Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
BMJ Open ; 11(3): e042547, 2021 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-33707268

RESUMEN

OBJECTIVES: Paediatric pneumonia burden and mortality are highest in low-income and middle-income countries (LMIC). Paediatric lung ultrasound (LUS) has emerged as a promising diagnostic tool for pneumonia in LMIC. Despite a growing evidence base for LUS use in paediatric pneumonia diagnosis, little is known about its potential for successful implementation in LMIC. Our objectives were to evaluate the feasibility, usability and acceptability of LUS in the diagnosis of paediatric pneumonia. DESIGN: Prospective qualitative study using semistructured interviews SETTING: Two referral hospitals in Mozambique and Pakistan PARTICIPANTS: A total of 21 healthcare providers (HCPs) and 20 caregivers were enrolled. RESULTS: HCPs highlighted themes of limited resource availability for the feasibility of LUS implementation, including perceived high cost of equipment, maintenance demands, time constraints and limited trained staff. HCPs emphasised the importance of policymaker support and caregiver acceptance for long-term success. HCP perspectives of usability highlighted ease of use and integration into existing workflow. HCPs and caregivers had positive attitudes towards LUS with few exceptions. Both HCPs and caregivers emphasised the potential for rapid, improved diagnosis of paediatric respiratory conditions using LUS. CONCLUSIONS: This was the first study to evaluate HCP and caregiver perspectives of paediatric LUS through qualitative analysis. Critical components impacting feasibility, usability and acceptability of LUS for paediatric pneumonia diagnosis in LMIC were identified for initial deployment. Future research should explore LUS sustainability, with a particular focus on quality control, device maintenance and functionality and adoption of the new technology within the health system. This study highlights the need to engage both users and recipients of new technology early in order to adapt future interventions to the local context for successful implementation. TRIAL REGISTRATION NUMBER: NCT03187067.


Asunto(s)
Cuidadores , Neumonía , Niño , Estudios de Factibilidad , Personal de Salud , Humanos , Pulmón/diagnóstico por imagen , Mozambique , Pakistán , Neumonía/diagnóstico por imagen , Estudios Prospectivos , Ultrasonografía
2.
Sci Rep ; 11(1): 6262, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33737572

RESUMEN

Lung ultrasound (LUS) is a promising point-of-care imaging technology for diagnosing and managing pneumonia. We sought to explore serial LUS examinations in children with chest-indrawing pneumonia in resource-constrained settings and compare their clinical and LUS imaging courses longitudinally. We conducted a prospective, observational study among children aged 2 through 23 months with World Health Organization Integrated Management of Childhood Illness chest-indrawing pneumonia and among children without fast breathing, chest indrawing or fever (no pneumonia cohort) at 2 district hospitals in Mozambique and Pakistan. We assessed serial LUS at enrollment, 2, 6, and 14 days, and performed a secondary analysis of enrolled children's longitudinal clinical and imaging courses. By Day 14, the majority of children with chest-indrawing pneumonia and consolidation on enrollment LUS showed improvement on follow-up LUS (100% in Mozambique, 85.4% in Pakistan) and were clinically cured (100% in Mozambique, 78.0% in Pakistan). In our cohort of children with chest-indrawing pneumonia, LUS imaging often reflected the clinical course; however, it is unclear how serial LUS would inform the routine management of non-severe chest-indrawing pneumonia.


Asunto(s)
Pulmón/diagnóstico por imagen , Neumonía/diagnóstico por imagen , Neumonía/epidemiología , Pruebas en el Punto de Atención , Tórax/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Lactante , Estudios Longitudinales , Masculino , Mozambique/epidemiología , Pakistán/epidemiología , Proyectos Piloto , Estudios Prospectivos , Ultrasonografía/métodos
3.
Pediatr Pulmonol ; 56(2): 551-560, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33205892

RESUMEN

INTRODUCTION: Improved pneumonia diagnostics are needed in low-resource settings (LRS); lung ultrasound (LUS) is a promising diagnostic technology for pneumonia. The objective was to compare LUS versus chest radiograph (CXR), and among LUS interpreters, to compare expert versus limited training with respect to interrater reliability. METHODS: We conducted a prospective, observational study among children with World Health Organization (WHO) Integrated Management of Childhood Illness (IMCI) chest-indrawing pneumonia at two district hospitals in Mozambique and Pakistan, and assessed LUS and CXR examinations. The primary endpoint was interrater reliability between LUS and CXR interpreters for pneumonia diagnosis among children with WHO IMCI chest-indrawing pneumonia. RESULTS: Interrater reliability was excellent for expert LUS interpreters, but poor to moderate for expert CXR interpreters and onsite LUS interpreters with limited training. CONCLUSIONS: Among children with WHO IMCI chest-indrawing pneumonia, expert interpreters may achieve substantially higher interrater reliability for LUS compared to CXR, and LUS showed potential as a preferred reference standard. For point-of-care LUS to be successfully implemented for the diagnosis and management of pneumonia in LRS, the clinical environment and amount of appropriate user training will need to be understood and addressed.


Asunto(s)
Pulmón/diagnóstico por imagen , Neumonía/diagnóstico por imagen , Femenino , Humanos , Lactante , Masculino , Mozambique , Pakistán , Radiografía Torácica , Reproducibilidad de los Resultados , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA