1.
Neuroradiology ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880824

RESUMEN

BACKGROUND AND PURPOSE: Quantitative T1 mapping can be an essential tool for assessing tissue injury in multiple sclerosis (MS). We introduce T1-REQUIRE, a method that converts a single high-resolution anatomical 3D T1-weighted Turbo Field Echo (3DT1TFE) scan into a parametric T1 map that could be used for quantitative assessment of tissue damage. We present the accuracy and feasibility of this method in MS. METHODS: 14 subjects with relapsing-remitting MS and 10 healthy subjects were examined. T1 maps were generated from 3DT1TFE images using T1-REQUIRE, which estimates T1 values using MR signal equations and internal tissue reference T1 values. Estimated T1 of lesions, white, and gray matter regions were compared with reference Inversion-Recovery Fast Field Echo T1 values and analyzed via correlation and Bland-Altman (BA) statistics. RESULTS: 159 T1-weighted (T1W) hypointense MS lesions and 288 gray matter regions were examined. T1 values for MS lesions showed a Pearson's correlation of r = 0.81 (p < 0.000), R2 = 0.65, and Bias = 4.18%. BA statistics showed a mean difference of -53.95 ms and limits of agreement (LOA) of -344.20 and 236.30 ms. Non-lesional normal-appearing white matter had a correlation coefficient of r = 0.82 (p < 0.000), R2 = 0.67, Bias = 8.78%, mean difference of 73.87 ms, and LOA of -55.67 and 203.41 ms. CONCLUSIONS: We demonstrate the feasibility of retroactively derived high-resolution T1 maps from routinely acquired anatomical images, which could be used to quantify tissue pathology in MS. The results of this study will set the stage for testing this method in larger clinical studies for examining MS disease activity and progression.

2.
J Cardiovasc Magn Reson ; 24(1): 27, 2022 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-35410226

RESUMEN

BACKGROUND: Theoretically, artificial intelligence can provide an accurate automatic solution to measure right ventricular (RV) ejection fraction (RVEF) from cardiovascular magnetic resonance (CMR) images, despite the complex RV geometry. However, in our recent study, commercially available deep learning (DL) algorithms for RVEF quantification performed poorly in some patients. The current study was designed to test the hypothesis that quantification of RV function could be improved in these patients by using more diverse CMR datasets in addition to domain-specific quantitative performance evaluation metrics during the cross-validation phase of DL algorithm development. METHODS: We identified 100 patients from our prior study who had the largest differences between manually measured and automated RVEF values. Automated RVEF measurements were performed using the original version of the algorithm (DL1), an updated version (DL2) developed from a dataset that included a wider range of RV pathology and validated using multiple domain-specific quantitative performance evaluation metrics, and conventional methodology performed by a core laboratory (CORE). Each of the DL-RVEF approaches was compared against CORE-RVEF reference values using linear regression and Bland-Altman analyses. Additionally, RVEF values were classified into 3 categories: ≤ 35%, 35-50%, and ≥ 50%. Agreement between RVEF classifications made by the DL approaches and the CORE measurements was tested. RESULTS: CORE-RVEF and DL-RVEFs were obtained in all patients (feasibility of 100%). DL2-RVEF correlated with CORE-RVEF better than DL1-RVEF (r = 0.87 vs. r = 0.42), with narrower limits of agreement. As a result, DL2 algorithm also showed increasing accuracy from 0.53 to 0.80 for categorizing RV function. CONCLUSIONS: The use of a new DL algorithm cross-validated on a dataset with a wide range of RV pathology using multiple domain-specific metrics resulted in a considerable improvement in the accuracy of automated RVEF measurements. This improvement was demonstrated in patients whose images were the most challenging and resulted in the largest RVEF errors. These findings underscore the critical importance of this strategy in the development of DL approaches for automated CMR measurements.


Asunto(s)
Inteligencia Artificial , Disfunción Ventricular Derecha , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Volumen Sistólico , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
3.
J Magn Reson Imaging ; 54(4): 1257-1265, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33742522

RESUMEN

BACKGROUND: Late gadolinium enhancement (LGE) imaging in patients with implantable cardioverter-defibrillators (ICD) is limited by device-related artifacts (DRA). The use of wideband (WB) LGE protocols improves LGE images, but their efficacy with different ICD types is not well known. PURPOSE: To assess the effects of WB LGE imaging on DRA in different non-MR conditional ICD subtypes. STUDY TYPE: Retrospective. POPULATION: A total of 113 patients undergoing cardiac magnetic resonance imaging with three ICD subtypes: transvenous (TV-ICD, N = 48), cardiac-resynchronization therapy device (CRT-D, N = 48), and subcutaneous (S-ICD, N = 17). FIELD STRENGTH/SEQUENCE: 5 T scanner, standard LGE, and WB LGE imaging with a phase-sensitive inversion recovery segmented gradient echo sequence. ASSESSMENT: DRA burden was defined as the number of artifact-positive short-axis LGE slices as percentage of the total number of short-axis slices covering the left ventricle from based to apex, and was determined for WB and standard LGE studies for each patient. Additionally, artifact area on each slice was quantified. STATISTICAL TESTS: Shapiro-Wilks, Kruskal-Wallis analysis of variance, Dunn tests with Bonferroni correction, and Mann-Whitney U-test. RESULTS: In patients with TV-ICD, DRA burden was significantly reduced and nearly eliminated with WB LGE compared to standard LGE imaging (median [interquartile range]: 0 [0-7]% vs. 18 [0-50]%, P < 0.05), but WB imaging had less of an impact on DRA in the CRT-D (8 [0-23]% vs. 16 [0-45]%, p = 0.12) and S-ICD (60 [15-71]% vs. 67 [50-92]%, P = 0.09) patients. Residual DRA was significantly greater (P < 0.05) for S-ICD compared to other device types with WB LGE imaging, despite the generators of all three ICD types having similar proximity to the heart. The area of S-ICD associated DRA was smaller with WB LGE (P < 0.001) than with standard LGE imaging and the artifacts had different characteristics (dark signal void instead of a bright hyperenhancement artifact). DATA CONCLUSION: Although WB LGE imaging reduced the burden of DRA caused by S-ICD, the residual artifact was greater than that observed with TV-ICD and CRT-D devices. Further developments are needed to better resolve S-ICD artifacts. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: STAGE: 5.


Asunto(s)
Desfibriladores Implantables , Gadolinio , Artefactos , Medios de Contraste , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos
4.
J Cardiovasc Magn Reson ; 22(1): 51, 2020 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-32698811

RESUMEN

BACKGROUND: Right ventricular (RV) strain is a useful predictor of prognosis in various cardiovascular diseases, including those traditionally believed to impact only the left ventricle. We aimed to determine inter-modality and inter-technique agreement in RV longitudinal strain (LS) measurements between currently available cardiovascular magnetic resonance (CMR) and echocardiographic techniques, as well as their reproducibility and the impact of layer-specific strain measurements. METHODS: RV-LS was determined in 62 patients using 2D speckle tracking echocardiography (STE, Epsilon) and two CMR techniques: feature tracking (FT) and strain-encoding (SENC), and in 17 healthy subjects using FT and SENC only. Measurements included global and free-wall LS (GLS, FWLS). Inter-technique agreement was assessed using linear regression and Bland-Altman analysis. Reproducibility was quantified using intraclass correlation (ICC) and coefficients of variation (CoV). RESULTS: We found similar moderate agreement between both CMR techniques and STE in patients: r = 0.57-0.63 for SENC; r = 0.50-0.62 for FT. The correlation between SENC and STE was better for GLS (r = 0.63) than for FWLS (r = 0.57). Conversely, the correlation between FT and STE was higher for FWLS (r = 0.60-0.62) than GLS (r = 0.50-0.54). FT-midmyocardial strain correlated better with SENC and STE than FT-subendocardial strain. The agreement between SENC and FT was fair (r = 0.36-0.41, bias: - 6.4 to - 10.4%) in the entire study group. All techniques except FT showed excellent reproducibility (ICC: 0.62-0.96, CoV: 0.04-0.30). CONCLUSIONS: We found only moderate inter-modality agreement with STE in RV-LS for both FT and SENC and poor agreement when comparing between the CMR techniques. Different modalities and techniques should not be used interchangeably to determine and monitor RV strain.


Asunto(s)
Ecocardiografía/métodos , Imagen por Resonancia Magnética/métodos , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/fisiopatología , Adulto , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
5.
Magn Reson Med ; 81(6): 3567-3577, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30737833

RESUMEN

PURPOSE: This work sought to compare a quantitative T1 bookend dynamic susceptibility contrast MRI based perfusion protocol for absolute cerebral blood flow (qCBF) against CBF measured by the stable-isotope neutron capture microsphere method, a recognized reference standard for measuring tissue blood flow, at normocapnia, hypercapnia, and in acute stroke. METHODS: CBF was measured in anesthetized female canines by MRI and microspheres over 2 consecutive days for each case. On day 1, 5 canines were measured before and during a physiological challenge induced by carbogen inhalation; on day 2, 4 canines were measured following permanent occlusion of the middle cerebral artery. CBF and cerebrovascular reactivity measured by MRI and microsphere deposition were compared. RESULTS: MRI correlated strongly with microspheres at the hemispheric level for CBF during normo- and hypercapnic states (r2 = 0.96), for individual cerebrovascular reactivity (r2 = 0.84), and for postocclusion CBF (r2 = 0.82). Correction for the delay and dispersion of the contrast bolus resulted in a significant improvement in the correlation between MRI and microsphere deposition in the ischemic state (r2 = 0.96). In all comparisons, moderate correlations were found at the regional level. CONCLUSION: In an experimental canine model with and without permanent occlusion of the middle cerebral artery, MRI-based qCBF yielded moderate to strong correlations for absolute quantitative CBF and cerebrovascular reactivity measurements during normocapnia and hypercapnia. Correction for delay and dispersion greatly improved the quantitation during occlusion of the middle cerebral artery, underscoring the importance for this correction under focal ischemic condition.


Asunto(s)
Circulación Cerebrovascular/fisiología , Medios de Contraste/química , Isótopos/química , Imagen por Resonancia Magnética , Imagen de Perfusión , Animales , Modelos Animales de Enfermedad , Perros , Femenino , Hipercapnia/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Microesferas , Arteria Cerebral Media/diagnóstico por imagen , Imagen de Perfusión/métodos , Imagen de Perfusión/normas , Accidente Cerebrovascular/diagnóstico por imagen
6.
Magn Reson Med ; 81(2): 1229-1236, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30284727

RESUMEN

PURPOSE: To determine the reproducibility of quantitative susceptibility mapping at multiple sites on clinical and preclinical scanners (1.5 T, 3 T, 7 T, and 9.4 T) from different vendors (Siemens, GE, Philips, and Bruker) for standardization of multicenter studies. METHODS: Seven phantoms distributed from the core site, each containing 5 compartments with gadolinium solutions with fixed concentrations between 0.625 mM and 10 mM. Multi-echo gradient echo scans were performed at 1.5 T, 3 T, 7 T, and 9.4 T on 12 clinical and 3 preclinical scanners. DICOM images from the scans were processed into quantitative susceptibility maps using the Laplacian boundary value (LBV) and MEDI+0 automatic uniform reference algorithm. Region of interest (ROI) analyses were performed by a physicist to determine agreement between results from all sites. Measurement reproducibility was assessed using regression, Bland-Altman plots, and the intra-class correlation coefficient (ICC). RESULTS: Quantitative susceptibility mapping (QSM) from all scanners had similar, artifact-free visual appearance. Regression analysis showed a linear relationship between gadolinium concentrations and average QSM measurements for all phantoms (y = 350x - 0.0346, r2 >0.99). The SD of measurements increased almost linearly from 32 ppb to 230 ppb as the measured susceptibility increased from 0.26 ppm to 3.56 ppm. A Bland-Altman plot showed the bias, upper, and lower limits of agreement for all comparisons were -10, -210, and 200 ppb, respectively. The ICC was 0.991 with a 95% CI (0.973, 0.99). CONCLUSIONS: QSM shows excellent multicenter reproducibility for a large range of susceptibility values encountered in cranial and extra-cranial applications on a diverse set of scanner platforms.


Asunto(s)
Gadolinio/química , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/normas , Algoritmos , Artefactos , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Hierro/análisis , Reconocimiento de Normas Patrones Automatizadas , Fantasmas de Imagen , Análisis de Regresión , Reproducibilidad de los Resultados , Relación Señal-Ruido
7.
J Cardiovasc Magn Reson ; 21(1): 46, 2019 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-31391036

RESUMEN

OBJECTIVES: We sought to: (1) determine the agreement in cardiovascular magnetic resonance (CMR) and speckle tracking echocardiography (STE) derived strain measurements, (2) compare their reproducibility, (3) determine which approach is best related to CMR late gadolinium enhancement (LGE). BACKGROUND: While STE-derived strain is routinely used to assess left ventricular (LV) function, CMR strain measurements are not yet standardized. Strain can be measured using dedicated pulse sequences (strain-encoding, SENC), or post-processing of cine images (feature tracking, FT). It is unclear whether these measurements are interchangeable, and whether strain can be used as an alternative to LGE. METHODS: Fifty patients underwent 2D echocardiography and 1.5 T CMR. Global longitudinal strain (GLS) was measured by STE (Epsilon), FT (NeoSoft) and SENC (Myocardial Solutions) and circumferential strain (GCS) by FT and SENC. RESULTS: GLS showed good inter-modality agreement (r-values: 0.71-0.75), small biases (< 1%) but considerable limits of agreement (- 7 to 8%). The agreement between the CMR techniques was better for GLS than GCS (r = 0.81 vs 0.67; smaller bias). Repeated measurements showed low intra- and inter-observer variability for both GLS and GCS (intraclass correlations 0.86-0.99; coefficients of variation 3-13%). LGE was present in 22 (44%) of patients. Both SENC- and FT-derived GLS and GCS were associated with LGE, while STE-GLS was not. Irrespective of CMR technique, this association was stronger for GCS (AUC 0.77-0.78) than GLS (AUC 0.67-0.72) and STE-GLS (AUC = 0.58). CONCLUSION: There is good inter-technique agreement in strain measurements, which were highly reproducible, irrespective of modality or analysis technique. GCS may better reflect the presence of underlying LGE than GLS.


Asunto(s)
Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Isquemia Miocárdica/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Isquemia Miocárdica/fisiopatología , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Volumen Sistólico , Disfunción Ventricular Izquierda/fisiopatología
8.
BMC Cardiovasc Disord ; 19(1): 52, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-30836942

RESUMEN

BACKGROUND: Recently introduced fast strain-encoded (SENC) cardiac magnetic resonance (CMR) imaging (fast-SENC) provides real-time acquisition of myocardial performance in a single heartbeat. We aimed to test the ability and accuracy of real-time strain-encoded CMR imaging to estimate left ventricular volumes, ejection fraction and mass. METHODS: Thirty-five subjects (12 healthy volunteers and 23 patients with known or suspected coronary artery disease) were investigated. All study participants were imaged at 1.5 Tesla MRI scanner (Achieva, Philips) using an advanced CMR study protocol which included conventional cine and fast-SENC imaging. A newly developed real-time free-breathing SENC imaging technique based on the acquisition of two images with different frequency modulation was employed. RESULTS: All parameters were successfully derived from fast-SENC images with total study time of 105 s (a 15 s scan time and a 90 s post-processing time). There was no significant difference between fast-SENC and cine imaging in the estimation of LV volumes and EF, whereas fast-SENC underestimated LV end-diastolic mass by 7%. CONCLUSION: The single heartbeat fast-SENC technique can be used as a good alternative to cine imaging for the precise calculation of LV volumes and ejection fraction while the technique significantly underestimates LV end-diastolic mass.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Anciano , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Disfunción Ventricular Izquierda/fisiopatología , Flujo de Trabajo , Adulto Joven
9.
Magn Reson Med ; 77(6): 2215-2224, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27404803

RESUMEN

PURPOSE: To examine a novel non-convex star ordering/shutter for reducing the number of breath-holds in cardiac three-dimensional (3D) T1 Mapping MRI with multiple breath-holds. METHODS: A novel ordering, Non-Convex Star (NCS) was designed to acquire 3D volumes in a modified look-locker inversion recovery (MOLLI) T1 mapping sequence to provide more spatial resolution and coverage in fewer breath-holds. The proposed 3D-MOLLI approach using NCS was first validated in two phantoms using artifact power (AP) measurement against the fully sampled phantom. This was followed by an in vivo study in seven swine, in which the T1 values of the left ventricular (LV) myocardium divided into the American Heart Association (AHA) 16-segment model was compared against the reference multislice two-dimensional (2D) clinical reference and 3D volume without NCS breath-hold reduction. RESULTS: NCS breath-hold reduction yielded less AP compared with the matched SENSE accelerated phantom volume (P < 0.0005), and was shown to be optimal at 25% fewer breath-holds. Calculated T1 values from 3D in vivo volumes with/without NCS were comparable in all AHA segments (P = NS), whereas 3D-NCS yielded significantly higher T1 values than 2D at midslice of the LV myocardium in each AHA segment (P < 0.05). CONCLUSION: We successfully demonstrate the feasibility of the NCS approach for a 3D T1 mapping acquisition requiring fewer breath-holds. Magn Reson Med 77:2215-2224, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Contencion de la Respiración , Ventrículos Cardíacos/diagnóstico por imagen , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Técnica de Sustracción , Algoritmos , Animales , Humanos , Imagen por Resonancia Cinemagnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos
10.
Radiology ; 278(2): 578-84, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26158870

RESUMEN

PURPOSE: To assess feasibility and reliability of electrocardiographic (ECG)-gated cardiac magnetic resonance (MR) imaging with a simplified reusable electrode design that does not touch the skin. MATERIALS AND METHODS: In this institutional review board-approved, HIPAA-compliant study, a silicon positioner held four ECG leads and detected ECG signals without requiring shaving, adhesive, or removal of the gown. The patient lies down on the device and the patient's weight ensures good lead contact against patient's gown; electrode gel that soaks through the gown provides electrical contact with the skin. It was tested at 1.5 T on 12 volunteers and 52 patients by using double inversion recovery, steady-state, fast gradient-echo time course perfusion, and delayed inversion recovery sequences. Paired Student t test was used to assess the significance of differences in durations to apply and remove ECG pad and standard leads. Image quality was assessed and rated on a four-point scale by two readers. The ECG signal quality obtained from pad and leads was rated on a five-point scale. Ventricular septal sharpness and signal-to-noise ratio were measured on images generated by ECG gating from pads and standard leads. RESULTS: Application and removal duration was 444 seconds with standard leads compared with 296 seconds with the ECG pad, and mean difference in setup time was 148 seconds (P = .005). Ventricular septal sharpness (1/slope) was 165 for ECG pad and 152 for standard leads (P = .3). Septal signal-to-noise ratio on images generated by cardiac gating with ECG pad was 38 ± 12 (standard deviation) compared with 39 ± 14 for standard leads (P = .7). The qualitative image quality score for ECG pad (3.9 ± 0.19) was comparable to ECG leads (3.8 ± 0.45; P = .47). The mean ECG signal qualitative scores were also comparable (pad vs leads, 4.9 ± 0.43 vs 4.9 ± 0.14, respectively; P = .9). Volunteers preferred the ECG pad and reported that it was comfortable and convenient. ECG pad was successful in 50 of 52 (96%) patients. Two patients, including one with large pleural effusions and another with ventricular tachycardia, were not successfully gated. CONCLUSION: This simplified approach to ECG gating is faster to set up and more convenient and comfortable for patients.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Imagen por Resonancia Magnética/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Carbono , Electrocardiografía , Electrodos , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Control de Infecciones/métodos , Masculino , Persona de Mediana Edad , Silicio
11.
Magn Reson Med ; 74(2): 384-95, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25105469

RESUMEN

PURPOSE: To evaluate the feasibility of accelerated cardiac MR (CMR) perfusion with radial sampling using nonlinear image reconstruction after exercise on an MR-compatible supine bike ergometer. METHODS: Eight healthy subjects were scanned on two separate days using radial and Cartesian CMR perfusion sequences in rest and exercise stress perfusion. Four different methods (standard gridding, conjugate gradient SENSE [CG-SENSE], nonlinear inversion with joint estimation of coil-sensitivity profiles [NLINV] and compressed sensing with a total variation constraint [TV]) were compared for the reconstruction of radial data. Cartesian data were reconstructed using SENSE. All images were assessed by two blinded readers in terms of image quality and diagnostic value. RESULTS: CG-SENSE and NLINV were scored more favorably than TV (in both rest and stress perfusion cases, P < 0.05) and gridding (for rest perfusion cases, P < 0.05). TV images showed patchy artifacts, which negatively influenced image quality especially in the stress perfusion images acquired with a low number of radial spokes. Although CG-SENSE and NLINV received better scores than Cartesian sampling in both rest and exercise stress perfusion cases, these differences were not statistically significant (P > 0.05). CONCLUSION: We have demonstrated the feasibility of accelerated CMR perfusion using radial sampling after physical exercise using a supine bicycle ergometer in healthy subjects. For reconstruction of undersampled radial perfusion, CG-SENSE and NLINV resulted in better image quality than standard gridding or TV reconstruction. Further technical improvements and clinical assessment are needed before using this approach in patients with suspected coronary artery disease.


Asunto(s)
Circulación Coronaria/fisiología , Vasos Coronarios/fisiología , Prueba de Esfuerzo/instrumentación , Prueba de Esfuerzo/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Adulto , Vasos Coronarios/anatomía & histología , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Masculino , Variaciones Dependientes del Observador , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego , Posición Supina
12.
Radiology ; 272(3): 683-9, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24702727

RESUMEN

PURPOSE: To compare accuracy, precision, and reproducibility of four commonly used myocardial T1 mapping sequences: modified Look-Locker inversion recovery (MOLLI), shortened MOLLI (ShMOLLI), saturation recovery single-shot acquisition (SASHA), and saturation pulse prepared heart rate independent inversion recovery (SAPPHIRE). MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board. All subjects provided written informed consent. Accuracy, precision, and reproducibility of the four T1 mapping sequences were first compared in phantom experiments. In vivo analysis was performed in seven healthy subjects (mean age ± standard deviation, 38 years ± 19; four men, three women) who were imaged twice on two separate days. In vivo reproducibility of native T1 mapping and extracellular volume (ECV) were measured. Differences between the sequences were assessed by using Kruskal-Wallis and Wilcoxon rank sum tests (phantom data) and mixed-effect models (in vivo data). RESULTS: T1 mapping accuracy in phantoms was lower with ShMOLLI (62 msec) and MOLLI (44 msec) than with SASHA (13 msec; P < .05) and SAPPHIRE (12 msec; P < .05). MOLLI had similar precision to ShMOLLI (4.0 msec vs 5.6 msec; P = .07) but higher precision than SAPPHIRE (6.8 msec; P = .002) and SASHA (8.7 msec; P < .001). All sequences had similar reproducibility in phantoms (P = .1). The four sequences had similar in vivo reproducibility for native T1 mapping (∼25-50 msec; P > .05) and ECV quantification (∼0.01-0.02; P > .05). CONCLUSION: SASHA and SAPPHIRE yield higher accuracy, lower precision, and similar reproducibility compared with MOLLI and ShMOLLI for T1 measurement. Different sequences yield different ECV values; however, all sequences have similar reproducibility for ECV quantification.


Asunto(s)
Algoritmos , Mapeo del Potencial de Superficie Corporal/métodos , Corazón/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética/instrumentación , Masculino , Análisis Numérico Asistido por Computador , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
13.
Magn Reson Med ; 71(2): 599-607, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23504975

RESUMEN

PURPOSE: Direct 2D tracking of cardiac motion may provide superior respiratory navigator gating for coronary magnetic resonance angiography compared to conventional liver-diaphragm navigators. However, additional 2D processing for motion extraction is unsuitable for real-time prospective gating. In this work, a 2D fat-selective image navigator, which delineates the epicardial fat surrounding coronary arteries, is developed to directly monitor epicardial fat motion at every heartbeat in real-time for prospective gating. METHODS: The proposed navigator is incorporated into a real-time interactive software that allows rapid setup and efficient motion extraction, and runs on standard clinical hardware without any additional dedicated components for processing. The proposed 2D cardiac fat image navigator was compared with the conventional 1D diaphragm navigator in free-breathing b-SSFP coronary MRAs in 12 healthy volunteers at 1.5T. RESULTS: Real-time motion extraction from 2D cardiac fat navigator images was feasible within 20 ms, enabling successful prospectively gated coronary magnetic resonance angiographies in all subjects. Compared to 1D diaphragmatic navigator, 2D fat image navigator reduced scan time by 38% (P < 0.0005), and significantly improved vessel sharpness, myocardial suppression, and image quality (P < 0.05). CONCLUSION: This demonstrates the feasibility of a 3D SSFP coronary magnetic resonance angiography sequence using a 2D epicardial fat image as a navigator for real-time prospective motion tracking.


Asunto(s)
Angiografía Coronaria/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Vasos Coronarios/fisiología , Diafragma/fisiología , Humanos , Programas Informáticos
14.
Ann Thorac Surg Short Rep ; 2(1): 150-155, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38464466

RESUMEN

BACKGROUND: We have developed a tissue engineered cardiac patch derived from a 3-dimensional (3D) myocardial tissue reinforced with extracellular matrix in an effort to enhance in situ myocardial regeneration. The feasibility of the patch was evaluated in a porcine model by various modalities to assess both the constructive and functional aspects of regeneration. METHODS: A spheroid-based 3D multicellular tissue was created using a 3D net mold system that incorporated cardiomyocytes and embryonic fibroblast cells. The 3D multicellular tissue was incorporated with extracellular matrix sheets and surgically implanted into the right ventricle of a healthy porcine model (n = 4). After 60 days, the implanted patches were evaluated by cardiac magnetic resonance imaging and electroanatomic mapping studies as well as by post-euthanasia analyses, including measurements of mechanical viscoelasticity. RESULTS: Cardiac magnetic resonance imaging revealed improved regional tissue perfusion in the patch area. Electroanatomic mapping exhibited regenerated electrical conductivity in the patch, as evidenced by relatively preserved voltage regions (1.11 ± 0.8 mV) in comparison to the normal right ventricle (4.7 ± 2.8 mV). Histologic and tissue analyses confirmed repopulation of site-specific host cells, including premature cardiomyocytes and active vasculogenesis. These findings were supported by quantitative reverse transcription-polymerase chain reaction. CONCLUSIONS: The tissue engineered cardiac patch effectively facilitated in situ constructive and functional myocardial regeneration, characterized by increased regional tissue perfusion and positive electrical activity in the porcine model.

15.
JTCVS Open ; 18: 209-220, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38690440

RESUMEN

Objectives: The complexity of aortic arch reconstruction due to diverse 3-dimensional geometrical abnormalities is a major challenge. This study introduces 3-dimensional printed tissue-engineered vascular grafts, which can fit patient-specific dimensions, optimize hemodynamics, exhibit antithrombotic and anti-infective properties, and accommodate growth. Methods: We procured cardiac magnetic resonance imaging with 4-dimensional flow for native porcine anatomy (n = 10), from which we designed tissue-engineered vascular grafts for the distal aortic arch, 4 weeks before surgery. An optimal shape of the curved vascular graft was designed using computer-aided design informed by computational fluid dynamics analysis. Grafts were manufactured and implanted into the distal aortic arch of porcine models, and postoperative cardiac magnetic resonance imaging data were collected. Pre- and postimplant hemodynamic data and histology were analyzed. Results: Postoperative magnetic resonance imaging of all pigs with 1:1 ratio of polycaprolactone and poly-L-lactide-co-ε-caprolactone demonstrated no specific dilatation or stenosis of the graft, revealing a positive growth trend in the graft area from the day after surgery to 3 months later, with maintaining a similar shape. The peak wall shear stress of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft portion did not change significantly between the day after surgery and 3 months later. Immunohistochemistry showed endothelization and smooth muscle layer formation without calcification of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft. Conclusions: Our patient-specific polycaprolactone/poly-L-lactide-co-ε-caprolactone tissue-engineered vascular grafts demonstrated optimal anatomical fit maintaining ideal hemodynamics and neotissue formation in a porcine model. This study provides a proof of concept of patient-specific tissue-engineered vascular grafts for aortic arch reconstruction.

16.
J Diabetes Sci Technol ; 17(6): 1482-1492, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-35703136

RESUMEN

BACKGROUND: Predicting carbohydrate intake and physical activity in people with diabetes is crucial for improving blood glucose concentration regulation. Patterns of individual behavior can be detected from historical free-living data to predict meal and exercise times. Data collected in free-living may have missing values and forgotten manual entries. While machine learning (ML) can capture meal and exercise times, missing values, noise, and errors in data can reduce the accuracy of ML algorithms. METHODS: Two recurrent neural networks (RNNs) are developed with original and imputed data sets to assess detection accuracy of meal and exercise events. Continuous glucose monitoring (CGM) data, insulin infused from pump data, and manual meal and exercise entries from free-living data are used to predict meals, exercise, and their concurrent occurrence. They contain missing values of various lengths in time, noise, and outliers. RESULTS: The accuracy of RNN models range from 89.9% to 95.7% for identifying the state of event (meal, exercise, both, or neither) for various users. "No meal or exercise" state is determined with 94.58% accuracy by using the best RNN (long short-term memory [LSTM] with 1D Convolution). Detection accuracy with this RNN is 98.05% for meals, 93.42% for exercise, and 55.56% for concurrent meal-exercise events. CONCLUSIONS: The meal and exercise times detected by the RNN models can be used to warn people for entering meal and exercise information to hybrid closed-loop automated insulin delivery systems. Reliable accuracy for event detection necessitates powerful ML and large data sets. The use of additional sensors and algorithms for detecting these events and their characteristics provides a more accurate alternative.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Insulina , Comidas , Ejercicio Físico
17.
Magn Reson Imaging ; 104: 105-114, 2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37820979

RESUMEN

BACKGROUND AND PURPOSE: The purpose of this study was to test the hypothesis that hemodynamically compromised brains exhibit transient changes in magnetic susceptibility throughout the cardiac cycle, and to model these changes using Linear System Theory to extract an index that reflects cerebrovascular reserve. MATERIALS AND METHODS: Eleven patients with angiographically-confirmed intracranial atherosclerotic disease with >50% stenosis were imaged with susceptibility weighted, cardiac-gated single shot images of cerebral Oxygen Extraction Fraction (OEF) at different timepoints of the cardiac cycle. Cardiac gating of the OEF acquisition allowed interrogation of oxygenated blood and the detection of changes throughout the cardiac cycle. Independent component analysis (ICA) of raw k-space data across the cardiac phase allowed MRI signal decomposition into dynamic and static components for image reconstruction. An asymmetry index score of the resultant parametric images were compared to test the hypothesis that variation in hemoglobin-induced susceptibility across the cardiac cycle indeed reflects pathophysiology of cerebrovascular disease. A mathematical model was derived to parameterize physiologic changes induced by the presence of a hemodynamically significant stenosis in the brain as a tissue impulse response parameter (ß). RESULTS: OEF was elevated in the affected hemisphere (50.34 ± 12.13% vs 46.93 ± 12.34%), but failed to reach statistical significance (p < .0796). Transient changes in the OEF signal showed significant distinction between healthy and compromised tissue (0.56 ± 0.067 vs 0.44 ± 0.067, p < .019)). The derived tissue impulse response function was found to be significant as well (10.72 ± 3.48 10-3 ms-1, 9.69 ± 3.51 10-3 ms-1; p < .037). CONCLUSION: In this pilot study, we found transient OEF and ß to be significant predictors of hemispheric compromise.

18.
Eur Heart J Cardiovasc Imaging ; 24(2): 181-189, 2023 01 23.
Artículo en Inglés | MEDLINE | ID: mdl-36458878

RESUMEN

AIMS: Although myocardial scar assessment using late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging is frequently indicated for patients with implantable cardioverter defibrillators (ICDs), metal artefact can degrade image quality. With the new wideband technique designed to mitigate device related artefact, CMR is increasingly used in this population. However, the common clinical indications for CMR referral and impact on clinical decision-making and prognosis are not well defined. Our study was designed to address these knowledge gaps. METHODS AND RESULTS: One hundred seventy-nine consecutive patients with an ICD (age 59 ± 13 years, 75% male) underwent CMR using cine and wideband pulse sequences for LGE imaging. Electronic medical records were reviewed to determine the reason for CMR referral, whether there was a change in clinical decision-making, and occurrence of major adverse cardiac events (MACEs). Referral indication was the most common evaluation of ventricular tachycardia (VT) substrate (n = 114, 64%), followed by cardiomyopathy (n = 53, 30%). Overall, CMR resulted in a new or changed diagnosis in 64 (36%) patients and impacted clinical management in 51 (28%). The effect on management change was highest in patients presenting with VT. A total of 77 patients (43%) experienced MACE during the follow-up period (median 1.7 years), including 65 in patients with evidence of LGE. Kaplan-Meier analysis showed that ICD patients with LGE had worse outcomes than those without LGE (P = 0.006). CONCLUSION: The clinical yield from LGE CMR is high and provides management changing and meaningful prognostic information in a significant proportion of patients with ICDs.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Desfibriladores Implantables/efectos adversos , Medios de Contraste , Imagen por Resonancia Cinemagnética/métodos , Gadolinio , Arritmias Cardíacas/etiología , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas
19.
BioMedInformatics ; 2(2): 297-317, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36968645

RESUMEN

Objective: Interpretation of time series data collected in free-living has gained importance in chronic disease management. Some data are collected objectively from sensors and some are estimated and entered by the individual. In type 1 diabetes (T1D), blood glucose concentration (BGC) data measured by continuous glucose monitoring (CGM) systems and insulin doses administered can be used to detect the occurrences of meals and physical activities and generate the personal daily living patterns for use in automated insulin delivery (AID). Methods: Two challenges in time-series data collected in daily living are addressed: data quality improvement and detection of unannounced disturbances to BGC. CGM data have missing values for varying periods of time and outliers. People may neglect reporting their meal and physical activity information. In this work, novel methods for preprocessing real-world data collected from people with T1D and detection of meal and exercise events are presented. Four recurrent neural network (RNN) models are investigated to detect the occurrences of meals and physical activities disjointly or concurrently. Results: RNNs with long short-term memory (LSTM) with 1D convolution layers and bidirectional LSTM with 1D convolution layers have average accuracy scores of 92.32% and 92.29%, and outper-form other RNN models. The F1 scores for each individual range from 96.06% to 91.41% for these two RNNs. Conclusions: RNNs with LSTM and 1D convolution layers and bidirectional LSTM with 1D convolution layers provide accurate personalized information about the daily routines of individuals. Significance: Capturing daily behavior patterns enables more accurate future BGC predictions in AID systems and improves BGC regulation.

20.
Am J Cardiol ; 174: 143-150, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35487776

RESUMEN

Quantification of myocardial perfusion reserve (MPR) using vasodilator stress cardiac magnetic resonance is increasingly used to detect coronary artery disease. However, MPR can also be altered because of changes in microvascular function. We aimed to determine whether MPR can distinguish between ischemic cardiomyopathy (IC) secondary to coronary artery disease and non-IC (NIC) with microvascular dysfunction and no underlying epicardial coronary disease. A total of 60 patients (mean age 65 ± 14 years, 30% women), including 31 with IC and 29 with NIC, were identified from a pre-existing vasodilator stress cardiac magnetic resonance registry. Short-axis cine slices were used to measure left ventricular ejection fraction (LVEF) using the Simpson method of disks. MPR index (MPRi) was determined from first-pass myocardial perfusion images during stress and rest using the upslope ratio, normalized for the arterial input and corrected for rate pressure product. Patients in both groups were divided into subgroups of LVEF ≤35% and LVEF >35%. Differences in MPRi between the subgroups were examined. MPRi was moderately correlated with LVEF in patients with NIC (r = 0.53, p = 0.03), whereas the correlation in patients with IC was lower (r = 0.32, p = 0.22). Average LVEF in NIC and IC was 34% ± 8% and 35% ± 8%, respectively (p = 0.63). MPRi was not significantly different in IC compared with NIC (1.17 [0.88 to 1.61] vs 1.23 [1.07 to 1.66], p = 0.41), including the subgroups of LVEF (IC: 1.20 ± 0.56 vs NIC: 1.15 ± 0.24, p = 0.75 for LVEF ≤35% and IC: 1.35 ± 0.44 vs NIC: 1.58 ± 0.50, p = 0.19 for LVEF >35%). However, MPRi was significantly lower in patients with LVEF ≤35% compared with those with LVEF>35% (1.17 ± 0.40 vs 1.47 ± 0.47, p = 0.01). Similar difference between LVEF groups was noted in the patients with NIC (1.15 ± 0.24 vs 1.58 ± 0.50, p = 0.006) but not in the patients with IC (1.20 ± 0.56 vs 1.35 ± 0.44, p = 0.42). MPRi can be abnormal in the presence of left ventricular dysfunction with nonischemic etiology. This is a potential pitfall to consider when using this approach to detect ischemia because of epicardial coronary disease using myocardial perfusion imaging.


Asunto(s)
Cardiomiopatías , Enfermedad de la Arteria Coronaria , Anciano , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Circulación Coronaria , Femenino , Humanos , Isquemia , Imagen por Resonancia Cinemagnética/métodos , Masculino , Persona de Mediana Edad , Perfusión , Volumen Sistólico , Vasodilatadores , Función Ventricular Izquierda