arrhythmogenic left ventricular CM [ALVC], arrhythmogenic right ventricular CM, dilated CM, hypertrophic CM, or a channelopathy) have increased recurrence. METHODS: We performed a prospective, observational, cohort study of patients who underwent AF catheter ablation and whole exome sequencing. The primary outcome measure was ≥30 seconds of any atrial tachyarrhythmia that occurred after a 90-day blanking period. RESULTS: Among 1,366 participants, 109 (8.0%) had a pathogenic or likely pathogenic (P/LP) variant in a CM or arrhythmia gene. In multivariable analysis, the presence of a P/LP variant in any gene was not significantly associated with recurrence (HR 1.15; 95% CI 0.84-1.60; P = 0.53). P/LP variants in the ALVC gene group, predominantly LMNA, were associated with increased recurrence (n = 10; HR 3.75; 95% CI 1.84-7.63; P < 0.001), compared with those in the arrhythmogenic right ventricular CM, dilated CM, hypertrophic CM, and channelopathy gene groups. Participants with P/LP TTN variants (n = 46) had no difference in recurrence compared with genotype-negative-controls (HR 0.93; 95% CI 0.54-1.59; P = 0.78). CONCLUSIONS: Our results support the use of AF ablation for most patients with rare pathogenic CM or arrhythmia variants, including TTN. However, patients with ALVC variants, such as LMNA, may be at a significantly higher risk for arrhythmia recurrence.

15.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1475-1486, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37278684

RESUMEN

BACKGROUND: We previously reported feasibility of irrigated needle ablation (INA) with a retractable 27-G end-hole needle catheter to treat nonendocardial ventricular arrhythmia substrate, an important cause of ablation failure. OBJECTIVES: The purpose of this study was to report outcomes and complications in our entire INA-treated population. METHODS: Patients with recurrent sustained monomorphic ventricular tachycardia (VT) or high-density premature ventricular contractions (PVCs) despite radiofrequency ablation were prospectively enrolled at 4 centers. Endpoints included a 70% decrease in VT frequency or PVC burden decrease to <5,000/24 h at 6 months. RESULTS: INA was performed in 111 patients (median: 2 failed prior ablations, 71% nonischemic heart disease, and left ventricular ejection fraction 36% ± 14%). INA acutely abolished targeted PVCs in 33 of 37 patients (89%), and PVCs were reduced to <5,000/day in 29 patients (78%). During 6-month follow-up, freedom from hospitalization was observed in 50 of 72 patients with VT (69%), and improvement or abolition of VT occurred in 47%. All patients received multiple INA applications, with more in the VT group than in the PVC group (median: 12 [IQR: 7-19] vs 7 [5-15]; P < 0.01). After INA, additional endocardial standard radiofrequency ablation was required in 23% of patients. Adverse events included 4 pericardial effusions (3.5%), 3 cases of (anticipated) atrioventricular block (2.6%), and 3 heart failure exacerbations (2.6%). During 6-month follow-up, 5 deaths occurred; none were procedure-related. CONCLUSIONS: INA achieves improved arrhythmia control in 78% of patients with PVCs and avoids hospitalization in 69% of patients with VT refractory to standard ablation at 6-month follow-up. Procedural risks are acceptable. (Intramural Needle Ablation for Ablation of Recurrent Ventricular Tachycardia, NCT01791543; Intramural Needle Ablation for the Treatment of Refractory Ventricular Arrhythmias, NCT03204981).


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Ablación por Catéter/efectos adversos , Volumen Sistólico , Función Ventricular Izquierda
16.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1147-1157, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37495323

RESUMEN

BACKGROUND: Experimental evidence suggests genetic variation in 4q25/PITX2 modulates pulmonary vein (PV) myocardial sleeve length. Although PV sleeves are the main target of atrial fibrillation (AF) ablation, little is known about the association between different PV sleeve characteristics with ablation outcomes. OBJECTIVES: This study sought to evaluate the association between clinical and genetic (4q25) risk factors with PV sleeve length in humans, and to evaluate the association between PV sleeve length and recurrence after AF ablation. METHODS: In a prospective, observational study of patients undergoing de novo AF ablation, PV sleeve length was measured using electroanatomic voltage mapping before ablation. The sentinel 4q25 AF susceptibility single nucleotide polymorphism, rs2200733, was genotyped. The primary analysis tested the association between clinical and genetic (4q25) risk factors with PV sleeve length using a multivariable linear regression model. Covariates included age, sex, body mass index, height, and persistent AF. The association between PV sleeve length and atrial arrhythmia recurrence (>30 seconds) was tested using a multivariable Cox proportional hazards model. RESULTS: Between 2014 and 2019, 197 participants were enrolled (median age 63 years [IQR: 55 to 70 years], 133 male [67.5%]). In multivariable modeling, men were found to have PV sleeves 2.94 mm longer than women (95% CI: 0.99-4.90 mm; P < 0.001). Sixty participants (30.5%) had one 4q25 risk allele and 6 (3.1%) had 2 alleles. There was no association between 4q25 genotype and PV sleeve length. Forty-six participants (23.4%) experienced arrhythmia recurrence within 3 to 12 months, but there was no association between recurrence and PV sleeve length. CONCLUSIONS: Common genetic variation at 4q25 was not associated with PV sleeve length and PV sleeve length was not associated with ablation outcomes. Men did have longer PV sleeves than women, but more research is needed to define the potential clinical significance of this observation.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/genética , Fibrilación Atrial/cirugía , Genotipo , Estudios Prospectivos , Venas Pulmonares/cirugía , Factores de Riesgo , Anciano , Proteína del Homeodomínio PITX2
17.
Heart Rhythm ; 18(7): 1153-1161, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33957090

RESUMEN

BACKGROUND: Watchman 2.5 (Boston Scientific Inc, Marlborough, MA) implant success approaches 95% in registries, yet many patients are not attempted because of complex left atrial appendage (LAA) anatomy. Watchman FLX can expand the range of ostium width (14-31.5 mm) and depth available for LAA closure. OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of Watchman FLX in patients with a failed Watchman 2.5 attempt or prohibitive LAA anatomy. METHODS: The roll-in (n = 58) and primary effectiveness (n = 400) cohorts of the PINNACLE FLX trial comprised the study population. Subjects were identified who previously failed implantation of Watchman 2.5 (n = 11) or were not attempted because of prohibitive LAA anatomy (n = 88). Demographic characteristics, implant procedure details, and TEE follow-up data were compared to controls composed of enrollees not meeting these criteria (n = 359). RESULTS: Watchman FLX LAA closure was successfully implanted in all subjects with a prior failed Watchman 2.5 attempt (n = 11 of 11). Subjects with previously failed Watchman 2.5 were more likely to receive a 35 mm FLX device than controls (27.3% vs 7.3%; P = .047). Patients with prohibitive anatomy had smaller LAA dimensions than did controls (diameter 18.0 ± 4 mm vs 20.4 ± 3 mm; P < .001 and length 23.7 ± 5 mm vs 28.9 ± 5 mm; P < .001). There was no difference in age, sex, CHA2DS2-VASc score, HAS-BLED score, or primary efficacy between cohorts. Transesophageal echocardiography (TEE) at 12 months showed zero leak in 90.9% in the failed Watchman 2.5 cohort, 91.3% in the prohibitive anatomy cohort, and 89.5% in the control cohort (P = .84). Overall and cardiovascular mortality was lower in the prohibitive anatomy cohort (1.2% vs 8.8% in controls; P = .02). CONCLUSION: Watchman FLX implantation in patients with a prior failed Watchman 2.5 attempt or prohibitive LAA anatomy remained safe and highly effective. The association of reduced overall mortality with smaller LAA dimension warrants future study.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Sistema de Registros , Accidente Cerebrovascular/prevención & control , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Accidente Cerebrovascular/etiología , Factores de Tiempo
18.
JACC Clin Electrophysiol ; 7(10): 1254-1263, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34217656

RESUMEN

OBJECTIVES: This study aimed to review the utility of quinidine in patients presenting with recurrent sustained ventricular arrhythmia (VA) and limited antiarrhythmic drug (AAD) options. BACKGROUND: Therapeutic options are often limited in patients with structural heart disease and recurrent VAs. Quinidine has an established role in rare arrhythmic syndromes, but its potential use in other difficult VAs has not been assessed in the present era. METHODS: We performed a retrospective analysis of 37 patients who had in-hospital quinidine initiation after multiple other therapies failed for VA suppression at our tertiary referral center. Clinical data and outcomes were obtained from the medical record. RESULTS: Of 30 patients with in-hospital quantifiable VA episodes, quinidine reduced acute VA from a median of 3 episodes (interquartile range [IQR]: 2 to 7.5) to 0 (IQR: 0 to 0.5) during medians of 3 days before and 4 days after quinidine initiation (p < 0.001). VA events decreased from a median of 10.5 episodes per day (IQR: 5 to 15) to 0.5 episodes (IQR: 0 to 4) after quinidine initiation in the 12 patients presenting with electrical storm (p = 0.004). Among the 24 patients discharged on quinidine, 13 (54.2%) had VA recurrence during a median of 138 days. Adverse effects in 9 of the 37 patients (24.3%) led to drug discontinuation, most commonly gastrointestinal intolerance. CONCLUSIONS: In patients with recurrent VAs and structural heart disease who have limited treatment options, quinidine can be useful, particularly as a short-term therapy.


Asunto(s)
Quinidina , Fibrilación Ventricular , Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/tratamiento farmacológico , Humanos , Quinidina/uso terapéutico , Estudios Retrospectivos , Fibrilación Ventricular/tratamiento farmacológico
19.
Card Electrophysiol Clin ; 12(3): 313-319, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32771185

RESUMEN

Catheter ablation can effectively reduce the frequency of ventricular tachycardia in ischemic cardiomyopathy by ablating sites of reentry within complex regions of myocardial scar. In cases of near transmural infarction, this arrhythmia substrate may be nearer the epicardium than the endocardium, and epicardial ablation may be necessary. An epicardial substrate location can potentially be predicted by imaging that suggests transmural infarction. Percutaneous epicardial ablation improves outcomes in selected patients, but is higher risk and avoided in patients with prior coronary artery bypass grafting.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Mapeo Epicárdico , Isquemia Miocárdica , Taquicardia Ventricular , Técnicas de Imagen Cardíaca , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/cirugía , Humanos , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/cirugía , Pericardio/diagnóstico por imagen , Pericardio/cirugía , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA