Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Int Orthop ; 47(11): 2655-2661, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37566227

RESUMEN

PURPOSE: Antibiotic loaded bone cement spacers provide high local antibiotic concentrations, preserve bone stock, and reduce soft tissue contractions. The objective of this in-vitro study was to compare antibiotic release from spacers, aiming to discover the most optimal preparation and identify modifiable factors that can further enhance antibiotic release. METHODS: Six distinct spacer preparation were created using three different bone cements and manual incorporation of antibiotics. During a six-week period, the release of antibiotics from each spacer was measured individually at ten predetermined time points using a chemiluminescent immunoassay. RESULTS: Manually adding 4 g of vancomycin to every 40 g of "Palacos R + G" yielded the most favorable release profile. Throughout all preparations, antibiotic release consistently and significantly decreased over the six-week period. When incorporating a higher concentration of vancomycin, a significantly higher cumulative release of vancomycin was observed, with varying effects on the release of gentamicin. The choice of bone cement had a significant impact on antibiotic release. CONCLUSION: To enhance antibiotic release from spacers, surgeons should manually incorporate high antibiotic concentrations into the most appropriate bone cement and keep the interim period as short as possible. Specifically, we suggest manual incorporation of 4 g of vancomycin to every 40 g of gentamicin premixed "Palacos R + G" to create bone cement spacers.


Asunto(s)
Artritis Infecciosa , Infecciones Relacionadas con Prótesis , Humanos , Antibacterianos/uso terapéutico , Vancomicina , Cementos para Huesos , Polimetil Metacrilato , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Gentamicinas
2.
BMC Musculoskelet Disord ; 23(1): 945, 2022 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-36309657

RESUMEN

BACKGROUND: Antibiotic-loaded polymethylmethacrylate (PMMA) bone cement spacers provide high local antibiotic concentrations and patient mobility during the interim period of two-stage revision for periprosthetic joint infection (PJI). This study compares mechanical characteristics of six dual antibiotic-loaded bone cement (dALBC) preparations made from three different PMMA bone cements. The study`s main objective was to determine the effect of time and antibiotic concentration on mechanical strength of dALBCs frequently used for spacer fabrication in the setting of two-stage revision for PJI. METHODS: A total of 84 dual antibiotic-loaded bone cement specimens made of either Copal spacem, Copal G + V or Palacos R + G were fabricated. Each specimen contained 0.5 g of gentamicin and either 2 g (low concentration) or 4 g (high concentration) of vancomycin powder per 40 g bone cement. The bending strength was determined at two different timepoints, 24 h and six weeks after spacer fabrication, using the four-point bending test. RESULTS: Preparations made from Copal G + V showed the highest bending strength after incubation for 24 h with a mean of 57.6 ± 1.2 MPa (low concentration) and 50.4 ± 4.4 MPa (high concentration). After incubation for six weeks the bending strength had decreased in all six preparations and Palacos R + G showed the highest bending strength in the high concentration group (39.4 ± 1.6 MPa). All low concentration preparations showed superior mechanical strength compared to their high concentration (4 g of vancomycin) counterpart. This difference was statistically significant for Copal spacem and Copal G + V (both p < 0.001), but not for Palacos R + G (p = 0.09). CONCLUSIONS: This study suggests that mechanical strength of antibiotic-loaded PMMA bone cement critically decreases even over the short time period of six weeks, which is the recommended interim period in the setting of two-stage revision. This potentially results in an increased risk for PMMA spacer fracture at the end of the interim period and especially in patients with prolonged interim periods. Finally, we conclude that intraoperative addition of 4 g of vancomycin powder per 40 g of gentamicin-premixed Palacos R + G (Group D) is mechanically the preparation of choice if a dual antibiotic-loaded bone cement spacer with high antibiotic concentrations and good stability is warranted. In any case the written and signed informed consent including the off-label use of custom-made antibiotic-loaded PMMA bone cement spacers must be obtained before surgery.


Asunto(s)
Artritis Infecciosa , Infecciones Relacionadas con Prótesis , Humanos , Polimetil Metacrilato , Vancomicina , Antibacterianos/uso terapéutico , Cementos para Huesos/efectos adversos , Reoperación , Polvos , Sulindac , Gentamicinas , Artritis Infecciosa/cirugía , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía
3.
Knee Surg Sports Traumatol Arthrosc ; 23(2): 443-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23334683

RESUMEN

PURPOSE: Subacromial decompression is the standard surgical treatment of subacromial impingement syndrome. Unsatisfactory results have been reported for concomitant lesions as well as inadequate diagnosis. We sought to determine the predictive value of the preoperative examination for the results of arthroscopic subacromial decompression in impingement syndrome. METHODS: Forty-nine shoulder joints in 47 patients receiving arthroscopic subacromial decompression were prospectively followed for a mean 3.7 ± 0.4 years. Prior to surgery, the impingement tests according to Neer, Hawkins-Kennedy (in the neutral as well as abducted position), and the Jobe test (empty can position) were evaluated as well as the presence of a painful arc. The association between the presence of these sings, success of the operation, and improvement in Constant scores as well as WORC indices was analysed. RESULTS: Pre- to postoperative improvement in Constant scores as well as WORC indices was greater in case of a positive test result for every test studied. With the numbers available, significant greater improvements in Constant scores were observed only for patients with a positive Hawkins-Kennedy sign in the neutral position, Neer and Jobe tests, compared to patients with negative signs, respectively. No significant differences were observed for the improvement in WORC indices. Patients with at least four positive tests out of the five studied had greater improvement in Constant scores than patients with three or less positive test results. Five patients went on to receive subsequent shoulder surgery. There was no association between the necessity for revision surgery and the presence or absence of impingement signs. CONCLUSION: The impingement tests according to Hawkins-Kennedy, Neer, and Jobe are valid predictors of outcome after subacromial decompression, as is the presence of multiple impingement tests. This study may aid in improving patient outcome and especially patient selection for subacromial decompression. LEVEL OF EVIDENCE: Prognostic, Level I.


Asunto(s)
Descompresión Quirúrgica , Evaluación del Resultado de la Atención al Paciente , Examen Físico/métodos , Síndrome de Abducción Dolorosa del Hombro/cirugía , Adulto , Anciano , Artroscopía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cuidados Preoperatorios , Pronóstico , Estudios Prospectivos , Síndrome de Abducción Dolorosa del Hombro/diagnóstico
4.
Hand Surg Rehabil ; 43(3): 101712, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38701947

RESUMEN

INTRODUCTION: Total joint replacement has become significantly more common as a treatment for advanced trapeziometacarpal joint osteoarthritis in recent years. The latest generation of prostheses with dual-mobility designs leads to very good functional results and low rates of loosening and dislocation in the short and medium term. Biomechanical studies showed that central placement and parallel alignment of the cup with respect to the proximal articular surface of the trapezium are crucial for both cup stability and prevention of dislocation. Despite correct positioning of the guidewire, incorrect placement or tilting of the inserted cup may occur, requiring immediate intraoperative revision. METHODS: The existing spherical and conical cup models in sizes 9 mm and 10 mm were transferred to a computer-aided design dataset. Depending on the intraoperative complication (tilting or incorrect placement), the revision options resulting from the various combinations of cup type and size were simulated and analyzed according to the resulting defect area and bony contact area. RESULTS: In well centered cups, a size 9 conical cup could be replaced by a size 9 spherical cup and still be fixed by press-fit. Conversely, a size 9 spherical cup could not be replaced by a size 9 conical cup, but only by a size 10 cup, of whatever shape. When a size 9 conical cup was tilted up to 20°, the best revision option was to resect the sclerotic margin and insert a size 10 conical cup deeper into the cancellous bone, to achieve the largest contact area with the surrounding bone. When a size 9 cup of whatever shape was poorly centered (misplaced with respect to the dorsopalmar or radioulnar line of the trapezium), placement should be corrected using a size 10 cup, combined with autologous bone grafting of the defect. Again, the size 10 conical cup showed the largest bony contact area. CONCLUSION: Our computer-based measurements suggested options for intraoperative cup revision depending on cup shape and size and on type of misalignment with resulting bone defects. These suggestions, however, need to be confirmed in anatomic specimens before introducing them into clinical practice.


Asunto(s)
Prótesis Articulares , Diseño de Prótesis , Reoperación , Humanos , Simulación por Computador , Diseño Asistido por Computadora , Articulaciones Carpometacarpianas/cirugía , Artroplastia de Reemplazo/instrumentación , Falla de Prótesis , Osteoartritis/cirugía , Hueso Trapecio/cirugía
5.
Handchir Mikrochir Plast Chir ; 56(3): 212-218, 2024 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-38861976

RESUMEN

BACKGROUND: The increasing use of thumb carpometacarpal joint prostheses for advanced CMC 1 (carpometacarpal) joint arthritis reflects the success of the latest prosthesis generations, which has been achieved through their improved functional outcomes and lower complication rates. Precise alignment of the prosthesis cup parallel to the proximal joint surface of the trapezium is essential for stability and the prevention of dislocation. This is a challenging surgical step, particularly for surgeons new to this technique. Despite adequate positioning of the guidewire, misplacements of the cup may occur, necessitating intraoperative revision. MATERIAL AND METHODS: This study examined the deviations in cup and guidewire positioning in thumb carpometacarpal joint prosthesis implantations by inexperienced and experienced surgeons through radiological analysis of 65 prostheses. RESULTS: Both inexperienced and experienced surgeons achieved precise guidewire positioning with mean deviations of<2.2°. Inexperienced surgeons showed significantly larger cup deviations in the dorsopalmar and lateral view (7.6±6.1° and 7.3±5.9°) compared with experienced surgeons (3.6±2.7° and 3.6±2.5°; p=0.012, p=0.017). The deviation of the cup position exhibited by inexperienced surgeons tends to be in the direction opposite to the initial guidewire position (p<0.0038). CONCLUSION: The results highlight the current challenges in cup positioning depending on a surgeon's level of experience, questioning the reliability of the current guidewire placement.


Asunto(s)
Articulaciones Carpometacarpianas , Pulgar , Articulaciones Carpometacarpianas/cirugía , Humanos , Pulgar/cirugía , Masculino , Femenino , Prótesis Articulares , Hilos Ortopédicos , Competencia Clínica , Persona de Mediana Edad , Anciano , Diseño de Prótesis , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Reoperación , Osteoartritis/cirugía
6.
Eur J Trauma Emerg Surg ; 49(1): 327-333, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36098797

RESUMEN

BACKGROUND: In orthopedic and trauma surgery, pulsatile lavage systems are used to clean soft tissue. This may be necessary in septic surgeries or in case of contaminated wounds after trauma. Positive features such as reduction of bacterial contamination and removal of foreign particles are counterbalanced by negative aspects such as bacterial seeding in deeper tissue layers, damage to various tissues and even cases of air embolism. PURPOSE: The aim of this prospective experimental in vitro study was to compare impact pressure and flow rate in three different pulsatile lavage systems and to determine, whether these parameters alter their ability to reach deeper soft tissue layers. METHODS: To test the penetration of soft tissue, the muscle tissue was flushed with contrast medium instead of saline fluid and afterwards scanned by computed tomography. RESULTS: Impact pressure and flow rate showed significant differences between the different systems. There were no significant differences between the three devices in terms of total penetration volume, but there were significant differences in penetration depth. CONCLUSION: In this study, we found that higher impact pressure leads to deeper penetration and therefore bacteria are likely to be transferred to deeper tissue layers.


Asunto(s)
Irrigación Terapéutica , Humanos , Irrigación Terapéutica/métodos , Estudios Prospectivos
7.
J Clin Med ; 12(4)2023 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-36835798

RESUMEN

The comprehensive "PJI-TNM classification" for the description of periprosthetic joint infections (PJI) was introduced in 2020. Its structure is based on the well-known oncological TNM classification to appreciate the complexity, severity, and diversity of PJIs. The main goal of this study is to implement the new PJI-TNM classification into the clinical setting to determine its therapeutic and prognostic value and suggest modifications to further improve the classification for clinical routine use. A retrospective cohort study was conducted at our institution between 2017 and 2020. A total of 80 consecutive patients treated with a two-stage revision for periprosthetic knee joint infection were included. We retrospectively assessed correlations between patients' preoperative PJI-TNM classification and their therapy and outcome and identified several statistically significant correlations for both classifications, the original and our modified version. We have demonstrated that both classifications provide reliable predictions already at the time of diagnosis regarding the invasiveness of surgery (duration of surgery, blood and bone loss during surgery), likelihood of reimplantation, and patient mortality during the first 12 months after diagnosis. Orthopedic surgeons can use the classification system preoperatively as an objective and comprehensive tool for therapeutic decisions and patient information (informed consent). In the future, comparisons between different treatment options for truly similar preoperative baseline situations can be obtained for the first time. Clinicians and researchers should be familiar with the new PJI-TNM classification and start implementing it into their routine practice. Our adjusted and simplified version ("PJI-pTNM") might be a more convenient alternative for the clinical setting.

9.
J Clin Med ; 10(22)2021 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-34830643

RESUMEN

The modern cementing technique in cemented arthroplasty is a highly standardized and, therefore, safe procedure. Nevertheless, aseptic loosening is still the main reason for revision after cemented total knee or cemented total hip arthroplasty. To investigate whether an additional carbon dioxide lavage after a high-pressure pulsatile saline lavage has a positive effect on the bone-cement interface or cement penetration, we set up a standardized laboratory experiment with 28 human femoral heads. After a standardized cleaning procedure, the test implants were cemented onto the cancellous bone. Subsequently, the maximum failure load of the bone-cement interface was determined using a material testing machine to pull off the implant, and the cement penetration was determined using computed tomography. Neither the maximum failure load nor cement penetration into the cancellous bone revealed significant differences between the groups. In conclusion, according to our experiments, the additive use of the carbon dioxide lavage after the high-pressure pulsatile lavage has no additional benefit for the cleaning of the cancellous bone and, therefore, cannot be recommended without restrictions.

10.
J Clin Med ; 11(1)2021 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-35011832

RESUMEN

In cemented joint arthroplasty, state-of-the-art cementing techniques include high-pressure pulsatile saline lavage prior to cementation. Even with its outstanding importance in cementation, there are surprisingly few studies regarding the physical parameters that define pulsatile lavage systems. To investigate the parameters of impact pressure, flow rate, frequency and the cleaning effect in cancellous bone, we established a standardized laboratory model. Standardized fat-filled carbon foam specimens representing human cancellous bone were cleaned with three different high-pressure pulsatile lavage systems. Via CT scans before and after cleaning, the cleaning effect was evaluated. All systems showed a cleaning depth of at least 3.0 mm and therefore can be generally recommended to clean cancellous bone in cemented joint arthroplasty. When comparing the three lavage systems, the study showed significant differences regarding cleaning depths and volume, with one system being superior to its peer systems. Regarding the physical parameters, high impact pressure in combination with high flow rate and longer distance to the flushed object seems to be the best combination to improve the cleaning of cancellous bone and therefore increase the chances of a deeper cement penetration that is required in cemented joint arthroplasty. In summary, this study provides the first standardized comparison of different lavage systems and thus gives initial guidance on how to optimally prepare cancellous bone for cemented joint arthroplasty.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA