Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pediatr Cardiol ; 2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37606651

RESUMEN

Radiofrequency (RF) perforation of an atretic pulmonary valve is commonly performed in patients with pulmonary atresia with intact ventricular septum with specifically designed RF wires. In difficult anatomy or low-resource centers, this may instead be successfully performed with a modified coronary guide wire and an electrocautery surgical pencil.

2.
Pediatr Cardiol ; 44(7): 1623-1628, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37418147

RESUMEN

VA-ECMO can be lifesaving in cardiogenic shock in children. While surgical vascular repair is the current standard of care for decannulation, it comes with notable risks. We present a series of eight patients who underwent decannulation with a collagen plug-based vascular closure device (MANTA) for the common femoral artery. Seven of the patients were successfully decannulated without access site-related vascular complications. One required conversion to surgical cut-down with arterial repair due to device failure. This series demonstrates the successful use of the MANTA device in percutaneous VA-ECMO decannulation in the pediatric population, while highlighting potential technical challenges for success.


Asunto(s)
Cateterismo Periférico , Oxigenación por Membrana Extracorpórea , Pediatría , Dispositivos de Cierre Vascular , Humanos , Niño , Oxigenación por Membrana Extracorpórea/efectos adversos , Cateterismo Periférico/efectos adversos , Estudios Retrospectivos , Arteria Femoral/cirugía , Resultado del Tratamiento
3.
Pediatr Crit Care Med ; 20(8): 728-736, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30985609

RESUMEN

OBJECTIVES: To assess the variation in timing of left atrial decompression and its association with clinical outcomes in pediatric patients supported with venoarterial extracorporeal membrane oxygenation across a multicenter cohort. DESIGN: Multicenter retrospective study. SETTING: Eleven pediatric hospitals within the United States. PATIENTS: Patients less than 18 years on venoarterial extracorporeal membrane oxygenation who underwent left atrial decompression from 2004 to 2016. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 137 patients (median age, 4.7 yr) were included. Cardiomyopathy was the most common diagnosis (47%). Cardiac arrest (39%) and low cardiac output (50%) were the most common extracorporeal membrane oxygenation indications. Median time to left atrial decompression was 6.2 hours (interquartile range, 3.8-17.2 hr) with the optimal cut-point of greater than or equal to 18 hours for late decompression determined by receiver operating characteristic curve. In univariate analysis, late decompression was associated with longer extracorporeal membrane oxygenation duration (median 8.5 vs 5 d; p = 0.02). In multivariable analysis taking into account clinical confounder and center effects, late decompression remained significantly associated with prolonged extracorporeal membrane oxygenation duration (adjusted odds ratio, 4.4; p = 0.002). Late decompression was also associated with longer duration of mechanical ventilation (adjusted odds ratio, 4.8; p = 0.002). Timing of decompression was not associated with in-hospital survival (p = 0.36) or overall survival (p = 0.42) with median follow-up of 3.2 years. CONCLUSIONS: In this multicenter study of pediatric patients receiving venoarterial extracorporeal membrane oxygenation, late left atrial decompression (≥ 18 hr) was associated with longer duration of extracorporeal membrane oxygenation support and mechanical ventilation. Although no survival benefit was demonstrated, the known morbidities associated with prolonged extracorporeal membrane oxygenation use may justify a recommendation for early left atrial decompression.


Asunto(s)
Descompresión Quirúrgica/métodos , Oxigenación por Membrana Extracorpórea/métodos , Atrios Cardíacos/cirugía , Niño , Preescolar , Descompresión Quirúrgica/mortalidad , Oxigenación por Membrana Extracorpórea/mortalidad , Femenino , Humanos , Lactante , Unidades de Cuidado Intensivo Pediátrico/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
4.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30506273

RESUMEN

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Fluoroscopía/efectos adversos , Cardiopatías Congénitas/cirugía , Exposición a la Radiación , Radiografía Intervencional/efectos adversos , Adolescente , Niño , Preescolar , Consenso , Humanos , Lactante , Estudios Prospectivos , Mejoramiento de la Calidad , Dosis de Radiación , Medición de Riesgo/métodos , Factores de Riesgo , Adulto Joven
5.
Catheter Cardiovasc Interv ; 90(2): 269-280, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28198573

RESUMEN

OBJECTIVES: This study sought to update benchmark values to use a quality measure prospectively. BACKGROUND: Congenital Cardiac Catheterization Outcomes Project - Quality Improvement (C3PO-QI), a multi-center registry, defined initial radiation dose benchmarks retrospectively across common interventional procedures. These data facilitated a dose metric endorsed by the American College of Cardiology in 2014. METHODS: Data was collected prospectively by 9 C3PO-QI institutions with complete case capture between 1/1/2014 and 6/30/2015. Radiation was measured in total air kerma (mGy), dose area product (DAP) (µGy*M2 ), DAP per body weight, and fluoroscopy time (min), and reported by age group as median, 75th and 95th %ile for the following six interventional procedures: (1) atrial septal defect closure; (2) aortic valvuloplasty; (3) treatment of coarctation of the aorta; (4) patent ductus arteriosus closure; (5) pulmonary valvuloplasty; and (6) transcatheter pulmonary valve implantation. RESULTS: The study was comprised of 1,680 unique cases meeting inclusion criteria. Radiation doses were lowest for pulmonary valvuloplasty (age <1 yrs, median mGy: 59, DAP: 249) and highest in transcatheter pulmonary valve implantation (age >15 yrs, median mGy: 1835, DAP: 17990). DAP/kg standardized outcome measures across weights within an age group and procedure type significantly more than DAP alone. Radiation doses decreased for all procedures compared to those reported previously by both median and median weight-based percentile curves. These differences in radiation exposure were observed without changes in median fluoroscopy time. CONCLUSIONS: This study updates previously established benchmarks to reflect QI efforts over time. These thresholds can be applied for quality measurement and comparison. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Benchmarking/normas , Cateterismo Cardíaco/normas , Cardiopatías Congénitas/terapia , Pediatría/normas , Dosis de Radiación , Exposición a la Radiación/normas , Radiografía Intervencional/normas , Adolescente , Factores de Edad , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Lactante , Masculino , Seguridad del Paciente/normas , Estudios Prospectivos , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Radiografía Intervencional/efectos adversos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Estados Unidos
6.
Pediatr Cardiol ; 37(8): 1436-1445, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27502109

RESUMEN

The Congenital Cardiac Catheterization Project on Outcomes (C3PO) launched in 2007 as a multi-center collaborative to establish standardized and comparable metrics for pediatric cardiac catheterization procedures. The limitations of larger registries at the time led to the development of the next phase in 2013, C3PO-Quality Improvement (C3PO-QI), focusing on instituting QI initiatives within the field. The objective of this manuscript is to provide a detailed overview of C3PO-QI and report data on case characteristics and outcome metrics being explored. C3PO-QI was designed to cultivate institutional collaboration during implementation of its initiatives. A database and website were developed to support data entry and on-demand reporting. The registry prospectively captures pediatric cardiac catheterization data among 15 hospitals. The present study includes case demographic data (n) and quality metric reporting by case type, age, and radiation dose variables. This dataset includes 13,135 cases entered into the database between 1/1/2014 and 12/31/2015. Interventional cases make up the highest percentage by case mix distribution (48 %), and patients <1 years make up the highest percentage by age distribution (26 %). The ratio of diagnostic and interventional procedures performed changes by age group. Application of QI metric shows all procedure types surpassing metric goals. Large volume data collection, such as in C3PO-QI, allows for meaningful interpretation of data. C3PO-QI is uniquely poised to deliver fast-paced changes in the field. Although the project initiatives are specific to pediatric cardiac catheterization, the implementation of the project and utilization of real-time reporting is generalizable to other specialties and multi-center collaboratives.


Asunto(s)
Cateterismo Cardíaco , Niño , Bases de Datos Factuales , Cardiopatías Congénitas , Humanos , Mejoramiento de la Calidad , Sistema de Registros
7.
Catheter Cardiovasc Interv ; 86(3): 438-52, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25676815

RESUMEN

OBJECTIVES: To investigate the spectrum, etiology, and management of traumatic aortopulmonary (AP) communications after transcatheter interventions on the pulmonary circulation. BACKGROUND: An iatrogenic AP communication is an unusual complication after balloon pulmonary artery (PA) angioplasty or stenting, or transcatheter pulmonary valve replacement (TPVR). However, with the increasing application of transcatheter therapies for postoperative PA stenosis and right ventricular outflow tract (RVOT) dysfunction, including percutaneous pulmonary valve replacement, consideration of the etiology, diagnosis, and management of this problem is important for interventional cardiologists performing such procedures. METHODS AND RESULTS: We present three new cases, as well as gross anatomy and histopathology data, related to AP communications after PA interventions. We also review the literature relevant to this topic. Including these new cases, there have been 18 reported cases of iatrogenic AP communication after transcatheter interventions on the PAs or RVOT, primarily patients with transposition of the great arteries who underwent PA angioplasty after an arterial switch operation, or after TPVR in patients who had undergone a Ross procedure. The likely cause of such defects is PA trauma plus distortion of the neo-aortic anastomosis resulting from angioplasty or stenting of the RVOT or central PAs, with subsequent dissection through the extravascular connective tissue and into the closely adjacent vessel through the devitalized tissue at the anastomosis. CONCLUSIONS: Cardiologists performing PA or RVOT interventions should be aware of the possibility of a traumatic AP communication and consider this diagnosis when confronted with suggestive signs and symptoms.


Asunto(s)
Aorta/lesiones , Cateterismo Cardíaco/efectos adversos , Cardiopatías Congénitas/cirugía , Arteria Pulmonar/lesiones , Angioplastia Coronaria con Balón/efectos adversos , Niño , Angiografía Coronaria , Ecocardiografía Doppler en Color , Fluoroscopía , Cardiopatías Congénitas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas , Ventrículos Cardíacos/fisiopatología , Humanos , Enfermedad Iatrogénica , Falla de Prótesis , Recurrencia , Stents/efectos adversos , Adulto Joven
8.
Artículo en Inglés | MEDLINE | ID: mdl-36244628

RESUMEN

Evaluate the use of coronary CTA as an initial assessment for determining Right Ventricle Dependent Coronary Circulation (RVDCC) in neonates with Pulmonary Atresia with Intact Ventricular Septum (PA IVS). Retrospective review of cases with coronary CTA and compare with available catheter angiography, pathology, surgical reports, and outcomes from Mar 2015 to May 2022. In our cohort of 16 patients, 3 were positive for RVDCC, confirmed by pathologic evaluation, and there was concordance for presence or absence of RVDCC with catheter angiography in 5 patients (4 negatives for RVDCC, 1 positive). Clinical follow up for the 8 patients that underwent RV decompression had no clinical evidence of myocardial ischemia. Our findings suggest that coronary CTA is reliable as first-line imaging for determination of RVDCC in neonates with PA IVS. These findings, if supported by further prospective study, may reserve invasive coronary angiography for cases with diagnostic uncertainty or at the time of necessary transcatheter interventions.

9.
J Am Coll Cardiol ; 75(4): 363-376, 2020 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-32000947

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) is associated with a risk of procedural serious adverse events (SAE) and exposure to ionizing radiation. OBJECTIVES: The purpose of this study was to define the risk of, and associations with, SAE and high-dose radiation exposure using large-scale registry data. METHODS: The analysis of the multicenter C3PO-QI registry was limited to patients who underwent TPVR from January 1, 2014, to December 31, 2016. SAE were defined as the occurrence of ≥1 moderate, major, or catastrophic events. Radiation dose was reported as dose area product adjusted for weight. Associations with outcome measures were explored in univariate and multivariable analyses. RESULTS: A total of 530 patients (59% male) underwent TPVR at a median age of 18.3 years (interquartile range [IQR]: 12.9 to 27.3 years) and weight of 58 kg (IQR: 43 to 77 kg) at 14 centers. Implant substrate included homograft (41%), bioprosthesis (30%), native right ventricular outflow tract (RVOT) (27%) and other (2%). TPVR indications were pulmonary insufficiency (28%), stenosis (23%), and mixed (49%). AE and SAE occurred in 26% and 13% of cases, respectively, including 1 mortality. SAE were more frequent in homograft conduit than other RVOT substrates, although SAE type and severity differed between implant substrates. Median radiation dose was 198 µGy·m2/kg (IQR: 94 to 350 µGy·m2/kg). Higher radiation dose was associated with older age, greater RVOT obstruction, and concomitant interventions (p < 0.001). During a median follow-up duration of 1 year, 13.3% underwent catheterization, surgery, or both, unrelated to infection. Younger age, smaller size, and hemodynamic and anatomic factors indicative of greater RVOT obstruction were associated with TPV reintervention. CONCLUSIONS: The incidence of SAE during TPVR in the C3PO-QI registry is high, but mortality is uncommon. Radiation dose is greater than for other congenital interventions and is associated with patient and procedural factors. Reintervention is common during early follow-up.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Exposición a la Radiación , Radiación Ionizante , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cateterismo , Niño , Endocarditis/cirugía , Femenino , Cardiopatías Congénitas/cirugía , Humanos , Incidencia , Masculino , Análisis Multivariante , Sistema de Registros , Riesgo , Tetralogía de Fallot/cirugía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA