RESUMEN
BACKGROUND: There is limited data on the organisation of paediatric echocardiography laboratories in Europe. METHODS: A structured and approved questionnaire was circulated across all 95 Association for European Paediatric and Congenital Cardiology affiliated centres. The aims were to evaluate: (1) facilities in paediatric echocardiography laboratories across Europe, (2) accredited laboratories, (3) medical/paramedical staff employed, (4) time for echocardiographic studies and reporting, and (5) training, teaching, quality improvement, and research programs. RESULTS: Respondents from forty-three centres (45%) in 22 countries completed the survey. Thirty-six centres (84%) have a dedicated paediatric echocardiography laboratory, only five (12%) of which reported they were European Association of Cardiovascular Imaging accredited. The median number of echocardiography rooms was three (range 1-12), and echocardiography machines was four (range 1-12). Only half of all the centres have dedicated imaging physiologists and/or nursing staff, while the majority (79%) have specialist imaging cardiologist(s). The median (range) duration of time for a new examination was 45 (20-60) minutes, and for repeat examination was 20 (5-30) minutes. More than half of respondents (58%) have dedicated time for reporting. An organised training program was present in most centres (78%), 44% undertake quality assurance, and 79% perform research. Guidelines for performing echocardiography were available in 32 centres (74%). CONCLUSION: Facilities, staffing levels, study times, standards in teaching/training, and quality assurance vary widely across paediatric echocardiography laboratories in Europe. Greater support and investment to facilitate improvements in staffing levels, equipment, and governance would potentially improve European paediatric echocardiography laboratories.
Asunto(s)
Cardiología , Ecocardiografía , Pediatría , Humanos , Ecocardiografía/normas , Ecocardiografía/estadística & datos numéricos , Europa (Continente) , Pediatría/educación , Encuestas y Cuestionarios , Cardiología/educación , Niño , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico , Mejoramiento de la CalidadRESUMEN
Previous omics research in patients with complex congenital heart disease and single-ventricle circulation (irrespective of the stage of palliative repair) revealed alterations in cardiac and systemic metabolism, inter alia abnormalities in energy metabolism, and inflammation, oxidative stress or endothelial dysfunction. We employed an affinity-proteomics approach focused on cell surface markers, cytokines, and chemokines in the serum of 20 adult Fontan patients with a good functioning systemic left ventricle, and we 20 matched controls to reveal any specific processes on a cellular level. Analysis of 349 proteins revealed 4 altered protein levels related to chronic inflammation, with elevated levels of syndecan-1 and glycophorin-A, as well as decreased levels of leukemia inhibitory factor and nerve growth factor-ß in Fontan patients compared to controls. All in all, this means that Fontan circulation carries specific physiological and metabolic instabilities, including chronic inflammation, oxidative stress imbalance, and consequently, possible damage to cell structure and alterations in translational pathways. A combination of proteomics-based biomarkers and the traditional biomarkers (uric acid, γGT, and cholesterol) performed best in classification (patient vs. control). A metabolism- and signaling-based approach may be helpful for a better understanding of Fontan (patho-)physiology. Syndecan-1, glycophorin-A, leukemia inhibitory factor, and nerve growth factor-ß, especially in combination with uric acid, γGT, and cholesterol, might be interesting candidate parameters to complement traditional diagnostic imaging tools and the determination of traditional biomarkers, yielding a better understanding of the development of comorbidities in Fontan patients, and they may play a future role in the identification of targets to mitigate inflammation and comorbidities in Fontan patients.
Asunto(s)
Biomarcadores , Proteínas Sanguíneas , Procedimiento de Fontan , Inflamación , Proteómica , Humanos , Adulto , Masculino , Inflamación/metabolismo , Femenino , Proteínas Sanguíneas/metabolismo , Procedimiento de Fontan/efectos adversos , Biomarcadores/sangre , Proteómica/métodos , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/metabolismo , Cardiopatías Congénitas/sangre , Cardiopatías Congénitas/patología , Fibrosis , Adulto Joven , Neovascularización Patológica/metabolismo , Estrés Oxidativo , AngiogénesisRESUMEN
Congenital LQTS is an often undetected inherited cardiac channel dysfunction and can be a reason for intrauterine fetal demise. It can present in utero as CTG and ultrasound abnormalities, i. e., bradycardia, ventricular tachycardia, or fetal hydrops. Diagnosis is made by CTG, echocardiography, or fMCG. Intrauterine therapy with a ß blocker and i. v. magnesium should be started. Our objective was to examine the current knowledge about diagnosis and treatment of LQTS and in particular to highlight the opportunity of vaginal birth under continuous intravenous magnesium therapy. Therefore, a thorough MEDLINE and Google Scholar search was conducted. Randomized controlled trials, meta-analyses, prospective and retrospective cohort trials, and case reports were considered. We showed the possibility of vaginal delivery under continuous magnesium therapy in a case of suspected fetal LQTS. A stepwise concept for diagnosis, monitoring, and peripartum management in low, intermediate, and high risk cases of fetal LQTS is presented. If risk is low or intermediate, a vaginal delivery under continuous monitoring is reasonable. Induction of labor at term should be evaluated.
Asunto(s)
Trabajo de Parto Inducido , Síndrome de QT Prolongado , Humanos , Femenino , Embarazo , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/terapia , Síndrome de QT Prolongado/tratamiento farmacológico , Recién Nacido , Adulto , Magnesio/administración & dosificación , Enfermedades Fetales/tratamiento farmacológico , Enfermedades Fetales/terapia , Enfermedades Fetales/diagnóstico , Parto Obstétrico , Atención Perinatal/métodosRESUMEN
OBJECTIVES: In children with congenital heart disease (CHD), excessive perioperative bleeding is associated with increased morbidity and mortality, thus making adequate perioperative hemostasis crucial. We investigate the prevalence of acquired von Willebrand syndrome type 2A (aVWS) in CHD and develop a treatment algorithm for patients with aVWS and CHD (TAPAC) to reduce perioperative blood loss. DESIGN: Retrospective cohort study. SETTING: Single-center study. PATIENTS: A total of 627 patients with CHD, undergoing corrective cardiac surgery between January 2008 and May 2017. INTERVENTIONS: The evaluation of perioperative bleeding risk was based on the laboratory parameters von Willebrand factor (VWF) antigen, ristocetin cofactor activity, platelet function analyzer (PFA) closure time adenosine diphosphate, and PFA epinephrine. According to the bleeding risk, treatment was performed with desmopressin or VWF. MEASUREMENTS AND MAIN RESULTS: aVWS was confirmed in 63.3 %, with a prevalence of 45.5% in the moderate and 66.3 % in the high-risk group. In addition, prevalence increased with ascending peak velocity above the stenosis (v max ) from 40.0% at less than or equal to 3 m/s to 83.3% at greater than 5 m/s. TAPAC reduced mean blood loss by 36.3% in comparison with a historical control cohort ( p < 0.001), without increasing the number of thrombotic or thromboembolic events during the hospital stay. With ascending v max , there was an increase in perioperative blood loss in the historical cohort ( p < 0.001), which was not evident in the TAPAC cohort ( p = 0.230). CONCLUSIONS: The prevalence of aVWS in CHD seems to be higher than assumed and leads to significantly higher perioperative blood loss, especially at high v max . Identifying these patients through appropriate laboratory analytics and adequate treatment could reduce blood loss effectively.
Asunto(s)
Cardiopatías Congénitas , Enfermedades de von Willebrand , Adenosina Difosfato , Algoritmos , Pérdida de Sangre Quirúrgica/prevención & control , Niño , Desamino Arginina Vasopresina/uso terapéutico , Epinefrina , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/cirugía , Humanos , Estudios Retrospectivos , Síndrome , Enfermedades de von Willebrand/complicaciones , Enfermedades de von Willebrand/terapia , Factor de von WillebrandRESUMEN
Fukutin encoded by FKTN is a ribitol 5-phosphate transferase involved in glycosylation of α-dystroglycan. It is known that mutations in FKTN affect the glycosylation of α-dystroglycan, leading to a dystroglycanopathy. Dystroglycanopathies are a group of syndromes with a broad clinical spectrum including dilated cardiomyopathy and muscular dystrophy. In this study, we reported the case of a patient with muscular dystrophy, early onset dilated cardiomyopathy, and elevated creatine kinase levels who was a carrier of the compound heterozygous variants p.Ser299Arg and p.Asn442Ser in FKTN. Our work showed that compound heterozygous mutations in FKTN lead to a loss of fully glycosylated α-dystroglycan and result in cardiomyopathy and end-stage heart failure at a young age.
Asunto(s)
Cardiomiopatía Dilatada , Distrofias Musculares , Cardiomiopatía Dilatada/genética , Cardiomiopatía Dilatada/metabolismo , Distroglicanos/genética , Distroglicanos/metabolismo , Glicosilación , Humanos , Proteínas de la Membrana/metabolismo , Músculo Esquelético/metabolismo , Distrofias Musculares/genética , Distrofias Musculares/metabolismo , MutaciónRESUMEN
About 50% of patients with arrhythmogenic cardiomyopathy (ACM) carry a pathogenic or likely pathogenic mutation in the desmosomal genes. However, there is a significant number of patients without positive familial anamnesis. Therefore, the molecular reasons for ACM in these patients are frequently unknown and a genetic contribution might be underestimated. Here, we used a next-generation sequencing (NGS) approach and in addition single nucleotide polymor-phism (SNP) arrays for the genetic analysis of two independent index patients without familial medical history. Of note, this genetic strategy revealed a homozygous splice site mutation (DSG2-c.378+1G>T) in the first patient and a nonsense mutation (DSG2-p.L772X) in combination with a large deletion in DSG2 in the second one. In conclusion, a recessive inheritance pattern is likely for both cases, which might contribute to the hidden medical history in both families. This is the first report about these novel loss-of-function mutations in DSG2 that have not been previously identi-fied. Therefore, we suggest performing deep genetic analyses using NGS in combination with SNP arrays also for ACM index patients without obvious familial medical history. In the future, this finding might has relevance for the genetic counseling of similar cases.
Asunto(s)
Displasia Ventricular Derecha Arritmogénica/genética , Desmogleína 2/genética , Hemicigoto , Homocigoto , Mutación con Pérdida de Función , Polimorfismo de Nucleótido Simple , Displasia Ventricular Derecha Arritmogénica/diagnóstico por imagen , Femenino , Humanos , MasculinoRESUMEN
Rare pediatric non-compaction and restrictive cardiomyopathy are usually associated with a rapid and severe disease progression. While the non-compaction phenotype is characterized by structural defects and is correlated with systolic dysfunction, the restrictive phenotype exhibits diastolic dysfunction. The molecular mechanisms are poorly understood. Target genes encode among others, the cardiac troponin subunits forming the main regulatory protein complex of the thin filament for muscle contraction. Here, we compare the molecular effects of two infantile de novo point mutations in TNNC1 (p.cTnC-G34S) and TNNI3 (p.cTnI-D127Y) leading to severe non-compaction and restrictive phenotypes, respectively. We used skinned cardiomyocytes, skinned fibers, and reconstituted thin filaments to measure the impact of the mutations on contractile function. We investigated the interaction of these troponin variants with actin and their inter-subunit interactions, as well as the structural integrity of reconstituted thin filaments. Both mutations exhibited similar functional and structural impairments, though the patients developed different phenotypes. Furthermore, the protein quality control system was affected, as shown for TnC-G34S using patient's myocardial tissue samples. The two troponin targeting agents levosimendan and green tea extract (-)-epigallocatechin-3-gallate (EGCg) stabilized the structural integrity of reconstituted thin filaments and ameliorated contractile function in vitro in some, but not all, aspects to a similar degree for both mutations.
Asunto(s)
Cardiomiopatías/genética , Mutación Missense , Miofibrillas/metabolismo , Troponina I/genética , Adenosina Trifosfatasas/metabolismo , Adulto , Calcio/metabolismo , Cardiomiopatías/metabolismo , Cardiomiopatías/patología , Catequina/análogos & derivados , Catequina/farmacología , Humanos , Lactante , Masculino , Microscopía Electrónica de Transmisión , Miofibrillas/efectos de los fármacos , Miofibrillas/ultraestructura , Sarcómeros/efectos de los fármacos , Sarcómeros/metabolismo , Índice de Severidad de la Enfermedad , Simendán/farmacología , Tropomiosina/metabolismo , Troponina I/metabolismoRESUMEN
Mutations in RBM20 encoding the RNA-binding motif protein 20 (RBM20) are associated with an early onset and clinically severe forms of cardiomyopathies. Transcriptome analyses revealed RBM20 as an important regulator of cardiac alternative splicing. RBM20 mutations are especially localized in exons 9 and 11 including the highly conserved arginine and serine-rich domain (RS domain). Here, we investigated in several cardiomyopathy patients, the previously described RBM20-mutation p.Pro638Leu localized within the RS domain. In addition, we identified in a patient the novel mutation p.Val914Ala localized in the (glutamate-rich) Glu-rich domain of RBM20 encoded by exon 11. Its impact on the disease was investigated with a novel TTN- and RYR2-splicing assay based on the patients' cardiac messenger RNA. Furthermore, we showed in cell culture and in human cardiac tissue that mutant RBM20-p.Pro638Leu is not localized in the nuclei but causes an abnormal cytoplasmic localization of the protein. In contrast the splicing deficient RBM20-p.Val914Ala has no influence on the intracellular localization. These results indicate that disease-associated variants in RBM20 lead to aberrant splicing through different pathomechanisms dependent on the localization of the mutation. This might have an impact on the future development of therapeutic strategies for the treatment of RBM20-induced cardiomyopathies.
Asunto(s)
Cardiomiopatías/genética , Mutación , Proteínas de Unión al ARN/genética , Adulto , Empalme Alternativo , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , LinajeRESUMEN
INTRODUCTION: Metabolomics studies are not routine when quantifying amino acids (AA) in congenital heart disease (CHD). OBJECTIVES: Comparative analysis of 24 AA in serum by traditional high-performance liquid chromatography (HPLC) based on ion exchange and ninhydrin derivatisation followed by photometry (PM) with ultra-high-performance liquid chromatography and phenylisothiocyanate derivatisation followed by tandem mass spectrometry (TMS); interpretation of findings in CHD patients and controls. METHODS: PM: Sample analysis as above (total run time, ~ 119 min). TMS: Sample analysis by AbsoluteIDQ® p180 kit assay (BIOCRATES Life Sciences AG, Innsbruck, Austria), which employs PITC derivatisation; separation of analytes on a Waters Acquity UHPLC BEH18 C18 reversed-phase column, using water and acetonitrile with 0.1% formic acid as the mobile phases; and quantification on a Triple-Stage Quadrupole tandem mass spectrometer (Thermo Fisher Scientific, Waltham, MA) with electrospray ionisation in the presence of internal standards (total run time, ~ 8 min). Calculation of coefficients of variation (CV) (for precision), intra- and interday accuracies, limits of detection (LOD), limits of quantification (LOQ), and mean concentrations. RESULTS: Both methods yielded acceptable results with regard to precision (CV < 10% PM, < 20% TMS), accuracies (< 10% PM, < 34% TMS), LOD, and LOQ. For both Fontan patients and controls AA concentrations differed significantly between methods, but patterns yielded overall were parallel. CONCLUSION: Serum AA concentrations differ with analytical methods but both methods are suitable for AA pattern recognition. TMS is a time-saving alternative to traditional PM under physiological conditions as well as in patients with CHD. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier NCT03886935, date of registration March 27th, 2019 (retrospectively registered).
Asunto(s)
Aminoácidos/sangre , Cromatografía Líquida de Alta Presión , Cardiopatías Congénitas/sangre , Cardiopatías Congénitas/diagnóstico , Ninhidrina , Espectrometría de Masas en Tándem , Biomarcadores , Estudios de Casos y Controles , Cromatografía Líquida de Alta Presión/métodos , Humanos , Metabolómica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodosRESUMEN
BACKGROUND: Various techniques are described to facilitate stable stent implantation in aortic arch stenosis or coarctation. We describe an alternative technique, which due to its unique appearance during stent implantation, we have named "Dog Bone Technique" (DBT). TECHNIQUE: The stent/balloon assembly is placed across the stenosis, the long sheath is retrieved to uncover the distal 20-50% of the stent. The balloon is inflated with the pressure inflator just to expand slightly the stent. Thereafter the sheath is pulled back and the proximal end is uncovered and partially inflated; therewith the assembly takes the typical "dog bone" shape before complete inflation and final positioning. Repositioning of the stent and control angiography is possible at each time of this procedure. RESULTS: Between 1/2010 and 12/2014 we implanted 91 stents in 87 patients (mean age 20.2 years). About 71 patients had native or re-coarctation and 16 patients had transverse aortic arch stenosis. In 38 patients (44%) a pharmacological exercise test with Orciprenaline was performed during implantation resulting in high-cardiac output. In none of the patients reduction of cardiac output by adenosine or a rapid pacing of the right ventricle was required for stable stent implantation. All stents were implanted in the targeted position using this single balloon technique. There were no acute or short-term complications detected. CONCLUSION: DBT is a safe and feasible technique for aortic stent implantation even at high-cardiac output. Other additional techniques for stent placement are not necessary to obtain a stable final position in the target region.
Asunto(s)
Angioplastia de Balón/métodos , Aorta Torácica , Coartación Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Stents , Adolescente , Adulto , Angiografía , Coartación Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto JovenRESUMEN
BACKGROUND: Various diseases and diversity in implantation ages, together with evolving diagnostic and therapeutic options, hinder comparative evaluations of long-term outcomes for valved conduits used for reconstruction of the right ventricular outflow tract (RVOT). We combined two common evaluation methods to optimally use information obtained by pooling the raw data from two high volume centers, each with very regular follow-up procedures, with the aim of analyzing durability differences between conventional homografts and bovine jugular veins. PATIENTS AND METHODS: In the period 1985 to 2012, a total of 444 bovine jugular veins and 267 homografts were implanted, and 6,738 postoperative examinations took place. Evaluations included age-stratified Kaplan-Meier analyses, Cox regression models, and time status graphs, the third showing age-group stratified, time-related frequencies of intact, insufficient, stenotic, both insufficient and stenotic, and postinterventional conduits below the freedom from explantation curve. They take into account interventions, explantations, and the nonterminal character of echocardiographic findings. RESULTS: The durability of intact bovine jugular veins in children and young adults is not inferior to that of homografts. Averaged over the first 12 years after implantation, the age groups < 25 years in fact showed advantages for bovine jugular vein recipients. The average fraction of patients younger than 25 years whose conduits were not explanted, postinterventional, stenotic, insufficient, or stenotic and insufficient was at least 10% higher in recipients of bovine jugular veins than in homograft recipients. CONCLUSION: According to the time status graphs, the use of bovine jugular veins for RVOT in patients younger than 25 years appears to lead to superior results when compared with cryopreserved homografts.
Asunto(s)
Bioprótesis , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Venas Yugulares/trasplante , Arteria Pulmonar/trasplante , Válvula Pulmonar/trasplante , Adolescente , Adulto , Factores de Edad , Aloinjertos , Animales , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/mortalidad , Bovinos , Niño , Preescolar , Remoción de Dispositivos , Femenino , Alemania , Supervivencia de Injerto , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Xenoinjertos , Hospitales de Alto Volumen , Humanos , Lactante , Recién Nacido , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto JovenRESUMEN
AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic condition caused predominantly by mutations within desmosomal genes. The mutation leading to ARVC-5 was recently identified on the island of Newfoundland and caused by the fully penetrant missense mutation p.S358L in TMEM43. Although TMEM43-p.S358L mutation carriers were also found in the USA, Germany, and Denmark, the genetic relationship between North American and European patients and the disease mechanism of this mutation remained to be clarified. METHODS AND RESULTS: We screened 22 unrelated ARVC patients without mutations in desmosomal genes and identified the TMEM43-p.S358L mutation in a German ARVC family. We excluded TMEM43-p.S358L in 22 unrelated patients with dilated cardiomyopathy. The German family shares a common haplotype with those from Newfoundland, USA, and Denmark, suggesting that the mutation originated from a common founder. Examination of 40 control chromosomes revealed an estimated age of 1300-1500 years for the mutation, which proves the European origin of the Newfoundland mutation. Skin fibroblasts from a female and two male mutation carriers were analysed in cell culture using atomic force microscopy and revealed that the cell nuclei exhibit an increased stiffness compared with TMEM43 wild-type controls. CONCLUSION: The German family is not affected by a de novo TMEM43 mutation. It is therefore expected that an unknown number of European families may be affected by the TMEM43-p.S358L founder mutation. Due to its deleterious clinical phenotype, this mutation should be checked in any case of ARVC-related genotyping. It appears that the increased stiffness of the cell nucleus might be related to the massive loss of cardiomyocytes, which is typically found in ventricles of ARVC hearts.
Asunto(s)
Displasia Ventricular Derecha Arritmogénica/genética , Núcleo Celular/fisiología , Proteínas de la Membrana/genética , Mutación Missense/genética , Adulto , Anciano , Displasia Ventricular Derecha Arritmogénica/etnología , Estudios de Cohortes , Femenino , Fibroblastos/fisiología , Efecto Fundador , Alemania/etnología , Haplotipos , Heterocigoto , Humanos , Masculino , Persona de Mediana Edad , Terranova y Labrador/etnología , Linaje , PielRESUMEN
INTRODUCTION: In the search for a biodegradable device that leaves nothing but the tissue of the patient after complete endotheliazation and absorption, the BioSTAR® device was introduced in 2007 (CE Mark in European community and HPB in Canada) for ASD and PFO closure. It consists of a metal framework covered by a biodegradable membrane generated from a layer of porcine collagen that is broken down and absorbed over time. In a sheep model, the results were promising, showing complete closure of the defect with degradation of approximately 90% of the implanted membrane material after two years. METHODS: We report a retrospective analysis of implantation failures, early and late complications in a series of 34 patients with 30 implanted BioStar® devices in a single center with a total follow-up of more than 75 patient years. RESULTS: We report 12% of implantation failures, 9% of early and 12% of late complications. Implantation failures include one embolized device, which was interventionally retrieved. Early complications were exclusively rhythm disturbances, one patient needed electrical and pharmacological therapy. Four relevant late complications occurred. One device required explantation after 61 days because of recurrent severe fever episodes, severe headache, and malaise that subsequently subsided after device removal. One patient presented with Dressler's syndrome with pericardial effusion 5 month after implantation requiring pericardiocentesis and steroid treatment. One device showed a central residual shunt that was not clearly seen initially. Finally, one device was explanted after hemorrhagic pericardial effusion due to perforation of an arm of the frame through the right atrial roof into the pericardial fold after 19 months. CONCLUSION: We conclude that implantation of the Biostar® device is difficult in patients with deficient aortic rims and early complications are similar to those seen in other devices. Of importance, the late complications seen with the Biostar® device might be attributable to specific material and immunological properties of the partially biodegradable device. Although a biodegradable device might theoretically be more favorable more efforts for optimization of these devices have to be taken.
Asunto(s)
Implantes Absorbibles , Cateterismo Cardíaco , Foramen Oval Permeable/terapia , Defectos del Tabique Interatrial/terapia , Implantación de Prótesis/efectos adversos , Dispositivo Oclusor Septal , Adolescente , Adulto , Niño , Preescolar , Estudios de Cohortes , Ecocardiografía Doppler/métodos , Femenino , Estudios de Seguimiento , Foramen Oval Permeable/diagnóstico por imagen , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Implantación de Prótesis/métodos , Estudios Retrospectivos , Medición de Riesgo , Insuficiencia del Tratamiento , Adulto JovenRESUMEN
Mitral valve stenosis caused by a discrete supravalvular membrane is a rare congenital malformation haemodynamically leading to significant mitral valve stenosis. When the supravalvular mitral stenosis consists of a discrete supravalvular membrane adherent to the mitral valve, it is usually not clearly detectable by routine echocardiography. We report about the typical echocardiographic finding in three young patients with this rare form of a discrete membranous supravalvular stenosis caused by a membrane adherent to the mitral valve. These cases present a typical echocardiographic feature in colour Doppler generated by the pathognomonic supramitral flow acceleration. Whereas typical supravalvular mitral stenosis caused by cor triatriatum or a clearly visible supravalvular ring is easily detectable by echocardiography, a discrete supravalvular membrane adjacent to the mitral valve leaflets resembling valvular mitral stenosis is difficult to differentiate by routine echocardiography. In our opinion, this colour phenomenon does resemble the visual impression of polar lights in the northern hemisphere; owing to its typical appearance, it may therefore be named as "Polar Light Sign". This phenomenon may help to detect this anatomical entity by echocardiography in time and therefore improve the prognosis for repair.
Asunto(s)
Ecocardiografía Doppler en Color , Estenosis de la Válvula Mitral/diagnóstico por imagen , Preescolar , Femenino , Humanos , Lactante , MasculinoRESUMEN
Importance: The ability to predict sudden cardiac death (SCD) in children and adolescents with hypertrophic cardiomyopathy (HCM) is currently inadequate. Late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR) imaging is associated with SCD events in adults with HCM. Objective: To examine the prognostic significance of LGE in patients with HCM who are younger than 21 years. Design, Setting, and Participants: This multicenter, retrospective cohort study was conducted from April 8, 2015, to September 12, 2022, in patients with HCM who were younger than 21 years and had undergone CMR imaging across multiple sites in the US, Europe, and South America. Observers of CMR studies were masked toward outcomes and demographic characteristics. Exposure: Natural history of HCM. Main Outcome and Measures: The primary outcome was SCD and surrogate events, including resuscitated cardiac arrest and appropriate discharges from an implantable defibrillator. Continuous and categorical data are expressed as mean (SD), median (IQR), or number (percentage), respectively. Survivor curves comparing patients with and without LGE were constructed by the Kaplan-Meier method, and likelihood of subsequent clinical events was further evaluated using univariate and multivariable Cox proportional hazards models. Results: Among 700 patients from 37 international centers, median (IQR) age was 14.8 (11.9-17.4) years, and 518 participants (74.0%) were male. During a median (IQR) [range] follow-up period of 1.9 (0.5-4.1) [0.1-14.8] years, 35 patients (5.0%) experienced SCD or equivalent events. LGE was present in 230 patients (32.9%), which constituted an mean (SD) burden of 5.9% (7.3%) of left ventricular myocardium. The LGE amount was higher in older patients and those with greater left ventricular mass and maximal wall thickness; patients with LGE had lower left ventricular ejection fractions and larger left atrial diameters. The presence and burden of LGE was associated with SCD, even after correcting for existing risk stratification tools. Patients with 10% or more LGE, relative to total myocardium, had a higher risk of SCD (unadjusted hazard ratio [HR], 2.19; 95% CI, 1.59-3.02; P < .001). Furthermore, the addition of LGE burden improved the performance of the HCM Risk-Kids score (before LGE addition: 0.66; 95% CI, 0.58-0.75; after LGE addition: 0.73; 95% CI, 0.66-0.81) and Precision Medicine in Cardiomyopathy score (before LGE addition: 0.68; 95% CI, 0.49-0.77; after LGE addition: 0.73; 95% CI, 0.64-0.82) SCD predictive models. Conclusions and Relevance: In this retrospective cohort study, quantitative LGE was a risk factor for SCD in patients younger than 21 years with HCM and improved risk stratification.
RESUMEN
PURPOSE: The clinical significance of collateral flow for the ventricular function of patients with univentricular hearts is often debated. This study evaluates the impact of collateral flow on respiration-dependent preload modification and diastolic function in Fontan patients assessed by systemic and pulmonary vein (PV) flow patterns. MATERIALS AND METHODS: Real-time phase-contrast cardiovascular magnetic resonance was performed in the right upper PV, ascending aorta, superior, and inferior vena cava (IVC) in 21 Fontan patients and 11 healthy individuals. The patients' respiratory cycle was divided into 4 periods to generate respiratory-dependent stroke volumes (SV i ). Conventional quantitative blood flow measurements were used to quantify and differentiate between low (group A) and high (group B) collateral flow. RESULTS: Group B showed significantly lower SV i IVC in inspiration, end-inspiration, expiration, and SV i ΔIVC compared with group A (23.6±4.8 mL/m 2 to 33.4±8.0; P =0.005). PV flow resulted in a lower mean SV i PV (11.6±7.6 mL/m 2 , vs. 14.0±11.4 mL/m 2 ) as well as a significantly lower peak systolic S-wave velocity (S max ) ( P =0.005), S/D-ratio (S max /peak diastolic wave velocity) ( P =0.015), and shorter diastolic deceleration time (DT D ; P =0.030; median DT D =134 ms) compared with group A (DT D =202 ms). CONCLUSIONS: This study demonstrates the incapability of Fontan patients to properly increase preload by inspiration in the presence of significant collateral flow. The results further show that collateral flow is associated with a volume-deprived ventricle and impaired diastolic function.
Asunto(s)
Procedimiento de Fontan , Humanos , Imagen por Resonancia Magnética/métodos , Ventrículos Cardíacos , Respiración , Espectroscopía de Resonancia Magnética , Velocidad del Flujo SanguíneoRESUMEN
Background: Cardiac magnetic resonance (CMR) imaging allows for multiparametric assessment of healthy pulmonary artery (PA) hemodynamics. Gender- and aging-associated PA stiffness and pressure alterations have remained clinically unestablished, however may demonstrate epidemiological differences in disease development. The aim of this study is to evaluate the role of CMR as a surrogate for catheter examinations by providing a comprehensive CMR assessment of sex- and age-related reference values for PA stiffness, flow, and pressure. Methods and Results: PA hemodynamics were studied between gender and age groups (>/<50 years) using phase-contrast CMR. Corresponding correlation analyses were performed. 179 healthy volunteers with a median age of 32.6 years (range 11.3-68.2) were examined. Males demonstrated increased PA compliance (median [interquartile range] or mean ± standard deviation) (20.8â mm2/mmHg [16.6; 25.8] vs. 19.2 ± 7.1â mm2/mmHg; P < 0.033), higher pulse wave velocity (2.00â m/s [1.35; 2.87] vs. 1.73â m/s [1.19; 2.34]; P = 0.018) and a reduced full width half maximum (FWHM) (219 ± 22â ms vs. 235 ± 23â ms; P < 0.001) than females. Mean, systolic, diastolic PA pressure and pulmonary proportional pulse pressure were significantly elevated for males compared to females (P < 0.001). Older subjects (>50 years) exhibited reduced PA elasticity (41.7% [31.0; 52.9] vs. 66.4% [47.7; 83.0]; P < 0.001), reduced PA compliance (15.4â mm2/mmHg [12.3; 20.7] vs. 21.3 ± 6.8â mm2/mmHg; P < 0.001), higher pulse wave velocity (2.59â m/s [1.57; 3.59] vs. 1.76â m/s [1.24; 2.34]; P < 0.001) and a reduced FWHM (218 ± 29â ms vs. 231 ± 21â ms; P < 0.001) than younger subjects. Conclusions: Velocity-time profiles are dependent on age and gender. PA stiffness indices deteriorate with age. CMR has potential to serve as a surrogate for right heart catheterization.
RESUMEN
Introduction: It is increasingly common to simultaneously determine a large number of metabolites in order to assess the metabolic state of, or clarify biochemical pathways in, an organism ("metabolomics"). This approach is increasingly used in the investigation of the development of heart failure. Recently, the first reports with respect to a metabolomic approach for the assessment of patients with complex congenital heart disease have been published. Classical statistical analysis of such data is challenging. Objective: This study aims to present an alternative to classical statistics with respect to identifying relevant metabolites in a classification task and numerically estimating their relative impact. Methods: Data from two metabolomic studies on 20 patients with complex congenital heart disease and Fontan circulation and 20 controls were reanalysed using random forest (RF) methodology. Results were compared to those of classical statistics. Results: RF analysis required no elaborate data pre-processing. The ranking of the variables with respect to classification impact (subject diseased, or not) was remarkably similar irrespective of the evaluation method used, leading to identical clinical interpretation. Conclusion: In metabolomic classification in adult patients with complex congenital heart disease, RF analysis as a one-step method delivers the most adequate results with minimum effort. RF may serve as an adjunct to traditional statistics also in this small but crucial-to-monitor patient group.
RESUMEN
BACKGROUND: Parameters of the interaction of the left atrium and left ventricle, atrioventricular (AV) coupling, are used in the diagnosis and follow-up of diastolic dysfunction in adults. Pediatric parameters of AV coupling have not been evaluated so far. The aim of this multicenter study was to investigate parameters of AV coupling in a large cohort of healthy infants and children using noninvasive real-time three-dimensional echocardiography. The authors hypothesized that the contribution of the different left atrial (LA) volumes to left ventricular (LV) stroke volume differs over a range of different heart rates. METHODS: Three-dimensional echocardiographic data sets from 332 subjects (ages 0 days to 18.5 years) were analyzed prospectively. Volume-time curves of the left atrium and left ventricle were generated. Conduit volume was calculated and percentiles were established by the lambda-mu-sigma method of Cole and Green. Contributions of active, passive, and conduit volume to LV filling were measured and related to heart rate by linear regression. LV and LA peak filling rates (PFR) and peak emptying rates (PER) and time to PFR and PER normalized to the R-R interval (PFRt[%] and PERt[%]) were measured and correlated to each other. RESULTS: Conduit volume increased with body surface area. The contribution of LA active emptying to LV filling tended to increase with decreasing heart rate, while the contribution of passive emptying decreased. Conduit volume contributed most to LV filling (median, 57.58 %; interquartile range, 12.85%) with a tendency to increase with decreasing heart rate. Close diastolic AV coupling was demonstrated by virtually identical LV PFRt(%) and LA PERt(%) during diastole. LV PERt(%) occurred earlier than LA PFRt(%), showing less coupling during systole. LV PFRt(%) and LA PERt(%) were strongly correlated to heart rate (r = 0.76 and r = 0.73, respectively). Lower heart rate resulted in a prolongation of diastole after LV PFR. CONCLUSIONS: Assessment of conduit volume and AV coupling by three-dimensional echocardiography is feasible in infants and children. The references of this study can serve as a basis to further investigate the role of parameters of AV coupling in pediatric patients with heart diseases concerning diastolic and LA function.