1.
Eur Respir J ; 61(3)2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36455958

RESUMEN

BACKGROUND: Mechanisms underlying blood pressure changes in obstructive sleep apnoea (OSA) are incompletely understood. Increased respiratory effort is one of the main features of OSA and is associated with sympathetic overactivity, leading to increased vascular wall stiffness and remodelling. This study investigated associations between a new measure of respiratory effort (percentage of total sleep time spent with increased respiratory effort based on measurement of mandibular jaw movements (MJM): REMOV, %TST) and prevalent hypertension in adults referred for evaluation of suspected OSA. METHODS: A machine learning model was built to predict hypertension from clinical data, conventional polysomnography (PSG) indices and MJM-derived parameters (including REMOV). The model was evaluated in a training subset and a test subset. RESULTS: The analysis included 1127 patients: 901 (80%) in the training subset and 226 (20%) in the test subset. The prevalence of hypertension was 31% and 30%, respectively, in the training and test subsets. A risk stratification model based on 18 input features including REMOV had good accuracy for predicting prevalent hypertension (sensitivity 0.75 and specificity 0.83). Using the Shapley additive explanation method, REMOV was the best predictor of hypertension after clinical risk factors (age, sex, body mass index and neck circumference) and time with oxygen saturation <90%, ahead of standard PSG metrics (including the apnoea-hypopnoea index and oxygen desaturation index). CONCLUSION: The proportion of sleep time spent with increased respiratory effort automatically derived from MJM was identified as a potential new reliable metric to predict prevalent hypertension in patients with OSA.


Asunto(s)
Hipertensión , Apnea Obstructiva del Sueño , Adulto , Humanos , Sueño , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/epidemiología , Hipertensión/complicaciones , Hipertensión/epidemiología , Polisomnografía/métodos , Factores de Riesgo
2.
Diabetes Obes Metab ; 25(10): 2815-2823, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37312670

RESUMEN

AIM: To determine the association between total sleep time (TST) spent in increased respiratory effort (RE) and the prevalence of type 2 diabetes in a large cohort of individuals with suspected obstructive sleep apnoea (OSA) referred for in-laboratory polysomnography (PSG). MATERIALS AND METHODS: We conducted a retrospective cross-sectional study using the clinical data of 1128 patients. Non-invasive measurements of RE were derived from the sleep mandibular jaw movements (MJM) bio-signal. An explainable machine-learning model was built to predict prevalent type 2 diabetes from clinical data, standard PSG indices, and MJM-derived parameters (including the proportion of TST spent with increased respiratory effort [REMOV [%TST]). RESULTS: Original data were randomly assigned to training (n = 853) and validation (n = 275) subsets. The classification model based on 18 input features including REMOV showed good performance for predicting prevalent type 2 diabetes (sensitivity = 0.81, specificity = 0.89). Post hoc interpretation using the Shapley additive explanation method found that a high value of REMOV was the most important risk factor associated with type 2 diabetes after traditional clinical variables (age, sex, body mass index), and ahead of standard PSG metrics including the apnoea-hypopnea and oxygen desaturation indices. CONCLUSIONS: These findings show for the first time that the proportion of sleep time spent in increased RE (assessed through MJM measurements) is an important predictor of the association with type 2 diabetes in individuals with OSA.


Asunto(s)
Diabetes Mellitus Tipo 2 , Apnea Obstructiva del Sueño , Humanos , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/epidemiología , Estudios Retrospectivos , Estudios Transversales , Sueño , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/epidemiología
3.
Respir Res ; 18(1): 66, 2017 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-28427400

RESUMEN

BACKGROUND: The patterns of mandibular movements (MM) during sleep can be used to identify increased respiratory effort periodic large-amplitude MM (LPM), and cortical arousals associated with "sharp" large-amplitude MM (SPM). We hypothesized that Cheyne Stokes breathing (CSB) may be identified by periodic abnormal MM patterns. The present study aims to evaluate prospectively the concordance between CSB detected by periodic MM and polysomnography (PSG) as gold-standard. The present study aims to evaluate prospectively the concordance between CSB detected by periodic MM and polysomnography (PSG) as gold-standard. METHODS: In 573 consecutive patients attending an in-laboratory PSG for suspected sleep disordered breathing (SDB), MM signals were acquired using magnetometry and scored manually while blinded from the PSG signal. Data analysis aimed to verify the concordance between the CSB identified by PSG and the presence of LPM or SPM. The data were randomly divided into training and validation sets (985 5-min segments/set) and concordance was evaluated using 2 classification models. RESULTS: In PSG, 22 patients (mean age ± SD: 65.9 ± 15.0 with a sex ratio M/F of 17/5) had CSB (mean central apnea hourly indice ± SD: 17.5 ± 6.2) from a total of 573 patients with suspected SDB. When tested on independent subset, the classification of CSB based on LPM and SPM is highly accurate (Balanced-accuracy = 0.922, sensitivity = 0.922, specificity = 0.921 and error-rate = 0.078). Logistic models based odds-ratios for CSB in presence of SPM or LPM were 172.43 (95% CI: 88.23-365.04; p < 0.001) and 186.79 (95% CI: 100.48-379.93; p < 0.001), respectively. CONCLUSION: CSB in patients with sleep disordered breathing could be accurately identified by a simple magnetometer device recording mandibular movements.


Asunto(s)
Respiración de Cheyne-Stokes/diagnóstico , Diagnóstico por Computador/métodos , Mandíbula/fisiopatología , Oscilometría/métodos , Polisomnografía/métodos , Síndromes de la Apnea del Sueño/diagnóstico , Anciano , Respiración de Cheyne-Stokes/fisiopatología , Femenino , Humanos , Aprendizaje Automático , Masculino , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Síndromes de la Apnea del Sueño/fisiopatología
5.
Exp Lung Res ; 42(1): 44-55, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26873329

RESUMEN

BACKGROUND: Systemic sclerosis (SSc) is a connective-tissue disease characterized by vascular injury, immune-system disorders, and excessive fibrosis of the skin and multiple internal organs. Recent reports found that RhoA/Rho-kinase (ROCK) pathway is implicated in various fibrogenic diseases. Intradermal injection of hypochlorous acid (HOCl)-generating solution induced inflammation, autoimmune activation, and fibrosis, mimicking the cutaneous diffuse form of SSc in humans. Our study aimed firstly to describe pulmonary inflammation and fibrosis induced by HOCl in mice, and secondly to determine whether fasudil, a selective inhibitor of ROCK, could prevent lung and skin fibroses in HOCl-injected mice. METHODS: Female C57BL/6 mice received daily intradermal injection of hypochlorous acid (HOCl) for 6 weeks to induce SSc, with and without daily treatment with fasudil (30 mg·kg(-1)·day(-1)) by oral gavage. RESULTS: HOCl intoxication induced significant lung inflammation (macrophages and neutrophils infiltration), and fibrosis. These modifications were prevented by fasudil treatment. Simultaneously, HOCl enhanced ROCK activity in lung and skin tissues. Inhibition of ROCK reduced skin fibrosis, expression of α-smooth-muscle actin and 3-nitrotyrosine, as well as the activity of ROCK in the fibrotic skin of HOCl-treated mice, through inhibition of phosphorylation of Smad2/3 and ERK1/2. Fasudil significantly decreased the serum levels of anti-DNA-topoisomerase-1 antibodies in mice with HOCl-induced SSc. CONCLUSIONS: Our findings confirm HOCl-induced pulmonary inflammation and fibrosis in mice, and provide further evidence for a key role of RhoA/ROCK pathway in several pathological processes of experimental SSc. Fasudil could be a promising therapeutic approach for the treatment of SSc.


Asunto(s)
Fibrosis Pulmonar/metabolismo , Fibrosis Pulmonar/patología , Esclerodermia Sistémica/metabolismo , Esclerodermia Sistémica/patología , Quinasas Asociadas a rho/metabolismo , 1-(5-Isoquinolinesulfonil)-2-Metilpiperazina/análogos & derivados , 1-(5-Isoquinolinesulfonil)-2-Metilpiperazina/farmacología , Actinas/metabolismo , Animales , Modelos Animales de Enfermedad , Femenino , Ácido Hipocloroso/farmacología , Pulmón/metabolismo , Sistema de Señalización de MAP Quinasas/efectos de los fármacos , Ratones , Ratones Endogámicos C57BL , Neumonía/metabolismo , Esclerodermia Sistémica/inducido químicamente , Piel/metabolismo , Proteína Smad2/metabolismo , Proteína smad3/metabolismo , Tirosina/análogos & derivados , Tirosina/metabolismo
6.
Nitric Oxide ; 45: 27-34, 2015 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-25645200

RESUMEN

PURPOSE: To assess distal/alveolar inflammation in patients with suggestive symptoms of obstructive sleep apnoea (OSA) using exhaled nitric oxide (NO) measured by two-compartment model (2-CM) after correction for axial NO back-diffusion (trumpet model). METHODS: Ninety five patients suspected for OSA prospectively underwent pulmonary function test, overnight polysomnography (PSG), and exhaled NO measurement. Patients with apnoea-hypopnoea index (AHI) < 5/hour were included in non-OSA group. Exhaled NO was repeatedly measured after PSG in 21 OSA patients and 8 non-OSA subjects. RESULTS: Alveolar NO concentration (C(ANO)) was significantly higher in OSA patients (n = 71; 4.07 ± 1.7 ppb) as compared with non-OSA subjects (n = 24; 2.24 ± 1.06 ppb; p < 0.0001) whilst maximal bronchial NO flux (J'awNO) and fractional exhaled NO (F(ENO)) did not differ between the two groups. C(ANO) was strongly associated to AHI (r = 0.701; p < 0.0001) and to recording time with SaO2 < 90% (ST-90%; r = 0.659; p < 0.0001) in OSA patients but not in non-OSA persons. The area under ROC curve for screening patients with OSA and significant nocturnal oxygen desaturation (ST-90% > 1%) was 0.865 ± 0.036 (95% IC, 0.793-0.937; p < 0.0001). C(ANO) at 4.5 ppb could detect these patients with specificity of 94% and sensitivity of 46%. Increase of C(ANO) measured after PSG was significantly related to oxygen desaturation index (ST-90%) in OSA patients. CONCLUSIONS: Increased alveolar NO concentration was related to the severity of nocturnal oxygen desaturation in patients with OSA, linking the distal airway inflammation to intermittent hypoxia. (250 words).


Asunto(s)
Óxido Nítrico/análisis , Oxígeno/metabolismo , Alveolos Pulmonares/metabolismo , Apnea Obstructiva del Sueño/metabolismo , Adulto , Anciano , Pruebas Respiratorias , Estudios de Casos y Controles , Femenino , Humanos , Hipertensión , Masculino , Persona de Mediana Edad , Polisomnografía , Estudios Prospectivos , Apnea Obstructiva del Sueño/epidemiología , Apnea Obstructiva del Sueño/fisiopatología
7.
Ann Am Thorac Soc ; 21(5): 814-822, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38330168

RESUMEN

Rationale: Oral appliances are second-line treatments after continuous positive airway pressure for obstructive sleep apnea (OSA) management. However, the need for oral appliance titration limits their use as a result of monitoring challenges to assess the treatment effect on OSA. Objectives: To assess the validity of mandibular jaw movement (MJM) automated analysis compared with polysomnography (PSG) and polygraphy (PG) in evaluating the effect of oral appliance treatment and the effectiveness of MJM monitoring for oral appliance titration at home in patients with OSA. Methods: This observational, prospective study included 135 patients with OSA eligible for oral appliance therapy. The primary outcome was the apnea-hypopnea index (AHI), measured through in-laboratory PSG/PG and MJM-based technology. Additionally, MJM monitoring at home was conducted at regular intervals during the titration process. The agreement between PSG/PG and MJM automated analysis was revaluated using Bland-Altman analysis. Changes in AHI during the home-based oral appliance titration process were evaluated using a generalized linear mixed model and a generalized estimating equation model. Results: The automated MJM analysis demonstrated strong agreement with PG in assessing AHI at the end of titration, with a median bias of 0.24/h (limits of agreement, -11.2 to 12.8/h). The improvement of AHI from baseline in response to oral appliance treatment was consistent across three evaluation conditions: in-laboratory PG (-59.6%; 95% confidence interval, -59.8% to -59.5%), in-laboratory automated MJM analysis (-59.2%; -65.2% to -52.2%), and at-home automated MJM analysis (-59.7%; -67.4% to -50.2%). Conclusions: Incorporating MJM automated analysis into the oral appliance titration process has the potential to optimize oral appliance therapy outcomes for OSA.


Asunto(s)
Polisomnografía , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/terapia , Apnea Obstructiva del Sueño/diagnóstico , Estudios Prospectivos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Mandíbula , Anciano , Presión de las Vías Aéreas Positiva Contínua/instrumentación , Presión de las Vías Aéreas Positiva Contínua/métodos , Movimiento , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación
8.
Nitric Oxide ; 28: 65-70, 2013 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-23099297

RESUMEN

Alveolar concentration of nitric oxide (C(A)NO) is a non invasive prognostic marker of systemic sclerosis (SSc) lung disease. There is, however, as yet no direct evidence showing concomitant increase of C(A)NO and the presence of inflammatory cells in alveoli. We have therefore measured C(A)NO and performed broncho-alveolar lavage (BAL) in SSc patients. Exhaled NO was measured, by the means of two different models, the two-compartment model (2CM) and the trumpet model with axial diffusion (TMAD), in 22 SSc patients and compared with 15 healthy controls. BAL was performed in all SSc patients. Alveolitis was defined as lymphocytes >14%, polymorphonuclears >4%, or eosinophils >3% on cell count in BAL fluid. Comparisons of C(A)NO levels were made between SSc patients with, and without, alveolitis. Levels of C(A)NO were significantly higher in SSc patients as compared with controls (p<0.001). Median C(A)NO was significantly higher in SSc patients with alveolitis as compared with SSc patients without alveolitis (8.4ppb; 1st and 3rd interquartile range: 6.0-10.5 vs 3.3ppb; 2.2-3.5; p=0.004 for 2CM and 5.4ppb; 3.2-9.2 vs 3.2ppb; 1.4-3.3, p=0.02 for TMAD), while bronchial airway output of NO (J'awNO, p=0.19), and fractional exhaled NO (F(E)NO, p=0.12) were comparable. C(A)NO was consistently high in SSc patients with alveolitis irrespective of the methods chosen (TMAD or 2CM). Our findings showed that increased C(A)NO was associated with alveolitis in patients with SSc. We submit that C(A)NO could be used as a reliable non-invasive surrogate biomarker of alveolitis in scleroderma lung disease.


Asunto(s)
Enfermedades Pulmonares/metabolismo , Óxido Nítrico/análisis , Óxido Nítrico/metabolismo , Esclerodermia Sistémica/metabolismo , Adulto , Femenino , Humanos , Enfermedades Pulmonares/diagnóstico , Masculino , Persona de Mediana Edad , Esclerodermia Sistémica/diagnóstico
9.
Sleep Med ; 111: 86-93, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37741085

RESUMEN

BACKGROUND: A single-night attended in-laboratory polysomnography or home sleep testing are common approaches for obstructive sleep apnea (OSA) diagnosis. However, internight variability in apnea-hypopnea index value is common, and may result in misclassification of OSA severity and inapropriate treatment decisions. OBJECTIVE: To investigate factors determining short-term apnea-hypopnea index variability using multi-night automated home sleep testing, and to determine how this variability impacts clinical decisions. PATIENTS/METHODS: Adults with suspected OSA who successfully performed three home sleep tests using measurements of mandibular jaw movements (Sunrise, Namur, Belgium) combined with automated machine learning analysis were enrolled. Data analysis included principal component analysis, generalized estimating equation regression and qualitative agreement analysis. RESULTS: 160 individuals who performed three sleep tests over a mean of 8.78 ± 8.48 days were included. The apnea-hypopnea index varied by -0.88 events/h (5th-95th percentile range: -14.33 to 9.72 events/h). Based on a single-night recording, rates of overtreatment and undertreatment would have been of 13.5% and 6.0%, respectively. Regression analysis adjusted for age, sex, body mass index, total sleep time, and time between home sleep tests showed that time spent in deep non-rapid eye movement sleep and with head in supine position were independent significant predictors of the apnea-hypopnea index variability. CONCLUSIONS: At the individual level, short-term internight variability in the apnea-hypopnea index was significantly associated with time spent in deep non-rapid eye movement sleep and head in supine position. Clinical decisions based on a single-night testing may lead to errors in OSA severity classification and incorrect therapeutic decisions.

10.
Thorax ; 67(2): 157-63, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22026971

RESUMEN

BACKGROUND: Respiratory failure is a life-threatening and unpredictable complication of systemic sclerosis (SSc). A study was undertaken to assess the value of alveolar nitric oxide (NO) in predicting the risk of lung function deterioration leading to respiratory failure or death in patients with SSc. METHODS: 105 patients with SSc were enrolled in this prospective cohort and were followed longitudinally over a 3-year period during which the risk of occurrence of deleterious events was analysed according to alveolar concentration (C(A)NO), conducting airway output (J'(aw)NO) and fractional concentration (F(E)NO(0.05)) of exhaled NO measured at inclusion. Comparison was made between each NO parameter to predict the occurrence of deleterious events, defined as a 10% decrease in total lung capacity or forced vital capacity from baseline, or death. RESULTS: The area under the receiver operating characteristic curve of C(A)NO to predict the occurrence of the combined events was 0.84 (95% CI 0.76 to 0.92; p<0.001), which was significantly higher than those of J'(aw)NO and F(E)NO(0.05) (p<0.001). A cut-off of C(A)NO of 5.3 ppb had a sensitivity of 88% and a specificity of 62% for the prediction of the occurrence of combined events during follow-up, and was validated in an independent cohort of patients with SSc. Combined events occurred more frequently in patients whose C(A)NO was >5.3 ppb. The adjusted HR for patients with C(A)NO >5.3 ppb was 6.06 (95% CI 2.36 to 15.53; p<0.001). C(A)NO accurately predicted the occurrence of combined events irrespective of forced vital capacity values or the presence of interstitial lung disease at baseline. CONCLUSIONS: Increased C(A)NO accurately identifies patients with SSc with a high risk of developing lung function deterioration and may help to initiate early appropriate treatment.


Asunto(s)
Enfermedades Pulmonares Intersticiales/diagnóstico , Óxido Nítrico/metabolismo , Alveolos Pulmonares/metabolismo , Esclerodermia Sistémica/complicaciones , Adulto , Anciano , Biomarcadores/metabolismo , Pruebas Respiratorias/métodos , Progresión de la Enfermedad , Métodos Epidemiológicos , Femenino , Humanos , Enfermedades Pulmonares Intersticiales/etiología , Enfermedades Pulmonares Intersticiales/metabolismo , Enfermedades Pulmonares Intersticiales/fisiopatología , Masculino , Persona de Mediana Edad , Pronóstico , Esclerodermia Sistémica/metabolismo , Esclerodermia Sistémica/fisiopatología , Capacidad Vital/fisiología
11.
Nat Sci Sleep ; 14: 635-644, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35444480

RESUMEN

Purpose: Differentiation between obstructive and central apneas and hypopneas requires quantitative measurement of respiratory effort (RE) using esophageal pressure (PES), which is rarely implemented. This study investigated whether the sleep mandibular movements (MM) signal recorded with a tri-axial gyroscopic chin sensor (Sunrise, Namur, Belgium) is a reliable surrogate of PES in patients with suspected obstructive sleep apnea (OSA). Patients and Methods: In-laboratory polysomnography (PSG) with PES and concurrent MM monitoring was performed. PSGs were scored manually using AASM 2012 rules. Data blocks (n=8042) were randomly sampled during normal breathing (NB), obstructive or central apnea/hypopnea (OA/OH/CA/CH), respiratory effort-related arousal (RERA), and mixed apnea (MxA). Analyses were evaluation of the similarity and linear correlation between PES and MM using the longest common subsequence (LCSS) algorithm and Pearson's coefficient; description of signal amplitudes; estimation of the marginal effect for crossing from NB to a respiratory disturbance for a given change in MM signal using a mixed linear-regression. Results: Participants (n=38) had mild to severe OSA (median AH index 28.9/h; median arousal index 23.2/h). MM showed a high level of synchronization with concurrent PES signals. Distribution of MM amplitude differed significantly between event types: median (95% confidence interval) values of 0.60 (0.16-2.43) for CA, 0.83 (0.23-4.71) for CH, 1.93 (0.46-12.43) for MxA, 3.23 (0.72-18.09) for OH, and 6.42 (0.88-26.81) for OA. Mixed regression indicated that crossing from NB to central events would decrease MM signal amplitude by -1.23 (CH) and -2.04 (CA) units, while obstructive events would increase MM amplitude by +3.27 (OH) and +6.79 (OA) units (all p<10-6). Conclusion: In OSA patients, MM signals facilitated the measurement of specific levels of RE associated with obstructive, central or mixed apneas and/or hypopneas. A high degree of similarity was observed with the PES gold-standard signal.

12.
J Pers Med ; 12(9)2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-36143214

RESUMEN

With the rapid development of computing today, artificial intelligence has become an essential part of everyday life, with medicine and lung health being no exception. Big data-based scientific research does not mean simply gathering a large amount of data and letting the machines do the work by themselves. Instead, scientists need to identify problems whose solution will have a positive impact on patients' care. In this review, we will discuss the role of artificial intelligence from both physiological and anatomical standpoints, starting with automatic quantitative assessment of anatomical structures using lung imaging and considering disease detection and prognosis estimation based on machine learning. The evaluation of current strengths and limitations will allow us to have a broader view for future developments.

13.
Front Neurosci ; 16: 726880, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35368281

RESUMEN

Background: The capacity to diagnose obstructive sleep apnoea (OSA) must be expanded to meet an estimated disease burden of nearly one billion people worldwide. Validated alternatives to the gold standard polysomnography (PSG) will improve access to testing and treatment. This study aimed to evaluate the diagnosis of OSA, using measurements of mandibular movement (MM) combined with automated machine learning analysis, compared to in-home PSG. Methods: 40 suspected OSA patients underwent single overnight in-home sleep testing with PSG (Nox A1, ResMed, Australia) and simultaneous MM monitoring (Sunrise, Sunrise SA, Belgium). PSG recordings were manually analysed by two expert sleep centres (Grenoble and London); MM analysis was automated. The Obstructive Respiratory Disturbance Index calculated from the MM monitoring (MM-ORDI) was compared to the PSG (PSG-ORDI) using intraclass correlation coefficient and Bland-Altman analysis. Receiver operating characteristic curves (ROC) were constructed to optimise the diagnostic performance of the MM monitor at different PSG-ORDI thresholds (5, 15, and 30 events/hour). Results: 31 patients were included in the analysis (58% men; mean (SD) age: 48 (15) years; BMI: 30.4 (7.6) kg/m2). Good agreement was observed between MM-ORDI and PSG-ORDI (median bias 0.00; 95% CI -23.25 to + 9.73 events/hour). However, for 15 patients with no or mild OSA, MM monitoring overestimated disease severity (PSG-ORDI < 5: MM-ORDI mean overestimation + 5.58 (95% CI + 2.03 to + 7.46) events/hour; PSG-ORDI > 5-15: MM-ORDI overestimation + 3.70 (95% CI -0.53 to + 18.32) events/hour). In 16 patients with moderate-severe OSA (n = 9 with PSG-ORDI 15-30 events/h and n = 7 with a PSG-ORD > 30 events/h), there was an underestimation (PSG-ORDI > 15: MM-ORDI underestimation -8.70 (95% CI -28.46 to + 4.01) events/hour). ROC optimal cut-off values for PSG-ORDI thresholds of 5, 15, 30 events/hour were: 9.53, 12.65 and 24.81 events/hour, respectively. These cut-off values yielded a sensitivity of 88, 100 and 79%, and a specificity of 100, 75, 96%. The positive predictive values were: 100, 80, 95% and the negative predictive values 89, 100, 82%, respectively. Conclusion: The diagnosis of OSA, using MM with machine learning analysis, is comparable to manually scored in-home PSG. Therefore, this novel monitor could be a convenient diagnostic tool that can easily be used in the patients' own home. Clinical Trial Registration: https://clinicaltrials.gov, identifier NCT04262557.

14.
J Clin Med ; 11(12)2022 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-35743615

RESUMEN

We aimed to investigate the performance of a chest X-ray (CXR) scoring scale of lung injury in prediction of death and ICU admission among patients with COVID-19 during the 2021 peak pandemic in HCM City, Vietnam. CXR and clinical data were collected from Vinmec Central Park-hospitalized patients from July to September 2021. Three radiologists independently assessed the day-one CXR score consisting of both severity and extent of lung lesions (maximum score = 24). Among 219 included patients, 28 died and 34 were admitted to the ICU. There was a high consensus for CXR scoring among radiologists (κ = 0.90; CI95%: 0.89-0.92). CXR score was the strongest predictor of mortality (tdAUC 0.85 CI95% 0.69-1) within the first 3 weeks after admission. A multivariate model confirmed a significant effect of an increased CXR score on mortality risk (HR = 1.33, CI95%: 1.10 to 1.62). At a threshold of 16 points, the CXR score allowed for predicting in-hospital mortality and ICU admission with good sensitivity (0.82 (CI95%: 0.78 to 0.87) and 0.86 (CI95%: 0.81 to 0.90)) and specificity (0.89 (CI95%: 0.88 to 0.90) and 0.87 (CI95%: 0.86 to 0.89)), respectively, and can be used to identify high-risk patients in needy countries such as Vietnam.

15.
Nat Sci Sleep ; 13: 763-773, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34163272

RESUMEN

PURPOSE: Our study aimed to evaluate the relationship between exhaled nitric oxide (eNO) markers and obstructive sleep apnea (OSA) severity and verify the changes in eNO profiles among mild, moderate, and severe OSA subgroups. METHODS: This study was a cross-sectional and in-hospital population-based study. We investigated 123 OSA patients (17 mild, 23 moderate and, 83 severe OSA) in the department of respiratory diseases. Studied data included anthropometry, respiratory polygraphy, biological markers, spirometry, and multi-flow eNO measurements. Data analysis implied linear correlation, non-parametric ANOVA, and pair-wise comparison. RESULTS: No significant difference could be found among 3 OSA severity subgroups for FENO at - four sampling flow rates (50-350 mL/s). The bronchial production rate of NO (J'awNO) was proportionally increased, with median values of 11.2, 33.9, and 36.2 in mild, moderate, and severe OSA, respectively (p=0.010). The alveolar concentration of NO (CANO) changed with a non-linear pattern; it was increased in moderate (6.49) vs mild (7.79) OSA but decreased in severe OSA (5.20, p = 0.015). The only correction that could be established between OSA severity and exhaled nitric oxide markers is through J'AWNO (rho=0.25, p=0.02) and CANO (rho= 0.18, p=0.04). There was no significant correlation between FENO measured at three different flow rates and the OSA severity. We also found a weak but significant correlation between FENO 100 and averaged SpO2 (rho = 0.07, p= 0.03). CONCLUSION: The present study showed that J'AWNO, which represents eNO derived from the central airway, is proportionally increased in more severe OSA, while eNO from alveolar space, indicated by CANO, was also associated with OSA severity and relatively lower in the most severe OSA patients. In contrast, stand-alone FENO metrics did not show a clear difference among the three severity subgroups.

16.
Nat Sci Sleep ; 13: 1449-1459, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34466045

RESUMEN

PURPOSE: Sleep bruxism (SBx) activity is classically identified by capturing masseter and/or temporalis masticatory muscles electromyographic activity (EMG-MMA) during in-laboratory polysomnography (PSG). We aimed to identify stereotypical mandibular jaw movements (MJM) in patients with SBx and to develop rhythmic masticatory muscles activities (RMMA) automatic detection using an artificial intelligence (AI) based approach. PATIENTS AND METHODS: This was a prospective, observational study of 67 suspected obstructive sleep apnea (OSA) patients in whom PSG with masseter EMG was performed with simultaneous MJM recordings. The system used to collect MJM consisted of a small hardware device attached on the chin that communicates to a cloud-based infrastructure. An extreme gradient boosting (XGB) multiclass classifier was trained on 79,650 10-second epochs of MJM data from the 39 subjects with a history of SBx targeting 3 labels: RMMA episodes (n=1072), micro-arousals (n=1311), and MJM occurring at the breathing frequency (n=77,267). RESULTS: Validated on unseen data from 28 patients, the model showed a very good epoch-by-epoch agreement (Kappa = 0.799) and balanced accuracy of 86.6% was found for the MJM events when using RMMA standards. The RMMA episodes were detected with a sensitivity of 84.3%. Class-wise receiver operating characteristic (ROC) curve analysis confirmed the well-balanced performance of the classifier for RMMA (ROC area under the curve: 0.98, 95% confidence interval [CI] 0.97-0.99). There was good agreement between the MJM analytic model and manual EMG signal scoring of RMMA (median bias -0.80 events/h, 95% CI -9.77 to 2.85). CONCLUSION: SBx can be reliably identified, quantified, and characterized with MJM when subjected to automated analysis supported by AI technology.

17.
Chest ; 157(3): e59-e62, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32145817

RESUMEN

Bruxism is a heterogeneous condition related to various underlying mechanisms, including the presence of OSA. This case report illustrates that sleep mandibular movement monitoring and analysis could provide a useful opportunity for detection of both sleep bruxism and respiratory effort. The current case suggests that tracking of respiratory effort could enable evaluation of bruxism and its potential interactions. Successful treatment of sleep-related respiratory effort may lead to improved or resolution of bruxism in cases where such a causal relationship does exist.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/terapia , Bruxismo del Sueño/diagnóstico , Electromiografía , Femenino , Humanos , Músculo Masetero/fisiopatología , Persona de Mediana Edad , Polisomnografía , Apnea Obstructiva del Sueño/complicaciones , Bruxismo del Sueño/complicaciones , Bruxismo del Sueño/fisiopatología
18.
Respir Physiol Neurobiol ; 279: 103447, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32416331

RESUMEN

RATIONALE: Mandibular position and motion during sleep rely on the balance between mandibular elevators and depressors. We hypothesized that vertical mandibular position (VMP) modulates airflow amplitude during sleep. METHODS: VMP, tidal nasal flow pressure (NFP) and concurrent surface electromyographic activity of the masseters (sEMG-m) were recorded and processed by a customized algorithm from 100 polysomnographic fragments including a micro-arousal (25 obstructive sleep apnea patients). The relationship between mandibular position and changes in airflow was analysed. RESULT: Concurrent VMP and sEMG-m activity changes routinely occurred before a new steady state of airflow documented by NFP. Vertical mandible depression was associated with a median (95% CI) reduction in NFP of 40.9% (14.6%-71.3%, p = 0.007) while vertical mandible elevation and mouth closure were associated with a median (95% CI) relative increase in NFP after arousal of 52.6% (17.9%-56.2%, p = 0.001). CONCLUSION: Elevation and lowering of the mandible were associated with changes in masseteric EMG activity modulating airflow amplitude during sleep.


Asunto(s)
Mandíbula/fisiología , Músculos Masticadores/fisiología , Ferulas Oclusales , Músculos Faríngeos/fisiología , Mecánica Respiratoria/fisiología , Apnea Obstructiva del Sueño/fisiopatología , Adulto , Anciano , Estudios Transversales , Electromiografía , Femenino , Humanos , Masculino , Mandíbula/fisiopatología , Músculos Masticadores/fisiopatología , Persona de Mediana Edad , Músculos Faríngeos/fisiopatología , Polisomnografía , Estudios Prospectivos , Sueño/fisiología , Apnea Obstructiva del Sueño/rehabilitación
19.
JAMA Netw Open ; 3(1): e1919657, 2020 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-31968116

RESUMEN

Importance: Given the high prevalence of obstructive sleep apnea (OSA), there is a need for simpler and automated diagnostic approaches. Objective: To evaluate whether mandibular movement (MM) monitoring during sleep coupled with an automated analysis by machine learning is appropriate for OSA diagnosis. Design, Setting, and Participants: Diagnostic study of adults undergoing overnight in-laboratory polysomnography (PSG) as the reference method compared with simultaneous MM monitoring at a sleep clinic in an academic institution (Sleep Laboratory, Centre Hospitalier Universitaire Université Catholique de Louvain Namur Site Sainte-Elisabeth, Namur, Belgium). Patients with suspected OSA were enrolled from July 5, 2017, to October 31, 2018. Main Outcomes and Measures: Obstructive sleep apnea diagnosis required either evoking signs or symptoms or related medical or psychiatric comorbidities coupled with a PSG-derived respiratory disturbance index (PSG-RDI) of at least 5 events/h. A PSG-RDI of at least 15 events/h satisfied the diagnosis criteria even in the absence of associated symptoms or comorbidities. Patients who did not meet these criteria were classified as not having OSA. Agreement analysis and diagnostic performance were assessed by Bland-Altman plot comparing PSG-RDI and the Sunrise system RDI (Sr-RDI) with diagnosis threshold optimization via receiver operating characteristic curves, allowing for evaluation of the device sensitivity and specificity in detecting OSA at 5 events/h and 15 events/h. Results: Among 376 consecutive adults with suspected OSA, the mean (SD) age was 49.7 (13.2) years, the mean (SD) body mass index was 31.0 (7.1), and 207 (55.1%) were men. Reliable agreement was found between PSG-RDI and Sr-RDI in patients without OSA (n = 46; mean difference, 1.31; 95% CI, -1.05 to 3.66 events/h) and in patients with OSA with a PSG-RDI of at least 5 events/h with symptoms (n = 107; mean difference, -0.69; 95% CI, -3.77 to 2.38 events/h). An Sr-RDI underestimation of -11.74 (95% CI, -20.83 to -2.67) events/h in patients with OSA with a PSG-RDI of at least 15 events/h was detected and corrected by optimization of the Sunrise system diagnostic threshold. The Sr-RDI showed diagnostic capability, with areas under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.96) and 0.93 (95% CI, 0.90-0.93) for corresponding PSG-RDIs of 5 events/h and 15 events/h, respectively. At the 2 optimal cutoffs of 7.63 events/h and 12.65 events/h, Sr-RDI had accuracy of 0.92 (95% CI, 0.90-0.94) and 0.88 (95% CI, 0.86-0.90) as well as posttest probabilities of 0.99 (95% CI, 0.99-0.99) and 0.89 (95% CI, 0.88-0.91) at PSG-RDIs of at least 5 events/h and at least 15 events/h, respectively, corresponding to positive likelihood ratios of 14.86 (95% CI, 9.86-30.12) and 5.63 (95% CI, 4.92-7.27), respectively. Conclusions and Relevance: Automatic analysis of MM patterns provided reliable performance in RDI calculation. The use of this index in OSA diagnosis appears to be promising.


Asunto(s)
Nervio Mandibular/fisiopatología , Monitoreo Ambulatorio/instrumentación , Movimiento , Polisomnografía/instrumentación , Polisomnografía/métodos , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/fisiopatología , Adulto , Bélgica , Femenino , Humanos , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
20.
Nitric Oxide ; 20(3): 200-6, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19100854

RESUMEN

Nitric oxide metabolites (NOx) in serum, and alveolar concentration of NO (CA(NO)), are markers of inflammation and alveolitis, respectively, in systemic sclerosis (SSc). We prospectively evaluated the usefulness of both NOx and CA(NO) to assess lung involvement and skin fibrosis in SSc. Serum NOx, and CA(NO) measured by two different methods, namely the two-compartment (2CM) and the "trumpet" models (TM), were concomitantly assessed in 65 patients with SSc and 17 healthy controls. Whilst serum NOx remained comparable between groups, CA(NO) were significantly higher in SSc patients (n=65, 6.7ppb; 4.8-9.7 and 5.9ppb; 3.9-8.9) as compared with controls (n=17, 3.0ppb; 2.0-3.8 and 1.8ppb; 1.1-2.9, p<0.001, p<0.001) using the 2CM and the TM, respectively). CA(NO) from SSc patients with interstitial lung disease (ILD) (n=26, 8.6ppb; 6.5-10.9 and 8.5ppb; 5.9-10.7) or pulmonary arterial hypertension (n=12, 7.3ppb; 6.5-10.4 and 6.9ppb; 5.4-9.9) were significantly higher as compared with patients without ILD (n=27, 4.9ppb; 3.8-6.5 and 4.7ppb; 2.8-5.7; p<0.001 and p<0.001) using the 2CM and the TM, respectively). CA(NO) assessed either by the 2CM or the trumpet model were directly related to the extent of ILD and inversely related to DLCO. There was no correlation between NOx and ILD, or DLCO. Neither CA(NO) nor NOx was correlated with skin fibrosis and no relationship was found between CA(NO) and NOx. Alveolar concentration of NO, but not serum NOx, closely correlates with the extent of ILD in patients with systemic sclerosis. Neither parameter, however, is related to skin fibrosis.


Asunto(s)
Enfermedades Pulmonares Intersticiales/diagnóstico , Óxido Nítrico/análisis , Esclerodermia Sistémica/complicaciones , Adulto , Biomarcadores/análisis , Estudios de Casos y Controles , Espiración , Femenino , Fibrosis , Humanos , Enfermedades Pulmonares Intersticiales/etiología , Masculino , Persona de Mediana Edad , Nitratos/sangre , Óxido Nítrico/metabolismo , Nitritos/sangre , Alveolos Pulmonares/metabolismo , Enfermedades de la Piel/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA