Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
JAMA ; 325(12): 1173-1184, 2021 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-33755077

RESUMEN

Importance: Although most critically ill patients receive invasive mechanical ventilation (IMV), few studies have characterized how IMV is discontinued in practice. Objective: To describe practice variation in IMV discontinuation internationally, associations between initial discontinuation events and outcomes, and factors associated with the use of select discontinuation strategies and failed initial spontaneous breathing trials (SBTs). Design, Setting, and Participants: Prospective, multinational, observational study of critically ill adults who received IMV for at least 24 hours from 142 intensive care units (ICUs) in 19 countries within 6 regions (27 in Canada, 23 in India, 22 in the UK, 26 in Europe, 21 in Australia/New Zealand, and 23 in the US). Exposures: Receiving IMV. Main Outcomes and Measures: Primary analyses characterized types of initial IMV discontinuation events (extubation, SBT, or tracheostomy) and associations with clinical outcomes (including duration of ventilation, ICU and hospital mortality, and ICU and hospital length of stay). Secondary analyses examined the associations between SBT outcome and SBT timing and clinical outcomes. Results: Among 1868 patients (median [interquartile range] age, 61.8 [48.9-73.1] years; 1173 [62.8%] men) 424 (22.7%) underwent direct extubation, 930 (49.8%) had an initial SBT (761 [81.8%] successful), 150 (8.0%) underwent direct tracheostomy, and 364 (19.5%) died before a weaning attempt. Across regions, there was variation in the use of written directives to guide care, daily screening, SBT techniques, ventilator modes, and the roles played by clinicians involved in weaning. Compared with initial direct extubation, patients who had an initial SBT had higher ICU mortality (20 [4.7%] vs 96 [10.3%]; absolute difference, 5.6% [95% CI, 2.6%-8.6%]), longer duration of ventilation (median of 2.9 vs 4.1 days; absolute difference, 1.2 days [95% CI, 0.7-1.6]), and longer ICU stay (median of 6.7 vs 8.1 days; absolute difference, 1.4 days [95% CI, 0.8-2.4]). Patients whose initial SBT failed (vs passed) had higher ICU mortality (29 [17.2%] vs 67 [8.8%]; absolute difference, 8.4% [95% CI, 2.0%-14.7%]), longer duration of ventilation (median of 6.1 vs 3.5 days; absolute difference, 2.6 days [95% CI, 1.6-3.6]), and longer ICU stay (median of 10.6 vs 7.7 days; absolute difference, 2.8 days [95% CI, 1.1-5.2]). Compared with patients who underwent early initial SBTs, patients who underwent late initial SBTs (>2.3 days after intubation) had longer duration of ventilation (median of 2.1 vs 6.1 days; absolute difference, 4.0 days [95% CI, 3.7-4.5]), longer ICU stay (median of 5.9 vs 10.8 days; absolute difference, 4.9 days [95% CI, 4.0-6.3]), and longer hospital stay (median of 14.3 vs 22.8 days; absolute difference, 8.5 days [95% CI, 6.0-11.0]). Conclusions and Relevance: In this observational study of invasive mechanical ventilation discontinuation in 142 ICUs in Canada, India, the UK, Europe, Australia/New Zealand, and the US from 2013 to 2016, weaning practices varied internationally. Trial Registration: ClinicalTrials.gov Identifier: NCT03955874.


Asunto(s)
Enfermedad Crítica/terapia , Desconexión del Ventilador/métodos , Adulto , Anciano , Femenino , Humanos , Unidades de Cuidados Intensivos , Modelos Lineales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Respiración Artificial , Resultado del Tratamiento
2.
Thorax ; 72(2): 182-185, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27965411

RESUMEN

Acute respiratory distress syndrome (ARDS) is a neutrophil-dominant disorder with no effective pharmacological therapies. While the cyclin-dependent kinase inhibitor AT7519 induces neutrophil apoptosis to promote inflammation resolution in preclinical models of lung inflammation, its potential efficacy in ARDS has not been examined. Untreated peripheral blood sepsis-related ARDS neutrophils demonstrated prolonged survival after 20 hours in vitro culture. AT7519 was able to override this phenotype to induce apoptosis in ARDS neutrophils with reduced expression of the pro-survival protein Mcl-1. We demonstrate the first pharmacological compound to induce neutrophil apoptosis in sepsis-related ARDS, highlighting cyclin-dependent kinase inhibitors as potential novel therapeutic agents.


Asunto(s)
Apoptosis/efectos de los fármacos , Neutrófilos/efectos de los fármacos , Piperidinas/uso terapéutico , Pirazoles/uso terapéutico , Síndrome de Dificultad Respiratoria/tratamiento farmacológico , Síndrome de Dificultad Respiratoria/etiología , Sepsis/complicaciones , Adulto , Anciano , Biomarcadores/sangre , Estudios de Casos y Controles , Citocinas/sangre , Ensayo de Inmunoadsorción Enzimática , Femenino , Citometría de Flujo , Humanos , Masculino , Persona de Mediana Edad , Tasa de Supervivencia
3.
Thorax ; 70(1): 41-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25298325

RESUMEN

BACKGROUND: Excessive use of empirical antibiotics is common in critically ill patients. Rapid biomarker-based exclusion of infection may improve antibiotic stewardship in ventilator-acquired pneumonia (VAP). However, successful validation of the usefulness of potential markers in this setting is exceptionally rare. OBJECTIVES: We sought to validate the capacity for specific host inflammatory mediators to exclude pneumonia in patients with suspected VAP. METHODS: A prospective, multicentre, validation study of patients with suspected VAP was conducted in 12 intensive care units. VAP was confirmed following bronchoscopy by culture of a potential pathogen in bronchoalveolar lavage fluid (BALF) at >10(4) colony forming units per millilitre (cfu/mL). Interleukin-1 beta (IL-1ß), IL-8, matrix metalloproteinase-8 (MMP-8), MMP-9 and human neutrophil elastase (HNE) were quantified in BALF. Diagnostic utility was determined for biomarkers individually and in combination. RESULTS: Paired BALF culture and biomarker results were available for 150 patients. 53 patients (35%) had VAP and 97 (65%) patients formed the non-VAP group. All biomarkers were significantly higher in the VAP group (p<0.001). The area under the receiver operator characteristic curve for IL-1ß was 0.81; IL-8, 0.74; MMP-8, 0.76; MMP-9, 0.79 and HNE, 0.78. A combination of IL-1ß and IL-8, at the optimal cut-point, excluded VAP with a sensitivity of 100%, a specificity of 44.3% and a post-test probability of 0% (95% CI 0% to 9.2%). CONCLUSIONS: Low BALF IL-1ß in combination with IL-8 confidently excludes VAP and could form a rapid biomarker-based rule-out test, with the potential to improve antibiotic stewardship.


Asunto(s)
Líquido del Lavado Bronquioalveolar/química , Citocinas/metabolismo , Neumonía Asociada al Ventilador/diagnóstico , Biomarcadores/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Neumonía Asociada al Ventilador/metabolismo , Estudios Prospectivos , Reproducibilidad de los Resultados
4.
Intensive Care Med ; 49(10): 1181-1190, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37736783

RESUMEN

PURPOSE: The aim of this study was to characterize differences in directives to limit treatments and discontinue invasive mechanical ventilation (IMV) in elderly (65-80 years) and very elderly (> 80 years) intensive care unit (ICU) patients. METHODS: We prospectively described new written orders to limit treatments, IMV discontinuation strategies [direct extubation, direct tracheostomy, spontaneous breathing trial (SBT), noninvasive ventilation (NIV) use], and associations between initial failed SBT and outcomes in 142 ICUs from 6 regions (Canada, India, United Kingdom, Europe, Australia/New Zealand, United States). RESULTS: We evaluated 788 (586 elderly; 202 very elderly) patients. Very elderly (vs. elderly) patients had similar withdrawal orders but significantly more withholding orders, especially cardiopulmonary resuscitation and dialysis, after ICU admission [67 (33.2%) vs. 128 (21.9%); p = 0.002]. Orders to withhold reintubation were written sooner in very elderly (vs. elderly) patients [4 (2-8) vs. 7 (4-13) days, p = 0.02]. Very elderly and elderly patients had similar rates of direct extubation [39 (19.3%) vs. 113 (19.3%)], direct tracheostomy [10 (5%) vs. 40 (6.8%)], initial SBT [105 (52%) vs. 302 (51.5%)] and initial successful SBT [84 (80%) vs. 245 (81.1%)]. Very elderly patients experienced similar ICU outcomes (mortality, length of stay, duration of ventilation) but higher hospital mortality [26 (12.9%) vs. 38 (6.5%)]. Direct tracheostomy and initial failed SBT were associated with worse outcomes. Regional differences existed in withholding orders at ICU admission and in withholding and withdrawal orders after ICU admission. CONCLUSIONS: Very elderly (vs. elderly) patients had more orders to withhold treatments after ICU admission and higher hospital mortality, but similar ICU outcomes and IMV discontinuation. Significant regional differences existed in withholding and withdrawal practices.


Asunto(s)
Ventilación no Invasiva , Respiración Artificial , Humanos , Anciano , Diálisis Renal , Desconexión del Ventilador , Respiración , Unidades de Cuidados Intensivos , Extubación Traqueal
5.
Thorax ; 65(3): 201-7, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19825784

RESUMEN

BACKGROUND: Ventilator-associated pneumonia (VAP) is the most commonly fatal nosocomial infection. Clinical diagnosis of VAP remains notoriously inaccurate. The hypothesis was tested that significantly augmented inflammatory markers distinguish VAP from conditions closely mimicking VAP. METHODS: A prospective, observational cohort study was carried out in two university hospital intensive care units recruiting 73 patients with clinically suspected VAP, and a semi-urban primary care practice recruiting a reference group of 21 age- and sex-matched volunteers. Growth of pathogens at >10(4) colony-forming units (cfu)/ml of bronchoalveolar lavage fluid (BALF) distinguished VAP from "non-VAP". Inflammatory mediators were quantified in BALF and serum. Mediators showing significant differences between patients with and without VAP were analysed for diagnostic utility by receiver operator characteristic (ROC) curves. RESULTS: Seventy-two patients had recoverable lavage-24% had VAP. BALF interleukin-1beta (IL-1beta), IL-8, granulocyte colony-stimulating factor and macrophage inflammatory protein-1alpha were significantly higher in the VAP group (all p<0.005). Using a cut-off of 10 pg/ml, BALF IL-1beta generated negative likelihood ratios for VAP of 0.09. In patients with BALF IL-1beta <10 pg/ml the post-test probability of VAP was 2.8%. Using a cut-off value for IL-8 of 2 ng/ml, the positive likelihood ratio was 5.03. There was no difference in cytokine levels between patients with sterile BALF and those with growth of <10(4) cfu/ml. CONCLUSIONS: BALF IL-1beta and IL-8 are amongst the strongest markers yet identified for accurately demarcating VAP within the larger population of patients with suspected VAP. These findings have potential implications for reduction in unnecessary antibiotic use but require further validation in larger populations.


Asunto(s)
Interleucina-1beta/análisis , Interleucina-8/análisis , Neumonía Asociada al Ventilador/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/análisis , Líquido del Lavado Bronquioalveolar/química , Líquido del Lavado Bronquioalveolar/microbiología , Métodos Epidemiológicos , Femenino , Humanos , Mediadores de Inflamación/análisis , Masculino , Persona de Mediana Edad , Neumonía Asociada al Ventilador/microbiología , Adulto Joven
6.
Am J Respir Crit Care Med ; 180(1): 19-28, 2009 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-19324972

RESUMEN

RATIONALE: Critically ill patients are highly susceptible to hospital-acquired infection. Neutrophil function in critical illness remains poorly understood. OBJECTIVES: To characterize and define mechanisms of peripheral blood neutrophil (PBN) dysfunction in critically ill patients. To determine whether the inflamed lung contributes additional phagocytic impairment. METHODS: Prospective collection of blood and bronchoalveolar lavage fluid from patients with suspected ventilator-associated pneumonia and from age- and sex-matched volunteers; laboratory analysis of neutrophil functions. MEASUREMENTS AND MAIN RESULTS: Seventy-two patients and 21 volunteers were included. Phagocytic capacity of PBNs was 36% lower in patients than in volunteers (P < 0.0001). From several biologically plausible candidates only activated complement was significantly associated with impaired PBN phagocytosis (P < 0.0001). Phagocytosis was negatively correlated with serum C3a and positively correlated with expression of C5a receptor type 1 (CD88) on PBNs. C5a recapitulated impaired PBN phagocytosis and significantly down-regulated CD88 expression in vitro. C5a-mediated phagocytic impairment was prevented by blocking either CD88 or phosphoinositide 3-kinase, and completely reversed by granulocyte-macrophage colony-stimulating factor. C5a also impaired killing of Pseudomonas aeruginosa by, and migration of, PBNs, indicating that effects were not restricted to phagocytosis. Bronchoalveolar lavage fluid leukocytes from patients also demonstrated significantly impaired function, and lavage supernatant reduced phagocytosis in healthy neutrophils by 43% (P = 0.0001). However, lavage fluid did not affect CD88 expression and lavage-mediated impairment of phagocytosis was not blocked by anti-CD88 antibody. CONCLUSIONS: Critically ill patients have significant dysfunction of PBNs, which is mediated predominantly by activated complement. Further, profound complement-independent neutrophil dysfunction occurs in the inflamed lung.


Asunto(s)
Complemento C5a/fisiología , Neutrófilos/fisiología , Fagocitosis/fisiología , Neumonía Asociada al Ventilador/sangre , Receptores de Complemento/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Líquido del Lavado Bronquioalveolar/química , Líquido del Lavado Bronquioalveolar/inmunología , Estudios de Casos y Controles , Complemento C3a/análisis , Complemento C3a/fisiología , Complemento C5a/análisis , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neumonía Asociada al Ventilador/inmunología , Receptor de Anafilatoxina C5a
7.
Wellcome Open Res ; 5: 254, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-35169637

RESUMEN

Background: This study aimed to determine the sensitivity and specificity of reverse transcription PCR (RT-PCR) testing of upper respiratory tract (URT) samples from hospitalised patients with coronavirus disease 2019 (COVID-19), compared to the gold standard of a clinical diagnosis. Methods: All URT RT-PCR testing for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in NHS Lothian, Scotland, United Kingdom between the 7 th of February and 19 th April 2020 (inclusive) was reviewed, and hospitalised patients were identified. All URT RT-PCR tests were analysed for each patient to determine the sequence of negative and positive results. For those who were tested twice or more but never received a positive result, case records were reviewed, and a clinical diagnosis of COVID-19 allocated based on clinical features, discharge diagnosis, and radiology and haematology results. For those who had a negative RT-PCR test but a clinical diagnosis of COVID-19, respiratory samples were retested using a multiplex respiratory panel, a second SARS-CoV-2 RT-PCR assay, and a human RNase P control. Results: Compared to the gold standard of a clinical diagnosis of COVID-19, the sensitivity of a single upper respiratory tract RT-PCR for COVID-19 was 82.2% (95% confidence interval 79.0-85.1%).   The sensitivity of two upper respiratory tract RT-PCR tests increased sensitivity to 90.6% (CI 88.0-92.7%). A further 2.2% and 0.9% of patients who received a clinical diagnosis of COVID-19 were positive on a third and fourth test; this may be an underestimate of the value of further testing as the majority of patients 93.0% (2999/3226) only had one or two URT RT-PCR tests. Conclusions: The sensitivity of a single RT-PCR test of URT samples in hospitalised patients is 82.2%. Sensitivity increases to 90.6% when patients are tested twice.  A proportion of cases with clinically defined COVID-19 never test positive on URT RT-PCR despite repeat testing.

8.
Lancet Respir Med ; 8(2): 182-191, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31810865

RESUMEN

BACKGROUND: Ventilator-associated pneumonia is the most common intensive care unit (ICU)-acquired infection, yet accurate diagnosis remains difficult, leading to overuse of antibiotics. Low concentrations of IL-1ß and IL-8 in bronchoalveolar lavage fluid have been validated as effective markers for exclusion of ventilator-associated pneumonia. The VAPrapid2 trial aimed to determine whether measurement of bronchoalveolar lavage fluid IL-1ß and IL-8 could effectively and safely improve antibiotic stewardship in patients with clinically suspected ventilator-associated pneumonia. METHODS: VAPrapid2 was a multicentre, randomised controlled trial in patients admitted to 24 ICUs from 17 National Health Service hospital trusts across England, Scotland, and Northern Ireland. Patients were screened for eligibility and included if they were 18 years or older, intubated and mechanically ventilated for at least 48 h, and had suspected ventilator-associated pneumonia. Patients were randomly assigned (1:1) to biomarker-guided recommendation on antibiotics (intervention group) or routine use of antibiotics (control group) using a web-based randomisation service hosted by Newcastle Clinical Trials Unit. Patients were randomised using randomly permuted blocks of size four and six and stratified by site, with allocation concealment. Clinicians were masked to patient assignment for an initial period until biomarker results were reported. Bronchoalveolar lavage was done in all patients, with concentrations of IL-1ß and IL-8 rapidly determined in bronchoalveolar lavage fluid from patients randomised to the biomarker-based antibiotic recommendation group. If concentrations were below a previously validated cutoff, clinicians were advised that ventilator-associated pneumonia was unlikely and to consider discontinuing antibiotics. Patients in the routine use of antibiotics group received antibiotics according to usual practice at sites. Microbiology was done on bronchoalveolar lavage fluid from all patients and ventilator-associated pneumonia was confirmed by at least 104 colony forming units per mL of bronchoalveolar lavage fluid. The primary outcome was the distribution of antibiotic-free days in the 7 days following bronchoalveolar lavage. Data were analysed on an intention-to-treat basis, with an additional per-protocol analysis that excluded patients randomly assigned to the intervention group who defaulted to routine use of antibiotics because of failure to return an adequate biomarker result. An embedded process evaluation assessed factors influencing trial adoption, recruitment, and decision making. This study is registered with ISRCTN, ISRCTN65937227, and ClinicalTrials.gov, NCT01972425. FINDINGS: Between Nov 6, 2013, and Sept 13, 2016, 360 patients were screened for inclusion in the study. 146 patients were ineligible, leaving 214 who were recruited to the study. Four patients were excluded before randomisation, meaning that 210 patients were randomly assigned to biomarker-guided recommendation on antibiotics (n=104) or routine use of antibiotics (n=106). One patient in the biomarker-guided recommendation group was withdrawn by the clinical team before bronchoscopy and so was excluded from the intention-to-treat analysis. We found no significant difference in the primary outcome of the distribution of antibiotic-free days in the 7 days following bronchoalveolar lavage in the intention-to-treat analysis (p=0·58). Bronchoalveolar lavage was associated with a small and transient increase in oxygen requirements. Established prescribing practices, reluctance for bronchoalveolar lavage, and dependence on a chain of trial-related procedures emerged as factors that impaired trial processes. INTERPRETATION: Antibiotic use remains high in patients with suspected ventilator-associated pneumonia. Antibiotic stewardship was not improved by a rapid, highly sensitive rule-out test. Prescribing culture, rather than poor test performance, might explain this absence of effect. FUNDING: UK Department of Health and the Wellcome Trust.


Asunto(s)
Antibacterianos/uso terapéutico , Programas de Optimización del Uso de los Antimicrobianos/métodos , Lavado Broncoalveolar/métodos , Neumonía Asociada al Ventilador/tratamiento farmacológico , Biomarcadores/análisis , Líquido del Lavado Bronquioalveolar/microbiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neumonía Asociada al Ventilador/microbiología , Evaluación de Procesos, Atención de Salud , Medicina Estatal , Reino Unido
11.
Chest ; 142(6): 1425-1432, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22911225

RESUMEN

BACKGROUND: Ventilator-associated pneumonia (VAP) is characterized by neutrophils infiltrating the alveolar space. VAP is associated with high mortality, and accurate diagnosis remains difficult. We hypothesized that proteolytic enzymes from neutrophils would be significantly increased and locally produced inhibitors of human neutrophil elastase (HNE) would be decreased in BAL fluid (BALF) from patients with confirmed VAP. We postulated that in suspected VAP, neutrophil proteases in BALF may help identify "true" VAP. METHODS: BAL was performed in 55 patients with suspected VAP and in 18 control subjects. Isolation of a pathogen(s) at > 104 colony-forming units/mL of BALF dichotomized patients into VAP (n = 12) and non-VAP (n = 43) groups. Matrix metalloproteinases (MMPs), HNE, inhibitors of HNE, and tissue inhibitors of matrix metalloproteinases (TIMPs) were quantified. Plasminogen activator (PA) activity was estimated by sodium dodecyl sulfate polyacrylamide gel electrophoresis and zymography. RESULTS: Neutrophil-derived proteases HNE, MMP-8, and MMP-9 were significantly increased in cell-free BALF from patients with VAP as compared with those without VAP (median values: HNE, 2,708 ng/mL vs 294 ng/mL, P < .01; MMP-8, 184 ng/mL vs 5 ng/mL, P < .01; MMP-9, 310 ng/mL vs 11 ng/mL, P < .01). HNE activity was also significantly increased in VAP (0.45 vs 0.01 arbitrary units; P < .05). In contrast, no significant differences were observed for protease inhibitors, TIMPs, or PAs. HNE in BALF, at a cutoff of 670 ng/mL, identified VAP with a sensitivity of 93% and specificity of 79%. CONCLUSIONS: Neutrophil proteases are significantly elevated in the alveolar space in VAP and may contribute to pathogenesis. Neutrophil proteases appear to have potential in suspected VAP for distinguishing true cases from "non-VAP" cases.


Asunto(s)
Pulmón/enzimología , Neutrófilos/enzimología , Péptido Hidrolasas/metabolismo , Neumonía Asociada al Ventilador/diagnóstico , Neumonía Asociada al Ventilador/enzimología , Adulto , Anciano , Anciano de 80 o más Años , Líquido del Lavado Bronquioalveolar , Estudios de Casos y Controles , Movimiento Celular , Diagnóstico Diferencial , Femenino , Humanos , Pulmón/patología , Masculino , Metaloproteinasa 8 de la Matriz/metabolismo , Metaloproteinasa 9 de la Matriz/metabolismo , Persona de Mediana Edad , Neutrófilos/patología , Elastasa Pancreática/metabolismo , Neumonía Asociada al Ventilador/patología , Inhibidores Tisulares de Metaloproteinasas/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA