Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Circ J ; 87(6): 783-790, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-36990778

RESUMEN

BACKGROUND: Angiographic fractional flow reserve (angioFFR) is a novel artificial intelligence (AI)-based angiography-derived fractional flow reserve (FFR) application. We investigated the diagnostic accuracy of angioFFR to detect hemodynamically relevant coronary artery disease.Methods and Results: Consecutive patients with 30-90% angiographic stenoses and invasive FFR measurements were included in this prospective, single-center study conducted between November 2018 and February 2020. Diagnostic accuracy was assessed using invasive FFR as the reference standard. In patients undergoing percutaneous coronary intervention, gradients of invasive FFR and angioFFR in the pre-senting segments were compared. We assessed 253 vessels (200 patients). The accuracy of angioFFR was 87.7% (95% confidence interval [CI] 83.1-91.5%), with a sensitivity of 76.8% (95% CI 67.1-84.9%), specificity of 94.3% (95% CI 89.5-97.4%), and area under the curve of 0.90 (95% CI 0.86-0.93%). AngioFFR was well correlated with invasive FFR (r=0.76; 95% CI 0.71-0.81; P<0.001). The agreement was 0.003 (limits of agreement: -0.13, 0.14). The FFR gradients of angioFFR and invasive FFR were comparable (n=51; mean [±SD] 0.22±0.10 vs. 0.22±0.11, respectively; P=0.87). CONCLUSIONS: AI-based angioFFR showed good diagnostic accuracy for detecting hemodynamically relevant stenosis using invasive FFR as the reference standard. The gradients of invasive FFR and angioFFR in the pre-stenting segments were comparable.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Estudios Prospectivos , Estenosis Coronaria/diagnóstico por imagen , Inteligencia Artificial , Angiografía Coronaria/métodos , Índice de Severidad de la Enfermedad , Valor Predictivo de las Pruebas
2.
Heart Vessels ; 37(10): 1689-1700, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35524780

RESUMEN

The purpose of the present study was to develop a 60 MHz integrated backscatter intravascular ultrasound (IB-IVUS) and to evaluate its usefulness for the detection of lipid area with backward attenuation of ultrasound signal (AT) that for the prediction of post-procedural myocardial injury (PMI) after percutaneous coronary intervention (PCI). In a pathological study, images were acquired from 221 cross-sections of 18 coronary arteries from 13 cadavers obtained at autopsy. In the clinical training study, we compared non-targeted plaques in 38 patients by a previous IB-IVUS system (38 MHz) and a new IB-IVUS system (60 MHz). In the clinical testing study, we included 70 consecutive patients who underwent PCI. Serum troponin-I was measured just before and 24 h after PCI to evaluate PMI. As the % microcalcification + % cholesterol cleft area increased, the attenuation of IB values increased (r = 0.56, p < 0.001). The slopes of regression lines of the area of each tissue component between 38 and 60 MHz IB-IVUS were excellent. The lipid pool area with AT tended to be more useful than that of the conventional lipid pool area for the prediction of PMI (p = 0.11). We developed a 60 MHz IB-IVUS imaging system for tissue characterization of coronary plaques. Cutoff value of purple color was the most reliable value for the prediction of PMI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Placa Aterosclerótica , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Humanos , Lípidos , Intervención Coronaria Percutánea/efectos adversos , Placa Aterosclerótica/diagnóstico , Placa Aterosclerótica/patología , Ultrasonografía Intervencional/métodos
3.
AJR Am J Roentgenol ; 216(6): 1492-1499, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32876482

RESUMEN

BACKGROUND. For clinical decision making, it was recently recommended that values of fractional flow reserve (FFR) derived from coronary CTA (FFRCT) be measured 1-2 cm distal to the stenosis, given the potential for overestimation of ischemia when FFRCT values at far distal segments are used. Supporting data are, however, lacking. OBJECTIVE. The purpose of the present study was to evaluate the diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis and at more distal locations relative to invasive FFR values. METHODS. FFRCT and invasive FFR values for 365 vessels in 253 patients identified from the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry were prospectively assessed. FFRCT values were measured 1-2 cm distal to the stenosis and at the pressure wire position and far distal segments. The diagnostic accuracy of FFRCT was assessed on the basis of the ROC AUC. The AUC of FFRCT was calculated using FFRCT as an explanatory variable and an invasive FFR of 0.80 or less as the dichotomous dependent variable. RESULTS. The AUC of FFRCT values measured 1-2 cm distal to the stenosis (0.85; 95% CI, 0.80-0.88) was higher (p = .002) than that of FFRCT values measured at far distal segments (0.80; 95% CI, 0.76-0.84) and similar (p = .16) to that of FFRCT values measured at the pressure wire position (0.86; 95% CI, 0.81-0.89). FFRCT values measured 1-2 cm distal to the stenosis and at far distal segments had sensitivity of 87% versus 92% (p = .003), specificity of 73% versus 42% (p < .001), PPV of 75% versus 59% (p < .001), and NPV of 86% versus 85% (p = .72), respectively. Subgroup analyses of lesions of the left anterior descending coronary artery, left circumflex coronary artery, and right coronary artery all showed improved specificity and PPV (all p < .005) for FFRCT values measured 1-2 cm distal to the stenosis compared with values measured at the pressure wire position. However, the AUC was higher for measurements obtained 1-2 cm distal to the stenosis versus those obtained at far distal segments, for left anterior descending coronary artery lesions (p < .001) but not for left circumflex coronary artery lesions (p = .27) or right coronary artery lesions (p = .91). CONCLUSION. The diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis was higher than that of FFRCT values measured at far distal segments and was similar to that of FFRCT values measured at the pressure wire position in evaluating ischemic status, particularly for left anterior descending coronary artery lesions. CLINICAL IMPACT. The present study supports recent recommendations from experts to use FFRCT measured 1-2 cm distal to the stenosis, rather than measurements obtained at far distal segments, in clinical decision making.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Anciano , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
4.
Circ J ; 85(11): 2043-2049, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-34148928

RESUMEN

BACKGROUND: Myocardial perfusion imaging (MPI) and fractional flow reserve (FFR) are established approaches to the assessment of myocardial ischemia. Recently, various FFR cutoff values were proposed, but the diagnostic accuracy of MPI in identifying positive FFR using various cutoff values is not well established.Methods and Results:We retrospectively studied 273 patients who underwent stress MPI and FFR within a 3-month period. Results for FFR were obtained from 218 left anterior descending artery (LAD) lesions and 207 non-LAD lesions. Stress MPI and FFR demonstrated a good correlation in the detection of myocardial ischemia. However, the positive predictive value (PPV) of FFR for detecting MPI-positive lesions at the optimal FFR thresholds was insufficient (44% for LAD and 65% for non-LAD lesions). This was caused by a sharp drop in PPV at an FFR threshold of 0.7 or more. Notably, 41% of the lesions with normal MPI demonstrated FFRs <0.80. However, MPI-negative lesions had an extremely low lesion rate with FFR <0.65 (6%). Conversely, 78% and 41% of MPI-positive lesions had FFR <0.80 and <0.65, respectively. CONCLUSIONS: The data confirmed that decisions based on MPI are reasonable because MPI-negative patients have an extremely low rate of lesions with a FFR below the cutoff point for a hard event, and MPI-positive lesions include many lesions with FFR <0.65.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Imagen de Perfusión Miocárdica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
5.
Catheter Cardiovasc Interv ; 96(4): 773-781, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31691499

RESUMEN

OBJECTIVES: We sought to evaluate the efficacy of plaque debulking by directional coronary atherectomy (DCA) prior to second-generation drug-eluting stent (DES) implantation for bifurcated coronary lesions. BACKGROUND: Percutaneous coronary intervention (PCI) for bifurcated lesions still remains complex and challenging in terms of restenosis or stent thrombosis regardless of whether simple or complex stenting is used. METHODS: Patients with bifurcated lesions were enrolled in this prospective multicenter registry. Pre-second-generation DES plaque debulking with a novel DCA catheter (ATHEROCUT®, Nipro Co., Osaka, Japan) was conducted. All patients were scheduled to perform a follow up angiography (9-12 month coronary angiography or coronary computed tomography). The primary end point was target vessel failure (TVF) at follow up. Secondary end points were procedure-related events and major adverse cardiac events at 1 year. RESULTS: A total of 77 patients with bifurcated lesions were enrolled. PCI with DCA was performed successfully in all cases without any major procedure-related event and only one case required complex stenting. The TVF rate at 9-12 month follow up was 3.9% (3 of 77) and those were all associated with revascularization of the target vessel. Restenosis was only observed at the ostium of the main-branch in three cases. No death, coronary artery bypass grafting, or myocardial infarction were reported for any patients within the first year. CONCLUSION: DCA before second-generation DES implantation can possibly avoid complex stenting and provide a good mid-term outcome in patients with bifurcated lesions.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Placa Aterosclerótica , Anciano , Aterectomía Coronaria/efectos adversos , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional
6.
Circ J ; 84(6): 1034-1038, 2020 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-32321880

RESUMEN

BACKGROUND: The per-vessel level impact of physiological pattern of disease on the discordance between fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) has not been clarified.Methods and Results:Using the AJIP registry, vessels with FFR/iFR discordance (133/671 [19.8%]) were analyzed. In the left anterior descending artery (LAD), physiologically diffuse disease, as assessed by pressure-wire pullback, was associated with FFR-/iFR+ (83.3% [40/48]), while physiologically focal disease was associated with FFR+/iFR- (57.4% [31/54]), significantly (P<0.0001). These differences were not significant in non-LAD (P=0.17). CONCLUSIONS: The impact of physiological pattern of disease on FFR/iFR discordance is more pronounced in the LAD.


Asunto(s)
Cateterismo Cardíaco , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sistema de Registros , Índice de Severidad de la Enfermedad
7.
Catheter Cardiovasc Interv ; 94(2): E61-E66, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-30723996

RESUMEN

OBJECTIVES: The objective was to evaluate the safety, feasibility, and accuracy of the jailed-pressure wire technique using a durable optical fiber-based pressure wire with high-pressure dilatation using a non-compliant balloon after main vessel stenting. BACKGROUND: Fractional flow reserve (FFR) information can help interventionists determine whether they should treat a jailed-side branch (SB). However, re-crossing a pressure wire into a jailed-SB is sometimes technically difficult. METHODS: Fifty-one consecutive lesions from 48 patients who underwent the jailed-pressure wire technique were retrospectively investigated. The primary endpoint was complication rate and secondary endpoints included success rate of FFR measurement, incidence of wire disruption, and final drift rate. The usability of FFR for percutaneous coronary intervention of coronary bifurcation lesion was also evaluated. RESULTS: Median age of the patients was 69 years and 80.4% were men. The most frequent underlying disease was stable angina (70.6%) and 68.6% were type B2 lesions. Our main findings were: the procedure was performed successfully in all cases without any complications or wire disruption, FFR could be measured without significant final drift in 95.9% of cases, and FFR measurements helped interventionists determine whether to perform a final kissing balloon dilatation in 49.0% cases. CONCLUSIONS: The jailed-pressure wire technique using a durable optical fiber-based pressure wire with high-pressure post-dilatation maneuver was safe, feasible, and accurate.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Enfermedad de la Arteria Coronaria/terapia , Tecnología de Fibra Óptica/instrumentación , Fibras Ópticas , Transductores de Presión , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Cateterismo Cardíaco/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Diseño de Equipo , Estudios de Factibilidad , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento
8.
Circ J ; 82(11): 2837-2844, 2018 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-30175800

RESUMEN

BACKGROUND: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress 99 mTc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest 99 mTc-tetrofosmin/stress 201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera.Methods and Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. CONCLUSIONS: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.


Asunto(s)
Angiografía Coronaria , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica , Compuestos Organofosforados/administración & dosificación , Compuestos de Organotecnecio/administración & dosificación , Radioisótopos de Talio/administración & dosificación , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Anciano de 80 o más Años , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
10.
Catheter Cardiovasc Interv ; 88(6): 1002-1005, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-26577494

RESUMEN

Alcohol septal ablation is widely accepted as a therapeutic option for the treatment of hypertrophic obstructive cardiomyopahty. The selection of an appropriate target vessel is key for an effective and safe procedure. The target vessel sometimes bifurcates from the non-left anterior descending coronary artery, in which case these vessels are sometimes difficult to select with a wire and deliver a balloon catheter. The combined use of a microcatheter and a balloon catheter is one of the choices for treatment of patients with this type of challenging anatomy. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Técnicas de Ablación/métodos , Cateterismo Cardíaco/métodos , Cardiomiopatía Hipertrófica/cirugía , Etanol/administración & dosificación , Tabiques Cardíacos/cirugía , Anciano , Cardiomiopatía Hipertrófica/diagnóstico , Ecocardiografía , Femenino , Tabiques Cardíacos/diagnóstico por imagen , Humanos
12.
Cardiovasc Ultrasound ; 14: 6, 2016 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-26817595

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is associated with left atrial (LA) remodeling caused by pressure and/or volume (LAV) overload. Increased pulmonary capillary wedge pressure (PCWP) represents LA pressure overload. We recently reported that pulmonary capillary wedge pressure (ePCWP) can be estimated by the kinetics-tracking (KT) index that combines LA function and volume using speckle tracking echocardiography (STE), and has a strong correlation with PCWP measured by right heart catheterization (r = 0.92). Therefore, we hypothesized that ePCWP is the best echocardiographic predictor of successful AF ablation. METHODS: We enrolled 137 patients with paroxysmal AF (age: 61 ± 10 years) who underwent pulmonary vein isolation. We measured LAV index, LA emptying function (EF) and LA stiffness during sinus rhythm before ablation using STE. PCWP was noninvasively estimated by STE as we previously reported. Parameters were compared between a group with AF recurrence (n = 30, age: 59 ± 11 years) and a group with successful ablation (sinus rhythm maintained for >1 year) (n = 107, age 61 ± 11 years). RESULTS: The ePCWP was correlated with PCWP measured by right heart catheterization (r = 0.76, p < 0.01). Compared with the non-recurrence group (n = 107, age: 61 ± 11), the AF recurrence group had significantly increased ePCWP (10.6 ± 3.5 vs 14.6 ± 2.9 mmHg, p < 0.01), minimum LAV index (29 ± 12 ml/m(2) vs 37 ± 14 ml/m(2), p < 0.01) and LA stiffness (0.47 ± 0.33 vs 0.83 ± 0.59, p < 0.01), but lower total LA EF (44 ± 11% vs 39 ± 13%, p < 0.01) before ablation. In multivariate logistic regression analysis, ePCWP was the most significant independent predictor of successful ablation. Using 13 mmHg of PCWP as the optimal cutoff value, the sensitivity and specificity for successful ablation were 73 and 77% (area under the curve = 0.81), respectively. CONCLUSION: The ePCWP that is measured by the combination of LA function and volume before ablation was a better predictor of the successful ablation compared with LA function and volume separately. The ePCWP estimated by STE is useful to predict the successful ablation in paroxysmal AF, and could be useful to improve candidate selection for AF ablation.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Determinación de la Presión Sanguínea/métodos , Ecocardiografía/métodos , Interpretación de Imagen Asistida por Computador/métodos , Presión Esfenoidal Pulmonar , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
13.
Circulation ; 128(5): 512-23, 2013 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-23804254

RESUMEN

BACKGROUND: Pulmonary arterial hypertension (PAH) is characterized by dysregulated proliferation of pulmonary artery smooth muscle cells leading to (mal)adaptive vascular remodeling. In the systemic circulation, vascular injury is associated with downregulation of sarcoplasmic reticulum Ca(2+)-ATPase 2a (SERCA2a) and alterations in Ca(2+) homeostasis in vascular smooth muscle cells that stimulate proliferation. We, therefore, hypothesized that downregulation of SERCA2a is permissive for pulmonary vascular remodeling and the development of PAH. METHODS AND RESULTS: SERCA2a expression was decreased significantly in remodeled pulmonary arteries from patients with PAH and the rat monocrotaline model of PAH in comparison with controls. In human pulmonary artery smooth muscle cells in vitro, SERCA2a overexpression by gene transfer decreased proliferation and migration significantly by inhibiting NFAT/STAT3. Overexpresion of SERCA2a in human pulmonary artery endothelial cells in vitro increased endothelial nitric oxide synthase expression and activation. In monocrotaline rats with established PAH, gene transfer of SERCA2a via intratracheal delivery of aerosolized adeno-associated virus serotype 1 (AAV1) carrying the human SERCA2a gene (AAV1.SERCA2a) decreased pulmonary artery pressure, vascular remodeling, right ventricular hypertrophy, and fibrosis in comparison with monocrotaline-PAH rats treated with a control AAV1 carrying ß-galactosidase or saline. In a prevention protocol, aerosolized AAV1.SERCA2a delivered at the time of monocrotaline administration limited adverse hemodynamic profiles and indices of pulmonary and cardiac remodeling in comparison with rats administered AAV1 carrying ß-galactosidase or saline. CONCLUSIONS: Downregulation of SERCA2a plays a critical role in modulating the vascular and right ventricular pathophenotype associated with PAH. Selective pulmonary SERCA2a gene transfer may offer benefit as a therapeutic intervention in PAH.


Asunto(s)
Hipertensión Pulmonar/terapia , Monocrotalina/toxicidad , ATPasas Transportadoras de Calcio del Retículo Sarcoplásmico/genética , ATPasas Transportadoras de Calcio del Retículo Sarcoplásmico/uso terapéutico , Animales , Células Cultivadas , Modelos Animales de Enfermedad , Regulación hacia Abajo/efectos de los fármacos , Regulación hacia Abajo/genética , Hipertensión Pulmonar Primaria Familiar , Técnicas de Transferencia de Gen , Células HEK293 , Ventrículos Cardíacos/metabolismo , Ventrículos Cardíacos/patología , Humanos , Hipertensión Pulmonar/inducido químicamente , Hipertensión Pulmonar/enzimología , Masculino , Músculo Liso Vascular/efectos de los fármacos , Músculo Liso Vascular/metabolismo , Miocitos del Músculo Liso/efectos de los fármacos , Miocitos del Músculo Liso/metabolismo , Distribución Aleatoria , Ratas , Ratas Sprague-Dawley , ATPasas Transportadoras de Calcio del Retículo Sarcoplásmico/biosíntesis , Resultado del Tratamiento
14.
Am J Physiol Heart Circ Physiol ; 307(10): H1478-86, 2014 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-25217654

RESUMEN

Large animal studies are an important step toward clinical translation of novel therapeutic approaches. We aimed to establish an ischemic heart failure (HF) model with a larger myocardial infarction (MI) relative to previous studies, and characterize the functional and structural features of this model. An MI was induced by occluding the proximal left anterior descending artery (LAD; n = 15) or the proximal left circumflex artery (LCx; n = 6) in Yorkshire pigs. Three pigs with sham procedures were also included. All pigs underwent hemodynamic and echocardiographic assessments before MI, at 1 mo, and 3 mo after MI. Analyses of left ventricular (LV) myocardial mechanics by means of strains and torsion were performed using speckle-tracking echocardiography and compared between the groups. The proximal LAD MI approach induced larger infarct sizes (14.2 ± 3.2% vs. 10.6 ± 1.9%, P = 0.03), depressed systolic function (LV ejection fraction; 39.8 ± 7.5% vs. 54.1 ± 4.6%, P < 0.001), and more LV remodeling (end-systolic volume index; 82 ± 25 ml/m(2) vs. 51 ± 18 ml/m(2), P = 0.02, LAD vs. LCx, respectively) compared with the LCx MI approach without compromising the survival rate. At the papillary muscle level, echocardiographic strain analysis revealed no differences in radial and circumferential strain between LAD and LCx MIs. However, in contrast with the LCx MI, the LAD MI resulted in significantly decreased longitudinal strain. The proximal LAD MI model induces more LV remodeling and depressed LV function relative to the LCx MI model. Location of MI significantly impacts the severity of HF, thus careful consideration is required when choosing an MI model for preclinical HF studies.


Asunto(s)
Oclusión Coronaria/complicaciones , Insuficiencia Cardíaca/etiología , Infarto del Miocardio/etiología , Animales , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/fisiopatología , Modelos Animales de Enfermedad , Ecocardiografía Doppler en Color , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Contracción Miocárdica , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/fisiopatología , Miocardio/patología , Índice de Severidad de la Enfermedad , Estrés Mecánico , Volumen Sistólico , Porcinos , Factores de Tiempo , Función Ventricular Izquierda , Remodelación Ventricular
15.
Am J Cardiol ; 216: 54-62, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38402924

RESUMEN

Alcohol septal ablation (ASA) is performed for symptomatic drug-refractory hypertrophic obstructive cardiomyopathy to reduce the left ventricular outflow tract pressure gradient (LVOTPG) by injecting ethanol into a septal branch that perforates the septal bulge. The target septal branches usually arise directly from the left anterior descending (LAD) artery; however, vessels from a non-LAD artery can be selected in some cases. This study aimed to compare the effectiveness and safety between ASA performed using a septal branch arising from a non-LAD artery and a branch arising from the LAD artery. This single-center, retrospective, observational cohort study comprised patients with hypertrophic obstructive cardiomyopathy who underwent ASA at the Gifu Heart Centre between 2011 and 2022. The effectiveness and safety of ASA using the 2 artery types were compared. The primary end points were LVOTPG and procedure success, determined as LVOTPG <30 mm Hg after 1 year. Of 33 patients (mean age 66.4 ± 13.0 years, 13 men), 18 patients who underwent ASA using only LAD branches and 15 patients who underwent ASA using only non-LAD branches demonstrated no significant difference in the decrease in LVOTPG during the follow-up period (-99.1 ± 47.4 mm Hg/year vs -75.7 ± 39.2 mm Hg/year, respectively, p = 0.19). The procedure success at 1 year was not significantly different between the 2 groups (93.3% and 84.6%, respectively, p = 0.58). ASA performed using septal branches from non-LAD arteries could be an alternative treatment approach when appropriate septal branches are missing or desirable effects cannot be obtained from ASA using LAD branches.


Asunto(s)
Técnicas de Ablación , Cardiomiopatía Hipertrófica , Anciano , Humanos , Masculino , Persona de Mediana Edad , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Etanol/uso terapéutico , Tabiques Cardíacos/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Femenino
16.
Eur Heart J Case Rep ; 8(1): ytad638, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38188194

RESUMEN

Background: Exercise-induced vasospastic angina (VSA) is a relatively uncommon clinical scenario and is difficult to diagnose in the catheterization laboratory. Case summary: A 61-year-old Japanese man presented to our hospital with complaints of angina upon exertion in the morning. Neither a 12-lead electrocardiogram nor an echocardiogram showed any abnormal findings. Invasive coronary angiogram revealed moderate stenosis in the left anterior descending coronary artery. A hand grip test was performed, during which the patient experienced chest pain, and coronary angiogram showed coronary spasm at the site of organic stenosis with delayed coronary flow. Intracoronary nitrates (300 ug) were administered, resulting in the release of coronary spasm. Conclusion: The hand grip test may serve as a useful method for diagnosing exercise-induced VSA in the catheterization laboratory.

17.
Cardiovasc Interv Ther ; 39(2): 109-125, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38367157

RESUMEN

Invasive functional coronary angiography (FCA), an angiography-derived physiological index of the functional significance of coronary obstruction, is a novel physiological assessment tool for coronary obstruction that does not require the utilization of a pressure wire. This technology enables operators to rapidly evaluate the functional relevance of coronary stenoses during and even after angiography while reducing the burden of cost and complication risks related to the pressure wire. FCA can be used for treatment decision-making for revascularization, strategy planning for percutaneous coronary intervention, and procedure optimization. Currently, various software-computing FCAs are available worldwide, with unique features in their computation algorithms and functions. With the emerging application of this novel technology in various clinical scenarios, the Japanese Association of Cardiovascular Intervention and Therapeutics task force was created to outline expert consensus on the clinical use of FCA. This consensus document advocates optimal clinical applications of FCA according to currently available evidence while summarizing the concept, history, limitations, and future perspectives of FCA along with globally available software.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Angiografía Coronaria/métodos , Consenso , Japón , Reserva del Flujo Fraccional Miocárdico/fisiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Valor Predictivo de las Pruebas
18.
Cardiovasc Interv Ther ; 39(3): 241-251, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38642290

RESUMEN

Despite guideline-based recommendation of the interchangeable use of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) to guide revascularization decision-making, iFR/FFR could demonstrate different physiological or clinical outcomes in some specific patient or lesion subsets. Therefore, we sought to investigate the impact of difference between iFR and FFR-guided revascularization decision-making on clinical outcomes in patients with left main disease (LMD). In this international multicenter registry of LMD with physiological interrogation, we identified 275 patients in whom physiological assessment was performed with both iFR/FFR. Major adverse cardiovascular event (MACE) was defined as a composite of death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The receiver-operating characteristic analysis was performed for both iFR/FFR to predict MACE in respective patients in whom revascularization was deferred and performed. In 153 patients of revascularization deferral, MACE occurred in 17.0% patients. The optimal cut-off values of iFR and FFR to predict MACE were 0.88 (specificity:0.74; sensitivity:0.65) and 0.76 (specificity:0.81; sensitivity:0.46), respectively. The area under the curve (AUC) was significantly higher for iFR than FFR (0.74; 95%CI 0.62-0.85 vs. 0.62; 95%CI 0.48-0.75; p = 0.012). In 122 patients of coronary revascularization, MACE occurred in 13.1% patients. The optimal cut-off values of iFR and FFR were 0.92 (specificity:0.93; sensitivity:0.25) and 0.81 (specificity:0.047; sensitivity:1.00), respectively. The AUCs were not significantly different between iFR and FFR (0.57; 95%CI 0.40-0.73 vs. 0.46; 95%CI 0.31-0.61; p = 0.43). While neither baseline iFR nor FFR was predictive of MACE in patients in whom revascularization was performed, iFR-guided deferral seemed to be safer than FFR-guided deferral.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Reserva del Flujo Fraccional Miocárdico/fisiología , Masculino , Femenino , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico , Persona de Mediana Edad , Angiografía Coronaria , Sistema de Registros , Revascularización Miocárdica/métodos , Curva ROC , Cateterismo Cardíaco/métodos , Estudios Retrospectivos
19.
Cardiovasc Revasc Med ; 59: 60-66, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37612169

RESUMEN

BACKGROUND: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. AIMS: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. METHODS: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. RESULTS: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. CONCLUSION: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease.


Asunto(s)
Cardiólogos , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Isquemia , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
20.
Catheter Cardiovasc Interv ; 82(4): E459-64, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-23359324

RESUMEN

In this case report, physiological changes of myocardial perfusion in the collateral recipient right coronary artery (RCA) and the collateral donor left anterior descending artery (LAD) with an intermediate lesion were assessed using intracoronary pressure measurement, before and after revascularization of chronic total occlusion (CTO). A 44-year-old male was referred for a catheter examination due to silent myocardial ischemia. An invasive coronary angiogram revealed diffuse narrowing of the RCA with focal occlusive segments in addition to intermediate stenosis in the LAD. A well developed collateral channel from the LAD to the RCA was also confirmed. Fractional flow reserve (FFRmyo) of the LAD before opening the RCA was 0.81. After successful revascularization of the RCA, FFRmyo of the LAD and the RCA were measured with and without an RCA balloon occlusion. Because collateral fractional flow reserve (FFRcoll) of the RCA could be regarded as FFRmyo before revascularization, FFRmyo of the RCA increased from 0.67 to 0.90, meaning a 23% increase of maximum flow by intervention. Interestingly, improvement of FFRmyo of the LAD from 0.81 to 0.93 was also observed, which means a 12% increase of maximum flow. Coronary steal in the LAD was reconfirmed by dramatic worsening of FFRmyo from 0.93 to 0.77 by an RCA balloon occlusion. This phenomenon may be explained by an immediate recruitment of collateral channels. This case clearly demonstrated that CTO opening improves perfusion in not only myocardium supplied by the CTO vessel, but also in that which is supplied by a contralateral collateral donor artery.


Asunto(s)
Presión Sanguínea , Cateterismo Cardíaco , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/terapia , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Adulto , Velocidad del Flujo Sanguíneo , Enfermedad Crónica , Circulación Colateral , Angiografía Coronaria , Oclusión Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Humanos , Masculino , Flujo Sanguíneo Regional , Tomografía de Coherencia Óptica , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA