Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Annu Rev Med ; 73: 355-362, 2022 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-34788544

RESUMEN

Atrial fibrillation (AF) is one of the most common cardiac arrhythmias. Implantable and wearable cardiac devices have enabled the detection of asymptomatic AF episodes-termed subclinical AF (SCAF). SCAF, the prevalence of which is likely significantly underestimated, is associated with increased cardiovascular and all-cause mortality and a significant stroke risk. Recent advances in machine learning, namely artificial intelligence-enabled ECG (AI-ECG), have enabled identification of patients at higher likelihood of SCAF. Leveraging the capabilities of AI-ECG algorithms to drive screening protocols could eventually allow for earlier detection and treatment and help reduce the burden associated with AF.


Asunto(s)
Fibrilación Atrial , Dispositivos Electrónicos Vestibles , Inteligencia Artificial , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Electrocardiografía , Humanos
2.
J Electrocardiol ; 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38997873

RESUMEN

Significant strides will be made in the field of computerized electrocardiology through the development of artificial intelligence (AI)-enhanced ECG (AI-ECG) algorithms. Yet, the scientific discourse has primarily relied upon on retrospective analyses for deriving and externally validating AI-ECG classification algorithms, an approach that fails to fully judge their real-world effectiveness or reveal potential unintended consequences. Prospective trials and analyses of AI-ECG algorithms will be crucial for assessing real-world diagnostic scenarios and understanding their practical utility and degree influence they confer onto clinicians. However, conducting such studies is challenging due to their resource-intensive nature and associated technical and logistical hurdles. To overcome these challenges, we propose an innovative approach to assess AI-ECG algorithms using a virtual testing environment. This strategy can yield critical insights into the practical utility and clinical implications of novel AI-ECG algorithms. Moreover, such an approach can enable an assessment of the influence of AI-ECG algorithms have their users. Herein, we outline a proposed randomized control trial for evaluating the diagnostic efficacy of new AI-ECG algorithm(s) specifically designed to differentiate between wide complex tachycardias into ventricular tachycardia and supraventricular wide complex tachycardia.

3.
Ann Noninvasive Electrocardiol ; 28(6): e13085, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37670480

RESUMEN

The discrimination of ventricular tachycardia (VT) versus supraventricular wide complex tachycardia (SWCT) via 12-lead electrocardiogram (ECG) is crucial for achieving appropriate, high-quality, and cost-effective care in patients presenting with wide QRS complex tachycardia (WCT). Decades of rigorous research have brought forth an expanding arsenal of applicable manual algorithm methods for differentiating WCTs. However, these algorithms are limited by their heavy reliance on the ECG interpreter for their proper execution. Herein, we introduce the Mayo Clinic ventricular tachycardia calculator (MC-VTcalc) as a novel generalizable, accurate, and easy-to-use means to estimate VT probability independent of ECG interpreter competency. The MC-VTcalc, through the use of web-based and mobile device platforms, only requires the entry of computerized measurements (i.e., QRS duration, QRS axis, and T-wave axis) that are routinely displayed on standard 12-lead ECG recordings.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Electrocardiografía/métodos , Diagnóstico Diferencial , Taquicardia Ventricular/diagnóstico , Taquicardia Supraventricular/diagnóstico , Algoritmos
4.
Ann Noninvasive Electrocardiol ; 28(1): e13018, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36409204

RESUMEN

BACKGROUND: Accurate automated wide QRS complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) can be accomplished using calculations derived from computerized electrocardiogram (ECG) data of paired WCT and baseline ECGs. OBJECTIVE: Develop and trial novel WCT differentiation approaches for patients with and without a corresponding baseline ECG. METHODS: We developed and trialed WCT differentiation models comprised of novel and previously described parameters derived from WCT and baseline ECG data. In Part 1, a derivation cohort was used to evaluate five different classification models: logistic regression (LR), artificial neural network (ANN), Random Forests [RF], support vector machine (SVM), and ensemble learning (EL). In Part 2, a separate validation cohort was used to prospectively evaluate the performance of two LR models using parameters generated from the WCT ECG alone (Solo Model) and paired WCT and baseline ECGs (Paired Model). RESULTS: Of the 421 patients of the derivation cohort (Part 1), a favorable area under the receiver operating characteristic curve (AUC) by all modeling subtypes: LR (0.96), ANN (0.96), RF (0.96), SVM (0.96), and EL (0.97). Of the 235 patients of the validation cohort (Part 2), the Solo Model and Paired Model achieved a favorable AUC for 103 patients with (Solo Model 0.87; Paired Model 0.95) and 132 patients without (Solo Model 0.84; Paired Model 0.95) a corroborating electrophysiology procedure or intracardiac device recording. CONCLUSION: Accurate WCT differentiation may be accomplished using computerized data of (i) the WCT ECG alone and (ii) paired WCT and baseline ECGs.


Asunto(s)
Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Electrocardiografía/métodos , Diagnóstico Diferencial , Taquicardia Ventricular/diagnóstico
5.
J Electrocardiol ; 79: 75-80, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36989954

RESUMEN

BACKGROUND: Artificial intelligence-augmented ECG (AI-ECG) refers to the application of novel AI solutions for complex ECG interpretation tasks. A broad variety of AI-ECG approaches exist, each having differing advantages and limitations relating to their creation and application. PURPOSE: To provide illustrative comparison of two general AI-ECG modeling approaches: machine learning (ML) and deep learning (DL). METHOD COMPARISON: Two AI-ECG algorithms were developed to carry out two separate tasks using ML and DL, respectively. ML modeling techniques were used to create algorithms designed for automatic wide QRS complex tachycardia differentiation into ventricular tachycardia and supraventricular tachycardia. A DL algorithm was formulated for the task of comprehensive 12­lead ECG interpretation. First, we describe the ML models for WCT differentiation, which rely upon expert domain knowledge to identify and formulate ECG features (e.g., percent monophasic time-voltage area [PMonoTVA]) that enable strong diagnostic performance. Second, we describe the DL method for comprehensive 12­lead ECG interpretation, which relies upon the independent recognition and analysis of a virtually incalculable number of ECG features from a vast collection of standard 12­lead ECGs. CONCLUSION: We have showcased two different AI-ECG methods, namely ML and DL respectively. In doing so, we highlighted the strengths and weaknesses of each approach. It is essential for investigators to understand these differences when attempting to create and apply novel AI-ECG solutions.


Asunto(s)
Inteligencia Artificial , Aprendizaje Profundo , Humanos , Electrocardiografía/métodos , Aprendizaje Automático , Algoritmos , Arritmias Cardíacas/diagnóstico
6.
J Electrocardiol ; 81: 44-50, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37517201

RESUMEN

Accurate differentiation of wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular wide complex tachycardia (SWCT) using non-invasive methods such as 12­lead electrocardiogram (ECG) interpretation is crucial in clinical practice. Recent studies have demonstrated the potential for automated approaches utilizing computerized ECG interpretation software to achieve accurate WCT differentiation. In this review, we provide a comprehensive analysis of contemporary automated methods for VT and SWCT differentiation. Our objectives include: (i) presenting a general overview of the emergence of automated WCT differentiation methods, (ii) examining the role of machine learning techniques in automated WCT differentiation, (iii) reviewing the electrophysiology concepts leveraged existing automated algorithms, (iv) discussing recently developed automated WCT differentiation solutions, and (v) considering future directions that will enable the successful integration of automated methods into computerized ECG interpretation platforms.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Electrocardiografía/métodos , Diagnóstico Diferencial , Taquicardia Ventricular/diagnóstico , Taquicardia Supraventricular/diagnóstico , Algoritmos
7.
J Electrocardiol ; 80: 166-173, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37467573

RESUMEN

BACKGROUND: Electrocardiogram (ECG) interpretation training is a fundamental component of medical education across disciplines. However, the skill of interpreting ECGs is not universal among medical graduates, and numerous barriers and challenges exist in medical training and clinical practice. An evidence-based and widely accessible learning solution is needed. DESIGN: The EDUcation Curriculum Assessment for Teaching Electrocardiography (EDUCATE) Trial is a prospective, international, investigator-initiated, open-label, randomized controlled trial designed to determine the efficacy of self-directed and active-learning approaches of a web-based educational platform for improving ECG interpretation proficiency. Target enrollment is 1000 medical professionals from a variety of medical disciplines and training levels. Participants will complete a pre-intervention baseline survey and an ECG interpretation proficiency test. After completion, participants will be randomized into one of four groups in a 1:1:1:1 fashion: (i) an online, question-based learning resource, (ii) an online, lecture-based learning resource, (iii) an online, hybrid question- and lecture-based learning resource, or (iv) a control group with no ECG learning resources. The primary endpoint will be the change in overall ECG interpretation performance according to pre- and post-intervention tests, and it will be measured within and compared between medical professional groups. Secondary endpoints will include changes in ECG interpretation time, self-reported confidence, and interpretation accuracy for specific ECG findings. CONCLUSIONS: The EDUCATE Trial is a pioneering initiative aiming to establish a practical, widely available, evidence-based solution to enhance ECG interpretation proficiency among medical professionals. Through its innovative study design, it tackles the currently unaddressed challenges of ECG interpretation education in the modern era. The trial seeks to pinpoint performance gaps across medical professions, compare the effectiveness of different web-based ECG content delivery methods, and create initial evidence for competency-based standards. If successful, the EDUCATE Trial will represent a significant stride towards data-driven solutions for improving ECG interpretation skills in the medical community.


Asunto(s)
Curriculum , Electrocardiografía , Humanos , Estudios Prospectivos , Electrocardiografía/métodos , Aprendizaje , Evaluación Educacional , Competencia Clínica , Enseñanza
8.
J Cardiovasc Electrophysiol ; 33(8): 1932-1943, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35258136

RESUMEN

BACKGROUND: In the context of atrial fibrillation (AF), traditional clinical practices have thus fallen short in several domains, such as identifying patients at risk of incident AF or patients with concomitant undetected paroxysmal AF. Novel approaches leveraging artificial intelligence have the potential to provide new tools to deal with some of these old problems. AIMS: To discuss the roles of artificial intelligence (AI)-enabled electrocardiogram (ECG) pertaining to AF, potential roles of deep learning (DL) models in the context of current knowledge gaps, as well as limitations of these models. MATERIALS & METHODS: An extensive search and review of the currently available literature on the topics. RESULTS: One key area where DL models can translate to better patient outcomes is through automated ECG interpretation. Challenges with regards to the benefits and harms of AF screening remain. In this context, a unique model was developed to detect underlying hidden AF from sinus rhythm. DISCUSSION: Knowledge gaps remain regarding the best ways to monitor patients with embolic stroke of undetermined source (ESUS) and identifying those who would benefit most from oral anticoagulation. The AI-enabled AF model is one potential way to tackle this complex problem as it could be used to identify a subset of high-risk ESUS patients likely to benefit from empirical oral anticoagulation. The role of DL models assessing AF burden from long-duration ECG data is also discussed as a way of guiding management. There is a trend towards the use of consumer-grade wristbands and watches to detect AF from photoplethysmography data. However, ECG currently remains the gold standard to detect arrythmias including AF. Lastly, the role of adequate external validation of the models and clinical trials to study true performance is discussed. CONCLUSION: Algorithms using AI to interpret ECGs in various new ways have been developed. While still, much work needs to be done, these technologies have shown enormous potential in a short span of time. With further advancements and continuous research, these novel ways of interpretation may well become part of everyday clinical workflow.


Asunto(s)
Fibrilación Atrial , Algoritmos , Anticoagulantes , Inteligencia Artificial , Electrocardiografía , Humanos
9.
Ann Noninvasive Electrocardiol ; 27(1): e12890, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34562325

RESUMEN

BACKGROUND: Automated wide complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) may be accomplished using novel calculations that quantify the extent of mean electrical vector changes between the WCT and baseline electrocardiogram (ECG). At present, it is unknown whether quantifying mean electrical vector changes within three orthogonal vectorcardiogram (VCG) leads (X, Y, and Z leads) can improve automated VT and SWCT classification. METHODS: A derivation cohort of paired WCT and baseline ECGs was used to derive five logistic regression models: (i) one novel WCT differentiation model (i.e., VCG Model), (ii) three previously developed WCT differentiation models (i.e., WCT Formula, VT Prediction Model, and WCT Formula II), and (iii) one "all-inclusive" model (i.e., Hybrid Model). A separate validation cohort of paired WCT and baseline ECGs was used to trial and compare each model's performance. RESULTS: The VCG Model, composed of WCT QRS duration, baseline QRS duration, absolute change in QRS duration, X-lead QRS amplitude change, Y-lead QRS amplitude change, and Z-lead QRS amplitude change, demonstrated effective WCT differentiation (area under the curve [AUC] 0.94) for the derivation cohort. For the validation cohort, the diagnostic performance of the VCG Model (AUC 0.94) was similar to that achieved by the WCT Formula (AUC 0.95), VT Prediction Model (AUC 0.91), WCT Formula II (AUC 0.94), and Hybrid Model (AUC 0.95). CONCLUSION: Custom calculations derived from mathematically synthesized VCG signals may be used to formulate an effective means to differentiate WCTs automatically.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Diagnóstico Diferencial , Electrocardiografía , Humanos , Modelos Logísticos , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
10.
J Electrocardiol ; 70: 37-38, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34871963

RESUMEN

The prevalence of atrial fibrillation (AF) continues to grow in an aging population, and its impact on both patients and the health care system has has made it a global burden. There are limited available options to detect individuals at risk of AF that may benefit from prevention and treatment strategies. The ECG may be an effective tool do so. In this work, we discuss the latest work by Hayiroglu and colleagues related to this work and the use of novel ECG prediction tools to identify individuals individuals that could benefit from early and proactive screening, surveillance, and management strategies.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Anciano , Electrocardiografía , Humanos , Tamizaje Masivo , Prevalencia , Accidente Cerebrovascular/diagnóstico
11.
J Electrocardiol ; 74: 32-39, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35933848

RESUMEN

BACKGROUND: Timely and accurate discrimination of wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular WCT (SWCT) is critically important. Previously we developed and validated an automated VT Prediction Model that provides a VT probability estimate using the paired WCT and baseline 12-lead ECGs. Whether this model improves physicians' diagnostic accuracy has not been evaluated. OBJECTIVE: We sought to determine whether the VT Prediction Model improves physicians' WCT differentiation accuracy. METHODS: Over four consecutive days, nine physicians independently interpreted fifty WCT ECGs (25 VTs and 25 SWCTs confirmed by electrophysiological study) as either VT or SWCT. Day 1 used the WCT ECG only, Day 2 used the WCT and baseline ECG, Day 3 used the WCT ECG and the VT Prediction Model's estimation of VT probability, and Day 4 used the WCT ECG, baseline ECG, and the VT Prediction Model's estimation of VT probability. RESULTS: Inclusion of the VT Prediction Model data increased diagnostic accuracy versus the WCT ECG alone (Day 3: 84.2% vs. Day 1: 68.7%, p 0.009) and WCT and baseline ECGs together (Day 3: 84.2% vs. Day 2: 76.4%, p 0.003). There was no further improvement of accuracy with addition of the baseline ECG comparison to the VT Prediction Model (Day 3: 84.2% vs. Day 4: 84.0%, p 0.928). Overall sensitivity (Day 3: 78.2% vs. Day 1: 67.6%, p 0.005) and specificity (Day 3: 90.2% vs. Day 1: 69.8%, p 0.016) for VT were superior after the addition of the VT Prediction Model. CONCLUSION: The VT Prediction Model improves physician ECG diagnostic accuracy for discriminating WCTs.


Asunto(s)
Electrocardiografía , Médicos , Humanos
12.
J Electrocardiol ; 65: 50-54, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33503517

RESUMEN

Accurate wide QRS complex tachycardia (WCT) differentiation into either ventricular tachycardia or supraventricular wide complex tachycardia using 12­lead electrocardiogram (ECG) interpretation is essential for diagnostic, therapeutic, and prognostic reasons. There is an ever-expanding variety of WCT differentiation methods and criteria available to clinicians. However, only a few make use of the diagnostic value of comparing the ECG during WCT to that of the patient's baseline ECG. Therefore, we highlight the conceptual rationale and scientific literature supporting the diagnostic value of WCT and baseline ECG comparison.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Diagnóstico Diferencial , Electrocardiografía , Humanos , Pronóstico , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
13.
J Stroke Cerebrovasc Dis ; 30(9): 105998, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34303963

RESUMEN

OBJECTIVES: Embolic strokes of unknown source (ESUS) are common and often suspected to be caused by unrecognized paroxysmal atrial fibrillation (AF). An AI-enabled ECG (AI-ECG) during sinus rhythm has been shown to identify patients with unrecognized AF. We pursued this study to determine if the AI-ECG model differentiates between patients with ESUS and those with known causes of stroke, and to evaluate whether the AF prediction by AI-ECG among patients with ESUS was associated with the results of prolonged ambulatory cardiac rhythm monitoring. MATERIALS AND METHODS: We reviewed consecutive patients admitted with acute ischemic stroke to a comprehensive stroke center between January 2018 and August 2019 and employed the TOAST classification to categorize the mechanisms of ischemia. Use and results of ambulatory cardiac rhythm monitoring after discharge were gathered. We ran the AI-ECG model to obtain AF probabilities from all ECGs acquired during the hospitalization and compared those probabilities in patients with ESUS versus those with known stroke causes (apart from AF), and between patients with and without AF detected by ambulatory cardiac rhythm monitoring. RESULTS: The study cohort had 930 patients, including 263 patients (28.3%) with known AF or AF diagnosed during the index hospitalization and 265 cases (28.5%) categorized as ESUS. Ambulatory cardiac rhythm monitoring was performed in 226 (85.3%) patients with ESUS. AF probability by AI-ECG was not associated with ESUS. However, among patients with ESUS, the probability of AF by AI-ECG was associated with a higher likelihood of AF detection by ambulatory monitoring (P = 0.004). A probability of AF by AI-ECG greater than 0.20 was associated with AF detection by ambulatory cardiac rhythm monitoring with an OR of 5.47 (95% CI 1.51-22.51). CONCLUSIONS: AI-ECG may help guide the use of prolonged ambulatory cardiac rhythm monitoring in patients with ESUS to identify those who might benefit from anticoagulation.


Asunto(s)
Inteligencia Artificial , Fibrilación Atrial/diagnóstico , Electrocardiografía Ambulatoria , Accidente Cerebrovascular Embólico/etiología , Procesamiento de Señales Asistido por Computador , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Accidente Cerebrovascular Embólico/diagnóstico por imagen , Femenino , Frecuencia Cardíaca , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
14.
J Cardiovasc Electrophysiol ; 31(1): 185-195, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31840870

RESUMEN

BACKGROUND: The accurate separation of undifferentiated wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular wide complex tachycardia (SWCT) using conventional, manually-applied 12-lead electrocardiogram (ECG) interpretation methods is difficult. PURPOSE: We sought to devise a new WCT differentiation method that operates solely on automated measurements routinely provided by computerized ECG interpretation software. METHODS: In a two-part analysis, we developed and validated a logistic regression model (ie, VT Prediction Model) that utilizes routinely available computerized measurements derived from patients' paired WCT and baseline ECGs. RESULTS: The derivation cohort consisted of 601 paired WCT (273 VT, 328 SWCT) and baseline ECGs from 421 patients. The VT Prediction Model, composed of WCT QRS duration (ms) (P < .0001), QRS duration change (ms) (P < .0001), QRS axis change (°) (P < .0001) and T axis change (°) (P < .0001), yielded effective VT and SWCT differentiation (area under the curve [AUC]: 0.924; confidence interval [CI]: 0.903-0.944) for the derivation cohort. The validation cohort comprised 241 paired WCT (97 VT, 144 SWCT) and baseline ECGs from 177 patients. The VT Prediction Model's implementation on the validation cohort yielded effective WCT differentiation (AUC: 0.900; CI: 0.862-0.939) with overall accuracy, sensitivity, and specificity of 85.0%, 80.4%, and 88.2%, respectively. CONCLUSION: The VT Prediction Model is an example of how readily available ECG measurements may be used to distinguish VT and SWCT effectively. Further study is needed to develop and refine newer WCT differentiation approaches that utilize computerized measurements provided by ECG interpretation software.


Asunto(s)
Potenciales de Acción , Técnicas de Apoyo para la Decisión , Electrocardiografía , Frecuencia Cardíaca , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Factores de Tiempo , Adulto Joven
15.
Curr Cardiol Rep ; 22(8): 57, 2020 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-32562154

RESUMEN

PURPOSE OF REVIEW: To (i) review the concept of artificial intelligence (AI); (ii) summarize recent developments in artificial intelligence-enabled electrocardiogram (AI-ECG); (iii) address notable inherent limitations and challenges of AI-ECG; and (iv) discuss the future direction of the field. RECENT FINDINGS: Advancements in machine learning and computing methods have led to application of AI-ECG and potential new applications to patient care. Further study is needed to verify previous findings in diverse populations as well as begin to confront the limitations needed for clinical implementation. Nearly one century after the Nobel Prize was awarded to Willem Einthoven for demonstrating that an electrocardiogram (ECG) could record the electrical signature of the heart, the ECG remains one of the most important diagnostic tests in modern medicine. We now stand at the edge of true ECG innovation. Simultaneous advancements in computing power, wireless technology, digitized data availability, and machine learning have led to the birth of AI-ECG algorithms with novel capabilities and real potential for clinical application. AI has the potential to improve diagnostic accuracy and efficiency by providing fully automated, unbiased, and unambiguous ECG analysis along with promising new findings that may unlock new value in the ECG. These breakthroughs may cause a paradigm shift in clinical workflow as well as patient monitoring and management.


Asunto(s)
Inteligencia Artificial , Aprendizaje Automático , Algoritmos , Electrocardiografía , Humanos , Tecnología
16.
J Electrocardiol ; 61: 77-80, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32554160

RESUMEN

Early recognition of ST-segment elevation myocardial infarction equivalent electrocardiogram patterns is of paramount importance. Successful identification of these ischemic patterns helps ensure proper triage of patients needing urgent restoration of coronary perfusion. The so-called de Winter sign has become increasingly recognized as a ST-segment elevation myocardial infarction equivalent pattern due to proximal left anterior descending artery occlusion. Yet, despite the de Winter pattern's well-defined electrocardiographic-angiographic relationship, the electrophysiologic explanation for its characteristic electrocardiographic manifestations remains unclear. Herein, we report a case in which an ischemic lateral lead variant of the de Winter pattern emerged from a patient inflicted by an abrupt thrombotic occlusion of the ostial left anterior descending artery, which developed in series with a high-grade stenosis of the distal left main coronary artery. We examine the patient's presenting electrocardiographic findings and clinical course to (i) establish causal inferences that align with the distribution of myocardial ischemia supported by coronary angiography and (ii) provide an accompanying analysis of the relevant scientific literature.


Asunto(s)
Vasos Coronarios , Infarto del Miocardio con Elevación del ST , Constricción Patológica , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía , Humanos
17.
J Electrocardiol ; 60: 203-208, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32417627

RESUMEN

Despite many technological advances in the field of cardiology, accurate differentiation of wide complex tachycardias into ventricular tachycardia or supraventricular wide complex tachycardia continues to be challenging. After decades of rigorous clinical research, a wide variety of electrocardiographic criteria and algorithms have been developed to provide an accurate means to distinguish these two entities as accurately as possible. Recently, promising automated differentiation methods that utilize computerized electrocardiographic interpretation software have emerged. In this review, we aim to (1) highlight the clinical importance of accurate wide complex tachycardia differentiation, (2) provide an overview of the conventional manually-applied differentiation algorithms, and (3) describe novel automated approaches to differentiate wide complex tachycardia.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Algoritmos , Diagnóstico Diferencial , Electrocardiografía , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
18.
J Electrocardiol ; 61: 121-129, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32599290

RESUMEN

BACKGROUND: Differentiation of wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular wide complex tachycardia (SWCT) using conventional manually-operated electrocardiogram (ECG) interpretation methods is difficult. Recent research has shown that accurate WCT differentiation may be accomplished by automated approaches (e.g., WCT Formula) implemented by computerized ECG interpretation software. OBJECTIVE: We sought to develop a new automated means to differentiate WCTs. METHODS: First, a derivation cohort of paired WCT and baseline ECGs was examined to secure independent VT predictors to be incorporated into a logistic regression model (i.e., WCT Formula II). Second, the WCT Formula II was trialed against a separate validation cohort of paired WCT and baseline ECGs. RESULTS: The derivation cohort comprised 317 paired WCT (157 VT, 160 SWCT) and baseline ECGs. The WCT Formula II was composed of baseline QRS duration (p = 0.02), WCT QRS duration (p < 0.001), frontal percent time-voltage area change (p < 0.001), and horizontal percent time-voltage area change (p < 0.001). The area under the curve (AUC) for VT and SWCT differentiation was 0.96 (95% CI 0.94-0.98) for the derivation cohort. The validation cohort consisted of 284 paired WCT (116 VT, 168 SWCT) and baseline ECGs. WCT Formula II implementation on the validation cohort yielded effective WCT differentiation (AUC 0.96; 95% CI 0.94-0.98). CONCLUSION: The WCT Formula II is an example of how contemporary ECG interpretation software could be used to differentiate WCTs successfully.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Diagnóstico Diferencial , Electrocardiografía , Humanos , Programas Informáticos , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
19.
JAMA ; 324(9): 871-878, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32870297

RESUMEN

Importance: Outcomes of postoperative atrial fibrillation (AF) after noncardiac surgery are not well defined. Objective: To determine the association of new-onset postoperative AF vs no AF after noncardiac surgery with risk of nonfatal and fatal outcomes. Design, Setting, and Participants: Retrospective cohort study in Olmsted County, Minnesota, involving 550 patients who had their first-ever documented AF within 30 days after undergoing a noncardiac surgery (postoperative AF) between 2000 and 2013. Of these patients, 452 were matched 1:1 on age, sex, year of surgery, and type of surgery to patients with noncardiac surgery who were not diagnosed with AF within 30 days following the surgery (no AF). The last date of follow-up was December 31, 2018. Exposures: Postoperative AF vs no AF after noncardiac surgery. Main Outcomes and Measures: The primary outcome was ischemic stroke or transient ischemic attack (TIA). Secondary outcomes included subsequent documented AF, all-cause mortality, and cardiovascular mortality. Results: The median age of the 452 matched patients was 75 years (IQR, 67-82 years) and 51.8% of patients were men. Patients with postoperative AF had significantly higher CHA2DS2-VASc scores than those in the no AF group (median, 4 [IQR, 2-5] vs 3 [IQR, 2-5]; P < .001). Over a median follow-up of 5.4 years (IQR, 1.4-9.2 years), there were 71 ischemic strokes or TIAs, 266 subsequent documented AF episodes, and 571 deaths, of which 172 were cardiovascular related. Patients with postoperative AF exhibited a statistically significantly higher risk of ischemic stroke or TIA (incidence rate, 18.9 vs 10.0 per 1000 person-years; absolute risk difference [RD] at 5 years, 4.7%; 95% CI, 1.0%-8.4%; HR, 2.69; 95% CI, 1.35-5.37) compared with those with no AF. Patients with postoperative AF had statistically significantly higher risks of subsequent documented AF (incidence rate 136.4 vs 21.6 per 1000 person-years; absolute RD at 5 years, 39.3%; 95% CI, 33.6%-45.0%; HR, 7.94; 95% CI, 4.85-12.98), and all-cause death (incidence rate, 133.2 vs 86.8 per 1000 person-years; absolute RD at 5 years, 9.4%; 95% CI, 4.9%-13.7%; HR, 1.66; 95% CI, 1.32-2.09). No significant difference in the risk of cardiovascular death was observed for patients with and without postoperative AF (incidence rate, 42.5 vs 25.0 per 1000 person-years; absolute RD at 5 years, 6.2%; 95% CI, 2.2%-10.4%; HR, 1.51; 95% CI, 0.97-2.34). Conclusions and Relevance: Among patients undergoing noncardiac surgery, new-onset postoperative AF compared with no AF was associated with a significant increased risk of stroke or TIA. However, the implications of these findings for the management of postoperative AF, such as the need for anticoagulation therapy, require investigation in randomized trials.


Asunto(s)
Fibrilación Atrial/complicaciones , Ataque Isquémico Transitorio/etiología , Complicaciones Posoperatorias/etiología , Accidente Cerebrovascular/etiología , Procedimientos Quirúrgicos Operativos , Anciano , Anciano de 80 o más Años , Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Ataque Isquémico Transitorio/epidemiología , Masculino , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Riesgo , Factores de Riesgo , Accidente Cerebrovascular/epidemiología
20.
J Electrocardiol ; 55: 28-31, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31078104

RESUMEN

The standard 12­lead electrocardiogram (ECG) has become a mainstay diagnostic tool in patients suspected to have myocardial ischemia. The identification of hallmark electrocardiographic abnormalities, such as ST-segment deviation or serial T wave changes, not only helps identify the presence of myocardial ischemia but also may help localize myocardial territories with an ongoing injury. Widespread ST-segment depression is commonly attributed to diffuse subendocardial ischemia precipitated by severe multivessel or left main coronary artery disease. However, among patients with prior coronary revascularization, clear electrocardiographic-angiographic relationships responsible for widespread ST-segment depressions have not been well defined. We report a case in which diffuse ST-segment depression emerged from a patient with prior coronary artery bypass grafting. In this report, we examine the patient's presenting ECG pattern as to (1) establish causal inferences which align with the distribution of myocardial ischemia supported by angiography and (2) provide an accompanying analysis of the relevant scientific literature.


Asunto(s)
Depresión , Isquemia Miocárdica , Angiografía , Angiografía Coronaria , Puente de Arteria Coronaria , Electrocardiografía , Humanos , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/cirugía
SELECCIÓN DE REFERENCIAS