Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 307
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 149(10): 734-743, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-37874908

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in patients undergoing transcatheter aortic valve replacement (TAVR) and is associated with increased risk of bleeding and stroke. While left atrial appendage occlusion (LAAO) is approved as an alternative to anticoagulants for stroke prevention in patients with AF, placement of these devices in patients with severe aortic stenosis, or when performed at the same time as TAVR, has not been extensively studied. METHODS: WATCH-TAVR (WATCHMAN for Patients with AF Undergoing TAVR) was a multicenter, randomized trial evaluating the safety and effectiveness of concomitant TAVR and LAAO with WATCHMAN in AF patients. Patients were randomized 1:1 to TAVR + LAAO or TAVR + medical therapy. WATCHMAN patients received anticoagulation for 45 days followed by dual antiplatelet therapy until 6 months. Anticoagulation was per treating physician preference for patients randomized to TAVR + medical therapy. The primary noninferiority end point was all-cause mortality, stroke, and major bleeding at 2 years between the 2 strategies. RESULTS: The study enrolled 349 patients (177 TAVR + LAAO and 172 TAVR + medical therapy) between December 2017 and November 2020 at 34 US centers. The mean age of patients was 81 years, and the mean scores for CHA2DS2-VASc and HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly) were 4.9 and 3.0, respectively. At baseline, 85.4% of patients were taking anticoagulants and 71.3% patients were on antiplatelet therapy. The cohorts were well-balanced for baseline characteristics. The incremental LAAO procedure time was 38 minutes, and the median contrast volume used for combined procedures was 119 mL versus 70 mL with TAVR alone. At the 24-month follow-up, 82.5% compared with 50.8% of patients were on any antiplatelet therapy, and 13.9% compared with 66.7% of patients were on any anticoagulation therapy in TAVR + LAAO compared with TAVR + medical therapy group, respectively. For the composite primary end point, TAVR + LAAO was noninferior to TAVR + medical therapy (22.7 versus 27.3 events per 100 patient-years for TAVR + LAAO and TAVR + medical therapy, respectively; hazard ratio, 0.86 [95% CI, 0.60-1.22]; Pnoninferiority<0.001). CONCLUSIONS: Concomitant WATCHMAN LAAO and TAVR is noninferior to TAVR with medical therapy in severe aortic stenosis patients with AF. The increased complexity and risks of the combined procedure should be considered when concomitant LAAO is viewed as an alternative to medical therapy for patients with AF undergoing TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03173534.


Asunto(s)
Estenosis de la Válvula Aórtica , Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Apéndice Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
2.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36121045

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Implantación de Prótesis , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Ataque Isquémico Transitorio/etiología , Implantación de Prótesis/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
3.
Eur Heart J ; 45(21): 1890-1900, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38270189

RESUMEN

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Intervención Coronaria Percutánea , Resultado del Tratamiento , Factores de Riesgo
4.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38460161

RESUMEN

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Asunto(s)
Reestenosis Coronaria , Infarto del Miocardio , Femenino , Humanos , Anciano , Paclitaxel , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Stents , Resultado del Tratamiento , Muerte
5.
Eur J Nucl Med Mol Imaging ; 50(13): 3910-3916, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37606857

RESUMEN

PURPOSE: Transthyretin cardiac amyloidosis (ATTR-CA) is thought to be prevalent in patients with severe aortic stenosis (AS) who are referred for transcatheter aortic valve replacement (TAVR). However, prior studies were published when TAVR was only offered to elderly, inoperable, and high-risk patients. The aim of this study was to reevaluate the prevalence of ATTR-CA in a contemporary TAVR population and identify high-risk features to guide referral for technetium-99 pyrophosphate scan (99mTc-PyP scan) screening. METHODS: Patients seen in a multidisciplinary TAVR clinic for severe AS 70 years and older were referred for a 99mTc-PyP scan to evaluate for ATTR-CA. The primary outcome was the percent with a positive scan. The discriminatory ability of high-risk features was assessed to develop a more judicious screening system. RESULTS: Over the study period, 380 patients underwent screening, and 20 patients (5.3%) had a positive scan, with 17 patients having confirmed ATTR-CA, 1 patient deferring confirmatory testing (combined 4.7%), 1 having light chain amyloidosis, and 1 negative on biopsy. Compared to other patient and echocardiographic measures, elevated NT-pro BNP (> 1000 ng/L) was the best discriminator on who should be referred for 99mTc-PyP scan screening, with a sensitivity of 90% and a negative predictive value of 99%. CONCLUSION: The prevalence of ATTR-CA may be lower in a contemporary TAVR population due to its expanded indication for low-risk patients. NT-pro BNP is a simple test that can improve screening yield and more judiciously guide screening for ATTR-CA in this at-risk population. Comparison of the original versus the proposed algorithm.


Asunto(s)
Neuropatías Amiloides Familiares , Cardiomiopatías , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/epidemiología , Cardiomiopatías/diagnóstico por imagen , Prevalencia , Cintigrafía , Prealbúmina
6.
Catheter Cardiovasc Interv ; 102(6): 1149-1153, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855217

RESUMEN

Left ventricular outflow tract (LVOT) obstruction from the displaced prosthetic anterior mitral leaflet is a life-threatening complication that can occur during valve-in-valve (ViV) transcatheter mitral valve replacement (TMVR). Laceration of the anterior mitral leaflet to prevent outflow obstruction is a well-established transcatheter technique to mitigate the risk of LVOT obstruction in high-risk anatomies. In this report, we present a novel transseptal technique of prosthetic leaflet modification to prevent LVOT obstruction during ViV TMVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/prevención & control
7.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378620

RESUMEN

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Arritmias Cardíacas , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
8.
Am J Physiol Heart Circ Physiol ; 322(1): H94-H104, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34860593

RESUMEN

Dobutamine stress echocardiography (DSE) is a useful tool for assessing low-gradient significant aortic stenosis (AS) and contractile reserve (CR), but its prognostic utility has become controversial in recent studies. We evaluated the impact of DSE on aortic valve physiological, structural, and left ventricular parameters in low-gradient AS. Consecutive patients undergoing DSE for low-gradient AS evaluation from September 2010 to July 2016 were retrospectively studied, and DSE findings were divided into four groups: with and without severe AS and/or CR. Relationships between left ventricular chamber quantification, CR, aortic valve Doppler during DSE, and calcium score [by computerized tomography (CT)] were analyzed. There were 258 DSE studies performed on 243 patients, mean age 77.6 ± 10.8 yr and 183 (70.1%) were males. With increasing dobutamine dose, apart from systolic blood pressure, left ventricular ejection fraction, flow, cardiac power output, and longitudinal strain magnitude, along with aortic valve area and mean aortic gradient were all significantly increased (P < 0.05). Flow and mean gradient increased in both the presence and absence of CR, whereas stroke volume and aortic valve area increased mainly in those with CR only. The aortic valve area increased in both patients with low and high calcium scores; however, the baseline area was lower in those with a higher calcium score. During DSE, aortic valve area increases with increase in aortic valve gradient. Higher calcium score is associated with lower baseline aortic valve area, but the aortic valve area still increases with dobutamine even in presence of a high calcium score.NEW & NOTEWORTHY We show that even in most severe aortic stenosis, there is some residual valve pliability. This suggests that a complete loss of pliability is not compatible with survival.


Asunto(s)
Agonistas de Receptores Adrenérgicos beta 1/farmacología , Estenosis de la Válvula Aórtica/fisiopatología , Dobutamina/farmacología , Ecocardiografía/efectos adversos , Prueba de Esfuerzo/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Presión Sanguínea , Ecocardiografía/métodos , Prueba de Esfuerzo/métodos , Femenino , Corazón/efectos de los fármacos , Corazón/fisiopatología , Humanos , Masculino , Contracción Miocárdica , Volumen Sistólico
9.
Catheter Cardiovasc Interv ; 99(5): 1592-1596, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35066981

RESUMEN

We assessed the incidence of aortic valve surgery intervention in the treatment of infective endocarditis (IE) after transcatheter aortic valve replacement (TAVR) and compared the characteristics and outcomes of surgical intervention versus medical management alone in this cohort using a nationwide data set. We identified all the hospitalizations in patients undergoing TAVR who developed IE within 1-year (i.e., early IE) of the procedure from 2014 to 2017 using the Nationwide Readmission Database (NRD). The primary outcomes of the study were in-hospital mortality. A total of 906 hospitalizations were identified for IE amongst the TAVR patients from 2014 to 2017 of which 20 (2.21%) underwent aortic valve surgery during the hospitalization. Patients undergoing surgery were younger, more likely to have Staphylococcus aureus endocarditis, cardiogenic shock, and acute kidney injury (AKI) during the hospitalization. There were no significant differences in in-hospital mortality (9.9% vs. 12.4%, p = 0.824; adjusted odds ratio (aOR): 0.26 (0.01-1.58), p = 0.223) and 30-day readmissions. However, the length of stay and hospitalization costs were higher in surgical intervention group. The important predictors of in-hospital mortality in TAVR-related IE patients were dialysis during IE hospitalization, AKI, cardiogenic shock, Staphylococcus aureus endocarditis, stroke, and female sex. The utilization of surgical management for IE post-TAVR during the index hospitalization is low, and there is no significant mortality benefit with surgical intervention as compared with the medical management.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Infecciones Estafilocócicas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Endocarditis/diagnóstico , Endocarditis/cirugía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Masculino , Factores de Riesgo , Choque Cardiogénico/cirugía , Infecciones Estafilocócicas/complicaciones , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Artículo en Inglés | MEDLINE | ID: mdl-36511393

RESUMEN

BACKGROUND: The newest-generation balloon-expandable valve, SAPIEN 3 Ultra (S3U), is expected to function well with the enhanced sealing skirt compared with SAPIEN 3 (S3). However, current literature on the comparison between these two valves is limited to short-term follow-ups. Therefore, we aimed to evaluate the 1-year outcomes and echocardiographic changes of S3U compared with S3. METHODS: We retrospectively identified patients who underwent transfemoral-transcatheter aortic valve replacement with S3U or S3 (20/23/26 mm) at our institution in 2018-2020. Outcomes were 1-year clinical events and echocardiographic parameters, and were compared between S3U and S3 after adjustment with inverse probability of treatment weighting. RESULTS: The S3U and S3 groups included 297 (25.7%) and 858 (74.3%) patients, respectively. There were no significant differences between the two groups in clinical events (death 5.8% vs. 5.5%, hazard ratio [HR] 1.07, 95% confidence interval [CI] 0.81-1.90; death or heart failure hospitalization 10.3% vs. 10.1%, HR 1.04, 95% CI 0.67-1.62). The S3U group had a lower prevalence of mild paravalvular leakage (PVL) (13.7% vs. 22.3%, p = 0.044), with similar moderate PVL (0.7% vs. 1.2%, p > 0.99). No significant differences were observed in aortic valve mean gradient and Doppler velocity index at 1 year. However, the S3U group had a larger increase in mean gradient from implantation to 1 year (median +4.70 vs. +1.63 mmHg, p < 0.001). CONCLUSIONS: S3U and S3 carried similarly favorable clinical event risks. Nonetheless, S3U was associated with less frequent mild PVL but a larger increase in transprosthetic gradient. Further studies are needed to determine the prognostic impact of these hemodynamic differences.

11.
Catheter Cardiovasc Interv ; 99(3): 877-888, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34236762

RESUMEN

OBJECTIVES: This study aimed to evaluate the incidence, treatment, and outcomes of acute myocardial infarction (AMI) following transcatheter or surgical aortic valve replacement (TAVR or SAVR). BACKGROUND: Coronary artery disease is common in patients who undergo aortic valve replacement. However, little is known about differences in clinical features of post-TAVR or post-SAVR AMI. METHODS: We retrospectively identified post-TAVR or post-SAVR (including isolated and complex SAVR) patients admitted with AMI using the Nationwide Readmissions Database 2012-2017. Incidence, invasive strategy (coronary angiography or revascularization), and in-hospital outcomes were compared between post-TAVR and post-SAVR AMIs. RESULTS: The incidence of 180-day AMI was higher post-TAVR than post-SAVR (1.59% vs. 0.72%; p < 0.001). Post-TAVR AMI patients (n = 1315), compared with post-SAVR AMI patients (n = 1344), were older, had more comorbidities and more frequent non-ST-elevation AMI (NSTEMI: 86.6% vs. 78.0%; p < 0.001). After propensity-score matching, there was no significant difference in in-hospital mortality between post-TAVR and post-SAVR AMIs (14.7% vs. 16.1%; p = 0.531), but the mortality was high in both groups, particularly in ST-elevation AMI (STEMI: 38.8% vs. 29.2%; p = 0.153). Invasive strategy was used less frequently for post-TAVR AMI than post-SAVR AMI (25.6% vs. 38.3%; p < 0.001). Invasive strategy was associated with lower mortality in both post-TAVR (adjusted odds ratio = 0.40; 95% confidence interval = [0.24-0.66]) and post-SAVR groups (0.60 [0.41-0.88]). CONCLUSIONS: AMI, albeit uncommon, was more frequent post-TAVR than post-SAVR. Patients commonly presented with NSTEMI, but the mortality of STEMI was markedly high. Further studies are needed to understand why a substantial percentage of patients do not receive invasive coronary treatment, particularly after TAVR, despite seemingly better outcomes with invasive strategy.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Infarto del Miocardio con Elevación del ST , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Incidencia , Estudios Retrospectivos , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 100(5): 860-867, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36116028

RESUMEN

BACKGROUND: Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has emerged in recent years as a safe alternative to redo surgery in high-risk patients. Although early results are encouraging, data beyond short-term outcomes are lacking. Herein, we aimed to assess the 2-year outcomes after ViV-TAVI. METHODS: Patients undergoing ViV-TAVI for degenerated surgical valves between 2013 and 2019 at the Cleveland Clinic were reviewed. The coprimary endpoints were all-cause mortality and congestive heart failure (CHF) hospitalizations. We used time-to-event analyses to assess the primary outcomes. Further, we measured the changes in transvalvular gradients and the incidence of structural valve deterioration (SVD). RESULTS: One hundred and eighty-eight patients were studied (mean age = 76 years; 65% males). At 2 years of follow-up, all-cause mortality and CHF hospitalizations occurred in 15 (8%) and 28 (14.9%) patients, respectively. On multivariable analysis, the postprocedural length of stay was a significant predictor for both all-cause mortality (hazard ratio [HR] = 1.1; 95% confidence interval [CI]: 1.01, 1.19) and CHF hospitalization (HR = 1.16; 95% CI: 1.07, 1.27). However, the internal diameter of the surgical valve was not associated with significant differences in both primary endpoints. For hemodynamic outcomes, nine patients (4.8%) developed SVD. The mean and peak transvalvular pressure gradients remained stable over the follow-up period. CONCLUSION: ViV-TAVI for degenerated surgical valves was associated with favorable 2-year clinical and hemodynamic outcomes. Further studies are needed to better understand the role of ViV-TAVI as a treatment option in the life management of aortic valve disease.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Falla de Prótesis , Reoperación/métodos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/métodos
13.
Catheter Cardiovasc Interv ; 100(4): 575-584, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36073017

RESUMEN

BACKGROUND: Measures were undertaken at the Cleveland Clinic to reduce radiation exposure to patients and personnel working in the catheterization laboratories. We report our experience with these improved systems over a 7-year period in patients undergoing diagnostic catheterization (DC) and percutaneous coronary interventions (PCIs). METHODS: Patients were categorized into preinitiative (2009-2012) and postinitiative (2013-2019) groups in the DC and PCI cohorts. Propensity score matching was done between the pre- and postinitiative groups for both cohorts based on age, sex, body surface area, total fluoroscopy time, and total acquisition time. The effectiveness of radiation reduction measures was assessed by comparing the total air kerma (Ka,r ), and fluoroscopy- and acquisition-mode air kerma in patients in the two groups. RESULTS: In the DC cohort, there was a significant reduction in Ka,r in the postinitiative group in comparison to the preinitiative group (median, 396 vs. 857 mGy; p < 0.001). In the PCI cohort, Ka,r in the postinitiative group was 1265 mGy, which was significantly lower than the corresponding values in the preinitiative group (1994 mGy; p < 0.001). We also observed a significant reduction in fluoroscopy- and acquisition-based air kerma rates, and air kerma area product in the postinitiative group in comparison to the preinitiative group in both matched and unmatched DC and PCI cohorts after the institution of radiation reduction measures. CONCLUSION: There was a significant and sustained reduction in radiation exposure to patients in the catheterization laboratory with the implementation of advanced protocols. Similar algorithms can be applied in other laboratories to achieve a similar reduction in radiation exposure.


Asunto(s)
Intervención Coronaria Percutánea , Exposición a la Radiación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Fluoroscopía/efectos adversos , Fluoroscopía/métodos , Humanos , Laboratorios , Intervención Coronaria Percutánea/efectos adversos , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Estudios Retrospectivos , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 100(5): 810-820, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35916117

RESUMEN

BACKGROUND: The cerebral embolic protection (CEP) device captures embolic debris during transcatheter aortic valve replacement (TAVR). However, the impact of CEP on stroke severity following TAVR remains unclear. Therefore, we aimed to examine whether CEP was associated with reduced severity of stroke following TAVR. METHODS: This was a retrospective cohort study of 2839 consecutive patients (mean age: 79.2 ± 9.5 years, females: 41.5%) who underwent transfemoral TAVR at our institution between 2013 and 2020. We categorized patients into Sentinel CEP users and nonusers. Neuroimaging data were reviewed and the final diagnosis of a cerebrovascular event was adjudicated by a neurologist blinded to the CEP use or nonuse. We compared the incidence and severity (assessed by the National Institutes of Health Stroke Scale [NIHSS]) of stroke through 72 h post-TAVR or discharge between the two groups using stabilized inverse probability of treatment weighting (IPTW) of propensity scores. RESULTS: Of the eligible patients, 1802 (63.5%) received CEP during TAVR and 1037 (36.5%) did not. After adjustment for patient characteristics by stabilized IPTW, the rate of overall stroke was numerically lower in CEP users than in CEP nonusers, but the difference did not reach statistical significance (0.49% vs. 1.18%, p = 0.064). However, CEP users had significantly lower rates of moderate-or-severe stroke (NIHSS ≥ 6: 0.11% vs. 0.69%, p = 0.013) and severe stroke (NIHSS ≥ 15: 0% vs. 0.29%, p = 0.046). Stroke following CEP use (n = 8), compared with stroke following CEP nonuse (n = 15), tended to carry a lower NIHSS (median [IQR], 4.0 [2.0-7.0] vs. 7.0 [4.5-19.0], p = 0.087). Four (26.7%) out of 15 patients with stroke following CEP nonuse died within 30 days, with no death after stroke following CEP use. CONCLUSIONS: CEP use may be associated with attenuated severity of stroke despite no significant difference in overall stroke incidence compared with CEP nonuse. This finding is considered hypothesis-generating and needs to be confirmed in large prospective studies.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/epidemiología , Embolia Intracraneal/etiología , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
15.
Curr Cardiol Rep ; 24(12): 1917-1932, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36334213

RESUMEN

PURPOSE OF REVIEW: Transcatheter mitral valve replacement (TMVR) is an evolving and rapidly expanding field within structural interventions, offering renewed treatment options for patients with high-risk mitral valve disease. We aim to highlight and illustrate the importance of cardiac CT in the planning of TMVR. RECENT FINDINGS: As TMVR has evolved, so has the specific nuances of cardiac CT planning, we now understand the importance of accurate annular sizing and valve simulation to predict complications such as neo-LVOT obstruction and paravalvular leak (PVL). More so than any other modality, cardiac CT remains instrumental in accurately planning TVMR from feasibility, device sizing, access, and fluoroscopic angles. Cardiac CT remains the key modality in TMVR evaluation, often the first step in determining patient eligibility through comprehensive procedural planning as well as informing potential outcomes and prognosis. In this review, we discuss the critical role of cardiac computed tomography (CT) and the specific considerations involved in TMVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Obstrucción del Flujo Ventricular Externo/cirugía , Tomografía Computarizada por Rayos X , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones
16.
Catheter Cardiovasc Interv ; 97(3): 477-485, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32857915

RESUMEN

OBJECTIVE: We aimed to compare short-term outcomes between transcatheter aortic valve replacement (TAVR) for pure aortic regurgitation (AR) and TAVR for aortic stenosis (AS). BACKGROUND: In patients with severe pure AR for whom surgical valve replacement is infeasible, TAVR is sometimes used off-label. METHODS: Using the Nationwide Readmissions Database 2016-2017, we retrospectively identified patients without prior valve surgery who underwent endovascular TAVR. We compared in-hospital and 30-day outcomes according to the type of aortic valve disease. RESULTS: A total of 81,542 eligible patients were divided into the pure AR (n = 1,222, 1.50%), pure AS (n = 72,690, 89.1%), and AS + AR (n = 7,630, 9.36%) groups. In unadjusted analyses, the pure AR group, compared with the pure AS and AS + AR groups, showed a higher incidence of acute kidney injury (16.8% vs. 9.8% vs. 12.1%, respectively; p < .001) and need of surgical bailout (1.4% vs. 0.4% vs. 0.6%; p < .01). The pure AR group also showed higher in-hospital mortality than the pure AS group (2.4% vs. 1.4%; p = .005). After multivariable adjustment, TAVR for pure AR was significantly associated with a higher risk of acute kidney injury (odds ratio [OR] = 1.64, 95% confidence interval [CI] = 1.33-2.02; p < .001), cardiac tamponade (OR = 1.98, 95% CI = 1.00-3.92; p = .0498), and prolonged hospital stay (OR = 1.59, 95% CI = 1.29-1.95; p < .001) compared with TAVR for pure AS, whereas it was not significantly associated with in-hospital mortality (OR = 1.55, 95% CI = 0.99-2.45; p = .058) and other outcomes. CONCLUSIONS: TAVR may be a reasonable treatment option for selected patients with pure AR with regard to short-term outcomes. However, additional techniques or devices may be necessary to reduce periprocedural risk.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados Unidos/epidemiología
17.
Catheter Cardiovasc Interv ; 98(7): 1317-1331, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33205571

RESUMEN

OBJECTIVE: Determining the outcomes of transcatheter coil embolization (TCE) for several coronary artery lesions. BACKGROUND: TCE has been used as a treatment modality for various lesions in the coronary circulation. However, data on the efficacy and safety of TCE to treat coronary artery fistula (CAF), left internal mammary artery (LIMA) side-branch, coronary artery perforation (CAP), coronary artery aneurysm (CAA), and coronary artery pseudoaneurysm (CAPA) are limited. METHODS: We conducted a retrospective, descriptive analysis of all TCE devices in coronary lesions at our center from 2007 to 2019. Forty-one studied lesions included 25 CAF, 7 LIMA side-branch, 5 CAP, 2 CAA, and 2 CAPA. Short- and 1-year mortality and hospital readmission were reported, in addition to coil-related complications and procedural success. RESULTS: The utilization rate of TCE in coronary artery lesions at our center was found to be 33.8 per 100,000 percutaneous coronary intervention procedures over 12 years. Successful angiographic closure was achieved in 37 out of 41 (87.8%) cases (88, 100, 60, 100, and 100% of CAF, LIMA side-branch, CAP, CAA, and CAPA, respectively). No adverse events were directly related to TCE among the LIMA, CAA, and CAPA cases, and only one patient with CAF required reintervention at 3 months due to coil migration. CONCLUSIONS: Coil embolization in our institution was safe and effective in treating different coronary circulation abnormalities with a 87.8% overall success rate. Further study on the use of vascular plug devices in cases such as CAF or LIMA side-branch would be beneficial to understand the treatment options better.


Asunto(s)
Anomalías de los Vasos Coronarios , Embolización Terapéutica , Fístula , Angiografía Coronaria , Anomalías de los Vasos Coronarios/terapia , Embolización Terapéutica/efectos adversos , Fístula/terapia , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 97(3): 549-553, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32790144

RESUMEN

BACKGROUND: The use of transcatheter aortic valve replacement (TAVR) has expanded to patient populations of varying surgical risk in light of recent clinical trials, yet its role in patients with aortic stenosis and coexisting thoracic aortic aneurysm (TAA) is not well-delineated. We aimed to evaluate whether risk factors and in-hospital outcomes vary between TAVR patients with and without an unruptured TAA. METHODS: The Nationwide Readmissions Database was queried for patients hospitalized between January 2012 and December 2017 who underwent TAVR with and without an unruptured TAA. In-hospital outcomes were compared between cohorts after adjusting for sex, comorbidities, and TAVR approach, and in a subgroup analysis that excluded those with bicuspid aortic valves. RESULTS: Among 171,011 TAVR patients, 1,677 (1%) presented with TAA. Patients with TAA were younger (median age 80 vs. 82 years, p < .001) and more likely to have bicuspid aortic valves (9.3% vs. 0.9%, p < .001). Among patients with aneurysm, 2.6% died, 2.2% developed stroke, 1% developed aortic dissection, and 1.4% experienced cardiac tamponade while hospitalized. After adjusting for age, sex, bicuspid aortic valve, and all comorbidities, TAA was associated with significantly higher risk of post-TAVR aortic dissection (OR = 2.117, 95% CI [1.304-3.435], p = .002) and cardiac tamponade (OR = 1.682, 95% CI [1.1-2.572], p = .02). CONCLUSIONS: While the overall incidence of post-TAVR complications is low, patients with an unruptured TAA should be carefully considered by the Heart Team in weighing the additional risks of aortic dissection and cardiac tamponade after TAVR with those associated with surgery.


Asunto(s)
Aneurisma de la Aorta Torácica , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/epidemiología , Aneurisma de la Aorta Torácica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Humanos , Complicaciones Posoperatorias , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 97(2): 335-341, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32770712

RESUMEN

OBJECTIVES: This study sought to investigate the incidence and outcomes of surgical bailout (SB) after transcatheter mitral valve repair (TMVr) with MitraClip. BACKGROUND: TMVr poses a risk of serious procedural complications, possibly requiring urgent open surgery for SB. However, little is known about the risk of SB cases after TMVr. METHODS: We retrospectively identified patients who underwent TMVr using the Nationwide Readmissions Database 2014-2017. SB was defined as open thoracotomy for heart and aorta during the same hospitalization. Annual hospital volume was defined as the annual number of TMVr cases in each hospital in each year. RESULTS: Among 15,032 eligible patients, SB was required in 214 (1.42%), of whom 134 (62.6%) underwent mitral valve surgery (113 replacements; 21 repairs). The incidence of SB was decreasing significantly over the 4 years (5.26% in 2014; 0.43% in 2017; ptrend < .001). There was a significant nonlinear, inverse association of annual hospital volume with the incidence of SB. In-hospital death (15.0 vs. 2.1%; p < .001) and other in-hospital adverse events were significantly more frequent in patients with than without SB, whereas the 30-day readmission rate was similar (13.2 vs. 15.1%; p = .572). After adjustment for patient and hospital characteristics, SB was significantly associated with higher in-hospital mortality (odds ratio = 6.67, 95% confidence interval = 4.35, 10.23, p < .001). CONCLUSIONS: This study suggests that although the incidence of SB after TMVr is decreasing, SB is required more frequently in lower-volume hospitals and carries high in-hospital mortality. Further efforts are needed to understand the reasons for SB and improve outcomes in patients needing SB.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Incidencia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 98(3): E436-E443, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33512085

RESUMEN

BACKGROUND: Monitored anesthesia care (MAC) has become more widely used during transcatheter aortic valve replacement (TAVR) to avoid the complications of general anesthesia (GA). METHODS: We included consecutive patients who underwent transfemoral-TAVR at our institution between January 2012 and April 2017. We compared outcomes with GA versus MAC. RESULTS: Of 998 patients, MAC was used in 43.9%. MAC was associated with shorter procedural time (96.9 ± 30.9 vs. 135 ± 64.6 mins; p < .001), fluoroscopy time (20.4 ± 8.9 vs. 29 ± 18.7 mins; p < .001), lower contrast volume (45.5 ± 27 vs. 60.4 ± 43 cc; p < .001), and decreased radiation exposure (12,869 ± 8,099 vs. 20,630 ± 16,276 cGy-cm2 ; p < .001). Patients who underwent MAC had a briefer median (IQR) intensive care unit stay [23.3 (21-24) vs. 23.4 (20.8-26) hrs; p < .001], and hospital stay [2 (2, 3) vs. 3 (2-6) days; p < .001], and were more frequently discharged to home (93.4% vs. 82.9%; p < .001). MAC was associated with lower mortality at 30 days (0.5% vs. 2.9%; log-rank p = .012; adjHR 0.22, 95% CI 0.06-0.82; p = .024), but not at 1 year (11.7% vs. 14.6%; log-rank p = .157) or 3 years (36.8% vs. 38.4%; log-rank p = 0.433). There were no differences in major adverse cardiac and cerebrovascular events (MACCE) at either 30 days (4.6% vs. 9.3%; log-rank p = .14) or 1 year (21.1% vs. 21.5%; log-rank p = .653). Similar findings were seen among patients who received newer-generation SAPIEN-3 valves. CONCLUSION: Utilizing MAC and omitting intraprocedural transesophageal echocardiography during TAVR seems to be more efficient without compromising safety. Better TAVR outcomes can be achieved with newer generation valves without needing GA.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anestesia General/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Fluoroscopía , Humanos , Tiempo de Internación , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA