Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ann Noninvasive Electrocardiol ; 26(2): e12812, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33124739

RESUMEN

BACKGROUND: Eleven criteria correlating electrocardiogram (ECG) findings with reduced left ventricular ejection fraction (LVEF) have been previously published. These have not been compared head-to-head in a single study. We studied their value as a screening test to identify patients with reduced LVEF estimated by cardiac magnetic resonance (CMR) imaging. METHODS: ECGs and CMR from 548 patients (age 61 + 11 years, 79% male) with previous myocardial infarction (MI), from the DETERMINE and PRE-DETERMINE studies, were analyzed. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of each criterion for identifying patients with LVEF ≤ 30% and ≤ 40% were studied. A useful screening test should have high sensitivity and NPV. RESULTS: Mean LVEF was 40% (SD = 11%); 264 patients (48.2%) had LVEF ≤ 40%, and 96 patients (17.5%) had LVEF ≤ 30%. Six of 11 criteria were associated with a significant lower LVEF, but had poor sensitivity to identify LVEF ≤ 30% (range 2.1%-55.2%) or LVEF ≤ 40% (1.1%-51.1%); NPVs were good for LVEF ≤ 30% (range 82.8%-85.9%) but not for LVEF ≤ 40% (range 52.1%-60.6%). Goldberger's third criterion (RV4/SV4 < 1) and combinations of maximal QRS duration > 124 ms + either Goldberger's third criterion or Goldberger's first criterion (SV1 or SV2 + RV5 or RV6 ≥ 3.5 mV) had high specificity (95.4%-100%) for LVEF ≤ 40%, although seen in only 48 (8.8%) patients; predictive values were similar on subgroup analysis. CONCLUSIONS: None of the ECG criteria qualified as a good screening test. Three criteria had high specificity for LVEF ≤ 40%, although seen in < 9% of patients. Whether other ECG criteria can better identify LV dysfunction remains to be determined.


Asunto(s)
Electrocardiografía/métodos , Infarto del Miocardio/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Eur Heart J ; 39(31): 2888-2895, 2018 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-29860404

RESUMEN

Aims: There is an almost endless controversy regarding the choice of the QT correction formula to be used in electrocardiograms (ECG) in neonates for screening for long QT syndrome (LQTS). We compared the performance of four commonly used formulae and a new formula derived from neonates. Methods and results: From a cohort of 44 596 healthy neonates prospectively studied in Italy between 2001 and 2006, 5000 ECGs including 17 with LQTS-causing mutation identified by genotyping were studied using four QT correction formulae [Bazett's (QTcB), Fridericia's (QTcF), Framingham (QTcL), and Hodges (QTcH)]. A neonate-specific exponential correction (QTcNeo) was derived using 2500 randomly selected ECGs and validated for accuracy in the remaining 2500 ECGs. Digital ECGs were recorded between the 15th and 25th day of life; QT interval was measured manually in leads II, V5, and V6. To assess the ability to provide heart rate (HR) independent QT correction, regression analysis of the QTc-HR plots for all 5000 ECGs with each correction formula was done. QTcB provided the most HR independent correction with a slope closest to zero (slope +0.086 ms/b.p.m.) followed by QTcF (slope -0.308 ms/b.p.m.), QTcL (slope -0.364 ms/b.p.m.), and QTcH (slope +0.962 ms/b.p.m.). The QTc-HR slope of QTcNeo (QT/RR0.467) was similar to QTcB. The ability to correctly identify neonates with LQTS was best with QTcB, QTcF, and QTcNeo (comparable areas under the receiver operating characteristic curves) with positive predictive value of 39-40% and sensitivity of 100%. Cut-off values were 460 ms for QTcB, 394 ms for QTcF, and 446 ms for QTcNeo. Conclusions: The Bazett's correction provides an effective HR independent QT correction and also accurately identifies the neonates affected by LQTS. It can be used with confidence in neonates, although other methods could also be used with appropriate cut-offs.


Asunto(s)
Electrocardiografía/métodos , Electrocardiografía/estadística & datos numéricos , Síndrome de QT Prolongado/diagnóstico , Tamizaje Neonatal/métodos , Interpretación Estadística de Datos , Femenino , Frecuencia Cardíaca , Humanos , Recién Nacido , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Análisis de Regresión
3.
J Electrocardiol ; 51(6): 991-995, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30497762

RESUMEN

INTRODUCTION: There are few published studies on reference ranges of ECG parameters in children; some ethnic differences have been described. METHODS: We studied digital 12­lead ECGs (1000 samples/s) from 906 healthy rural Indian children (467 boys: 439 girls) aged 5-15 years. PR, QRS, and QT were measured using superimposed median beat. Age-wise normal limits (median, 2nd and 98th percentile) were defined. RESULTS: Heart rate decreased while PR interval and QRS duration increased with age. QTcB interval remained unchanged from 5 to 12 years and decreased thereafter due to QTcB shortening in boys but not in girls. "Juvenile T wave pattern" was seen in 95% of children aged 5-8 years in lead V1 and 55-60% in V2, V3; it decreased with age. RV dominance (R/S > 1) in lead V1 was seen in 13% at 5 years, 1% at 10 years and none at 14 years. CONCLUSION: Reference ranges in Indian children are similar to those in other ethnic groups.


Asunto(s)
Fenómenos Fisiológicos Cardiovasculares , Ecocardiografía , Electrocardiografía , Adolescente , Niño , Preescolar , Femenino , Humanos , India , Masculino , Valores de Referencia
4.
J Electrocardiol ; 49(5): 714-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27395365

RESUMEN

BACKGROUND: The spatial QRS-T angle is ideally derived from orthogonal leads. We compared the spatial QRS-T angle derived from orthogonal leads reconstructed from digital 12-lead ECGs and from digital Holter ECGs recorded with the Mason-Likar (M-L) electrode positions. METHODS AND RESULTS: Orthogonal leads were constructed by the inverse Dower method and used to calculate spatial QRS-T angle by (1) a vector method and (2) a net amplitude method, in 100 volunteers. Spatial QRS-T angles from standard and M-L ECGs differed significantly (57°±18° vs 48°±20° respectively using net amplitude method and 53°±28° vs 48°±23° respectively by vector method; p<0.001). Difference in amplitudes in leads V4-V6 was also observed between Holter and standard ECGs, probably due to a difference in electrical potential at the central terminal. CONCLUSION: Mean spatial QRS-T angles derived from standard and M-L lead systems differed by 5°-9°. Though statistically significant, these differences may not be clinically significant.


Asunto(s)
Diagnóstico por Computador/normas , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Electrodos , Procesamiento de Señales Asistido por Computador/instrumentación , Diagnóstico por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Br J Clin Pharmacol ; 77(3): 522-31, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23819796

RESUMEN

AIM: To study the differences in QTc interval on ECG in response to a single oral dose of rac-sotalol in men and women. METHODS: Continuous 12-lead ECGs were recorded in 28 men and 11 women on a separate baseline day and following a single oral dose of 160 mg rac-sotalol on the following day. ECGs were extracted at prespecified time points and upsampled to 1000 Hz and analyzed manually in a central ECG laboratory on the superimposed median beat. Concentration-QTc analyses were performed using a linear mixed effects model. RESULTS: Rac-sotalol produced a significant reduction in heart rate in men and in women. An individual correction method (QTc I) most effectively removed the heart rate dependency of the QTc interval. Mean QTc I was 10 to 15 ms longer in women at all time points on the baseline day. Rac-sotalol significantly prolonged QTc I in both genders. The largest mean change in QTc I (ΔQTc I) was greater in females (68 ms (95% confidence interval (CI) 59, 76 ms) vs. 27 ms (95% CI 22, 32 ms) in males). Peak rac-sotalol plasma concentration was higher in women than in men (mean Cmax 1.8 µg ml(-1) (range 1.1-2.8) vs. 1.4 µg ml(-1) (range 0.9-1.9), P = 0.0009). The slope of the concentration-ΔQTc I relationship was steeper in women (30 ms per µg ml(-1) vs. 23 ms per µg ml(-1) in men; P = 0.0135). CONCLUSIONS: The study provides evidence for a greater intrinsic sensitivity to rac-sotalol in women than in men for drug-induced delay in cardiac repolarization.


Asunto(s)
Antagonistas Adrenérgicos beta/efectos adversos , Antiarrítmicos/efectos adversos , Frecuencia Cardíaca/efectos de los fármacos , Síndrome de QT Prolongado/inducido químicamente , Sotalol/efectos adversos , Administración Oral , Antagonistas Adrenérgicos beta/administración & dosificación , Antagonistas Adrenérgicos beta/farmacocinética , Antiarrítmicos/administración & dosificación , Antiarrítmicos/farmacocinética , Esquema de Medicación , Electrocardiografía , Femenino , Humanos , Modelos Lineales , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/fisiopatología , Masculino , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Sotalol/administración & dosificación , Sotalol/farmacocinética
6.
Am J Ther ; 21(6): 512-22, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24451296

RESUMEN

Assessments of cardiac and cardiovascular toxicity are prominent components of drug safety endeavors during drug development and clinical practice. Oncologic drugs bring several challenges to both domains. First, during drug development, it is necessary to adapt the ICH E14 "Thorough QT/QTc Study" because the cytotoxic nature of many oncologics precludes their being administered to healthy individuals. Second, appropriate benefit-risk assessments must be made by regulators: given the benefit these drugs provide in life-threatening illnesses, a greater degree of risk may be acceptable when granting marketing authorization than for drugs for less severe indications. Third, considerable clinical consideration is needed for patients who are receiving and have finished receiving pharmacotherapy. Paradoxically, although such therapy has proved very successful in many cases, with disease states going into remission and patients living for many years after cessation of treatment, cardiotoxicities can manifest themselves relatively soon or up to a decade later. Oncologic drugs have been associated with various off-target cardiovascular responses, including cardiomyopathy leading to heart failure, cardiac dysrhythmias, thromboembolic events, and hypertension. Follow-up attention and care are, therefore, critical. This article reviews the process of benefit-risk estimation, provides an overview of nonclinical and preapproval clinical assessment of cardiovascular safety of oncology drugs, and discusses strategies for monitoring and management of patients receiving drugs with known cardiotoxicity risk. These measures include cardiac function monitoring, limitation of chemotherapy dose, use of anthracycline analogs and cardioprotectants, and early detection of myocardial cell injury using biomarkers.


Asunto(s)
Antineoplásicos/uso terapéutico , Cardiotoxicidad/prevención & control , Diseño de Fármacos , Animales , Antineoplásicos/efectos adversos , Cardiotoxicidad/etiología , Cardiotoxicidad/fisiopatología , Monitoreo de Drogas/métodos , Humanos , Neoplasias/tratamiento farmacológico , Medición de Riesgo/métodos , Factores de Tiempo
7.
Ann Noninvasive Electrocardiol ; 19(2): 182-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24521536

RESUMEN

BACKGROUND: Two methods of estimating reader variability (RV) in QT measurements between 12 readers were compared. METHODS: Using data from 500 electrocardiograms (ECGs) analyzed twice by 12 readers, we bootstrapped 1000 datasets each for both methods. In grouped analysis design (GAD), the same 40 ECGs were read twice by all readers. In pairwise analysis design (PAD), 40 ECGs analyzed by each reader in a clinical trial were reanalyzed by the same reader (intra-RV) and also by another reader (inter-RV); thus, variability between each pair of readers was estimated using different ECGs. RESULTS: Inter-RV (mean [95% CI]) between pairs of readers by GAD and PAD was 3.9 ms (2.1-5.5 ms) and 4.1 ms (2.6-5.4 ms), respectively, using ANOVA, 0 ms (-0.0 to 0.4 ms), and 0 ms (-0.7 to 0.6 ms), respectively, by actual difference between readers and 7.7 ms (6.2-9.8 ms) and 7.7 ms (6.6-9.1 ms), respectively, by absolute difference between readers. Intra-RV too was comparable. CONCLUSIONS: RV estimates by the grouped- and pairwise analysis designs are comparable.


Asunto(s)
Electrocardiografía/métodos , Electrocardiografía/estadística & datos numéricos , Frecuencia Cardíaca/fisiología , Variaciones Dependientes del Observador , Proyectos de Investigación , Análisis de Varianza , Humanos
8.
J Electrocardiol ; 47(2): 155-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24388488

RESUMEN

Lead II is commonly used to study drug-induced QT prolongation. Whether other ECG leads too show comparable QT prolongation is not known. We studied moxifloxacin-induced QT prolongation in a thorough QT study in healthy subjects (54 males, 43 females). Placebo-subtracted change from baseline in QTc corrected by Fridericia's method (ΔΔQTcF) at 1, 1.5, 2 and 4 hours after moxifloxacin was studied in all 12 leads. Unacceptably wide 90% confidence interval (CI) for ΔΔQTcF was seen in three leads; these leads also had maximum ECGs with flat T waves (60% in aVL, 45% in lead III and 42% in V1). After excluding ECGs with flat T waves, 90% lower CI of ΔΔQTcF was ≥ 5 ms in all leads except leads III, aVL and V1 in men. The 90% lower CI exceeded 5 ms in these leads in women despite wide 90% CIs because of greater mean ΔΔQTcF. Leads III, aVL and V1 should be avoided when measuring QT interval in thorough QT studies.


Asunto(s)
Antibacterianos/efectos adversos , Electrocardiografía/métodos , Fluoroquinolonas/efectos adversos , Síndrome de QT Prolongado/inducido químicamente , Síndrome de QT Prolongado/diagnóstico , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Moxifloxacino , Placebos , Sensibilidad y Especificidad
9.
J Electrocardiol ; 47(2): 140-3, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24209499

RESUMEN

Reader variability (RV) results from measurement differences or variability in lead used for QT measurements; the latter is not reflected in conventional methods for estimating RV. Mean and SD of QT intervals in 12 leads of 100 ECGs measured twice were used to simulate data sets with inter-RV of 5, 10, 15, 20, and 25 ms and intra-RV of 3, 6, 9, 12, and 15 ms. Six hundred twenty-five data sets were simulated such that different leads were used in Read1 and Read2 in 0, 10%, 20%, 30%, 40% of ECGs by 25 readers. RV was estimated using ANOVA interaction models: three-way model using Reader, ECG and lead as factors, and 2-way model using reader and ECG as factors. Estimates from three-way model accurately matched inter- and intra-RV that were introduced during simulation regardless of percent of ECGs with lead selection variability. The two-way model provides identical estimates when both reads are in same leads, but higher, more realistically estimates when measurements are made in different leads.


Asunto(s)
Arritmias Cardíacas/inducido químicamente , Arritmias Cardíacas/diagnóstico , Electrocardiografía/instrumentación , Modelos Estadísticos , Análisis de Varianza , Simulación por Computador , Humanos , Variaciones Dependientes del Observador
10.
Int J Neuropsychopharmacol ; 15(10): 1535-40, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22313550

RESUMEN

We compared heart rate-corrected QT interval (QTc) and its within- and between-subject variability, in ECGs recorded several days apart for 207 patients with schizophrenia (age range 19-60 yr) with age- and gender-matched healthy controls. Patients had higher heart rates (mean±s.d.) than controls [75±15 beats per minute (bpm) vs. 63±10 bpm; p<0.0001]. QTc by Bazett's formula (QTcB) overestimated QTc interval at high heart rates; consequently QTcB was longer in patients (412±24 ms) than in controls (404±24 ms; p=0.0003). QTc by Fridericia's method (QTcF), which was not influenced by heart rate, was comparable (398±22 ms in patients vs. 401±19 ms in controls; p=0.17). Between-subject variability in QTcF was similar in patients (17 ms) and controls (16.2 ms) but within-subject variability was larger (13.1 ms vs. 10 ms, respectively). Thus, a larger sample size is required when thorough QTc studies with a cross-over design are performed in patients with schizophrenia than in healthy subjects; sample size is not increased for studies with a parallel design. Last, QTcF is preferred over QTcB in schizophrenia patients with higher heart rates.


Asunto(s)
Electrocardiografía/métodos , Frecuencia Cardíaca/fisiología , Esquizofrenia/fisiopatología , Adulto , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esquizofrenia/epidemiología , Adulto Joven
11.
Indian J Med Res ; 135: 322-30, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22561618

RESUMEN

BACKGROUND & OBJECTIVES: Morphological abnormalities in 12-lead electrocardiograms (ECGs) are seen in subgroups of healthy individuals like athletes and air-force personnel. As these populations may not truly represent healthy individuals, we assessed morphological abnormalities in ECG in healthy volunteers participating in phase I studies, who are screened to exclude associated conditions. METHODS: ECGs from 62 phase I studies analyzed in a central ECG laboratory were pooled. A single drug-free baseline ECG from each subject was reviewed by experienced cardiologists. ECG intervals were measured on five consecutive beats and morphological abnormalities identified using standard guidelines. RESULTS: Morphological abnormalities were detected in 25.5 per cent of 3978 healthy volunteers (2495 males, 1483 females; aged 18-76 yr); the presence was higher in males (29.3% vs. 19.2% in females; P<0.001). Rhythm abnormalities were the commonest (11.5%) followed by conduction abnormalities (5.9%), axis deviation (4%), ST-T wave changes (3.1%) and chamber enlargement (1.4%). Incomplete right bundle branch block (RBBB), short PR interval and right ventricular hypertrophy were common in young subjects (<20 yr) while atrial fibrillation, first degree atrioventricular block, complete RBBB and left anterior fascicular block were more prevalent in elderly subjects (>65 yr). Prolonged PR interval, RBBB and intraventricular conduction defects were more common in males while sinus tachycardia, short PR interval and non-specific T wave changes were more frequent in females. INTERPRETATION & CONCLUSIONS: Morphological abnormalities in ECG are commonly seen in healthy volunteers participating in phase I studies; and vary with age and gender. Further studies are required to determine whether these abnormalities persist or if some of these disappear on follow up.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía/métodos , Adulto , Factores de Edad , Anciano , Arritmias Cardíacas/epidemiología , Femenino , Humanos , India/epidemiología , Masculino , Persona de Mediana Edad , Factores Sexuales
12.
J Electrocardiol ; 45(3): 225-30, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22364647

RESUMEN

INTRODUCTION: We postulated that it may be easier to identify earliest Q onset and latest T offset when the median beats from 12 leads are separated vertically by 5 to 10 mm (ungrouped superimposed median beat [SMB] method) rather than when their baselines closely (but rarely perfectly) overlap (grouped SMB method). METHODS: Three readers manually adjudicated annotations placed by an automated algorithm, using grouped (gSMB) and ungrouped (uSMB) methods in 2658 electrocardiograms (ECGs) recorded in 38 subjects in a crossover design thorough QT study at predose and 6 time points postdosing with placebo or moxifloxacin. RESULTS: Placebo-subtracted, moxifloxacin-induced QTcF prolongation was comparable with both methods. Maximum QTcF prolongation was seen at 2 hours--10.5 milliseconds (90% confidence interval, 7.9-13.1 milliseconds) with gSMB and 12.9 milliseconds (90% confidence interval, 9.9-15.8 milliseconds) by uSMB. Both methods showed good agreement; mean QT was 4 milliseconds greater by uSMB. Interreader variability of absolute differences in QT measurements was 1 millisecond lower with the uSMB method (6.8 ± 5.7 milliseconds by gSMB and 5.9 ± 4.5 milliseconds by uSMB). CONCLUSION: Mean QT was 4 milliseconds longer, and interreader variability, 1 millisecond lower with uSMB. Otherwise, both methods were comparable and detected the moxifloxacin effect.


Asunto(s)
Algoritmos , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Frecuencia Cardíaca , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/fisiopatología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Indian Heart J ; 64(6): 535-40, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23253403

RESUMEN

INTRODUCTION: Conventionally, QT interval is measured in lead II. There are no data to select an alternative lead for QT measurement when it cannot be measured in Lead II for any reason. METHODS AND RESULTS: We retrospectively analyzed ECGs from 1906 healthy volunteers from 41 phase I studies. QT interval was measured on the median beat in all 12 leads. The mean difference in QT interval between lead aVR and in Lead II was the least, followed by aVF, V5, V6 and V4; lead aVL had maximum difference. The T wave was flat (<0.1 mV) in Lead II in 6.9% of ECGs; it was also flat in 20% of these ECGs (1.4% of all ECGs) in Leads aVR, aVF and V5. CONCLUSIONS: When QT interval cannot be measured in Lead II, the best alternative leads are aVR, aVF, V5, V6 and V4 in that sequence. It differs maximally from that in Lead II in Lead aVL.


Asunto(s)
Electrocardiografía/métodos , Sistema de Conducción Cardíaco/fisiología , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Síndrome de QT Prolongado/fisiopatología , Masculino , Valores de Referencia , Estudios Retrospectivos
14.
J Assoc Physicians India ; 60: 56-61, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22715547

RESUMEN

BACKGROUND: Better control of diabetes mellitus reduces microvascular complications, but has limited effect on macrovascular complications including cardiovascular mortality. A spate of controversial reports has shown that some new oral antidiabetic drugs may paradoxically increase cardiovascular events and mortality. We review here published data on cardiac safety of currently available oral antidiabetic drugs. METHODS: Literature search was performed for "cardiovascular risk" and "antidiabetic drugs" or individual oral antidiabetic drugs. RESULTS: Some sulfonylureas increase cardiovascular risk presumably by preventing protective ischemic cardiac preconditioning. Rosiglitazone increases risk of myocardial infarction and death possibly by increasing serum triglycerides and LDL-cholesterol levels. Muraglitazar increased risk of cardiovascular death, myocardial infarction, or stroke due to as yet unidentified reasons. Only insulin sensitizing drugs like metformin and pioglitazone have been consistently shown to reduce cardiovascular risk. Beneficial effects of tight glucose control with insulin or insulin secretagogues on macrovascular complications are inconsistent; their benefits may be negated by increased risk of hypoglycemia which in turn increases adverse cardiovascular events. Increased cardiovascular risk of some antidiabetic drugs was missed during drug development and detected only on meta-analysis of clinical trial data. Regulatory agencies in North America and Europe have therefore proposed stringent guidelines for study design, data analysis and quantification of cardiovascular risk of new antidiabetic drugs. CONCLUSIONS: Physicians should weigh the cardiovascular risk against potential benefits when prescribing antidiabetic medications. The proposed regulatory measures will ensure approval of safer drugs, but may also lengthen the drug development cycle or even deter development of potentially useful drugs.


Asunto(s)
Enfermedades Cardiovasculares , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Angiopatías Diabéticas/prevención & control , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Administración Oral , Enfermedades Cardiovasculares/inducido químicamente , Enfermedades Cardiovasculares/prevención & control , Ensayos Clínicos como Asunto , Diabetes Mellitus Tipo 2/complicaciones , Aprobación de Drogas , Humanos , Preparaciones Farmacéuticas , Factores de Riesgo , Resultado del Tratamiento
15.
J Electrocardiol ; 44(2): 96-104, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21238976

RESUMEN

INTRODUCTION: We studied moxifloxacin-induced QT prolongation and proportion of categorical QTc outliers when 5 methods of QT measurement were used to analyze electrocardiograms (ECGs) from a thorough QT study. METHODS: QT interval was measured by the threshold, tangent, superimposed median beat, automated global median beat, and longest QT methods in a central ECG laboratory in 2730 digital ECGs from 39 subjects during placebo and moxifloxacin treatment. RESULTS: All 5 methods were able to demonstrate statistically significant moxifloxacin-induced QTcF prolongation. However, lower bound of 95% 1-sided confidence interval of QTcF prolongation did not exceed 5 milliseconds with the longest QT method. More QTcF outliers were observed with the longest QT and tangent methods, whereas the other 3 methods were comparable. QTcF values greater than 500 milliseconds were observed only with moxifloxacin by the tangent method, and with moxifloxacin and placebo by the longest QT method. CONCLUSION: The method of QT measurement must be considered when interpreting individual thorough QT/QTc studies.


Asunto(s)
Algoritmos , Artefactos , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Síndrome de QT Prolongado/diagnóstico , Animales , Frecuencia Cardíaca , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Ann Noninvasive Electrocardiol ; 14(1): 19-25, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19149789

RESUMEN

BACKGROUND: ECGs from thorough QT studies must be read in a central laboratory by trained experts. Standards of expertise are not presently defined. We, therefore, studied the use of Z-scores to define reader competence. METHODS: Two hundred ECGs were read by 24 experts and the mean and standard deviation (SD) of QT measurements calculated for each ECG. Z-scores ([QT(reader)- mean QT(experts)]/ SD(experts)) for each ECG and mean of absolute Z-scores of all ECGs read by a reader were calculated. The highest mean absolute Z-score of experts was considered the cutoff to define competence. Hundred of these standardized ECGs were used to assess performance of readers from the central laboratory. RESULTS: All experts had mean absolute Z-scores < or = 1.5. Using this cutoff, one of 28 experienced readers and 7 of 15 trainees had unacceptable Z-scores. After re-training, all achieved Z-scores <1.5. Comparing histograms of actual Z-scores of the 100 ECGs of readers with unacceptable scores with that of the reader with the best Z-score showed two patterns. Readers with histograms having a peak and tails similar to that of the best reader, but with leftward or rightward shift, consistently made shorter or longer QT measurements, respectively. A histogram with a flatter peak and wider tails, suggested that measurements were long in some ECGs and short in others. CONCLUSION: Mean absolute Z-score is useful to assess competence for measuring the QT interval on ECGs. Analysis of histograms can pinpoint problems in QT measurements.


Asunto(s)
Benchmarking/métodos , Cardiología , Competencia Clínica , Electrocardiografía/métodos , Laboratorios , Síndrome de QT Prolongado/diagnóstico , Femenino , Humanos , India , Masculino , Variaciones Dependientes del Observador , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Gestión de la Calidad Total
17.
J Electrocardiol ; 42(4): 348-52, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19261293

RESUMEN

BACKGROUND: The QT interval can be measured by tangent (QT(Tan)) and threshold (QT(Thr)) methods; the better method is the one with lower reader variability. METHODS: QT(Tan) and QT(Thr) were measured twice in 100 digital electrocardiograms (ECGs) by 8 experienced readers in a central laboratory. For QT(Thr), the end of the T wave was the point where the T wave reached the isoelectric baseline; for QT(Tan), it was the point where a line from the peak of the T wave through the steepest part of the descending limb intercepted the isoelectric baseline. RESULTS: The average absolute intrareader variability ranged from 3.4 to 6.9 milliseconds for QT(Tan) and from 3.5 to 5.2 milliseconds for QT(Thr). By analysis of variance, intrareader SD of QT(Tan) was 7.0 and 7.5 milliseconds for QT(Thr); interreader SD was 13.1 milliseconds for QT(Tan) and 11.9 milliseconds for QT(Thr). QT(Tan) was shorter than QT(Thr) in 96 of the 100 ECGs, it exceeded QT(Thr) in 4 ECGs, which had prominent U waves. CONCLUSIONS: For trained readers in a central ECG laboratory using sophisticated on-screen tools for QT measurement in high-quality digital ECGs, between- and within-reader variability are comparable for QT(Tan) and QT(Thr). However, QT(Tan) is consistently shorter than QT(Thr) by up to 10 milliseconds.


Asunto(s)
Algoritmos , Arritmias Cardíacas/diagnóstico , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
J Electrocardiol ; 41(5): 370-5, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18482732

RESUMEN

BACKGROUND: Prints of electrocardiograms (ECGs) are often sent to core laboratories, where they are scanned, converted to a digital format, and read on-screen. These ECGs may differ from the original ECG because of variability introduced by the printer, scanner, or digitization software. METHODS: Digital ECGs were recorded in 50 volunteers simultaneously using electrocardiographs from 2 different manufacturers. QT and RR intervals were measured on-screen on the digitized ECGs. To study the contribution of individual steps in the digitization process, differences in RR interval between 2 prints each of 50 digital ECGs, 2 scanned files of 50 prints, 2 digitized files from 50 scanned files, and 2 readings of 50 digitized ECGs (intrareader variability) were analyzed. RESULTS: Repeatability coefficient for RR interval measurement was 18.5 milliseconds for machine 1 and 21 milliseconds for machine 2. Contributions of the printer were 6.5 milliseconds for machine 1 and 9.0 milliseconds for machine 2, digitization process was 5.5 milliseconds, and reader variability was 8.0 milliseconds. Variability of the scanner was negligible. CONCLUSIONS: The printer and digitization process account for significant differences in interval measurements in digitized ECGs.


Asunto(s)
Artefactos , Periféricos de Computador , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Frecuencia Cardíaca/fisiología , Procesamiento de Señales Asistido por Computador/instrumentación , Adulto , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Papel , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
J Clin Pharmacol ; 58(8): 1013-1019, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29775213

RESUMEN

Although fixed QT correction methods are typically used to adjust for the effect of heart rate on the QT interval in thorough QT/QTc studies, individual-specific QT correction (QTcI = QT/RRI ) is advisable for drugs that increase the heart rate by >5 to 10 beats/minute (bpm). QTcI is traditionally derived using resting drug-free electrocardiograms (ECGs) collected at prespecified times. However, the resting heart rate range in healthy individuals is narrow, and extrapolation of inferences from these data to higher heart rates could be inappropriate. Accordingly, the QTcI derived from triplicate ECGs extracted at prespecified times (the traditional [T] method, yielding QTcIT) was compared with QTcIs obtained using ECGs with a wider heart rate range (alternative Holter [H] method, yielding QTcIH) from 24-hour Holter recordings from 40 healthy individuals selected from a central ECG laboratory database. For QTcIH, 10-second ECGs were extracted at stable heart rates in the ranges of 51-60, 61-70, 71-80, and 81-90 bpm (9 ECGs in each bin = 36 ECGs). An independent set of 40 ECGs with heart rates from 51 to 90 bpm was extracted from each individual to validate the accuracy of QTcI by the 2 methods. For the validation set, the QTcIH was a better QT correction method (slope of QTc vs heart rate closer to zero) than QTcIT. The mean difference between QTcIT and QTcIH increased from 3.1 milliseconds at 65 bpm to 10.0 milliseconds at 90 bpm (P < 0.01). The QTcIT exceeded QTcIH at heart rates > 60 bpm. Employment of the QTcIH may be more appropriate for studies involving drugs that increase heart rate.

20.
Eur Heart J Cardiovasc Pharmacother ; 3(2): 118-124, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28363206

RESUMEN

Following marketing withdrawals of several drugs due to proarrhythmic safety concerns, the ICH Guidelines S7B and E14 were released in 2005 and have guided pre-approval cardiac safety assessments in multiple regulatory jurisdictions. While this S7B-E14 paradigm has successfully prevented drugs with unanticipated potential for inducing Torsades de Pointes entering the market, it has unintentionally resulted in the termination of development programs for potentially important compounds that could have exhibited a favourable benefit-risk balance. The Comprehensive In vitro Proarrhythmia Assay paradigm is currently attracting considerable attention as a solution to this problem. While much evaluative work in this new paradigm will be conducted in the non-clinical domain, human electrocardiographic assessments will remain an important component of the overall investigational strategy, possibly being conducted in Phase I trials employing exposure-response modelling. This article reviews recent developments in proarrhythmic cardiac safety assessments of new drugs, their rationales, and current limitations.


Asunto(s)
Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/tratamiento farmacológico , Evaluación de Medicamentos/métodos , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA