Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Europace ; 21(3): 434-439, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30010776

RESUMEN

AIMS: Vascular complications are the most common complications of atrial fibrillation (AF) ablation. Cryoballoon (CB) ablation for AF needs the insertion of a large 15 Fr sheath in the femoral vein. Our aim was to investigate the impact of vascular ultrasound (US) in guiding access and evaluating post-procedural subclinical complications in a large, multi-centre patient cohort that underwent CB ablation. METHODS AND RESULTS: A total cohort of 1435 consecutive patients were subdivided in 870 US -/-, 265 US -/+, and 300 US +/+ patients depending on US performance for: venipuncture guidance/post-procedural evaluation. Major clinical complications (requiring intervention and/or prolonged stay) were assessed. Irrespective of the clinical status, major US events were systematically determined in the subgroups with US evaluation 1 day post-procedure, if evidence of inadvertent artery puncture/cannulation (communication between artery and collection or artery-vein, regardless of the thrombosis state). Major clinical events were encountered in 1.7% (15/870), 1.1% (3/265), and 0% of patients in US -/-, US -/+, and US +/+ group, respectively (P = 0.02 between US -/- and US +/+ group). In the US -/- group, 5/10 (50%) of pseudo-aneurysms were diagnosed during readmission after a mean of 24 ± 11 days post-procedure. No delayed presentation was seen in the US -/+ group. Major US events during the US protocol post-procedure were seen in 3.8% (10/265) vs. 0.3% (1/300) of patients in US -/+ vs. US +/+ group, respectively, P = 0.004. CONCLUSION: US-guided venipuncture was associated with a near-to-zero risk of vascular complications in our patients undergoing CB ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Periférico , Criocirugía , Vena Femoral/diagnóstico por imagen , Ultrasonografía Intervencional , Enfermedades Vasculares/prevención & control , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Bélgica , Cateterismo Periférico/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Punciones , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/etiología
2.
Pacing Clin Electrophysiol ; 42(7): 868-873, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31037747

RESUMEN

BACKGROUND: In the setting of second-generation cryoballoon (CB2) ablation, left atrial (LA) access is generally achieved using a standard sheath (SS) that is exchanged for the 15Fr cryoballoon delivery sheath (CBS) and dilator over a long wire (CBS over-the-wire technique, CBS-W). Our objective was to evaluate the direct use of the CBS to gain LA access, by advancing the latter over the trans-septal needle (CBS over-the-needle technique, CBS-N), under transesophageal echocardiographic (TEE) guidance. METHODS: Consecutive patients who underwent CB2 ablation with the CBS-N technique were evaluated for feasibility of gaining LA access using TEE guidance and fluoroscopy views. Complications related to the LA access were compared with a matched CBS-W control group. Subanalysis (30 CBS-W vs 30 CBS-N patients) evaluated time-to-LA of the CBS: time from superior vena cava (with SS vs CBS) to LA insertion of the CBS, after exchange or directly, respectively. RESULTS: LA access could be achieved in all 505 patients of the CBS-N group, without technique modification or additional equipment. Challenging interatrial septa were noted in 13% of these patients: previous atrial septal defect repair (1%), hypermobile (10%), aneurysmal (1%), and abnormally thickened/fibrotic (1%). Incidence of complications was similar to the CBS-W group. Subanalysis showed a shorter time-to-LA in the CBS-N versus CBS-W group, 72 ± 46 seconds versus 293 ± 180 seconds, P < .001. CONCLUSIONS: Our study showed that the CBS-N technique is feasible and safe under echocardiographic guidance. Without sheath exchange, it simplifies the CB2 procedure, is less costly, time sparing, and might reduce the risk of air embolism.


Asunto(s)
Fibrilación Atrial/cirugía , Tabique Interatrial/cirugía , Oclusión con Balón/instrumentación , Criocirugía/instrumentación , Agujas , Venas Pulmonares/cirugía , Bélgica , Ecocardiografía , Estudios de Factibilidad , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Ultrasonografía Intervencional
3.
Europace ; 20(8): 1279-1286, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29016870

RESUMEN

Aims: To define predictors of complications of pulmonary vein isolation (PVI) and compare safety between different ablation techniques. Methods and results: One thousand patients with atrial fibrillation (AF) (age 60 ± 10, 72% males, CHA2DS2-VASc score 1 ± 1) underwent PVI using various techniques: conventional PVI (CPVI) using mapping with irrigated point-per-point RF ablation (n = 576), multi-electrode RF ablation with the pulmonary vein ablation catheter (PVAC) (n = 272) or high density mesh ablator (HDMA) (n = 59) and cryoballoon (CB) ablation (n = 93). A complication was defined as any procedure-related adverse event resulting in permanent injury or death, requiring intervention or treatment, or prolonging/requiring hospitalization for >48 h. A total of 105 (10.5%) complications occurred in 101 (10.1%) patients. No periprocedural death occurred. Most frequent complications were vascular complications (4%) and pericarditis (3.1%). Seven patients experienced permanent deficit due to PV stenosis (n = 3, 1 CPVI, 2 PVAC) (n = 3) and phrenic nerve palsy (PNP) (n = 4, 3 CPVI, 1 PVAC). Independent predictors of complications were female sex [odds ratio (OR) = 1.73; 95% confidence interval (CI) 1.08-2.79; P = 0.023], CHA2DS2-VASc score (OR = 1.24; 95% CI 1.01-1.52; P = 0.039), and ablation technique (P = 0.006) in multivariable-adjusted analysis. Among the different techniques, CB (P = 0.047) and PVAC ablation (P = 0.003) had lowest overall complication rates. Complication profile (type/severity) differed between techniques (association between CB and PNP, CPVI and pericardial injury, PVAC and transient ischaemic attack/PV stenosis). Conclusion: Overall complication rate of PVI with various techniques is 10.5%. Permanent deficit occurred only after PVAC and CPVI in 0.7% of patients. Female sex and a higher CHA2DS2-VASc score increase, while PVAC and CB-PVI decrease, overall risk. Differences in overall safety and individual complication profile make selection of the ablation technique in relation to clinical risk profile possible.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Bélgica/epidemiología , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Toma de Decisiones Clínicas , Comorbilidad , Criocirugía/instrumentación , Electrodos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/terapia , Prevalencia , Venas Pulmonares/fisiopatología , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento
4.
Eur Heart J Case Rep ; 5(12): ytab480, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34909574

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) has entrenched itself as one of the main approaches for the treatment of paroxysmal symptomatic atrial fibrillation (AF). Pulmonary vein isolation prevents focal triggers from pulmonary veins from initiating AF paroxysms. As standard-PVI is performed through the inferior vena cava (IVC) approach, through the femoral vein. However, there are conditions when this approach is not appropriate or is not available. CASE SUMMARY: We report a case of a 53-year-old male who was referred to Pauls Stradins Clinical University Hospital for PVI due to worsening AF. Due to the rare anatomical variant of the venous system, the standard approach to PVI could not be applied. Interrupted cava inferior did not allow for femoral vein and IVC access. We had to figure out a different path-a combination of internal jugular and subclavian veins was used. Transseptal puncture was performed under transoesophageal echocardiography (TOE) control with a puncture needle stiletto. Pulmonary veins were isolated successfully, no complications were observed, and the patient was discharged in sinus rhythm. DISCUSSION: In some patients, PVI cannot be done through the standard IVC approach. In such cases, a different venous access must be chosen. Our patient had a rare variant of interrupted IVC and we had to use superior vena cava approach for the procedure. The difficulty of this approach is that procedure instruments are not designed for non-standard venous access; however, a combined use of TOE, general anaesthesia, and contact force-guided ablation has succeeded in isolating patients' pulmonary veins.

5.
Anatol J Cardiol ; 20(5): 296-302, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30391969

RESUMEN

OBJECTIVE: The Latvian arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD-C) registry was established to determine the genetic background of ARVD-C for analyzing discovered genetic variation frequencies in the European and Latvian populations. METHODS: In total, 38 patients with suspected ARVD-C were selected. The clinical parameters were defined according to the ARVD-C guidelines, PKP2 and DSG2 gene analysis was performed using the Sanger sequencing. Additionally, large deletions/duplications were analyzed using the multiplex ligation-dependent probe amplification (MLPA) analysis. RESULTS: Twenty symptomatic patients were enrolled in the study. Typical ARVD abnormalities were found in electrocardiography for 10 (50%) patients, in Holter monitoring for 19 (95%), in transthoracic echocardiography for 20 (100%), and in cardiac magnetic resonance for 6 (30%). Different benign genetic variations were found. Three novel, unregistered, possibly benign variations were found in the PKP2 gene: c.2489+131G>A, c.2489+72delA, and c.1035-5T>C and three in the DSG2 gene: c.404G>A, c.1107G>A, and c.379-15A>G. Two genetic variations in the PKP2 gene: c.1592T>G, c.2489+1G>A are possibly pathogenic. For the first time, variation c.1592T>G, has been discovered in the homozygote form. Using the MLPA analysis, large deletions or duplications were not found. CONCLUSION: The prevalence of the majority of non-pathological genetic variations is similar in the Latvian ARVD-C patients and the European population. Possibly, pathogenic variations were found only in 10% of our registry patients, which could mean that PKP2 and DSG2 are not the most commonly affected genes in the Latvian population.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/genética , Cardiomiopatías/genética , Desmogleína 2/genética , Predisposición Genética a la Enfermedad , Placofilinas/genética , Adulto , Anciano , Displasia Ventricular Derecha Arritmogénica/diagnóstico por imagen , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Letonia , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Población Blanca/genética , Adulto Joven
6.
Int J Cardiol ; 253: 78-81, 2018 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-29196089

RESUMEN

BACKGROUND: Second generation cryoballoon (CB-A) ablation is highly effective in achieving pulmonary vein (PV) isolation and freedom from atrial fibrillation (AF). However, the ideal freezing strategy is still under debate. Our objective was to investigate the efficacy and outcome between different freezing strategies used with the CB-A in a multicenter, matched population. METHODS: From a total cohort of 1018 patients having undergone CB-A ablation for drug-refractory AF, 673 patients with follow-up ≥6months were included and stratified according to the applied freezing strategy: bonus freeze (BF) versus single freeze (SF). Final population of 256 BF patients was compared with 256 propensity-score matched SF patients. RESULTS: BF strategy consisted of 3 different protocols: 3cycles of 180s; 2cycles of 240s; and cycles of 240s followed by 180s in 99/256 (39%); 42/256 (16%); and 115/256 (45%) patients, respectively. SF approach included cycles of 240s in 23/256 (9%), and 180s in 233/256 (91%) patients. Electrical isolation could be achieved in all PVs by both protocols, with shorter procedure and fluoroscopy times in the SF group (mean 106 vs 65min, and 18 vs 14min, respectively, P<0.001). Phrenic nerve palsy persisted after discharge in a total of 11 patients (2.1%): 4 (1.6%) in the BF group vs 7 (2.7%) in the SF group, P=0.5. AF-free survival was similar between the 2 groups during follow-up (mean 18±10months) (log rank, P=0.6). CONCLUSIONS: CB-A ablation showed equal efficacy and outcome between SF and BF strategy.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Puntaje de Propensión , Anciano , Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter/normas , Estudios de Cohortes , Criocirugía/normas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA