Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Clin Virol ; 47(3): 238-42, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20117963

RESUMEN

BACKGROUND: Standard preparations for HBsAg are required for quality control of test kits and clinical studies on HBsAg quantitation. WHO provides purified heat inactivated HBsAg diluted in negative defribinated plasma as 2nd International Standard (IS) for quality control of tests. OBJECTIVE: Study of possible alterations of antigenicity, protein composition, size and density of the heat inactivated source material (SM) for the 2nd IS. STUDY DESIGN: Native HBsAg and SM were examined by quantitative immune electrophoresis (QIE), SDS-PAGE, ultracentrifugation and gel chromatography. HBV DNA was sequenced and the HBsAg geno/subtype derived. RESULTS: The SM contained 97,600 International Units HBsAg/ml in QIE which agreed very well with the previous evaluations by WHO using 10 different assays. In SDS-PAGE, SM showed on a strong background the small HBs proteins but no preS proteins. SM had a more heterogeneous density than native HBsAg and contained particle aggregates. The HBsAg geno/subtype of SM was A2/adw2. CONCLUSIONS: The IS has very good HBs antigenicity, but it lacks the preS domains, has modified HBs proteins and is partially aggregated. While it has been proven very useful for quality control of tests, certain inconsistencies due to the altered structure of its HBsAg cannot be excluded.


Asunto(s)
Antígenos de Superficie de la Hepatitis B/química , Antígenos de Superficie de la Hepatitis B/inmunología , Hepatitis B/diagnóstico , Inmunoensayo/normas , Virología/métodos , Animales , Cromatografía en Gel , Electroforesis en Gel de Poliacrilamida , Humanos , Estándares de Referencia , Ultracentrifugación
2.
Transfusion ; 45(8): 1258-66, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16078910

RESUMEN

BACKGROUND: The performance of the recently launched Procleix Ultrio (Chiron/Gen-Probe) human immunodeficiency virus-1 (HIV-1), hepatitis C virus (HCV), and hepatitis B virus (HBV) blood screening assay was evaluated in a European multicenter study. STUDY DESIGN AND METHODS: Serial dilutions of reference materials were tested to determine the detection limits. Robustness and specificity were assessed by testing alternating high-load HCV RNA-positive and -negative samples, and 2912 test pools of eight donations. The added value of minipool and single-donation HBV nucleic acid testing protocols was compared to the currently used Prism (Abbott GmbH & Co. KG) hepatitis B surface antigen (HBsAg) and Auszyme (Abbott GmbH & Co. KG) dynamic HBsAg tests in 15 HBV seroconversion panels. RESULTS: The 95 percent detection limits (and 95% confidence interval [CI]) on the WHO International Standards was 26 (16-58) IU per mL for HIV-1 RNA, 4.6 (3.7-6.5) IU per mL for HCV RNA, and 11 (7.3-22) IU per mL for HBV DNA. No cross-contamination was observed. Testing 2912 pools of eight donations revealed 16 initial reactive samples; 11 were confirmed. The specificity after initial testing and percentage of invalid results were 99.83 and 0.48 percent, respectively. The HBV window-period (WP) reductions relative to HBsAg seroconversion in Prism and Auszyme dynamic HBsAg were, respectively, 6 days (95% CI, 3-8) and 9 days (95% CI, 7-12) in 1:8 minipool (MP) testing. CONCLUSION: The performance characteristics of Procleix Ultrio assay and the Procleix HIV-1 and HCV assay are comparable. The sensitivity for HIV-1 and HCV met the directives of the Paul-Ehrlich Institute and the FDA. The assay can reduce the WP for HBV by 6 days to 2 weeks when used in small MP (<1:8) or single-donation screening protocols.


Asunto(s)
Donantes de Sangre , ADN Viral/sangre , VIH-1/aislamiento & purificación , Hepacivirus/aislamiento & purificación , Virus de la Hepatitis B/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/sangre , Genotipo , VIH-1/genética , Hepacivirus/genética , Virus de la Hepatitis B/genética , Humanos , Sensibilidad y Especificidad
3.
Transfusion ; 42(5): 537-48, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12084161

RESUMEN

BACKGROUND: Blood transfusion centers around the world have introduced minipool NAT to reduce the risk of HBV, HCV, and HIV transmission by blood donations drawn in the infectious window phase. What would be the reduction in the residual risk when minipool NAT would be replaced by single-donation NAT? STUDY DESIGN AND METHODS: A mathematic model was developed to estimate the probability of virus transmission by blood transfusion when NAT screening methods are used for virologic safety testing. The major assumptions used are threefold: 1) The viral nucleic acid concentrations in the early window phase of infection double in 2.8 (HBV), 0.74 (HCV), and 0.90 (HIV) days. 2) The detectability of low copy numbers of viral DNA or RNA by the screening assay can be described with a probit model. 3) The probability of infection depends linearly on the logarithm of the administered dose, with 50-percent infectivity rates at 10 (HBV and HCV) or 1000 (HIV) viral nucleic acid copies per transfusion unit (estimates based on NAT studies with samples of known infectivity in chimpanzees). RESULTS: A reasonably simple equation was obtained that allows studying the effect of the sensitivity of the NAT assay and of the pool size used for screening on the residual risk of transfusion-transmitted infection. The computations are illustrated by using observed sensitivity estimates of various NAT methods. By using epidemiologic data among European donors over 1997 as baseline, the calculations predict that the incidence of virus transmission per 10-million RBC transfusions reduces with the following numbers when lowering the test pool size from 96 to 1 (single-donation testing): HBV from 11 to 13 to 3.3 to 5.1, HCV from 1.7 to 2.0 to 0.5 to 0.8, and HIV from 0.47 to 0.62 to 0.010 to 0.045 (ranges for the different NAT screening methods). CONCLUSION: A proper mathematic model for the calculation of residual infection risk by blood transfusion helps understand the impact of introducing new NAT methods for blood safety testing.


Asunto(s)
Transfusión Sanguínea/normas , Amplificación de Genes , Infecciones por VIH/transmisión , Hepatitis B/transmisión , Hepatitis C/transmisión , Modelos Teóricos , ARN Viral/sangre , Viremia/diagnóstico , Donantes de Sangre , Europa (Continente) , Reacciones Falso Negativas , VIH/genética , VIH/aislamiento & purificación , Infecciones por VIH/epidemiología , Hepacivirus/genética , Hepacivirus/aislamiento & purificación , Hepatitis B/epidemiología , Virus de la Hepatitis B/genética , Virus de la Hepatitis B/aislamiento & purificación , Hepatitis C/epidemiología , Humanos , Incidencia , Probabilidad , Medición de Riesgo/estadística & datos numéricos , Seguridad , Sensibilidad y Especificidad , Reacción a la Transfusión , Carga Viral , Replicación Viral
4.
Transfusion ; 42(5): 527-36, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12084160

RESUMEN

BACKGROUND: The FDA requirement for sensitivity of viral NAT methods used in blood screening is a 95-percent detection limit of 100 copies per mL, whereas the NAT screening system should have a sensitivity of at least 5000 copies per mL per individual donation. According to the Common Technical Specifications of the European Directive 98/79/EC for in vitro diagnostics, viral standard dilutions (calibrated against the WHO standard) should be tested at least 24 times for a statistically valid assessment of the 95-percent detection limit. STUDY DESIGN AND METHODS: Viral standard dilution panels (PeliCheck, VQC-CLB) were prepared for HCV RNA genotypes 1 and 3 and for HIV RNA genotypes B and E. In a multicenter study, 23 laboratories tested the panels all together in 8 to 91 test runs per NAT method. RESULTS: The following 95-percent detection limits (and 95% CIs) were found on the HCV RNA genotype 1 reference panels (shown as geq/mL): Gen-Probe TMA, 85 (64-118); AmpliScreen, 126 (83-225); AmpliScreen with NucliSens Extractor, 21 (13-44); Amplicor with NucliSens Extractor, 69 (50-102), and Amplicor with Qiagen extraction technology, 144 (74-102). On HIV RNA genotype B dilution panels, the following 95-percent detection limits were found (shown as geq/mL): Gen-Probe TMA, 31 (20-52); AmpliScreen, 126 (67-311); AmpliScreen with NucliSens Extractor, 37 (23-69), and NucliSens QL assay, 123 (51-566). HIV RNA genotype E panels were detected with equal sensitivity as HIV RNA genotype B panels. In the Gen-Probe TMA assay, the 50-percent detection limits on HIV RNA type B and type E were 3.6 (2.6-5.0) and 3.9 (2.4-5.8) geq per mL, respectively. The HCV RNA genotype 1 and 3 standards were detected with equal sensitivity. CONCLUSION: The differences in sensitivity between NAT assays can be explained by the input of isolated viral nucleic acid in the amplification reactions. The FDA requirements for sensitivity of NAT blood screening assays can be met by the Gen-probe TMA, as well as by the AmpliScreen assays, particularly when combined with the NucliSens Extractor.


Asunto(s)
Transfusión Sanguínea/normas , VIH/aislamiento & purificación , Hepacivirus/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/sangre , Juego de Reactivos para Diagnóstico/normas , Viremia/diagnóstico , Adsorción , Australia , Automatización , Europa (Continente) , Genotipo , VIH/genética , Hepacivirus/genética , Humanos , Magnetismo , ARN Viral/aislamiento & purificación , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Dióxido de Silicio , Transcripción Genética , Ultracentrifugación , Estados Unidos , United States Food and Drug Administration , Viremia/virología
5.
Transfusion ; 42(6): 792-7, 2002 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12147034

RESUMEN

BACKGROUND: Routine HCV NAT minipool screening (48 donations) of all blood donations was implemented in July 1999 and was combined with HIV NAT in November 2000. This report describes the validation of the NAT methods and the results of quality control testing. STUDY DESIGN AND METHODS: Nucleic acid was extracted from 2-mL plasma samples by using an automated silica-based extraction method (NucliSens Extractor, Organon Teknika). Eluates were tested with RT-PCR (AmpliScreen HIV-1 version 1.5 and AmpliScreen HCV version 2.0 test, Roche Diagnostic Systems). HIV-1 and HCV RNA reference panels and run controls (PeliCheck and PeliSpy, respectively, Sanquin-CLB) and human plasma minipools were used for NAT validation. RESULTS: The 95-percent detection limit (and 95% CI) for HIV-1 RNA genotype B, HIV-1 RNA genotype E, and HCV RNA genotype 1 was 32 (19-76), 30 (17-72), and 21 (13-44) genome equivalents (geq) per mL, respectively. During initial validation, 2332 samples for HIV-1 RNA and 2644 samples for HCV RNA were analyzed, with 13 (0.56%) and 12 (0.45%) invalid test results, respectively. Thereafter, over 19,600 samples (minipools and run controls) were analyzed during the first 11 months of routine screening. Invalid test results for HIV-1 RNA and HCV RNA were found in 1.1 and 1.07 percent of the samples tested, respectively. HIV-1 RNA minipool testing resulted in 27 (0.16%) initial false-positive results and 3 (0.02%) confirmed positive results. HCV RNA minipool testing resulted in four (0.02%) initial false-positive results and five (0.02%) confirmed positive results. CONCLUSION: Routine HIV and HCV NAT minipool screening using the NucliSens Extractor, AmpliScreen HIV-1 version 1.5, and AmpliScreen HCV version 2.0 meets the sensitivity criteria set by the regulatory bodies and provides sufficient specificity and robustness for timely release of blood donations.


Asunto(s)
Donantes de Sangre , Infecciones por VIH/diagnóstico , Hepatitis C/diagnóstico , Tamizaje Masivo/instrumentación , Técnicas de Amplificación de Ácido Nucleico/instrumentación , ARN Viral/sangre , Viremia/diagnóstico , Adsorción , Reacciones Falso Positivas , Genotipo , Infecciones por VIH/sangre , VIH-1/clasificación , VIH-1/genética , VIH-1/aislamiento & purificación , Hepacivirus/clasificación , Hepacivirus/genética , Hepacivirus/aislamiento & purificación , Hepatitis C/sangre , Humanos , Tamizaje Masivo/métodos , Países Bajos , ARN Viral/aislamiento & purificación , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación , Sensibilidad y Especificidad , Dióxido de Silicio , Viremia/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA