RESUMEN
OBJECTIVES: The IKORUS system (Vygon, Écouen, France) allows continuous monitoring of the urethral perfusion index (uPI) using a photoplethysmographic sensor mounted near the base of the balloon of a dedicated urinary catheter. We aimed to test the hypothesis that the uPI decreases during off-pump coronary artery bypass (OPCAB) surgery and to investigate the relationship between the uPI and macrocirculatory variables. DESIGN: Prospective observational study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PARTICIPANTS: Twenty patients having OPCAB surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was changes in the uPI during OPCAB surgery. We additionally investigated associations between the uPI and cardiac output, mean arterial pressure, heart rate, and point-of-care variables. Twenty patients with 24,137 uPI measurements were included. Overall, there was a high interindividual variability in the uPI. Compared with the preparation phase (during which the median [interquartile range] uPI was 7.7 [5.6-12.0]), the uPI decreased by 14% (95% CI 13%-15%) during the bypass grafting phase, by 35% (95% CI 34%-36%) during the cardiac positioning phase, and by 7% (95% CI 6%-9%) during hemostasis. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. CONCLUSIONS: The uPI decreases during OPCAB surgery, specifically during the cardiac positioning phase. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. It, therefore, remains to be determined whether intraoperative uPI decreases are clinically important, reflect alterations in intra-abdominal tissue perfusion that are not reflected by systemic macrohemodynamics, and can help clinicians guide therapeutic interventions.
Asunto(s)
Puente de Arteria Coronaria Off-Pump , Humanos , Presión Arterial , Gasto Cardíaco/fisiología , Frecuencia Cardíaca/fisiología , Índice de Perfusión , Estudios ProspectivosRESUMEN
During surgery, various haemodynamic variables are monitored and optimised to maintain organ perfusion pressure and oxygen delivery - and to eventually improve outcomes. Important haemodynamic variables that provide an understanding of most pathophysiologic haemodynamic conditions during surgery include heart rate, arterial pressure, central venous pressure, pulse pressure variation/stroke volume variation, stroke volume, and cardiac output. A basic physiologic and pathophysiologic understanding of these haemodynamic variables and the corresponding monitoring methods is essential. We therefore revisit the pathophysiologic rationale for intraoperative monitoring of haemodynamic variables, describe the history, current use, and future technological developments of monitoring methods, and finally briefly summarise the evidence that haemodynamic management can improve patient-centred outcomes.
Asunto(s)
Gasto Cardíaco , Monitorización Hemodinámica , Hemodinámica , Monitoreo Intraoperatorio , Volumen Sistólico , Humanos , Monitoreo Intraoperatorio/métodos , Monitorización Hemodinámica/métodos , Volumen Sistólico/fisiología , Frecuencia Cardíaca/fisiología , Presión Venosa Central , Presión Sanguínea , Procedimientos Quirúrgicos Operativos , Presión ArterialRESUMEN
PURPOSE: There are different techniques for ultrasound-guided central venous catheter (CVC) insertion. When using the conventional syringe-on-needle technique, the syringe needs to be removed from the needle after venous puncture to pass the guidewire through the needle into the vein. When, alternatively, using the wire-in-needle technique, the needle is preloaded with the guidewire, and the guidewire-after venous puncture-is advanced into the vein under real-time ultrasound guidance. We tested the hypothesis that the wire-in-needle technique reduces the time to successful guidewire insertion in the internal jugular vein compared with the syringe-on-needle technique in adults. METHODS: We randomized 250 patients to the wire-in-needle or syringe-on-needle technique. Our primary endpoint was the time to successful guidewire insertion in the internal jugular vein. RESULTS: Two hundred and thirty eight patients were analyzed. The median (25th percentile, 75th percentile) time to successful guidewire insertion was 22 (16, 38) s in patients assigned to the wire-in-needle technique and 25 (19, 34) s in patients assigned to the syringe-on-needle technique (estimated location shift: 2 s; 95%-confidence-interval: - 1 to 5 s, p = 0.165). CVC insertion was successful on the first attempt in 103/116 patients (89%) assigned to the wire-in-needle technique and in 113/122 patients (93%) assigned to the syringe-on-needle technique. CVC insertion-related complications occurred in 8/116 patients (7%) assigned to the wire-in-needle technique and 19/122 patients (16%) assigned to the syringe-on-needle technique. CONCLUSION: The wire-in-needle technique-compared with the syringe-on-needle technique-did not reduce the time to successful guidewire insertion in the internal jugular vein. Clinicians can consider either technique for ultrasound-guided CVC insertion in adults.
RESUMEN
Intraoperative hypotension is common and associated with organ injury. Hypotension can not only occur during surgery, but also thereafter. After surgery, most patients are treated in post-anesthesia care units (PACU). The incidence of PACU hypotension is largely unknown - presumably in part because arterial pressure is usually monitored intermittently in PACU patients. We therefore aimed to evaluate the incidence, duration, and severity of PACU hypotension in low-risk patients recovering from non-cardiac surgery. In this observational study, we performed blinded continuous non-invasive arterial pressure monitoring with finger-cuffs (ClearSight system; Edwards Lifesciences, Irvine, CA, USA) in 100 patients recovering from non-cardiac surgery in the PACU. We defined PACU hypotension as a mean arterial pressure (MAP) < 65 mmHg. Patients had continuous finger-cuff monitoring for a median (25th percentile, 75th percentile) of 64 (44 to 91) minutes. Only three patients (3%) had PACU hypotension for at least one consecutive minute. These three patients had 4, 4, and 2 cumulative minutes of PACU hypotension; areas under a MAP of 65 mmHg of 17, 9, and 9 mmHg x minute; and time-weighted averages MAP less than 65 mmHg of 0.5, 0.3, and 0.2 mmHg. The median volume of crystalloid fluid patients were given during PACU treatment was 200 (100 to 400) ml. None was given colloids or a vasopressor during PACU treatment. In low-risk patients recovering from non-cardiac surgery, the incidence of PACU hypotension was very low and the few episodes of PACU hypotension were short and of modest severity.
RESUMEN
Haemodynamic monitoring and management are cornerstones of perioperative care. The goal of haemodynamic management is to maintain organ function by ensuring adequate perfusion pressure, blood flow, and oxygen delivery. We here present guidelines on "Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery" that were prepared by 18 experts on behalf of the German Society of Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin; DGAI).
Asunto(s)
Anestesiología , Cuidados Críticos , Monitorización Hemodinámica , Hemodinámica , Monitoreo Intraoperatorio , Sociedades Médicas , Adulto , Humanos , Anestesiología/métodos , Anestesiología/normas , Cuidados Críticos/métodos , Cuidados Críticos/normas , Alemania , Monitorización Hemodinámica/métodos , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/normas , Atención Perioperativa/métodos , Atención Perioperativa/normas , Sociedades Científicas , Procedimientos Quirúrgicos Operativos , Literatura de Revisión como AsuntoRESUMEN
BACKGROUND: Finger-cuff methods allow noninvasive continuous arterial pressure monitoring. This study aimed to determine whether continuous finger-cuff arterial pressure monitoring helps clinicians reduce hypotension within 15 min after starting induction of anesthesia and during noncardiac surgery. Specifically, this study tested the hypotheses that continuous finger-cuff-compared to intermittent oscillometric-arterial pressure monitoring helps clinicians reduce the area under a mean arterial pressure of 65 mmHg within 15 min after starting induction of anesthesia and the time-weighted average mean arterial pressure less than 65 mmHg during noncardiac surgery. METHODS: In this single-center trial, 242 noncardiac surgery patients were randomized to unblinded continuous finger-cuff arterial pressure monitoring or to intermittent oscillometric arterial pressure monitoring (with blinded continuous finger-cuff arterial pressure monitoring). The first of two hierarchical primary endpoints was the area under a mean arterial pressure of 65 mmHg within 15 min after starting induction of anesthesia; the second primary endpoint was the time-weighted average mean arterial pressure less than 65 mmHg during surgery. RESULTS: Within 15 min after starting induction of anesthesia, the median (interquartile range) area under a mean arterial pressure of 65 mmHg was 7 (0, 24) mmHg × min in 109 patients assigned to continuous finger-cuff monitoring versus 19 (0.3, 60) mmHg × min in 113 patients assigned to intermittent oscillometric monitoring (P = 0.004; estimated location shift: -6 [95% CI: -15 to -0.3] mmHg × min). During surgery, the median (interquartile range) time-weighted average mean arterial pressure less than 65 mmHg was 0.04 (0, 0.27) mmHg in 112 patients assigned to continuous finger-cuff monitoring and 0.40 (0.03, 1.74) mmHg in 115 patients assigned to intermittent oscillometric monitoring (P < 0.001; estimated location shift: -0.17 [95% CI: -0.41 to -0.05] mmHg). CONCLUSIONS: Continuous finger-cuff arterial pressure monitoring helps clinicians reduce hypotension within 15 min after starting induction of anesthesia and during noncardiac surgery compared to intermittent oscillometric arterial pressure monitoring.
Asunto(s)
Anestesia , Hipotensión , Humanos , Presión Arterial , Hipotensión/diagnóstico , Determinación de la Presión Sanguínea/métodos , Procedimientos Quirúrgicos Vasculares , Presión SanguíneaRESUMEN
PURPOSE OF REVIEW: The measurement of cardiac output ( CO ) is important in patients with circulatory shock. Pulse wave analysis (PWA) estimates CO continuously and in real-time using the mathematical analysis of the arterial pressure waveform. We describe different PWA methods and provide a framework for CO monitoring using PWA in critically ill patients. RECENT FINDINGS: PWA monitoring systems can be classified according to their invasiveness (into invasive, minimally invasive, and noninvasive systems) and their calibration method (into externally calibrated, internally calibrated, and uncalibrated systems). PWA requires optimal arterial pressure waveform signals. Marked alterations and rapid changes in systemic vascular resistance and vasomotor tone can impair the measurement performance of PWA. SUMMARY: Noninvasive PWA methods are generally not recommended in critically ill patients (who have arterial catheters anyway). PWA systems can be used to continuously track stroke volume and CO in real-time during tests of fluid responsiveness or during therapeutic interventions. During fluid challenges, continuous CO monitoring is important because - if CO decreases - a fluid challenge can be stopped early to avoid further unnecessary fluid administration. PWA externally calibrated to indicator dilution methods can be used - in addition to echocardiography - to diagnose the type of shock.
Asunto(s)
Presión Arterial , Enfermedad Crítica , Humanos , Gasto Cardíaco , Frecuencia Cardíaca , Cuidados CríticosRESUMEN
Flow-directed, balloon-tipped pulmonary artery catheters allow measuring cardiac output and other haemodynamic variables including intracardiac pressures. We propose classifying pulmonary artery catheters by generations and specifying additional measurement modalities. Based on the method used to measure cardiac output, pulmonary artery catheters can be classified into three generations: first-generation using intermittent pulmonary artery thermodilution; second-generation using a thermal filament for automated pulmonary artery thermodilution; and third-generation combining thermal filament-based automated pulmonary artery thermodilution and pulmonary artery pulse wave analysis. Each of these pulmonary artery catheter generations can include additional measurements, such as continuous mixed venous oxygen saturation, right ventricular ejection fraction and end-diastolic volume, and right ventricular pressure. This classification should help define indications for pulmonary artery catheters in clinical practice and research.
Asunto(s)
Arteria Pulmonar , Función Ventricular Derecha , Humanos , Volumen Sistólico , Cateterismo de Swan-Ganz , Gasto Cardíaco , Termodilución/métodos , CatéteresRESUMEN
BACKGROUND: Intraoperative hypotension is associated with myocardial injury, acute kidney injury, and death. In routine practice, specific causes of intraoperative hypotension are often unclear. A more detailed understanding of underlying haemodynamic alterations of intraoperative hypotension may identify specific treatments. We thus aimed to use machine learning - specifically, hierarchical clustering - to identify underlying haemodynamic alterations causing intraoperative hypotension in major abdominal surgery patients. Specifically, we tested the hypothesis that there are distinct endotypes of intraoperative hypotension, which may help refine therapeutic interventions. METHODS: We conducted a secondary analysis of intraoperative haemodynamic measurements from a prospective observational study in 100 patients who had major abdominal surgery under general anaesthesia. We used stroke volume index, heart rate, cardiac index, systemic vascular resistance index, and pulse pressure variation measurements. Intraoperative hypotension was defined as any mean arterial pressure ≤65 mm Hg or a mean arterial pressure between 66 and 75 mm Hg requiring a norepinephrine infusion rate exceeding 0.1 µg kg-1 min-1. To identify endotypes of intraoperative hypotension, we used hierarchical clustering (Ward's method). RESULTS: A total of 615 episodes of intraoperative hypotension occurred in 82 patients (46 [56%] female; median age: 64 [57, 73] yr) who had surgery of a median duration of 270 (195, 335) min. Hierarchical clustering revealed six distinct intraoperative hypotension endotypes. Based on their clinical characteristics, we labelled these endotypes as (1) myocardial depression, (2) bradycardia, (3) vasodilation with cardiac index increase, (4) vasodilation without cardiac index increase, (5) hypovolaemia, and (6) mixed type. CONCLUSION: Hierarchical clustering identified six endotypes of intraoperative hypotension. If validated, considering these intraoperative hypotension endotypes may enable causal treatment of intraoperative hypotension.
Asunto(s)
Hipotensión , Monitoreo Intraoperatorio , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Monitoreo Intraoperatorio/métodos , Hipotensión/etiología , Estudios de Cohortes , Aprendizaje Automático , Complicaciones PosoperatoriasRESUMEN
BACKGROUND: Perioperative hemodynamic management aims to optimize organ perfusion pressure and blood flow-assuming this ensures that oxygen delivery meets cellular metabolic needs. Cellular metabolic needs are reflected by energy expenditure. A better understanding of energy expenditure under general anesthesia could help tailor perioperative hemodynamic management to actual demands. We thus sought to assess energy expenditure under general anesthesia. Our primary hypothesis was that energy expenditure under general anesthesia is lower than preoperative awake resting energy expenditure. METHODS: We conducted an observational study on patients having elective noncardiac surgery at the University Medical Center Hamburg-Eppendorf (Germany) between September 2019 and March 2020. We assessed preoperative awake resting energy expenditure, energy expenditure under general anesthesia, and energy expenditure after surgery using indirect calorimetry. We compared energy expenditure under general anesthesia at incision to preoperative awake resting energy expenditure using a Wilcoxon signed-rank test for paired measurements. RESULTS: We analyzed 60 patients. Median (95% confidence interval [CI]) preoperative awake resting energy expenditure was 953 (95% CI, 906-962) kcal d -1 m -2 . Median energy expenditure under general anesthesia was 680 (95% CI, 642-711) kcal d -1 m -2 -and thus 263 (95% CI, 223-307) kcal d -1 m -2 or 27% (95% CI, 23%-30%) lower than preoperative awake resting energy expenditure ( P < .001). CONCLUSIONS: Median energy expenditure under general anesthesia is about one-quarter lower than preoperative awake resting energy expenditure in patients having noncardiac surgery.
Asunto(s)
Metabolismo Basal , Metabolismo Energético , Humanos , Calorimetría Indirecta , Anestesia General , AlemaniaRESUMEN
Hypotension can occur before, during, and after surgery and is associated with postoperative complications. Anesthesiologists should thus avoid profound and prolonged hypotension. A crucial part of avoiding hypotension is accurate and tight blood pressure monitoring. In this narrative review, we briefly describe methods for continuous blood pressure monitoring, discuss current evidence for continuous blood pressure monitoring in patients having surgery to reduce perioperative hypotension, and expand on future directions and innovations in this field. In summary, continuous blood pressure monitoring with arterial catheters or noninvasive sensors enables clinicians to detect and treat hypotension immediately. Furthermore, advanced hemodynamic monitoring technologies and artificial intelligence-in combination with continuous blood pressure monitoring-may help clinicians identify underlying causes of hypotension or even predict hypotension before it occurs.
Asunto(s)
Inteligencia Artificial , Hipotensión , Humanos , Presión Sanguínea , Monitoreo Intraoperatorio/efectos adversos , Monitoreo Intraoperatorio/métodos , Determinación de la Presión Sanguínea/métodos , Hipotensión/diagnósticoRESUMEN
BACKGROUND: Hypotension during induction of anaesthesia is associated with organ injury. Continuous arterial pressure monitoring might help reduce hypotension. We tested the hypothesis that continuous intra-arterial compared with intermittent oscillometric arterial pressure monitoring reduces hypotension during induction of anaesthesia in noncardiac surgery patients. METHODS: In this single-centre randomised trial, 242 noncardiac surgery patients in whom intra-arterial arterial pressure monitoring was planned were randomised to unblinded continuous intra-arterial or to intermittent oscillometric arterial pressure monitoring (with blinded intra-arterial arterial pressure monitoring) during induction of anaesthesia. The primary endpoint was the area under a mean arterial pressure (MAP) of 65 mm Hg within the first 15 min of induction of anaesthesia. Secondary endpoints included areas under MAP values of 60, 50, and 40 mm Hg and durations of MAP values <65, <60, <50, and <40 mm Hg. RESULTS: There were 224 subjects available for analysis. The median (25th-75th percentile) area under a MAP of 65 mm Hg was 15 (2-36) mm Hg ⢠min in subjects assigned to continuous intra-arterial monitoring and 46 (7-111) mm Hg ⢠min in subjects assigned to intermittent oscillometric monitoring (P<0.001). Subjects assigned to continuous intra-arterial monitoring had smaller areas under MAP values of 60, 50, and 40 mm Hg and shorter durations of MAP values <65, <60, <50, and <40 mm Hg than subjects assigned to intermittent oscillometric monitoring. CONCLUSION: Continuous intra-arterial arterial pressure monitoring reduces hypotension during induction of anaesthesia compared with intermittent oscillometric arterial pressure monitoring in noncardiac surgery patients. In patients for whom an arterial catheter is planned, clinicians might therefore consider inserting the arterial catheter before rather than after induction of anaesthesia. CLINICAL TRIALS REGISTRATION: NCT04894019.
Asunto(s)
Determinación de la Presión Sanguínea , Hipotensión , Anestesia General/efectos adversos , Presión Arterial , Humanos , Hipotensión/diagnóstico , Hipotensión/etiología , Hipotensión/prevención & control , VigiliaRESUMEN
BACKGROUND: Cardiac output is an important hemodynamic variable and determines oxygen delivery. In contrast to blood pressure, cardiac output is rarely measured even in high-risk surgical patients, suggesting that clinicians consider blood pressure to be a reasonable indicator of systemic blood flow. However, the relationship depends on constant vascular tone and volume, both of which routinely vary during anesthesia and surgery. We therefore tested the hypothesis that there is no clinically meaningful correlation between mean arterial pressure and cardiac index in major abdominal surgery patients. METHODS: In this prospective observational study, we assessed the relationship between mean arterial pressure and cardiac index in 100 patients having major abdominal surgery under general anesthesia. RESULTS: The pooled within-patient correlation coefficient calculated using meta-analysis methods was r = 0.34 (95% confidence interval, 0.28-0.40). Linear regression using a linear mixed effects model of cardiac index on mean arterial pressure revealed that cardiac index increases by 0.014 L·min-1·m-2 for each 1 mm Hg increase in mean arterial pressure. The 95% Wald confidence interval of this slope was 0.011 to 0.018 L·min-1·m-2·mm Hg-1 and thus within predefined equivalence margins of -0.03 and 0.03 L·min-1·m-2·mm Hg-1, thereby demonstrating lack of clinically meaningful association between mean arterial pressure and cardiac index. CONCLUSIONS: There is no clinically meaningful correlation between mean arterial pressure and cardiac index in patients having major abdominal surgery. Intraoperative blood pressure is thus a poor surrogate for cardiac index.
Asunto(s)
Abdomen/cirugía , Presión Arterial/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Gasto Cardíaco/fisiología , Monitoreo Intraoperatorio/métodos , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios ProspectivosRESUMEN
BACKGROUND: Arterial hypertension is a worldwide public health problem. While it is currently diagnosed and monitored non-invasively using the oscillometric method, having the ability to measure blood pressure (BP) using a smartphone application could provide more widespread access to hypertension screening and monitoring. In this observational study in intensive care unit patients, we compared blood pressure values obtained using a new optical smartphone application (OptiBP™; test method) with arterial BP values obtained using a radial artery catheter (reference method) in order to help validate the technology. METHODS: We simultaneously measured three BP values every hour for five consecutive hours on two consecutive days using both the smartphone and arterial methods. Bland-Altman and error grid analyses were used for agreement analysis between both approaches. The performance of the smartphone application was investigated using the Association for the Advancement of Medical Instrumentation (AAMI) and the International Organization for Standardization (ISO) definitions, which require the bias ± SD between two technologies to be below 5 ± 8 mmHg. RESULTS: Among the 30 recruited patients, 22 patients had adequate OptiBP™ values and were thus analyzed. In the other 8 patients, no BP could be measured due to inadequate signals. The Bland-Altman analysis revealed a mean of the differences ± SD between both methods of 0.9 ± 7 mmHg for mean arterial pressure (MAP), 0.2 ± 14 mmHg for systolic arterial pressure (SAP), and 1.1 ± 6 mmHg for diastolic arterial pressure (DAP). Error grid analysis demonstrated that the proportions of measurement pairs in risk zones A to E were 88.8% (no risk), 10% (low risk), 1% (moderate risk), 0% (significant risk), and 0% (dangerous risk) for MAP and 88.4%, 8.6%, 3%, 0%, 0%, respectively, for SAP. CONCLUSIONS: This method comparison study revealed good agreement between BP values obtained using the OptiBP™ and those done invasively. The OptiBP™ fulfills the AAMI/ISO universal standards for MAP and DAP (but not SAP). Error grid showed that the most measurements (≥ 97%) were in risk zones A and B. TRIAL REGISTRATION: ClinicalTrials.gov registration: NCT04728477.
Asunto(s)
Presión Arterial , Hipertensión , Presión Arterial/fisiología , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Humanos , Unidades de Cuidados Intensivos , Teléfono InteligenteRESUMEN
BACKGROUND: The NICCI system (Getinge, Gothenburg, Sweden) is a new noninvasive haemodynamic monitoring system using a finger sensor. OBJECTIVES: We aimed to investigate the performance of the NICCI system to measure blood pressure and pulse pressure variation compared with intra-arterial measurements. DESIGN: A prospective method comparison study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PATIENTS: Forty-seven neurosurgery patients. MAIN OUTCOME MEASURES: We performed a method comparison study in 47 neurosurgery patients to compare NICCI blood pressure measurements (BP NICCI ) with intra-arterial blood pressure measurements (BP ART ) (Bland-Altman analysis, four-quadrant plot, error grid analysis) and NICCI pulse pressure variation measurements (PPV NICCI ) with pulse pressure variation calculated manually from the intra-arterial blood pressure waveform (PPV ART ) (Bland-Altman analysis, predictive agreement, Cohen's kappa). RESULTS: The mean of the differencesâ±âstandard deviation (95% limits of agreement) between BP NICCI and BP ART was 11â±â10âmmHg (-8 to 30âmmHg) for mean blood pressure (MBP), 3â±â12âmmHg (-21 to 26âmmHg) for systolic blood pressure (SBP) and 12â±â10âmmHg (-8 to 31âmmHg) for diastolic blood pressure (DBP). In error grid analysis, 54% of BP NICCI and BP ART MBP measurement pairs were classified as 'no risk', 43% as 'low risk', 3% as 'moderate risk' and 0% as 'significant risk' or 'dangerous risk'. The mean of the differences between PPV NICCI and PPV ART was 1â±â3% (-4 to 6%). The predictive agreement between PPV NICCI and PPV ART was 80% and Cohen's kappa was 0.55. CONCLUSIONS: The absolute agreement between BP NICCI and BP ART was not clinically acceptable. We recommend not using the current version of the NICCI system for blood pressure monitoring during surgery. The absolute agreement between PPV NICCI and PPV ART was clinically acceptable with moderate predictive agreement regarding pulse pressure variation categories. The NICCI system needs to be further developed and re-evaluated when an improved version is available. TRIAL REGISTRATION: The study was registered in the German Clinical Trials Register (DRKS00023188) on 2 October 2020.
Asunto(s)
Neurocirugia , Presión Arterial/fisiología , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Humanos , Monitoreo Intraoperatorio/métodosRESUMEN
BACKGROUND: The new noninvasive finger sensor system NICCI (Getinge; Gothenburg, Sweden) allows continuous cardiac output monitoring. We aimed to investigate its cardiac output measurement performance. OBJECTIVES: To investigate the NICCI system's cardiac output measurement performance. DESIGN: Prospective method comparison study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PATIENTS: Fifty-one patients after cardiac surgery. MAIN OUTCOME MEASURES: We performed a method comparison study in 51 patients after cardiac surgery to compare NICCI cardiac output (CO NICCI ) and NICCI cardiac output calibrated to pulmonary artery thermodilution cardiac output measurement (CO NICCI-CAL ) with pulmonary artery thermodilution cardiac output (CO PAT ). As a secondary analysis we also compared CNAP cardiac output (CO CNAP ) and externally calibrated CNAP cardiac output (CO CNAP-CAL ) with CO PAT . RESULTS: We analysed 299 cardiac output measurement pairs. The mean of the differences (95% limits of agreement) between CO NICCI and CO PAT was 0.6 (-1.8 to 3.1) l min -1 with a percentage error of 48%. The mean of the differences between CO NICCI-CAL and CO PAT was -0.4 (-1.9 to 1.1) l min -1 with a percentage error of 29%. The mean of the differences between CO CNAP and CO PAT was 1.0 (-1.8 to 3.8) l min -1 with a percentage error of 53%. The mean of the differences between CO CNAP-CAL and CO PAT was -0.2 (-2.0 to 1.6) l min -1 with a percentage error of 35%. CONCLUSION: The agreement between CO NICCI and CO PAT is not clinically acceptable. TRIAL REGISTRATION: The study was registered in the German Clinical Trial Register (DRKS00023189) after inclusion of the first patient on October 2, 2020.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Termodilución , Gasto Cardíaco , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Monitoreo Fisiológico/métodos , Reproducibilidad de los Resultados , Termodilución/métodosRESUMEN
BACKGROUND: Handheld vital microscopy allows direct observation of red blood cells within the sublingual microcirculation. Automated analysis allows quantifying microcirculatory tissue perfusion variables - including tissue red blood cell perfusion (tRBCp), a functional variable integrating microcirculatory convection and diffusion capacities. OBJECTIVE: We aimed to describe baseline microcirculatory tissue perfusion in patients presenting for elective noncardiac surgery and test that microcirculatory tissue perfusion is preserved during elective general anaesthesia for noncardiac surgery. DESIGN: Prospective observational study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PATIENTS: 120 elective noncardiac surgery patients (major abdominal, orthopaedic or trauma and minor urologic surgery) and 40 young healthy volunteers. MAIN OUTCOME MEASURES: We measured sublingual microcirculation using incident dark field imaging with automated analysis at baseline before induction of general anaesthesia, under general anaesthesia before surgical incision and every 30âmin during surgery. We used incident the dark field imaging technology with a validated automated analysis software. RESULTS: A total of 3687 microcirculation video sequences were analysed. Microcirculatory tissue perfusion variables varied substantially between individuals - but ranges were similar between patients and volunteers. Under general anaesthesia before surgical incision, there were no important changes in tRBCp, functional capillary density and capillary haematocrit compared with preinduction baseline. However, total vessel density was higher and red blood cell velocity and the proportion of perfused vessels were lower under general anaesthesia. There were no important changes in any microcirculatory tissue perfusion variables during surgery. CONCLUSION: In patients presenting for elective noncardiac surgery, baseline microcirculatory tissue perfusion variables vary substantially between individuals - but ranges are similar to those in young healthy volunteers. Microcirculatory tissue perfusion is preserved during general anaesthesia and noncardiac surgery - when macrocirculatory haemodynamics are maintained.
Asunto(s)
Herida Quirúrgica , Anestesia General , Hemodinámica/fisiología , Humanos , Microcirculación/fisiología , PerfusiónRESUMEN
The finger-cuff system CNAP (CNSystems Medizintechnik, Graz, Austria) allows non-invasive automated measurement of pulse pressure variation (PPVCNAP). We sought to validate the PPVCNAP-algorithm and investigate the agreement between PPVCNAP and arterial catheter-derived manually calculated pulse pressure variation (PPVINV). This was a prospective method comparison study in patients having neurosurgery. PPVINV was the reference method. We applied the PPVCNAP-algorithm to arterial catheter-derived blood pressure waveforms (PPVINV-CNAP) and to CNAP finger-cuff-derived blood pressure waveforms (PPVCNAP). To validate the PPVCNAP-algorithm, we compared PPVINV-CNAP to PPVINV. To investigate the clinical performance of PPVCNAP, we compared PPVCNAP to PPVINV. We used Bland-Altman analysis (absolute agreement), Deming regression, concordance, and Cohen's kappa (predictive agreement for three pulse pressure variation categories). We analyzed 360 measurements from 36 patients. The mean of the differences between PPVINV-CNAP and PPVINV was -0.1% (95% limits of agreement (95%-LoA) -2.5 to 2.3%). Deming regression showed a slope of 0.99 (95% confidence interval (95%-CI) 0.91 to 1.06) and intercept of -0.02 (95%-CI -0.52 to 0.47). The predictive agreement between PPVINV-CNAP and PPVINV was 92% and Cohen's kappa was 0.79. The mean of the differences between PPVCNAP and PPVINV was -1.0% (95%-LoA-6.3 to 4.3%). Deming regression showed a slope of 0.85 (95%-CI 0.78 to 0.91) and intercept of 0.10 (95%-CI -0.34 to 0.55). The predictive agreement between PPVCNAP and PPVINV was 82% and Cohen's kappa was 0.48. The PPVCNAP-algorithm reliably calculates pulse pressure variation compared to manual offline pulse pressure variation calculation when applied on the same arterial blood pressure waveform. The absolute and predictive agreement between PPVCNAP and PPVINV are moderate.
Asunto(s)
Neurocirugia , Presión Arterial/fisiología , Presión Sanguínea , Determinación de la Presión Sanguínea/métodos , Humanos , Estudios ProspectivosRESUMEN
PURPOSE: Predicting fluid responsiveness is essential when treating surgical or critically ill patients. When using a pulmonary artery catheter, pulse pressure variation and systolic pressure variation can be calculated from right ventricular and pulmonary artery pressure waveforms. METHODS: We conducted a prospective interventional study investigating the ability of right ventricular pulse pressure variation (PPVRV) and systolic pressure variation (SPVRV) as well as pulmonary artery pulse pressure variation (PPVPA) and systolic pressure variation (SPVPA) to predict fluid responsiveness in coronary artery bypass (CABG) surgery patients. Additionally, radial artery pulse pressure variation (PPVART) and systolic pressure variation (SPVART) were calculated. The area under the receiver operating characteristics (AUROC) curve with 95%-confidence interval (95%-CI) was used to assess the capability to predict fluid responsiveness (defined as an increase in cardiac index of > 15%) after a 500 mL crystalloid fluid challenge. RESULTS: Thirty-three patients were included in the final analysis. Thirteen patients (39%) were fluid-responders with a mean increase in cardiac index of 25.3%. The AUROC was 0.60 (95%-CI 0.38 to 0.81) for PPVRV, 0.63 (95%-CI 0.43 to 0.83) for SPVRV, 0.58 (95%-CI 0.38 to 0.78) for PPVPA, and 0.71 (95%-CI 0.52 to 0.89) for SPVPA. The AUROC for PPVART was 0.71 (95%-CI 0.53 to 0.89) and for SPVART 0.78 (95%-CI 0.62 to 0.94). The correlation between pulse pressure variation and systolic pressure variation measurements derived from the different waveforms was weak. CONCLUSIONS: Right ventricular and pulmonary artery pulse pressure variation and systolic pressure variation seem to be weak predictors of fluid responsiveness in CABG surgery patients.
Asunto(s)
Fluidoterapia , Arteria Pulmonar , Humanos , Presión Sanguínea , Estudios Prospectivos , Arteria Pulmonar/cirugía , Puente de Arteria Coronaria , Hemodinámica , Volumen SistólicoRESUMEN
We compared blood pressure (BP) values obtained with a new optical smartphone application (OptiBP™) with BP values obtained using a non-invasive automatic oscillometric brachial cuff (reference method) during the first 2 h of surveillance in a post-anesthesia care unit in patients after non-cardiac surgery. Three simultaneous BP measurements of both methods were recorded every 30 min over a 2-h period. The agreement between measurements was investigated using Bland-Altman and error grid analyses. We also evaluated the performance of the OptiBP™ using ISO81060-2:2018 standards which requires the mean of the differences ± standard deviation (SD) between both methods to be less than 5 mmHg ± 8 mmHg. Of 120 patients enrolled, 101 patients were included in the statistical analysis. The Bland-Altman analysis demonstrated a mean of the differences ± SD between the test and reference methods of + 1 mmHg ± 7 mmHg for mean arterial pressure (MAP), + 2 mmHg ± 11 mmHg for systolic arterial pressure (SAP), and + 1 mmHg ± 8 mmHg for diastolic arterial pressure (DAP). Error grid analysis showed that the proportions of measurement pairs in risk zones A to E were 90.3% (no risk), 9.7% (low risk), 0% (moderate risk), 0% (significant risk), 0% (dangerous risk) for MAP and 89.9%, 9.1%, 1%, 0%, 0% for SAP. We observed a good agreement between BP values obtained by the OptiBP™ system and BP values obtained with the reference method. The OptiBP™ system fulfilled the AAMI validation requirements for MAP and DAP and error grid analysis indicated that the vast majority of measurement pairs (≥ 99%) were in risk zones A and B.Trial Registration ClinicalTrials.gov Identifier: NCT04262323.