Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 132(10): 102501, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38518336

RESUMEN

On the basis of revisions of some of the systematic errors, we reanalyzed the electron-antineutrino angular correlation (a coefficient) in free neutron decay inferred from the recoil energy spectrum of the protons which are detected in 4π by the aSPECT spectrometer. With a=-0.104 02(82) the new value differs only marginally from the one published in 2020. The experiment also has sensitivity to b, the Fierz interference term. From a correlated (b,a) fit to the proton recoil spectrum, we derive a limit of b=-0.0098(193) which translates into a somewhat improved 90% confidence interval region of -0.041≤b≤0.022 on this hypothetical term. Tighter constraints on b can be set from a combined [shown as superscript (c)] analysis of the PERKEO III (ß asymmetry) and aSPECT measurement which suggests a finite value of b with b^{(c)}=-0.0181±0.0065 deviating by 2.82σ from the standard model.

2.
Phys Rev Lett ; 118(21): 210401, 2017 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-28598671

RESUMEN

Using two-photon Bragg spectroscopy, we study the energy of particlelike excitations in a strongly interacting homogeneous Bose-Einstein condensate, and observe dramatic deviations from Bogoliubov theory. In particular, at large scattering length a the shift of the excitation resonance from the free-particle energy changes sign from positive to negative. For an excitation with wave number q, this sign change occurs at a≈4/(πq), in agreement with the Feynman energy relation and the static structure factor expressed in terms of the two-body contact. For a≳3/q we also see a breakdown of this theory, and better agreement with calculations based on the Wilson operator product expansion. Neither theory explains our observations across all interaction regimes, inviting further theoretical efforts.

3.
Phys Rev Lett ; 114(25): 255302, 2015 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-26197133

RESUMEN

We study the critical point for the emergence of coherence in a harmonically trapped two-dimensional Bose gas with tunable interactions. Over a wide range of interaction strengths we find excellent agreement with the classical-field predictions for the critical point of the Berezinskii-Kosterlitz-Thouless (BKT) superfluid transition. This allows us to quantitatively show, without any free parameters, that the interaction-driven BKT transition smoothly converges onto the purely quantum-statistical Bose-Einstein condensation transition in the limit of vanishing interactions.

4.
Hum Biol ; 85(1-3): 285-308, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24297230

RESUMEN

The presence of "pygmy" or pygmoid groups among New Guinea populations has been the object of scientific interest since the end of the nineteenth century. Morphological and molecular data are used here to study western New Guinea population variability, focusing in particular on two pygmoid groups living in the eastern fringe highlands of Papua: the Una and the Ketengban. Various kinds of anthropometric data are examined, as well as height, weight, and body mass index, to carry out comparisons with nearby ethnic groups living in the highland and lowland regions. The Ketengban data were also compared with other data recorded 20 years before. The results of previous research on the sequencing of the mitochondrial DNA hypervariable segment 1 region and nuclear DNA nonrecombining Y-chromosome polymorphisms are presented. Both morphological and molecular studies involve adult subjects of both genders, representative of the same ethnic groups and/or geographic regions. The pygmoid groups turn out to be significantly different from all other study groups, due to their small size, as confirmed by analysis of variance, although significant height and weight increments are observed with respect to those previously recorded. However, putative neutral genetic variation estimated from mitochondrial DNA and Y-chromosome markers support a recent shared common history between these pygmoid populations and the other central Papua groups (except for the Dani-Lani). These findings suggest that the short-stature phenotype is an independent secondary adaptation, possibly driven by an iodine-deficient environment, which leaves the potential for further investigations.


Asunto(s)
Antropometría , Nativos de Hawái y Otras Islas del Pacífico/genética , Adolescente , Adulto , Antropología Física , Evolución Biológica , Cromosomas Humanos Y , ADN Mitocondrial/genética , Evolución Molecular , Femenino , Variación Genética , Haplotipos , Humanos , Masculino , Persona de Mediana Edad , Nativos de Hawái y Otras Islas del Pacífico/etnología , Nueva Guinea/etnología
5.
Arch Orthop Trauma Surg ; 133(10): 1385-93, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23820852

RESUMEN

INTRODUCTION: Aim of this study was to evaluate outcomes of operative as compared to conserveative treatment for two-part humerus fractures at the surgical neck. METHODS: Data from a prospective multi-centre cohort study on four treatment options (conservative treatment and three implants, i.e. LPHP, PHILOS and PHN) for proximal humerus fractures were evaluated in this post hoc analysis. All patients with two-part fractures of the surgical neck (AO types A2, n = 54 and A3, n = 110) were identified and included for the analysis. All operatively treated patients were gathered and compared to those receiving conservative treatment. Primary outcome parameters were pain, range of motion and absolute and relative Constant scores at 3, 6 and 12 months following injury and coronal plane alignment at 12 months. RESULTS: Operative (n = 133) and non-operative (n = 31) groups were comparable with regard to all parameters assessed including mean age (62.9 vs. 65.6, P = 0.479), gender (27 vs. 29 % male, P = 0.826) and fracture distribution (65 vs. 77 % A3 type, P = 0.207). 26 of the 31 conservatively treated and 103 of the 133 operatively treated patients (84 and 77 %, respectively) were available for final follow-up. There was a continuous improvement for all outcome parameters in both treatment groups (P < 0.001). Operative treatment resulted in a more effective reduction of pain at 3 months (51 vs. 76 % reporting pain at fracture site, P = 0.03) and a reduction of coronal plane malalignment. Both range of motion and Constant scores were, however, comparable in both groups at all follow-up visits. Relative and absolute Constant scores were generally excellent at final follow-up (74 vs. 74, P = 0.528 and 89 vs. 91, P = 0.494, respectively). CONCLUSIONS: Both non-operative treatment and operative treatment using modern implants (LPHP, PHILOS and PHN) can be considered safe and effective treatment options for two-part fractures of the proximal humerus. Operative treatment may result in better range of motion and reduced pain in the early postoperative course of treatment.


Asunto(s)
Fijación Intramedular de Fracturas , Inmovilización , Fracturas del Hombro/terapia , Anciano , Terapia por Ejercicio , Femenino , Estudios de Seguimiento , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Indicadores de Salud , Humanos , Inmovilización/métodos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Recuperación de la Función , Fracturas del Hombro/cirugía , Lesiones del Hombro , Articulación del Hombro/fisiología , Articulación del Hombro/cirugía , Resultado del Tratamiento
6.
J Org Chem ; 76(11): 4506-13, 2011 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-21495695

RESUMEN

4-(4,6-Di[2,2,2-trifluoroethoxy]-1,3,5-triazin-2-yl)-4-methylomorpholinium tetrafluoroborate (DFET/NMM/BF(4)) was prepared and used as a reagent for coupling sterically hindered substrates. The formation of the appropriate triazine "superactive" ester in a reaction of DFET/NMM/BF(4) with carboxylic acids was confirmed. The efficiency of the reagent has been studied in the synthesis of Leu-enkephaline pentapeptide carried out on a Fmoc-RinkAmide-AM-PS resin, by systematically modifying the -Gly-Gly- fragment for N-methyl or α,α-disubstituted residues and compared with the efficiency of classic aminium salt 2-(1H-benzotriazole-1-yl)-1,1,3,3-tetramethyluronium tetrafluoroborate (TBTU) under a variety of reaction conditions. In syntheses of Aib-Aib (Aib: α-aminoisobutyric acid), MeVal-MeVal, and MeLeu-MeLeu, the considerably superior performance of enkephaline analogues was obtained for DFET/NMM/BF(4) relative to TBTU, regardless of reaction conditions. Analysis of the couplings involving triazine reagent suggests that factors controlling efficiency of coupling sterically hindered substrates are the structure of the leaving group permitting formation of the cyclic intermediate or cyclic transition state and the absence of strongly solvating solvents. It has to be considered as highly probable that the absence of strongly solvating milieu favors cyclic intermediates or the cyclic transition state. Arrangement of both components into the cyclic intermediate or cyclic transition state by accumulation of the geminal (vicinal) substituents effect (known as the Thorpe-Ingold effect) would compensate retardation of the coupling process caused by steric hindrance.


Asunto(s)
Boratos/química , Morfolinas/química , Triazinas/química , Alquilación , Aminoácidos/química , Indicadores y Reactivos/química , Nitrógeno/química , Oligopéptidos/síntesis química , Oligopéptidos/química
7.
J Trauma ; 69(6): 1501-6, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20526214

RESUMEN

BACKGROUND: Conventional percutaneous iliosacral screw placement in pelvic surgery is considered to be a highly demanding operative technique with a high rate of screw malpositions, which may be associated with the risk of neurologic damage or inefficient stability. In the conventional technique, the correct entry point for the screw and the small target corridor for the iliosacral screw may be difficult to visualize using an image intensifier. We tried to find out in this study whether the positioning of percutaneous screw implantations could be optimized by evaluating the rate and grade of malpositions and whether the needed revisions could be reduced by using computer navigation and three-dimensional (3D) image intensifier. METHODS: A group of 54 patients with 63 screws implanted using computer navigation was compared with 87 patients with 131 screws implanted using the conventional fluoroscopic technique. The exact screw position was controlled in a postoperative computed tomography scan, and the grade of malposition of every screw was investigated and compared. RESULTS: A complete intraosseous screw position was found in 42% of cases using the conventional technique and was significantly less compared with 81% using a 3D image intensifier in combination with a navigation system. Moreover, the revision rate of 1.6% was significantly less in the navigated group compared with 19% in the conventional group. CONCLUSIONS: The results indicate that 3D-computer navigation of the percutaneous iliosacral screw insertion can facilitate surgical performance in respect to reducing screw malposition and revision rates.


Asunto(s)
Tornillos Óseos , Imagenología Tridimensional , Articulación Sacroiliaca/diagnóstico por imagen , Articulación Sacroiliaca/cirugía , Tomografía Computarizada por Rayos X , Adulto , Hilos Ortopédicos , Femenino , Fluoroscopía , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Articulación Sacroiliaca/lesiones , Estadísticas no Paramétricas , Resultado del Tratamiento
8.
Unfallchirurg ; 113(1): 29-35, 2010 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-19862496

RESUMEN

BACKGROUND: The precision of sacroiliac screw placement can be improved with the use of navigation techniques. The purpose of this study was to evaluate the accuracy of 3D-navigated sacroiliac screw positioning in relation to the surgeon's experience with the navigation technique. PATIENTS AND METHODS: A consecutive series of 3D-navigated sacroiliac screw placements were prospectively evaluated between December 2005 and February 2008. Postoperatively the precision of screw placement was analyzed in relation to the surgeon's navigation experience with a CT-scan using the criteria of Smith. RESULTS: A total of 37 screws were implanted by 7 surgeons in 33 patients. In the group of surgeons with less experience in navigation techniques two cases of malpositioning led to revision of the screws. No screws which were implanted or assisted by surgeons experienced in navigation needed to be revised. There was no significant difference in the malposition rate. CONCLUSION: In the clinical setup a malpositioning of sacroiliac screws is possible even with the use of 3D navigation. One reason may be a low level of navigation experience of the surgeon in combination with low experience in the conventional technique. Therefore even in navigation-based placement of sacroiliac screws the malpositioning rate is dependent on the surgeon's experience with the navigation technique. The correct placement of the screws should be controlled intraoperatively using the 3D image intensifier.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Imagenología Tridimensional/métodos , Articulación Sacroiliaca/lesiones , Articulación Sacroiliaca/cirugía , Cirugía Asistida por Computador/instrumentación , Adolescente , Adulto , Anciano , Femenino , Fijación Interna de Fracturas/métodos , Humanos , Masculino , Persona de Mediana Edad , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
9.
Eur Arch Otorhinolaryngol ; 266(8): 1239-43, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19082836

RESUMEN

The aim of this study is to evaluate the haemostatic effect of carboxy-methylated cellulose (CMC) nasal packing following functional endoscopic sinus surgery (FESS). The design includes an investigator-initiated, randomized, single-blinded, controlled, prospective clinical study. A bilateral FESS procedure was performed on 41 patients. At the end of the operation, one side was randomly filled with CMC nasal packing, the other side remained without packing. The patients were blinded to the side of nasal packing and were postoperatively examined on the 1st day, after 2 and 4 weeks and the extent of the postoperative bleeding was quantified with a clinical grading system. Even though there were slightly more postoperative bleedings reported for the non-packed sides as compared to the CMC-packed sides, these differences were at no point statistically significant within the monitored postoperative period of 4 weeks. In the examined collective, the CMC packing investigated did not statistically prove to have an effect on bleeding control in this study design.


Asunto(s)
Carboximetilcelulosa de Sodio/uso terapéutico , Endoscopía/métodos , Pólipos Nasales/cirugía , Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Hemorragia Posoperatoria/terapia , Rinitis/cirugía , Sinusitis/cirugía , Administración Intranasal , Vendajes , Materiales Biocompatibles/uso terapéutico , Enfermedad Crónica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pólipos Nasales/complicaciones , Estudios Prospectivos , Rinitis/complicaciones , Sinusitis/complicaciones
10.
Rhinology ; 47(3): 237-41, 2009 09.
Artículo en Inglés | MEDLINE | ID: mdl-19839243

RESUMEN

Air-conditioning in the nasal passageways is one of the most important functions of the upper airways. By means of in-vivo-measurements and numerical simulation, the air-conditioning function of the nose has been extensively investigated. Less well known is the effect of nasal surgery on the nasal climate. The following study presents a summary of the effect of various rhino-surgical operations, i.e. turbinoplasty, septoplasty, septorhinoplasty, repair of septal perforations, functional and radical sinus surgery, on the air-conditioning function of the nose. Nasal and sinonasal interventions have been demonstrated to be associated with increased nasal heating and humidification when the mucosal lining is preserved. Radical interventions with reduction of turbinate tissue cause reduced nasal warming and moistening within the nasal airway, with increased risk of nasal dryness and crusting. Although the impact of the nasal cycle and the airflow distribution within the nasal cavity on nasal temperature and humidity distribution is not fully understood yet, too much widening of the nasal cavity by sinunasal interventions has carefully to be avoided.


Asunto(s)
Nariz/fisiopatología , Procedimientos Quirúrgicos Otorrinolaringológicos , Humanos , Humedad , Rinoplastia
11.
Rhinology ; 47(1): 36-40, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19382492

RESUMEN

BACKGROUND: Functional endoscopic sinus surgery (FESS) has become the treatment of choice for patients with medically resistant chronic rhinosinusitis (CRS and nasal polyposis). Nasal packing is usually placed after the surgery to minimize mucosal bleeding and support the wound healing process. Both the packing itself and its removal are often associated with pain and discomfort. OBJECTIVE: To evaluate the effect of carboxymethylcellulose (CMC) nasal packing on patient comfort following FESS. METHODS: Forty consecutive patients underwent bilateral FESS. One side of the nasal cavity was packed with CMC (mesh or gel) and the opposite side was not packed, the sides having been randomly selected. Postoperatively, patients were given visual analog scales to rate nasal airway obstruction and headache/pressure separately for the right and left sides. They also rated sleep disturbance and general well-being. RESULTS: No significant differences were found between the CMC-packed side and the unpacked side with regard to patient comfort. No significant differences were found between CMC mesh and CMC gel. CONCLUSION: Based on the presented data concerning patient comfort, CMC appears to be an ideal packing material following FESS. However, there is no other study revealing an identical study design focusing on other resorbable packing material. As a consequence, other available resorbable packing material should be investigated to find the ideal packing material following FESS, if packing is required.


Asunto(s)
Materiales Biocompatibles/uso terapéutico , Carboximetilcelulosa de Sodio/uso terapéutico , Endoscopía , Dolor Postoperatorio/prevención & control , Rinitis/cirugía , Sinusitis/cirugía , Adulto , Anciano , Método Doble Ciego , Femenino , Geles , Humanos , Masculino , Persona de Mediana Edad , Pólipos Nasales/patología , Pólipos Nasales/cirugía , Hemorragia Posoperatoria/prevención & control , Rinitis/patología , Sinusitis/patología , Mallas Quirúrgicas
12.
Rhinology ; 47(1): 89-92, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19382503

RESUMEN

OBJECTIVE: The surface temperature distribution within the nasal vestibule and the nasal cavity strongly depends on the exact intranasal detection site and point of time during the respiratory cycle. Therefore, conventional temperature measurements e.g. with thermocouples only provide selective measurements. The use of infrared thermography cameras could present a new contactless method with a high spatiotemporal resolution. The aim of the present study was to evaluate the use of infrared thermography camera systems for measurements of the nasal surface temperature during respiration. METHODS: The surface temperature profiles within the nasal vestibules of healthy volunteers were recorded with infrared thermography cameras during several breathing cycles. Two different types of infrared thermography standard systems were used. RESULTS: The recordings allowed a display of temperature alterations within the nasal vestibules in a high spatiotemporal resolution synchronous to the breathing cycle. During inspiration, the vestibular surface cooled down presenting a non-homogenous distribution (range, 24.7 to 30.2 degrees C). During expiration, the vestibular surface was warmed again with a non-homogenous distribution (range, 33.1 to 36.2 degrees C). The results of both camera systems were comparable. CONCLUSION: Infrared thermography cameras allow the exact mapping of nasal surface temperature within the nasal vestibules with a high spatiotemporal resolution without surface contact.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/instrumentación , Cavidad Nasal , Fotograbar/instrumentación , Respiración , Termogénesis/fisiología , Termografía/métodos , Estudios de Factibilidad , Humanos , Reproducibilidad de los Resultados , Termografía/instrumentación
13.
Water Sci Technol ; 58(7): 1483-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18957763

RESUMEN

A comparison of stillage treatment options for large-scale bioethanol plants was based on the data of an existing plant producing approximately 200,000 t/yr of bioethanol and 1,400,000 t/yr of stillage. Animal feed production--the state-of-the-art technology at the plant--was compared to anaerobic digestion. The latter was simulated in two different scenarios: digestion in small-scale biogas plants in the surrounding area versus digestion in a large-scale biogas plant at the bioethanol production site. Emphasis was placed on a holistic simulation balancing chemical parameters and calculating logistic algorithms to compare the efficiency of the stillage treatment solutions. For central anaerobic digestion different digestate handling solutions were considered because of the large amount of digestate. For land application a minimum of 36,000 ha of available agricultural area would be needed and 600,000 m(3) of storage volume. Secondly membrane purification of the digestate was investigated consisting of decanter, microfiltration, and reverse osmosis. As a third option aerobic wastewater treatment of the digestate was discussed. The final outcome was an economic evaluation of the three mentioned stillage treatment options, as a guide to stillage management for operators of large-scale bioethanol plants.


Asunto(s)
Alimentación Animal , Reactores Biológicos , Etanol/metabolismo , Algoritmos , Anaerobiosis , Fuentes Generadoras de Energía/economía
14.
Acta Chir Orthop Traumatol Cech ; 75(6): 413-21, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19149997

RESUMEN

Proximal humerus fractures represent an increasing challenge for the health system due to epidemiological changes. As estimated by a Finnish study group the number of fractures may triple by the year 2030. The majority of patients with these fractures are older than 60 years and in this population most of the proximal humerus fractures have been related to osteoporosis. Nondisplaced fractures and fractures with minimal displacement and adequate stability are usually successfully treated non-operatively. The main challenge in the operative treatment of displaced and unstable proximal humerus fractures is to achieve effective stabilization of an adequately reduced fracture to maximize the functional patient outcome. Especially in osteoporotic bone and comminuted fractures operative stabilization is challenging and the management of displaced and unstable fractures remains controversial. The most important factor for favourable results in the treatment of complex three-part or four-part humerus fractures is anatomic reduction. Minimal exposure, high primary stability, and load transfer through the implant are important for avoiding complications such as secondary dislocation, osteonecrosis, and stiffness. Recently invented implants with angular stability provide better biomechanical properties and enhanced anchorage especially in the osteoporotic bone. These implants therefore have a potential for achieving better results in the treatment of these complex injuries.


Asunto(s)
Fracturas del Hombro/cirugía , Artroplastia , Artroplastia de Reemplazo , Clavos Ortopédicos , Fijación Interna de Fracturas , Fijación Intramedular de Fracturas , Humanos , Articulación del Hombro/cirugía
15.
Chirurg ; 78(2): 161-71; quiz 172-3, 2007 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-17262183

RESUMEN

The treatment of proximal extra-articular tibial fractures can be challenging due to extensive soft tissue damage and the special biomechanical conditions in the proximal tibial region. Different osteosynthetic procedures are available for operative stabilization. Treatment with an external fixator is recommended in particular as an emergency and short-term implant for temporary stabilization of fractures with extensive soft tissue damage. Intramedullary nailing represents a minimally invasive but technically demanding procedure to stabilize proximal tibial fractures. Angularly stable implant systems such as the so-called less invasive stabilization system fulfill the demands of fast implantation, soft tissue protection, and high biomechanical stability. The rate of malalignments and instabilities with delayed healing can be reduced using these new implants.


Asunto(s)
Fracturas de la Tibia/cirugía , Accidentes por Caídas , Accidentes de Tránsito , Traumatismos en Atletas , Fenómenos Biomecánicos , Placas Óseas , Fijadores Externos , Fijación Interna de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Radiografía , Fracturas de la Tibia/clasificación , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/etiología
16.
Acta Chir Orthop Traumatol Cech ; 74(6): 410-5, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18198093

RESUMEN

It is well known that proximal humerus fractures are among the three most frequent fracture types. Epidemiological invetsigations show that in people elder than 60 years the fracture of the proximal humerus is more frequent than fractures of the hip region (17). Over the last decades several techniques have been applied for treatment of proximal humerus fractures. Widely accepted is the initiation of a conservative treatment regimen for undisplaced fractures, however, the standard treatment for displaced fractures, especially three and four part fractures, is still the center of scientific debate. Many different implants have been tested and investigated, thus demonstrating lack of sufficient results. Over the last years the development of angle stable, locking implants started and clinical studies demonstrated encouraging results. In our clinic the locking proximal humerus plate and the PHILOS plate advanced to the implant of choice for treatment of displaced proximal humerus fractures. There are still cases of implant failure and humerus head necrosis, but most of these complications were caused by the fracture type and not an implant specific problem. However the overall results with these new implants are encouraging. Key words: locking plates, proximal humerus fracture, humerus, humerus fracture, PHILOS, PHP.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas del Hombro/cirugía , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Radiografía , Fracturas del Hombro/diagnóstico por imagen
17.
Urologe A ; 40(2): 133-6, 2001 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-11315588

RESUMEN

Increased urinary outputs are common after release of bilateral ureteral or subvesical obstruction. However, polyuria is rare following unilateral obstruction. We report a case of excessive postobstructive diuresis of more than 58,000 ml per day (204 l in 10 days) after release of a left ureteral obstruction in a 56-year-old female, being the highest amounts reported in the literature. Polyuria was derived from the obstructed as well as from the normal contralateral kidney. The involved pathomechanism is complex and not completely understood. Treatment includes careful monitoring of the patient and replacement of fluid and electrolytes. In our case complete recovery of kidney function was observed after several days.


Asunto(s)
Hidronefrosis/cirugía , Poliuria/etiología , Complicaciones Posoperatorias/etiología , Obstrucción Ureteral/cirugía , Femenino , Humanos , Hidronefrosis/diagnóstico por imagen , Hidronefrosis/etiología , Metástasis Linfática , Persona de Mediana Edad , Neoplasias Ováricas/complicaciones , Neoplasias Ováricas/diagnóstico por imagen , Neoplasias Ováricas/cirugía , Poliuria/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Reoperación , Tomografía Computarizada por Rayos X , Obstrucción Ureteral/diagnóstico por imagen , Obstrucción Ureteral/etiología , Urografía
18.
Urologe A ; 23(5): 244-50, 1984 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-6150570

RESUMEN

The use of microsurgical techniques offers operative perspectives also in urology. Microsurgery is indicated for reconstructive vascular surgery in the kidneys, in cases of erectile impotence, and in high maldescended testicles, for recanalisation of the vas deferens and in early childhood for plasty surgery of malformations of the upper urinary tract and such of the male genitals. Certain indications are presented under reference to own clinical experiences.


Asunto(s)
Microcirugia/métodos , Enfermedades Urológicas/cirugía , Adulto , Aneurisma/cirugía , Arterias/cirugía , Niño , Preescolar , Criptorquidismo/cirugía , Humanos , Hipospadias/cirugía , Lactante , Recién Nacido , Neoplasias Renales/cirugía , Trasplante de Riñón , Masculino , Arteria Renal/cirugía , Obstrucción de la Arteria Renal/cirugía , Técnicas de Sutura , Testículo/irrigación sanguínea , Testículo/trasplante , Uréter/cirugía , Obstrucción Ureteral/cirugía , Conducto Deferente/cirugía
19.
Urologe A ; 18(5): 289-93, 1979 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-494455

RESUMEN

Highenergy shock waves can desintegrate human calculi of the kidney into fine fragments without direct contact. A closed reflector system which allows sterile contact with the exposed kidney is presented.


Asunto(s)
Cálculos Renales/terapia , Animales , Perros , Humanos , Métodos , Presión , Ratas
20.
Urologe A ; 25(4): 188-92, 1986 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-3765221

RESUMEN

The recently developed equipment for extracorporeal piezoelectric lithotripsy (EPL) represents an improvement concerning the shock-wave-induced disintegration of urinary calculi. While the usual spark gap transmitter needs a focusing reflector, the piezoelectric lithotriptor is based on a self-focusing spherical bowl transmitter. The stone is detected exclusively by ultrasound. For this purpose, an integrated sector scanner is used as well as the high-energy sound transmitter itself. With the piezoelectrically generated high-energy sound pulses we have succeeded in completely disintegrating implanted stones in the renal pelvis of dogs without injuring the morphology or function of the exposed kidneys.


Asunto(s)
Cálculos Renales/terapia , Litotricia/instrumentación , Animales , Perros , Riñón/patología , Cálculos Renales/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA