Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 967
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 388(22): 2037-2048, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36876756

RESUMEN

BACKGROUND: Data from a 5-year follow-up of outcomes after transcatheter edge-to-edge repair of severe mitral regurgitation, as compared with outcomes after maximal doses of guideline-directed medical therapy alone, in patients with heart failure are now available. METHODS: We randomly assigned patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy to undergo transcatheter edge-to-edge repair plus receive medical therapy (device group) or to receive medical therapy alone (control group) at 78 sites in the United States and Canada. The primary effectiveness end point was all hospitalizations for heart failure through 2 years of follow-up. The annualized rate of all hospitalizations for heart failure, all-cause mortality, the risk of death or hospitalization for heart failure, and safety, among other outcomes, were assessed through 5 years. RESULTS: Of the 614 patients enrolled in the trial, 302 were assigned to the device group and 312 to the control group. The annualized rate of hospitalization for heart failure through 5 years was 33.1% per year in the device group and 57.2% per year in the control group (hazard ratio, 0.53; 95% confidence interval [CI], 0.41 to 0.68). All-cause mortality through 5 years was 57.3% in the device group and 67.2% in the control group (hazard ratio, 0.72; 95% CI, 0.58 to 0.89). Death or hospitalization for heart failure within 5 years occurred in 73.6% of the patients in the device group and in 91.5% of those in the control group (hazard ratio, 0.53; 95% CI, 0.44 to 0.64). Device-specific safety events within 5 years occurred in 4 of 293 treated patients (1.4%), with all the events occurring within 30 days after the procedure. CONCLUSIONS: Among patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite guideline-directed medical therapy, transcatheter edge-to-edge repair of the mitral valve was safe and led to a lower rate of hospitalization for heart failure and lower all-cause mortality through 5 years of follow-up than medical therapy alone. (Funded by Abbott; COAPT ClinicalTrials.gov number, NCT01626079.).


Asunto(s)
Cateterismo Cardíaco , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios de Seguimiento , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
2.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37874020

RESUMEN

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estudios de Seguimiento , Readmisión del Paciente , Insuficiencia Cardíaca/etiología
3.
Circulation ; 149(10): 734-743, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-37874908

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in patients undergoing transcatheter aortic valve replacement (TAVR) and is associated with increased risk of bleeding and stroke. While left atrial appendage occlusion (LAAO) is approved as an alternative to anticoagulants for stroke prevention in patients with AF, placement of these devices in patients with severe aortic stenosis, or when performed at the same time as TAVR, has not been extensively studied. METHODS: WATCH-TAVR (WATCHMAN for Patients with AF Undergoing TAVR) was a multicenter, randomized trial evaluating the safety and effectiveness of concomitant TAVR and LAAO with WATCHMAN in AF patients. Patients were randomized 1:1 to TAVR + LAAO or TAVR + medical therapy. WATCHMAN patients received anticoagulation for 45 days followed by dual antiplatelet therapy until 6 months. Anticoagulation was per treating physician preference for patients randomized to TAVR + medical therapy. The primary noninferiority end point was all-cause mortality, stroke, and major bleeding at 2 years between the 2 strategies. RESULTS: The study enrolled 349 patients (177 TAVR + LAAO and 172 TAVR + medical therapy) between December 2017 and November 2020 at 34 US centers. The mean age of patients was 81 years, and the mean scores for CHA2DS2-VASc and HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly) were 4.9 and 3.0, respectively. At baseline, 85.4% of patients were taking anticoagulants and 71.3% patients were on antiplatelet therapy. The cohorts were well-balanced for baseline characteristics. The incremental LAAO procedure time was 38 minutes, and the median contrast volume used for combined procedures was 119 mL versus 70 mL with TAVR alone. At the 24-month follow-up, 82.5% compared with 50.8% of patients were on any antiplatelet therapy, and 13.9% compared with 66.7% of patients were on any anticoagulation therapy in TAVR + LAAO compared with TAVR + medical therapy group, respectively. For the composite primary end point, TAVR + LAAO was noninferior to TAVR + medical therapy (22.7 versus 27.3 events per 100 patient-years for TAVR + LAAO and TAVR + medical therapy, respectively; hazard ratio, 0.86 [95% CI, 0.60-1.22]; Pnoninferiority<0.001). CONCLUSIONS: Concomitant WATCHMAN LAAO and TAVR is noninferior to TAVR with medical therapy in severe aortic stenosis patients with AF. The increased complexity and risks of the combined procedure should be considered when concomitant LAAO is viewed as an alternative to medical therapy for patients with AF undergoing TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03173534.


Asunto(s)
Estenosis de la Válvula Aórtica , Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Apéndice Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
4.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36121045

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Implantación de Prótesis , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Ataque Isquémico Transitorio/etiología , Implantación de Prótesis/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
5.
Eur Heart J ; 45(21): 1890-1900, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38270189

RESUMEN

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Intervención Coronaria Percutánea , Resultado del Tratamiento , Factores de Riesgo
6.
Circulation ; 147(21): 1594-1605, 2023 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-37154049

RESUMEN

BACKGROUND: In patients with severe symptomatic aortic stenosis at low surgical risk, transfemoral transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve has been shown to reduce the composite of death, stroke, or rehospitalization at 2-year follow-up compared with surgical aortic valve replacement (SAVR). Whether TAVR is cost-effective compared with SAVR for low-risk patients remains uncertain. METHODS: Between 2016 and 2017, 1000 low-risk patients with aortic stenosis were randomly assigned to TAVR with the SAPIEN 3 valve or SAVR in the PARTNER 3 trial (Placement of Aortic Transcatheter Valves). Of these patients, 929 underwent valve replacement, were enrolled in the United States, and were included in the economic substudy. Procedural costs were estimated using measured resource use. Other costs were determined by linkage with Medicare claims or by regression models when linkage was not feasible. Health utilities were estimated using the EuroQOL 5-item questionnaire. With the use of a Markov model informed by in-trial data, lifetime cost-effectiveness from the perspective of the US health care system was estimated in terms of cost per quality-adjusted life-year gained. RESULTS: Although procedural costs were nearly $19 000 higher with TAVR, total index hospitalization costs were only $591 more with TAVR compared with SAVR. Follow-up costs were lower with TAVR such that TAVR led to 2-year cost savings of $2030/patient compared with SAVR (95% CI, -$6222 to $1816) and a gain of 0.05 quality-adjusted life-years (95% CI, -0.003 to 0.102). In our base-case analysis, TAVR was projected to be an economically dominant strategy with a 95% probability that the incremental cost-effectiveness ratio for TAVR would be <$50 000/quality-adjusted life-year gained (consistent with high economic value from a US health care perspective). These findings were sensitive to differences in long-term survival, however, such that a modest long-term survival advantage with SAVR would render SAVR cost-effective (although not cost saving) compared with TAVR. CONCLUSIONS: For patients with severe aortic stenosis and low surgical risk similar to those enrolled in the PARTNER 3 trial, transfemoral TAVR with the SAPIEN 3 valve is cost saving compared with SAVR at 2 years and is projected to be economically attractive in the long run as long as there are no substantial differences in late death between the 2 strategies. Long-term follow-up will be critical to ultimately determine the preferred treatment strategy for low-risk patients from both a clinical and economic perspective.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Medicare , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Factores de Riesgo
7.
Lancet ; 402(10412): 1529-1540, 2023 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-37660719

RESUMEN

BACKGROUND: With increasing numbers of patients undergoing transcatheter aortic valve replacement (TAVR), data on management of failed TAVR, including repeat TAVR procedure, are needed. The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry. METHODS: This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9, 2011, to Dec 30, 2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves (redo-TAVR) or native aortic valves (native-TAVR). Procedural, echocardiographic, and clinical outcomes were compared between redo-TAVR and native-TAVR cohorts using propensity score matching. FINDINGS: Among 350 591 patients (1320 redo-TAVR; 349 271 native-TAVR), 1320 propensity-matched pairs of patients undergoing redo-TAVR and native-TAVR were analysed (redo-TAVR cohort: mean age 78 years [SD 9]; 559 [42·3%] of 1320 female, 761 [57·7%] male; mean predicted surgical risk of 30-day mortality 8·1%). The rates of procedural complications of redo-TAVR were low (coronary compression or obstruction: four [0·3%] of 1320; intraprocedural death: eight [0·6%] of 1320; conversion to open heart surgery: six [0·5%] of 1319) and similar to native-TAVR. There was no significant difference between redo-TAVR and native-TAVR populations in death at 30 days (4·7% vs 4·0%, p=0·36) or 1 year (17·5% vs 19·0%, p=0·57), and stroke at 30 days (2·0% vs 1·9%, p=0·84) or 1 year (3·2% vs 3·5%, p=0·80). Redo-TAVR reduced aortic valve gradients at 1 year, although they were higher in the redo-TAVR group compared with the native-TAVR group (15 mm Hg vs 12 mm Hg; p<0·0001). Moderate or severe aortic regurgitation rates were similar between redo-TAVR and native-TAVR groups at 1 year (1·8% vs 3·3%, p=0·18). Death or stroke after redo-TAVR were not significantly affected by the timing of redo-TAVR (before or after 1 year of index TAVR), or by index transcatheter valve type (balloon-expandable or non-balloon-expandable). INTERPRETATION: Redo-TAVR with balloon-expandable valves effectively treated dysfunction of the index TAVR procedure with low procedural complication rates, and death and stroke rates similar to those in patients with a similar clinical profile and predicted risk undergoing TAVR for native aortic valve stenosis. Redo-TAVR with balloon-expandable valves might be a reasonable treatment for failed TAVR in selected patients. FUNDING: Edwards Lifesciences.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Accidente Cerebrovascular/etiología , Sistema de Registros , Factores de Riesgo , Diseño de Prótesis
8.
Am Heart J ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39032584

RESUMEN

BACKGROUND: Skeletal muscle mass (SMM) plays a crucial role in risk assessment in transcatheter aortic valve replacement (TAVR) candidates, yet it remains underutilized. Traditional methods focus on weakness or performance but omit SMM. This study compared traditional and novel markers of sarcopenia and frailty in terms of their ability to predict adverse outcomes post-TAVR. METHODS: Three risk models were evaluated for the composite outcome of perioperative complications, 1-year rehospitalization, or 1-year mortality: (1) sarcopenia by combining low muscle mass (LMM) and weakness/performance assessed by hand grip strength or gait speed; (2) frailty by an Adapted Green score; and (3) frailty by the Green-SMI score incorporating LMM by multi-level opportunistic pre-TAVR thoracic CT segmentation. RESULTS: In this study we included 184 eligible patients from January to December of 2018, (96.7%) of which were balloon expandable valves. The three risk models identified 22.8% patients as sarcopenic, 63.6% as frail by the Adapted Green score, and 53.8% as frail by the Green-SMI score. There were higher rates of the composite outcome in patients with sarcopenia (54.8%) and frailty (41.9% with the Adapted Green and 50.5% with the Green-SMI score) compared to their non-sarcopenic (30.3%) and non-frail counterparts (25.4% with the Adapted Green and 18.8% with the Green-SMI score). Sarcopenia and frailty by Green-SMI, but not by the Adapted Green, were associated with higher risks of the composite outcome on multivariable adjustment (HR 2.2 [95% CI: 1.25-4.02], p=0.007 and HR 3.4 [95% CI: 1.75-6.65], p<0.001, respectively). CONCLUSIONS: The integration of pre-operative CT-based SMM to a frailty score significantly improves the prediction of adverse outcomes in patients undergoing TAVR.

9.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38703375

RESUMEN

AIMS: Ablation of monomorphic ventricular tachycardia (MMVT) has been shown to reduce shock frequency and improve survival. We aimed to compare cause-specific risk factors for MMVT and polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) and to develop predictive models. METHODS AND RESULTS: The multicentre retrospective cohort study included 2668 patients (age 63.1 ± 13.0 years; 23% female; 78% white; 43% non-ischaemic cardiomyopathy; left ventricular ejection fraction 28.2 ± 11.1%). Cox models were adjusted for demographic characteristics, heart failure severity and treatment, device programming, and electrocardiogram metrics. Global electrical heterogeneity was measured by spatial QRS-T angle (QRSTa), spatial ventricular gradient elevation (SVGel), azimuth, magnitude (SVGmag), and sum absolute QRST integral (SAIQRST). We compared the out-of-sample performance of the lasso and elastic net for Cox proportional hazards and the Fine-Gray competing risk model. During a median follow-up of 4 years, 359 patients experienced their first sustained MMVT with appropriate implantable cardioverter-defibrillator (ICD) therapy, and 129 patients had their first PVT/VF with appropriate ICD shock. The risk of MMVT was associated with wider QRSTa [hazard ratio (HR) 1.16; 95% confidence interval (CI) 1.01-1.34], larger SVGel (HR 1.17; 95% CI 1.05-1.30), and smaller SVGmag (HR 0.74; 95% CI 0.63-0.86) and SAIQRST (HR 0.84; 95% CI 0.71-0.99). The best-performing 3-year competing risk Fine-Gray model for MMVT [time-dependent area under the receiver operating characteristic curve (ROC(t)AUC) 0.728; 95% CI 0.668-0.788] identified high-risk (> 50%) patients with 75% sensitivity and 65% specificity, and PVT/VF prediction model had ROC(t)AUC 0.915 (95% CI 0.868-0.962), both satisfactory calibration. CONCLUSION: We developed and validated models to predict the competing risks of MMVT or PVT/VF that could inform procedural planning and future randomized controlled trials of prophylactic ventricular tachycardia ablation. CLINICAL TRIAL REGISTRATION: URL:www.clinicaltrials.gov Unique identifier:NCT03210883.


Asunto(s)
Desfibriladores Implantables , Prevención Primaria , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Femenino , Masculino , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Persona de Mediana Edad , Estudios Retrospectivos , Prevención Primaria/métodos , Factores de Riesgo , Medición de Riesgo , Anciano , Fibrilación Ventricular/prevención & control , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia , Resultado del Tratamiento , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Ablación por Catéter , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología
10.
Vasc Med ; 29(2): 125-134, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38334067

RESUMEN

BACKGROUND: Postacute sequelae of COVID-19 (PASC), also referred to as "Long COVID", sometimes follows COVID-19, a disease caused by SARS-CoV-2. Although SARS-CoV-2 is well known to promote a prothrombotic state, less is known about the thrombosis risk in PASC. Our objective was to evaluate platelet function and thrombotic potential in patients following recovery from SARS-CoV-2, but with clear symptoms of patients with PASC. METHODS: patients with PASC and matched healthy controls were enrolled in the study on average 15 months after documented SARS-CoV-2 infection. Platelet activation was evaluated by light transmission aggregometry (LTA) and flow cytometry in response to platelet surface receptor agonists. Thrombosis in platelet-deplete plasma was evaluated by Factor Xa activity. A microfluidics system assessed thrombosis in whole blood under shear stress conditions. RESULTS: A mild increase in platelet aggregation in patients with PASC through the thromboxane receptor was observed, and platelet activation through the glycoprotein VI (GPVI) receptor was decreased in patients with PASC compared to age- and sex-matched healthy controls. Thrombosis under shear conditions as well as Factor Xa activity were reduced in patients with PASC. Plasma from patients with PASC was an extremely potent activator of washed, healthy platelets - a phenomenon not observed when stimulating healthy platelets after incubation with plasma from healthy individuals. CONCLUSIONS: patients with PASC show dysregulated responses in platelets and coagulation in plasma, likely caused by a circulating molecule that promotes thrombosis. A hitherto undescribed protective response appears to exist in patients with PASC to counterbalance ongoing thrombosis that is common to SARS-CoV-2 infection.


Asunto(s)
COVID-19 , Trombosis , Humanos , COVID-19/complicaciones , SARS-CoV-2 , Factor Xa , Coagulación Sanguínea , Progresión de la Enfermedad , Trombosis/etiología
11.
Eur Heart J ; 44(10): 836-852, 2023 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-36660821

RESUMEN

AIMS: Additional randomized clinical trial (RCT) data comparing transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) is available, including longer term follow-up. A meta-analysis comparing TAVI to SAVR was performed. A pragmatic risk classification was applied, partitioning lower-risk and higher-risk patients. METHODS AND RESULTS: The main endpoints were death, strokes, and the composite of death or disabling stroke, occurring at 1 year (early) or after 1 year (later). A random-effects meta-analysis was performed. Eight RCTs with 8698 patients were included. In lower-risk patients, at 1 year, the risk of death was lower after TAVI compared with SAVR [relative risk (RR) 0.67; 95% confidence interval (CI) 0.47 to 0.96, P = 0.031], as was death or disabling stroke (RR 0.68; 95% CI 0.50 to 0.92, P = 0.014). There were no differences in strokes. After 1 year, in lower-risk patients, there were no significant differences in all main outcomes. In higher-risk patients, there were no significant differences in main outcomes. New-onset atrial fibrillation, major bleeding, and acute kidney injury occurred less after TAVI; new pacemakers, vascular complications, and paravalvular leak occurred more after TAVI. CONCLUSION: In lower-risk patients, there was an early mortality reduction with TAVI, but no differences after later follow-up. There was also an early reduction in the composite of death or disabling stroke, with no difference at later follow-up. There were no significant differences for higher-risk patients. Informed therapy decisions may be more dependent on the temporality of events or secondary endpoints than the long-term occurrence of main clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
12.
Circulation ; 146(17): 1297-1309, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-36154237

RESUMEN

BACKGROUND: Assessing hospital performance for cardiac surgery necessitates consistent and valid care quality metrics. The association of hospital-level risk-standardized home time for cardiac surgeries with other performance metrics such as mortality rate, readmission rate, and annual surgical volume has not been evaluated previously. METHODS: The study included Medicare beneficiaries who underwent isolated or concomitant coronary artery bypass graft, aortic valve, or mitral valve surgery from January 1, 2013, to October 1, 2019. Hospital-level performance metrics of annual surgical volume, 90-day risk-standardized mortality rate, 90-day risk-standardized readmission rate, and 90-day risk-standardized home time were estimated starting from the day of surgery using generalized linear mixed models with a random intercept for the hospital. Correlations between the performance metrics were assessed using the Pearson correlation coefficient. Patient-level clinical outcomes were also compared across hospital quartiles by 90-day risk-standardized home time. Last, the temporal stability of performance metrics for each hospital during the study years was also assessed. RESULTS: Overall, 919 698 patients (age 74.2±5.8 years, 32% women) were included from 1179 hospitals. Median 90-day risk-standardized home time was 71.2 days (25th-75th percentile, 66.5-75.6), 90-day risk-standardized readmission rate was 26.0% (19.5%-35.7%), and 90-day risk-standardized mortality rate was 6.0% (4.0%-8.8%). Across 90-day home time quartiles, a graded decline was observed in the rates of in-hospital, 90-day, and 1-year mortality, and 90-day and 1-year readmission. Ninety-day home time had a significant positive correlation with annual surgical volume (r=0.31; P<0.001) and inverse correlation with 90-day risk-standardized readmission rate (r=-0.40; P <0.001) and 90-day risk-standardized mortality rate (r=-0.60; P <0.001). Use of 90-day home time as a performance metric resulted in a meaningful reclassification in performance ranking of 22.8% hospitals compared with annual surgical volume, 11.6% compared with 90-day risk-standardized mortality rate, and 19.9% compared with 90-day risk-standardized readmission rate. Across the 7 years of the study period, 90-day home time demonstrated the most temporal stability of the hospital performance metrics. CONCLUSIONS: Ninety-day risk-standardized home time is a feasible, comprehensive, patient-centered metric to assess hospital-level performance in cardiac surgery with greater temporal stability than mortality and readmission measures.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Readmisión del Paciente , Estados Unidos/epidemiología , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Medicare , Hospitales , Puente de Arteria Coronaria
13.
N Engl J Med ; 382(9): 799-809, 2020 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-31995682

RESUMEN

BACKGROUND: There are scant data on long-term clinical outcomes and bioprosthetic-valve function after transcatheter aortic-valve replacement (TAVR) as compared with surgical aortic-valve replacement in patients with severe aortic stenosis and intermediate surgical risk. METHODS: We enrolled 2032 intermediate-risk patients with severe, symptomatic aortic stenosis at 57 centers. Patients were stratified according to intended transfemoral or transthoracic access (76.3% and 23.7%, respectively) and were randomly assigned to undergo either TAVR or surgical replacement. Clinical, echocardiographic, and health-status outcomes were followed for 5 years. The primary end point was death from any cause or disabling stroke. RESULTS: At 5 years, there was no significant difference in the incidence of death from any cause or disabling stroke between the TAVR group and the surgery group (47.9% and 43.4%, respectively; hazard ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; P = 0.21). Results were similar for the transfemoral-access cohort (44.5% and 42.0%, respectively; hazard ratio, 1.02; 95% CI, 0.87 to 1.20), but the incidence of death or disabling stroke was higher after TAVR than after surgery in the transthoracic-access cohort (59.3% vs. 48.3%; hazard ratio, 1.32; 95% CI, 1.02 to 1.71). At 5 years, more patients in the TAVR group than in the surgery group had at least mild paravalvular aortic regurgitation (33.3% vs. 6.3%). Repeat hospitalizations were more frequent after TAVR than after surgery (33.3% vs. 25.2%), as were aortic-valve reinterventions (3.2% vs. 0.8%). Improvement in health status at 5 years was similar for TAVR and surgery. CONCLUSIONS: Among patients with aortic stenosis who were at intermediate surgical risk, there was no significant difference in the incidence of death or disabling stroke at 5 years after TAVR as compared with surgical aortic-valve replacement. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estudios de Cohortes , Ecocardiografía , Femenino , Estado de Salud , Humanos , Incidencia , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Complicaciones Posoperatorias/mortalidad , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
14.
Eur J Nucl Med Mol Imaging ; 50(13): 3910-3916, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37606857

RESUMEN

PURPOSE: Transthyretin cardiac amyloidosis (ATTR-CA) is thought to be prevalent in patients with severe aortic stenosis (AS) who are referred for transcatheter aortic valve replacement (TAVR). However, prior studies were published when TAVR was only offered to elderly, inoperable, and high-risk patients. The aim of this study was to reevaluate the prevalence of ATTR-CA in a contemporary TAVR population and identify high-risk features to guide referral for technetium-99 pyrophosphate scan (99mTc-PyP scan) screening. METHODS: Patients seen in a multidisciplinary TAVR clinic for severe AS 70 years and older were referred for a 99mTc-PyP scan to evaluate for ATTR-CA. The primary outcome was the percent with a positive scan. The discriminatory ability of high-risk features was assessed to develop a more judicious screening system. RESULTS: Over the study period, 380 patients underwent screening, and 20 patients (5.3%) had a positive scan, with 17 patients having confirmed ATTR-CA, 1 patient deferring confirmatory testing (combined 4.7%), 1 having light chain amyloidosis, and 1 negative on biopsy. Compared to other patient and echocardiographic measures, elevated NT-pro BNP (> 1000 ng/L) was the best discriminator on who should be referred for 99mTc-PyP scan screening, with a sensitivity of 90% and a negative predictive value of 99%. CONCLUSION: The prevalence of ATTR-CA may be lower in a contemporary TAVR population due to its expanded indication for low-risk patients. NT-pro BNP is a simple test that can improve screening yield and more judiciously guide screening for ATTR-CA in this at-risk population. Comparison of the original versus the proposed algorithm.


Asunto(s)
Neuropatías Amiloides Familiares , Cardiomiopatías , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/epidemiología , Cardiomiopatías/diagnóstico por imagen , Prevalencia , Cintigrafía , Prealbúmina
15.
Catheter Cardiovasc Interv ; 102(6): 1149-1153, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855217

RESUMEN

Left ventricular outflow tract (LVOT) obstruction from the displaced prosthetic anterior mitral leaflet is a life-threatening complication that can occur during valve-in-valve (ViV) transcatheter mitral valve replacement (TMVR). Laceration of the anterior mitral leaflet to prevent outflow obstruction is a well-established transcatheter technique to mitigate the risk of LVOT obstruction in high-risk anatomies. In this report, we present a novel transseptal technique of prosthetic leaflet modification to prevent LVOT obstruction during ViV TMVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/prevención & control
16.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378620

RESUMEN

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Arritmias Cardíacas , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
17.
J Thromb Thrombolysis ; 55(3): 426-431, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36653575

RESUMEN

Vaccination against COVID-19 reduces infection-related mortality. Unfortunately, reports of vaccine-induced immune thrombotic thrombocytopenia (VITT) in individuals administered adenovirus-vector-based vaccines (ChAdOx1 nCoV-19 and Ad26.COV2.S) have spurred side effect concerns. To address vaccine hesitancy related to this, it is essential to determine the incidence of VITT (defined by a 50% decrease in platelet count and positive anti-PF4 immunoassay within 4-28 days after vaccination) among patients administered two doses of an mRNA-based COVID-19 vaccination. We identified a retrospective cohort of 223,345 patients in the Cleveland Clinic Enterprise administered a COVID-19 vaccine at any location in Northeast Ohio and Florida from 12/4/2020 to 6/6/2021. 97.3% of these patients received an mRNA-based vaccination. Patients with: (1) a serial complete blood count both before and after vaccination and (2) a decrease in platelet count of ≥ 50% were selected for chart review. The primary outcome was the incidence of thrombotic events, including venous thromboembolism (VTE) and arterial thrombosis, 4-28 days post vaccination. Of 74 cohort patients with acute thrombosis, 72 (97.3%) demonstrated clear etiologies, such as active malignancy. Of two patients with unprovoked thrombosis, only one had findings concerning for VITT, with a strongly positive anti-PF4 antibody assay. In this large, multi-state, retrospective cohort, of 223,345 patients (97.2% of whom received the mRNA-based mRNA-1273 or BNT162b2 vaccines), we detected a single case that was concerning for VITT in a patient who received an mRNA vaccine. The overwhelming majority of patients with a thrombotic event 4-28 days following vaccination demonstrated clear etiologies.


Asunto(s)
COVID-19 , Púrpura Trombocitopénica Idiopática , Trombocitopenia , Humanos , Vacunas contra la COVID-19/efectos adversos , Ad26COVS1 , Vacuna BNT162 , ChAdOx1 nCoV-19 , Estudios Retrospectivos , COVID-19/prevención & control , Vacunación/efectos adversos , Trombocitopenia/inducido químicamente
18.
Echocardiography ; 40(4): 318-326, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36859633

RESUMEN

BACKGROUND: The implications of left ventricular remodeling and dysfunction before and after aortic valve replacement (AVR) for mixed aortic valve disease (MAVD) are not well understood. This study aims to evaluate the impact of AVR on left ventricular (LV) systolic function in MAVD, and determine the prognostic value of postoperative LV global longitudinal strain (LV-GLS) and LV ejection fraction (LVEF). METHODS: We retrospectively assessed 489 consecutive patients with MAVD (defined as at least moderate aortic stenosis and at least moderate aortic regurgitation) and baseline LVEF ≥50%, who underwent AVR between February 2003 and August 2018. All patients had baseline echocardiography, whereas 192 patients underwent postoperative echocardiography between 3 and 18 months after AVR. The primary endpoint was all-cause mortality. RESULTS: Mean age was 65 ± 15 years, and 65% were male. AVR in MAVD patients has a neutral effect on LV systolic function quantitated by LVEF and LV-GLS. During a median follow-up period of 5.8 years, 65 patients (34%) of 192 patients with follow-up echocardiography died. The patients with postoperative LVEF ≥50% had better survival than those with postoperative LVEF <50% (P < .001). Furthermore, among patients with postoperative LVEF ≥50%, mortality differed between patients with postoperative LV-GLS worse than -15% and those with postoperative LV-GLS better than -15% (P < .001). CONCLUSIONS: In patients with MAVD who underwent AVR, the mean postoperative LV-GLS and LVEF remain at a similar value to baseline. However, worse postoperative LV-GLS and LVEF were both independently associated with higher mortality in this population.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Disfunción Ventricular Izquierda , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Volumen Sistólico
19.
Curr Cardiol Rep ; 25(8): 807-816, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493873

RESUMEN

PURPOSE OF REVIEW: The dicrotic notch (DN) has long been considered a marker of arterial stiffness and compliance. Herein, we explored the recent developments in vascular medicine research in an attempt to assess the DN utility in clinical cardiovascular medicine. RECENT FINDINGS: Since its discovery, several studies have attempted to measure the changes in different parameters of the DN in physiological and pathological states. Despite the significance of their findings, the clinical role of the DN remained limited. This may have been related to the difficulty of measuring the DN via indwelling arterial catheters in the past. However, over the past two decades, several non-invasive methods have been developed, which may re-ignite interest in DN research. The DN may have broader applications in clinical cardiovascular medicine. Further research is needed to establish the accuracy of DN non-invasive measurement methods and compare its prognostic value to other circulatory parameters.

20.
Eur Heart J ; 43(29): 2729-2750, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35466382

RESUMEN

Transcatheter aortic valve implantation (TAVI) has matured into a standard treatment option for patients with severe symptomatic aortic valve stenosis (AS) across the whole spectrum of risk. The advances in the interventional treatment of AS raise the question of which patients with severe AS should be referred to surgery. The myriad of clinical permutations does not allow providing a single, uniform treatment strategy. Rather, the advent of TAVI along with established surgical aortic valve replacement (SAVR) fundamentally enforces the role of the multidisciplinary heart team for decision-making recommending the best individual choice of the two options based on a thorough review of clinical and anatomical factors as well as lifetime management considerations. Involvement of the informed patient expressing treatment preferences is a key for a shared decision-making process. Herein, we provide an in-depth review of evidence informing the decision-making process between TAVI and SAVR and key elements for treatment selection. Special attention is given to the populations that have been excluded from randomized clinical trials, and also lifetime management strategies of patients with severe AS are proposed.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA