Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 175
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 120(43): e2304826120, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37844251

RESUMEN

Future food farming technology faces challenges that must integrate the core goal of keeping the global temperature increase within 1.5 °C without reducing food security and nutrition. Here, we show that boosting the production of insects and earthworms based on food waste and livestock manure to provide food and feed in China will greatly contribute to meeting the country's food security and carbon neutrality pledges. By substituting domestic products with mini-livestock (defined as earthworms and insects produced for food or feed) protein and utilizing the recovered land for bioenergy production plus carbon capture and storage, China's agricultural sector could become carbon-neutral and reduce feed protein imports to near zero. This structural change may lead to reducing greenhouse gas emissions by 2,350 Tg CO2eq per year globally when both domestic and imported products are substituted. Overall, the success of mini-livestock protein production in achieving carbon neutrality and food security for China and its major trading partners depends on how the substitution strategies will be implemented and how the recovered agricultural land will be managed, e.g., free use for afforestation and bioenergy or by restricting this land to food crop use. Using China as an example, this study also demonstrates the potential of mini-livestock for decreasing the environmental burden of food production in general.


Asunto(s)
Ganado , Eliminación de Residuos , Animales , Efecto Invernadero , Alimentos , Carbono , Biodiversidad , Temperatura , Agricultura , Seguridad Alimentaria , China
2.
Nature ; 562(7728): 519-525, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30305731

RESUMEN

The food system is a major driver of climate change, changes in land use, depletion of freshwater resources, and pollution of aquatic and terrestrial ecosystems through excessive nitrogen and phosphorus inputs. Here we show that between 2010 and 2050, as a result of expected changes in population and income levels, the environmental effects of the food system could increase by 50-90% in the absence of technological changes and dedicated mitigation measures, reaching levels that are beyond the planetary boundaries that define a safe operating space for humanity. We analyse several options for reducing the environmental effects of the food system, including dietary changes towards healthier, more plant-based diets, improvements in technologies and management, and reductions in food loss and waste. We find that no single measure is enough to keep these effects within all planetary boundaries simultaneously, and that a synergistic combination of measures will be needed to sufficiently mitigate the projected increase in environmental pressures.


Asunto(s)
Agricultura/métodos , Agricultura/tendencias , Ambiente , Abastecimiento de Alimentos , Desarrollo Sostenible , Cambio Climático , Productos Agrícolas/metabolismo , Nitrógeno/metabolismo , Fósforo/metabolismo , Incertidumbre
3.
Ear Hear ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38915137

RESUMEN

OBJECTIVES: A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN: A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS: Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS: A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.

4.
Eur Arch Otorhinolaryngol ; 281(2): 1057-1060, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38001386

RESUMEN

BACKGROUND: Electrode migration has been identified as a complication primarily related to straight electrodes. To address this issue, the use of a fixation clip has been suggested as an alternative to stabilize the electrode lead and reduce the risk of migration. METHODS: A modified approach to the standard fixation clip procedure is introduced. Steps and technical considerations are presented in the video attached. CONCLUSIONS: This novel configuration offers enhanced fixation of the electrode array without requiring additional surgical time and without posing any additional risk to the facial nerve.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Cóclea/cirugía , Electrodos Implantados , Instrumentos Quirúrgicos
5.
Artículo en Inglés | MEDLINE | ID: mdl-38668790

RESUMEN

PURPOSE: The aim of this study was to translate and validate the "Music-Related Quality of Life Questionnaire" into Spanish (sMuRQoL) and assess its convergent validity and discriminative capacity by comparing its scores with the outcomes of the musical perception test Meludia. METHODS: The sMuRQoL was completed by 129 patients: 55 cochlear implant (CI) users and 74 normal hearing (NH) individuals. Conducted in this study were an exploratory factor analysis, an evaluation of internal consistency, an assessment of score stability through test-retest reliability, a comparison of sMuRQoL scores between CI users and NH individuals and an examination of potential evidence of convergent validity and discriminative capacity of sMuRQoL in relation to other tools. This involved the comparison of the questionnaire scores with the Meludia outcomes. RESULTS: The sMuRQoL demonstrated a two-dimensional structure. All the dimensions displayed high internal consistency (α = 0.879-0.945) and score stability (ICC = 0.890-0.942). There were significant differences in the Frequency test between NH and CI users (d = 1.19-1.45). There's evidence of convergent validity between the scores of the Frequency test and the results of Meludia (r = 0.242-0.645). Additionally, the Frequency test demonstrate a good discriminative capacity to identify patients with poorer musical perception. CONCLUSIONS: The sMuRQoL is a reliable questionnaire, with adequate evidence of validity based on internal structure. This study provides an accessible, cost-effective, and quick-to-administer instrument in Spanish, optimizing available healthcare resources and bringing us closer to the patient needs.

6.
Eur Arch Otorhinolaryngol ; 281(4): 2031-2035, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38367073

RESUMEN

PURPOSE: Achromobacter xylosoxidans is an emerging pathogen mainly associated with resistant nosocomial infections. This bacteria had been isolated in the ear together with other pathogens in cultures from patients with chronic otitis media, but it had never been reported as a cause of osteomyelitis of the external auditory canal. CASE PRESENTATION: We present a unique case of a healthy 81-year-old woman who presented with left chronic otorrhea refractory to topical and oral antibiotic treatment. Otomicroscopy revealed an erythematous and exudative external auditory canal (EAC) with scant otorrhea. The tympanic membrane was intact, but an area of bone remodeling with a small cavity anterior and inferior to the bony tympanic frame was observed. Otic culture isolated multi-drug-resistant A. xylosoxidans, only sensitive to meropenem and cotrimoxazole. Temporal bone computed tomography showed an excavation of the floor of the EAC compatible with osteomyelitis. Targeted antibiotherapy for 12 weeks was conducted, with subsequent resolution of symptoms and no progression of the bone erosion. CONCLUSIONS: Atypical pathogens such as A. xylosoxidans can be the cause of chronic otitis externa. Early diagnosis and specific antibiotherapy can prevent the development of further complications, such as osteomyelitis. In these cases, otic cultures play an essential role to identify the causal germ. This is the first case of EAC osteomyelitis due to A. xylosoxidans reported to date.


Asunto(s)
Achromobacter denitrificans , Enfermedades del Oído , Osteomielitis , Otitis Externa , Femenino , Humanos , Anciano de 80 o más Años , Conducto Auditivo Externo/diagnóstico por imagen , Otitis Externa/diagnóstico , Otitis Externa/tratamiento farmacológico , Osteomielitis/diagnóstico , Osteomielitis/tratamiento farmacológico , Osteomielitis/complicaciones
7.
Eur Arch Otorhinolaryngol ; 281(2): 629-638, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37480418

RESUMEN

PURPOSE: Music perception is one of the greatest challenges for cochlear implant (CI) users. The aims of this study were: (i) to evaluate the music perception of CI users using the online Meludia music training program as music testing platform, (ii) to compare performance among three age groups, and (iii) to compare CI users with their normal hearing (NH) peers. METHODS: 138 individuals participated, divided between children (6-10 y), adolescents (11-16 y), and adults (≥ 17 y). Five music perception tasks were evaluated: Rhythm, Spatialization, Stable/unstable, Melody, and Density. We also administered the music related quality of life (MuRQoL) questionnaire for adults, and a music questionnaire for pediatric population (6-16 y) (MuQPP). RESULTS: A significantly higher percentage of the adolescent CI users completed the five tasks compared to the other age groups. Both pediatric and adolescent CI users had similar performance to their NH peers in most categories. On the MuRQoL, adult NH listeners reported more music exposure than CI users (3.8 ± 0.6 vs 3.0 ± 0.6, p < 0.01), but both groups reported similar levels of perceived music importance (3.4 ± 0.7 vs 3.2 ± 1.1, p = 0.340). On the MuQPP, pediatric CI users who scored highly on music perception also had higher reported questionnaire scores (54.2 ± 12.9 vs 40.9 ± 12.1, p = 0.009). CONCLUSIONS: Meludia can be used to evaluate music perception and to use for music training in CI users of all ages. Adolescents had the highest performance in most musical tasks. Pediatric CI users were more similar to their NH peers. The importance of music in adult CI users was comparable to their NH peers.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Música , Adolescente , Adulto , Niño , Humanos , Calidad de Vida , Percepción
8.
Eur Arch Otorhinolaryngol ; 281(2): 673-682, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37535079

RESUMEN

PURPOSE: The clinician-graded electronic facial paralysis assessment (eFACE) is a relatively new digital tool for assessing facial palsy. The present study aimed to determine the validity and reliability of the Spanish version of the eFACE. METHODS: Forward-backward translation from the original English version was performed. Videos and photographs from 65 adult patients with unilateral facial paralysis (any severity, time course, and etiology) were evaluated twice by five otolaryngologists with varying levels of experience in facial palsy evaluation. Internal consistency was measured using Cronbach's α and the intra- and inter-rater reliability were measured using intraclass correlation coefficient. Concurrent validity was established by calculating Spearman's rho correlation (ρ) between the eFACE and the House-Brackmann scale (H-B) and Pearson's correlation (r) between the eFACE and the Sunnybrook Facial Grading System (SFGS). RESULTS: The Spanish version of the eFACE showed good internal consistency (Cronbach's α > 0.8). The intra-rater reliability was nearly perfect for the total score (intraclass correlation coefficient: 0.95-0.99), static score (0.92-0.96), and dynamic score (0.96-0.99) and important-to-excellent for synkinesis score (0.79-0.96). The inter-rater reliability was excellent for the total score (0.85-0.93), static score (0.80-0.90), and dynamic score (0.90-0.95) and moderate-to-important for the synkinesis score (0.55-0.78). The eFACE had a very strong correlation with the H-B (ρ = - 0.88 and - 0.85 for each evaluation, p < 0.001) and the SFGS (r = 0.92 and 0.91 each evaluation, p < 0.001). CONCLUSION: The Spanish version of the eFACE is a reliable and valid instrument for assessment of facial function in the diagnosis and treatment of patients with facial paralysis.


Asunto(s)
Parálisis de Bell , Parálisis Facial , Sincinesia , Adulto , Humanos , Parálisis Facial/cirugía , Reproducibilidad de los Resultados , Cara , Electrónica
9.
Artículo en Inglés | MEDLINE | ID: mdl-38573516

RESUMEN

PURPOSE: To study outcome after cochlear implantation using the Cochlear Implant (CI) outcome assessment protocol based on the International Classification of Functioning, Disability and Health (ICF) model (CI-ICF). METHODS: Raw data of a prospective, longitudinal, multicenter study was analyzed. Seventy-two CI candidates were assessed preoperatively and six months postoperatively using the CI-ICF protocol. Following tools were used: (1) Work Rehabilitation Questionnaire (WORQ), (2) Abbreviated Profile of Hearing Aid Benefit (APHAB), (3) Audio Processor Satisfaction Questionnaire (APSQ), (4) Speech, Spatial, and Qualities of Hearing Scale (SSQ12), (5) Hearing Implant Sound Quality Index (HISQUI19), (6) Nijmegen CI Questionnaire (NCIQ) (7) pure tone audiometry, (8) speech audiometry, (9) sound localization. RESULTS: There was a significant improvement of speech discrimination in quiet (p = 0.015; p < 0.001) and in noise (p = 0.041; p < 0.001), sound detection (p < 0.001), tinnitus (p = 0.026), listening (p < 0.001), communicating with-receiving-spoken messages (p < 0.001), conversation (p < 0.001), family relationships (p < 0.001), community life (p = 0.019), NCIQ total score and all subdomain scores (p < 0.001). Subjective sound localization significantly improved (p < 0.001), while psychometric sound localization did not. There was no significant subjective deterioration of vestibular functioning and no substantial change in sound aversiveness. CI users reported a high level of implant satisfaction postoperatively. CONCLUSION: This study highlights the positive impact of cochlear implantation on auditory performance, communication, and subjective well-being. The CI-ICF protocol provides a holistic and comprehensive view of the evolution of CI outcomes.

10.
Eur Arch Otorhinolaryngol ; 280(2): 543-548, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35737100

RESUMEN

PURPOSE: The Sunnybrook facial grading system (SFGS) is one of the most widely employed tools to assess facial function. The present study aimed to determine the validity and reliability of the Spanish language version of the SFGS. METHODS: Forward-backward translation from the original English version was performed by fluent speakers of English and Spanish. Videos from 65 patients with facial paralysis (FP) were evaluated twice by five otolaryngologists with experience in FP evaluation. Internal consistency and intra- and inter-rater reliability were assessed. The House-Brackmann scale was used to display concurrent validity which was established by Spearman's rho correlation. RESULTS: The Cronbach's α score exceeded 0.70. The intra-rater intraclass correlation coefficient (ICC) was nearly perfect for the composite score (0.96-0.99), voluntary movements (0.97-0.99), and synkinesis (0.91-0.98), and important to almost perfect for symmetry at rest (0.79-0.97). In both evaluations, the inter-rater ICC was higher than 0.90 for the composite score (0.92-0.96) and voluntary movements (0.91-0.96) and slightly lower for symmetry at rest (0.66-0.85) and synkinesis (0.72-0.87). A strong negative correlation was found between the H-B scale and SFGS (Spearman's rho coefficient = - 0.92, p < 0.001) in both evaluations. CONCLUSION: The Spanish version of the SFGS is a reliable and valuable instrument for the assessment of facial function in the diagnosis and treatment of patients with FP.


Asunto(s)
Parálisis Facial , Sincinesia , Humanos , Reproducibilidad de los Resultados , Cara , Parálisis Facial/diagnóstico , Lenguaje
11.
J Environ Manage ; 337: 117732, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-36944291

RESUMEN

Ammonia (NH3) volatilization, nitrous oxide (N2O) emissions, and nitrate (NO3-) leaching from agriculture cause severe environmental hazards. Research studies and mitigation strategies have mostly focused on one of these nitrogen (N) losses at a time, often without an integrated view of the agro-food system. Yet, at the regional scale, N2O, NH3, and NO3- loss patterns reflect the structure of the whole agro-food system. Here, we analyzed at the resolution of NUTS2 administrative European Union (EU) regions, N fluxes through the agro-food systems of a Temperate-Mediterranean gradient (France, Spain, and Portugal) experiencing contrasting climate and soil conditions. We assessed the atmospheric and hydrological N emissions from soils and livestock systems. Expressed per ha agricultural land, NH3 volatilization varied in the range 6.2-44.4 kg N ha-1 yr-1, N2O emission and NO3 leaching 0.3-4.9 kg N ha-1 yr-1 and 5.4-154 kg N ha-1 yr-1 respectively. Overall, lowest N2O emission was found in the Mediterranean regions, where NO3- leaching was greater. NH3 volatilization in both temperate and Mediterranean regions roughly follows the distribution of livestock density. We showed that these losses are also closely correlated with the level of fertilization intensity and agriculture system specialization into either stockless crop farming or intensive livestock farming in each region. Moreover, we explored two possible future scenarios at the 2050 horizon: (1) a scenario based on the prescriptions of the EU-Farm-to-Fork (F2F) strategy, with 25% of organic farming, 10% of land set aside for biodiversity, 20% reduction in N fertilizers, and no diet change; and (2) a hypothetical agro-ecological (AE) scenario with generalized organic farming, reconnection of crop and livestock farming, and a healthier human diet with an increase in the share of vegetal protein to 65% (i.e., the Mediterranean diet). Results showed that the AE scenario, owing to its profound reconfiguration of the entire agro-food system would have the potential for much greater reductions in NH3, N2O, and NO3- emissions, namely, 60-81% reduction, while the F2F scenario would only reach 24-35% reduction of N losses.


Asunto(s)
Agricultura , Nitrógeno , Humanos , Nitrógeno/análisis , Agricultura/métodos , Suelo/química , Amoníaco/análisis , Granjas , Fertilizantes , Óxido Nitroso/análisis
12.
Eur Arch Otorhinolaryngol ; 279(10): 4745-4759, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35044508

RESUMEN

PURPOSE: (a) To measure the change in cognition, the improvement of speech perception, and the subjective benefit in people under and over 60 years following cochlear implantation. (b) To assess the relationship between cognition, demographic, audiometric, and subjective outcomes in both age groups. METHODS: 28 cochlear implant (CI) users were assigned to the < 60y group and 35 to the ≥ 60y group. Cognition was measured using the Repeatable Battery for the Assessment of Neuropsychological Status for Hearing impaired individuals (RBANS-H); subjective benefit was measured using the Nijmegen Cochlear Implant Questionnaire (NCIQ); the Glasgow Benefit Inventory (GBI); the Hearing Implant Sound Quality Index (HISQUI19); Speech, Spatial and Qualities of Hearing Scale (SSQ12); and the Hospital Anxiety and Depression Scale (HADS). RESULTS: Prior to surgery: the RBANS-H total score positively correlated with the domains "Advanced sound", "Self-esteem", and "Social functioning" of NCIQ, and negatively with HADS scores. 12 months post-implantation: the RBANS-H total score increased in the < 60y (p = 0.038) and in the ≥ 60y group (p < 0.001); speech perception and subjective outcomes also improved; RBANS-H total score positively correlated with "Self-esteem" domain in NCIQ. Age and the RBANS-H total score correlated negatively in the ≥ 60y group (p = 0.026). CONCLUSIONS: After implantation, both age groups demonstrated improved cognition, speech perception and quality of life. Their depression scores decreased. Age was inversely associated with cognition.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Disfunción Cognitiva , Pérdida Auditiva , Percepción del Habla , Anciano , Implantación Coclear/psicología , Disfunción Cognitiva/etiología , Pérdida Auditiva/psicología , Pérdida Auditiva/cirugía , Humanos , Calidad de Vida/psicología , Resultado del Tratamiento
13.
Audiol Neurootol ; 26(1): 27-34, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32599597

RESUMEN

BACKGROUND: Facial nerve tumors (FNTs) are relatively rare benign lesions that arise from any segment of the facial nerve (FN). About half of all patients present with FN dysfunction, mainly long-standing or progressive facial paralysis. Diagnosis of an FNT is usually based on radiological imaging and confirmed by histological study. Most reported cases of FNTs are schwannomas and hemangiomas. OBJECTIVES: The aim of this study was to review 4 cases of lesions with clinical, radiological, and surgical findings that suggested an FNT, the pathology revealing a fibrovascular proliferation with no clear signs of a specific tumor. METHOD: Medical records of patients who had surgery due to an FN lesion were reviewed. Cases with known tumoral lesions were excluded. Four patients with tumor-like lesions were identified. Their imaging studies were re-evaluated. The pathological study included hematoxylin-eosin, Masson's trichrome, and immunohistochemistry for S100 protein, neurofilaments, CD31, Wilms' tumor 1 (WT1), and D240. RESULTS: The 4 cases revealed tumor-like fibrovascular lesions that could not be classified as typical pathological entities. All cases had a complete facial palsy preoperatively. Computed tomography and magnetic resonance imaging (MRI) suggested schwannoma or hemangioma. A complete excision was achieved, and a facial reconstruction was performed immediately after interruption. Postoperative FN function was improved in all cases. The histological study showed nervous tracts of normal morphology, with fibrous and vascular tissue interspersed in variable proportions. All cases showed areas of fibrosis with Masson's stain. In all cases, nervous tissue and Schwann cells tested positively for neurofilaments and S100, respectively. In vascular areas, endothelial cells stained positively for CD31, and negatively for D240 and WT1. CONCLUSIONS: Fibrovascular lesions of the FN may mimic primary FNTs, especially schwannomas and hemangiomas. Surgical excision with grafting or nerve transfer is the procedure of choice if a complete facial paralysis is found. This unusual condition should be considered when counseling patients with FN lesions. The lack of hyperintensity on MRI T2-weighted images may suggest the presence of fibrous tissue.


Asunto(s)
Neoplasias de los Nervios Craneales/diagnóstico , Diagnóstico Diferencial , Enfermedades del Nervio Facial/diagnóstico , Nervio Facial/diagnóstico por imagen , Parálisis Facial/fisiopatología , Fibrosis/diagnóstico por imagen , Hemangioma/diagnóstico , Neurilemoma/diagnóstico , Adulto , Anciano , Preescolar , Células Endoteliales/patología , Nervio Facial/patología , Nervio Facial/fisiopatología , Nervio Facial/cirugía , Femenino , Fibrosis/patología , Fibrosis/cirugía , Humanos , Inmunohistoquímica , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
14.
Ear Hear ; 42(3): 606-614, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33055579

RESUMEN

OBJECTIVE: To compare the cognitive evolution of older adults with severe or profound hearing impairment after cochlear implantation with that of a matched group of older adults with severe hearing impairment who do not receive a cochlear implant (CI). DESIGN: In this prospective, longitudinal, controlled, and multicenter study, 24 older CI users were included in the intervention group and 24 adults without a CI in the control group. The control group matched the intervention group in terms of gender, age, formal education, cognitive functioning, and residual hearing. Assessments were made at baseline and 14 months later. Primary outcome measurements included the change in the total score on the Repeatable Battery for the Assessment of Neuropsychological Status for Hearing impaired individuals score and on its subdomain score to assess cognitive evolution in both groups. Secondary outcome measurements included self-reported changes in sound quality (Hearing Implant Sound Quality Index), self-perceived hearing disability (Speech, Spatial, and Qualities of Hearing Scale), states of anxiety and depression (Hospital Anxiety and Depression Scale), and level of negative affectivity and social inhibition (Type D questionnaire). RESULTS: Improvements of the overall cognitive functioning (p = 0.05) and the subdomain "Attention" (p = 0.02) were observed after cochlear implantation in the intervention group; their scores were compared to the corresponding scores in the control group. Significant positive effects of cochlear implantation on sound quality and self-perceived hearing outcomes were found in the intervention group. Notably, 20% fewer traits of Type D personalities were measured in the intervention group after cochlear implantation. In the control group, traits of Type D personalities increased by 13%. CONCLUSION: Intervention with a CI improved cognitive functioning (domain Attention in particular) in older adults with severe hearing impairment compared to that of the matched controls with hearing impairment without a CI. However, older CI users did not, in terms of cognition, bridge the performance gap with adults with normal hearing after 1 year of CI use. The fact that experienced, older CI users still present subnormal cognitive functioning may highlight the need for additional cognitive rehabilitation in the long term after implantation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva , Percepción del Habla , Anciano , Cognición , Pérdida Auditiva/cirugía , Humanos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento
15.
Eur Arch Otorhinolaryngol ; 278(9): 3203-3209, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32965538

RESUMEN

PURPOSE: Analysis of head magnetic resonance images (MRI) of patients with active bone conduction implants (BCIs) is challenging. Currently, there are two generations of the transcutaneous Bonebridge system (BCI601 and BCI602), the main difference between them being the transducer design and thickness. The aim was to compare the effect of transducer placement and artifact reduction sequences on legibility of MRI scans. METHODS: Four Thiel-fixed human head specimens were used: BCI601 was implanted in sinodural and middle fossa placement, and BCI602 in middle fossa and retrosigmoid approach. Images were obtained with a Signa® 1.5T MR. A metal artifact reduction sequence known as MAVRIC (multiacquisition variable-resonance image combination) was used. Each specimen was scanned using standard axial T2 SE and compared with axial MAVRIC artifact reduction sequences. RESULTS: Qualitatively, limits of the artifact produced by the implant were better defined with MAVRIC than with standard T2 sequences. Assessment of contralateral internal auditory canal (IAC) was possible in all cases. Placement of the BCI602 in the middle fossa allowed the view of the ipsilateral IAC using MAVRIC sequence. Quantitatively, the artifact was reduced with MAVRIC sequence from 6.3 to 59.7%, depending on the position of implant and model; the middle fossa placement and the BCI602 being those generating shorter artifact radio. CONCLUSION: Artifact optimized sequences as MAVRIC reduce the artifact caused by the Bonebridge system. The middle fossa approach allows a better visualization of IAC canal in the ipsilateral ear with both implant versions, but the effect is more prominent with the BCI602.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Conducción Ósea , Humanos , Prótesis e Implantes
16.
Eur Arch Otorhinolaryngol ; 278(1): 67-75, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32451668

RESUMEN

PURPOSE: To evaluate the safety and performance of three novel vibroplasty couplers that allow attachment of the floating mass transducer of a transcutaneous active middle ear implant (AMEI) to the round window (RW) membrane, the long process (LP), or the incus body and the short process (SP) of the incus. METHODS: Retrospective multicenter cohort study of 25 AMEI users with sensorineural or mixed hearing loss that were among the first implanted with an AMEI vibrating ossicular prosthesis in combination with the third generation of vibroplasty couplers between 2014 and 2016. Main Outcome Measures were bone-conduction pure-tone and vibroplasty thresholds, postoperative aided sound field thresholds and postoperative aided word recognition score (WRS). RESULTS: Bone conduction threshold changes of more than 10 dB in 4PTABC were observed in two subjects. A mean improvement of 57.8% in speech recognition was observed with a mean WRS at 65 dB SPL improving from 14.8% (SD 21.9%) preoperatively to a mean aided score of 72.6% (SD 18.6%). Sound field thresholds improved from an average 4PTASF of 64.1 dB HL (SD 9.8 dB HL) to 37.0 dB HL (SD 8.9 dB HL), resulting in a mean functional gain of 27.1 dB. There was no significant difference in WRS or functional gain between the coupler types. CONCLUSION: Initial experience shows that all three third generation vibroplasty couplers represent safe and efficient attachment options for the FMT allowing the surgeon to choose the coupling type based on the present pathology.


Asunto(s)
Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Prótesis Osicular , Reemplazo Osicular/métodos , Adolescente , Adulto , Anciano , Niño , Estudios de Cohortes , Oído Medio , Composición Familiar , Femenino , Audífonos , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Ventana Redonda/fisiología , Ventana Redonda/cirugía , Resultado del Tratamiento , Adulto Joven
17.
Eur Arch Otorhinolaryngol ; 278(11): 4225-4233, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33788034

RESUMEN

PURPOSE: Magnetic resonance imaging (MRI) is often used to visualize and diagnose soft tissues. Hearing implant (HI) recipients are likely to require at least one MRI scan during their lifetime. However, the MRI scanner can interact with the implant magnet, resulting in complications for the HI recipient. This survey, which was conducted in two phases, aimed to evaluate the safety and performance of MRI scans for individuals with a HI manufactured by MED-EL (MED-EL GmbH, Innsbruck, Austria). METHODS: A survey was developed and distributed in two phases to HEARRING clinics to obtain information about the use of MRI for recipients of MED-EL devices. Phase 1 focused on how often MRI is used in diagnostic imaging of the head region of the cochlear implant (CI) recipients. Phase 2 collected safety information about MRI scans performed on HI recipients. RESULTS: 106 of the 126 MRI scans reported in this survey were performed at a field strength of 1.5 T, on HI recipients who wore the SYNCHRONY CI or SYNCHRONY ABI. The head and spine were the most frequently imaged regions. 123 of the 126 scans were performed without any complications; two HI recipients experienced discomfort/pain. One recipient required reimplantation after an MRI was performed using a scanner that had not been approved for that implant. There was only one case that required surgical removal of the implant to reduce the imaging artefact. CONCLUSION: Individuals with either a SYNCHRONY CI or SYNCHRONY ABI from MED-EL can safely undergo a 1.5 T MRI when it is performed according to the manufacturer's safety policies and procedures.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Audición , Humanos , Imagen por Resonancia Magnética , Imanes
18.
Glob Chang Biol ; 26(4): 2584-2598, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31923343

RESUMEN

Cover crops (CC) promote the accumulation of soil organic carbon (SOC), which provides multiple benefits to agro-ecosystems. However, additional nitrogen (N) inputs into the soil could offset the CO2 mitigation potential due to increasing N2 O emissions. Integrated management approaches use organic and synthetic fertilizers to maximize yields while minimizing impacts by crop sequencing adapted to local conditions. The goal of this work was to test whether integrated management, centered on CC adoption, has the potential to maximize SOC stocks without increasing the soil greenhouse gas (GHG) net flux and other agro-environmental impacts such as nitrate leaching. To this purpose, we ran the DayCent bio-geochemistry model on 8,554 soil sampling locations across the European Union. We found that soil N2 O emissions could be limited with simple crop sequencing rules, such as switching from leguminous to grass CC when the GHG flux was positive (source). Additional reductions of synthetic fertilizers applications are possible through better accounting for N available in green manures and from mineralization of soil reservoirs while maintaining cash crop yields. Therefore, our results suggest that a CC integrated management approach can maximize the agro-environmental performance of cropping systems while reducing environmental trade-offs.

19.
Ear Hear ; 41(6): 1648-1659, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33136639

RESUMEN

OBJECTIVES: Cochlear implants (CIs) are a well-known hearing restoration option for patients with vestibular schwannoma (VS) in cases of neurofibromatosis type-2 and, more recently, for patients with sporadic VS. One of the main limitations when performing CI during VS surgery is the capability to preserve the acoustic nerve (AN) anatomically and functionally. Significant efforts have been directed toward developing an intraoperative testing method for monitoring the AN function to determine if, after tumor removal, it is suitable for conducting stimuli delivered by a CI. However, all these methods have significant limitations, and none of them have documented diagnostic efficacy. To overcome these limitations and to obtain reliable information before CI insertion, a minimally invasive intracochlear test electrode (TE) has been recently developed. This TE has demonstrated to be suitable to test the integrity of the AN before CI in patients without any residual hearing by recording electrically evoked auditory brainstem responses (EABR). The present study constitutes the next phase of this research, which was to determine the usefulness of EABR obtained intraoperatively with the intracochlear TE after the resection of a VS and to calculate its diagnostic accuracy to assess the functionality of the AN for CI. DESIGN: This was a prospective, multicenter study of diagnostic accuracy. It was conducted in three tertiary referral centers between January 2015 and 2018. This study was designed following the Standards for Reporting of Diagnostic Accuracy Studies (STARD) statement guidelines. The STARD statement are guidelines to improve the completeness and transparency of reports of diagnostic accuracy studies. The diagnostic accuracy of the EABR evoked with the intracochlear TE after tumor removal was studied. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Patients eligible for the study were consecutive adults undergoing surgery for VS with simultaneous CI. The test under evaluation (index test) was the EABR obtained with the intracochlear TE after resection of the tumor. The reference test (gold standard) was the presence of auditory perception with the CI, defined as the presence of sound detection on an audiogram at 500, 1000, 2000, and 4000 Hz of no greater than 50 dB. In all the cases, auditory perception was verified by the presence of a positive EABR evoked with the CI. RESULTS: Twenty-one patients were included during the study period; seven patients were excluded from the diagnostic efficacy analysis due to inconclusive EABR results or absence of the gold standard to compare (they did not finally receive the CI). Thus, the outcome of the gold standard was assessed in 14 cases: 9 cases had positive EABR, all of them obtained auditory perception with the CI, and 5 cases had negative EABR, only one case had auditory perception with the CI, which constitutes the only false negative of this study. Accuracy of the TE was 93% (95% confidence interval, 66 to 100%), sensitivity 90% (95% confidence interval, 71 to 100%), specificity 100% (95% confidence interval, 100 to 100%), positive predictive value 100% (95% confidence interval, 100 to 100%), and negative predictive value 80% (95% confidence interval, 45 to 100%). CONCLUSIONS: EABR elicited with the intracochlear TE had a diagnostic accuracy of 93% for predicting auditory perception with CIs after VS removal. These results suggest that the intracochlear TE can be used intraoperatively after tumor removal to test the integrity of the AN as a useful tool to complement the surgeon's perception for decision-making regarding implantation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Neuroma Acústico , Adulto , Nervio Coclear , Potenciales Evocados Auditivos del Tronco Encefálico , Humanos , Neuroma Acústico/diagnóstico , Neuroma Acústico/cirugía , Estudios Prospectivos
20.
Int J Audiol ; 59(9): 654-660, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32174222

RESUMEN

Objective: The primary objective of this study was to compare the applicability and benefit of providing unilateral cochlear implant (CI) users with a contralateral hearing aid (HA).Design: This retrospective (case-control) study was conducted in a hospital-based CI centre. Participants self-assessed their hearing via two questionnaires (SSQ12 and HISQUI19). Objective postoperative speech perception was assessed via aided thresholds and speech perception tests (monosyllabic words, disyllabic words, and sentences) in quiet and noise.Study sample: A CI-only group (n = 113, mean age 55.1 ± 14.2 years) and a bimodal group (n = 50, mean age 56.7 ± 15.2) participated in the study.Results: No significant difference in SSQ12 or HISQUI19 scores was observed between groups. The bimodal group had a significantly better aided hearing level (p = 0.020) and speech discrimination score (p = 0.019).Conclusions: Bimodal (CI + HA) users have significantly better speech understanding than unilateral CI-only users, although this benefit may not be reflected in self-assessed outcomes. Counselling about bimodal hearing must cover expectations about potential benefits.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Audífonos , Percepción del Habla , Audición , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA