Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38881496

RESUMEN

BACKGROUND: Artificial intelligence, particularly deep learning (DL), has immense potential to improve the interpretation of transthoracic echocardiography (TTE). Mitral regurgitation (MR) is the most common valvular heart disease and presents unique challenges for DL, including the integration of multiple video-level assessments into a final study-level classification. METHODS: A novel DL system was developed to intake complete TTEs, identify color MR Doppler videos, and determine MR severity on a 4-step ordinal scale (none/trace, mild, moderate, and severe) using the reading cardiologist as a reference standard. This DL system was tested in internal and external test sets with performance assessed by agreement with the reading cardiologist, weighted κ, and area under the receiver-operating characteristic curve for binary classification of both moderate or greater and severe MR. In addition to the primary 4-step model, a 6-step MR assessment model was studied with the addition of the intermediate MR classes of mild-moderate and moderate-severe with performance assessed by both exact agreement and ±1 step agreement with the clinical MR interpretation. RESULTS: A total of 61 689 TTEs were split into train (n=43 811), validation (n=8891), and internal test (n=8987) sets with an additional external test set of 8208 TTEs. The model had high performance in MR classification in internal (exact accuracy, 82%; κ=0.84; area under the receiver-operating characteristic curve, 0.98 for moderate/severe MR) and external test sets (exact accuracy, 79%; κ=0.80; area under the receiver-operating characteristic curve, 0.98 for moderate or greater MR). Most (63% internal and 66% external) misclassification disagreements were between none/trace and mild MR. MR classification accuracy was slightly higher using multiple TTE views (accuracy, 82%) than with only apical 4-chamber views (accuracy, 80%). In subset analyses, the model was accurate in the classification of both primary and secondary MR with slightly lower performance in cases of eccentric MR. In the analysis of the 6-step classification system, the exact accuracy was 80% and 76% with a ±1 step agreement of 99% and 98% in the internal and external test set, respectively. CONCLUSIONS: This end-to-end DL system can intake entire echocardiogram studies to accurately classify MR severity and may be useful in helping clinicians refine MR assessments.

2.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

4.
Catheter Cardiovasc Interv ; 104(2): 227-233, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38932577

RESUMEN

BACKGROUND: Coronary angiography and percutaneous coronary intervention (PCI) in patients with chronic kidney disease (CKD) is associated with increased risk of contrast induced nephropathy (CIN) and requirement for renal replacement therapy (RRT). OBJECTIVES: We aimed to evaluate our single center experience of ultra-low contrast PCI in patients with CKD and to characterize 1 year outcomes. METHODS: We performed a retrospective analysis of ultra-low contrast PCI at our institution between 2016 and 2022. Patients with CKD3b-5 (eGFR <45 mL/min/1.73m2), not on RRT who underwent ultra-low contrast PCI ( < 30 mL of contrast during PCI) were included. Primary outcomes included change in eGFR post-procedurally, and death, RRT requirement, and major adverse cardiac events (MACE) at 1 year follow-up. RESULTS: One hundred patients were included in the study. The median age was 67 years old and 28% were female. The median baseline eGFR was 21.5 mL/min/1.73m2 (IQR 14.08-32.0 mL/min/1.73m2). A median of 8.0 mL (IQR 0-15 mL) of contrast was used during PCI. Median contrast use to eGFR ratio was 0.37 (IQR 0-0.59). There was no significant difference between pre-and postprocedure eGFR (p = 0.84). At 1 year, 8% of patients died, 11% required RRT and 33% experienced MACE. The average time of RRT initiation was 7 months post-PCI. Forty-four patients were undergoing renal transplant evaluation, of which 17 (39%) received a transplant. CONCLUSIONS: In patients with advanced CKD, ultra-low contrast PCI is feasible and safe with minimal need for peri-procedural RRT. Moreover, ultra-low contrast PCI may allow for preservation of renal function in anticipation of renal transplantation.


Asunto(s)
Medios de Contraste , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Tasa de Filtración Glomerular , Riñón , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica , Terapia de Reemplazo Renal , Humanos , Femenino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Masculino , Estudios Retrospectivos , Insuficiencia Renal Crónica/terapia , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/mortalidad , Anciano , Medios de Contraste/efectos adversos , Medios de Contraste/administración & dosificación , Resultado del Tratamiento , Persona de Mediana Edad , Factores de Tiempo , Factores de Riesgo , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/complicaciones , Medición de Riesgo , Riñón/fisiopatología
6.
J Am Coll Cardiol ; 84(3): 276-294, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38986670

RESUMEN

BACKGROUND: Complete revascularization with percutaneous coronary intervention improves outcomes compared with culprit revascularization following myocardial infarction (MI) with multivessel coronary artery disease. An all-cause mortality reduction has never been demonstrated. Debate also remains regarding the optimal timing of complete revascularization (immediate or staged), and method of evaluation of nonculprit lesions (physiology or angiography). OBJECTIVES: This study aims to perform an updated systematic review with frequentist and Bayesian network meta-analyses including the totality of randomized data investigating revascularization strategies in patients presenting with MI and multivessel coronary artery disease. METHODS: The primary comparison tested complete vs culprit revascularization. Timing and methods of achieving complete revascularization were assessed. The prespecified primary outcome was all-cause mortality. Outcomes were expressed as relative risk (RR) (95% CI). RESULTS: Twenty-four eligible trials randomized 16,371 patients (weighted mean follow-up: 26.4 months). Compared with culprit revascularization, complete revascularization reduced all-cause mortality in patients with any MI (RR: 0.85; 95% CI: 0.74-0.99; P = 0.04). Cardiovascular mortality, MI, major adverse cardiac events and repeat revascularization were also significantly reduced. In patients presenting with ST-segment elevation myocardial infarction, the point estimate for all-cause mortality with complete revascularization was RR: 0.91 (95% CI: 0.78-1.05; P = 0.18). Rates of stent thrombosis, major bleeding, and acute kidney injury were similar. Immediate complete revascularization ranked higher than staged complete revascularization for all endpoints. CONCLUSIONS: Complete revascularization following MI reduces all-cause mortality, cardiovascular mortality, MI, major adverse cardiac events, and repeat revascularization. There may be benefits to immediate complete revascularization, but additional head-to-head trials are needed.


Asunto(s)
Infarto del Miocardio , Metaanálisis en Red , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio/cirugía , Infarto del Miocardio/mortalidad , Infarto del Miocardio/terapia
7.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938841

RESUMEN

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

8.
JACC Adv ; 3(5): 100959, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939639

RESUMEN

Background: The prognostic value of cardiac damage staging classification based on the extent of extravalvular damage has been proposed in moderate/severe aortic stenosis (AS). Objectives: The purpose of this study was to assess the association of cardiac damage staging with mortality across the spectrum of patients with AS following aortic surgical or transcatheter aortic valve replacement (AVR). Methods: We conducted a pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies published through February 2023. Results: In total, 16 studies (n = 14,499) met our eligibility criteria and included 12,282 patients with symptomatic severe AS and 2,217 patients with asymptomatic severe/moderate AS. For patients with symptomatic severe AS, all-cause mortality was 24.0%, 27.7%, 38.0%, 56.3%, and 57.3% at 5 years in patients with cardiac damage stage 0, 1, 2, 3, and 4, respectively (stage 0 as reference; HR in stage 1: 1.30 [95% CI: 1.03-1.64]; P = 0.029; stage 2: 1.74 [95% CI: 1.41-2.16]; P < 0.001; stage 3: 2.92 [95% CI: 2.35-3.64]; P < 0.001, and stage 4: 3.51 [95% CI: 2.79-4.41]; P < 0.001). For patients with asymptomatic moderate/severe AS, all-cause mortality was 19.3%, 36.9%, 51.7%, and 67.8% at 8 years in patients with cardiac damage stage 0, 1, 2, and 3 to 4, respectively (HR in stage 1: 1.70 [95% CI: 1.21-2.38]; P = 0.002; stage 2: 2.20 [95% CI: 1.60-3.02]; P < 0.001; and stage 3 to 4: 3.90 [95% CI: 2.79-5.47]; P < 0.001). Conclusions: In patients undergoing AVR across the symptomatic and severity spectrum of AS, cardiac damage staging at baseline has important prognostic implications. This pooled meta-analysis in patients undergoing AVR suggests that staging of baseline cardiac damage could be considered for timing and selection of therapy in patients with moderate or severe AS to determine the need for earlier AVR or adjunctive pharmacotherapy to prevent irreversible cardiac damage and improve the long-term prognosis.

9.
Front Immunol ; 15: 1258369, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38933266

RESUMEN

Autoantigen-specific immunotherapy using peptides offers a more targeted approach to treat autoimmune diseases, but clinical implementation has been challenging. We previously showed that multivalent delivery of peptides as soluble antigen arrays (SAgAs) efficiently protects against spontaneous autoimmune diabetes in the non-obese diabetic (NOD) mouse model. Here, we compared the efficacy, safety, and mechanisms of action of SAgAs versus free peptides. SAgAs, but not their corresponding free peptides at equivalent doses, efficiently prevented the development of diabetes. SAgAs increased the frequency of regulatory T cells among peptide-specific T cells or induce their anergy/exhaustion or deletion, depending on the type of SAgA used (hydrolysable (hSAgA) and non-hydrolysable 'click' SAgA (cSAgA)) and duration of treatment, whereas their corresponding free peptides induced a more effector phenotype following delayed clonal expansion. Over time, the peptides induced an IgE-independent anaphylactic reaction, the incidence of which was significantly delayed when peptides were in SAgA form rather than in free form. Moreover, the N-terminal modification of peptides with aminooxy or alkyne linkers, which was needed for grafting onto hyaluronic acid to make hSAgA or cSAgA variants, respectively, influenced their stimulatory potency and safety, with alkyne-functionalized peptides being more potent and less anaphylactogenic than aminooxy-functionalized peptides. Immunologic anaphylaxis occurred in NOD mice in a dose-dependent manner but not in C57BL/6 or BALB/c mice; however, its incidence did not correlate with the level of anti-peptide antibodies. We provide evidence that SAgAs significantly improve the efficacy of peptides to induce tolerance and prevent autoimmune diabetes while at the same time reducing their anaphylactogenic potential.


Asunto(s)
Diabetes Mellitus Tipo 1 , Tolerancia Inmunológica , Ratones Endogámicos NOD , Péptidos , Animales , Ratones , Diabetes Mellitus Tipo 1/inmunología , Péptidos/inmunología , Péptidos/administración & dosificación , Femenino , Autoantígenos/inmunología , Linfocitos T Reguladores/inmunología , Inmunoterapia/métodos , Anafilaxia/prevención & control , Anafilaxia/inmunología , Desensibilización Inmunológica/métodos , Desensibilización Inmunológica/efectos adversos
10.
J Am Coll Cardiol ; 84(8): 712-722, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39142725

RESUMEN

BACKGROUND: Acute brain infarction detected by diffusion-weighted magnetic resonance imaging (DW-MRI) is common after transcatheter aortic valve replacement (TAVR), but its clinical relevance is uncertain. OBJECTIVES: The authors investigated the relationship between DW-MRI total lesion number (TLN), individual lesion volume (ILV), and total lesion volume (TLV) and clinical stroke outcomes after TAVR. METHODS: Patient-level data were pooled from 4 prospective TAVR embolic protection studies, with consistent predischarge DW-MRI acquisition and core laboratory analysis. C-statistic was used to determine the best DW-MRI measure associated with clinical stroke. RESULTS: A total of 495 of 603 patients undergoing TAVR completed the predischarge DW-MRI. At 30 days, the rate of clinical ischemic stroke was 6.9%. Acute ischemic brain injury was seen in 85% of patients with 5.5 ± 7.3 discrete lesions per patient, mean ILV of 78.2 ± 257.1 mm3, and mean TLV of 555 ± 1,039 mm3. The C-statistic was 0.84 for TLV, 0.81 for number of lesions, and 0.82 for maximum ILV in predicting ischemic stroke. On the basis of the TLV cutpoint as defined by receiver operating characteristic (ROC), patients with a TLV >500 mm3 (vs TLV ≤500 mm3) had more ischemic stroke (18.2% vs 2.3%; P < 0.0001), more disabling strokes (8.8% vs 0.9%; P < 0.0001), and less complete stroke recovery (44% vs 62.5%; P = 0.001) at 30 days. CONCLUSIONS: Our study confirms that the number, size, and total volume of acute brain infarction defined by DW-MRI are each associated with clinical ischemic strokes, disabling strokes, and worse stroke recovery in patients undergoing TAVR and may have value as surrogate outcomes in stroke prevention trials. (A Prospective, Randomized Evaluation of the TriGuard™ HDH Embolic Deflection Device During TAVI [DEFLECT III]; NCT02070731) (A Study to Evaluate the Neuro-embolic Consequences of TAVR [NeuroTAVR]; NCT02073864) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT I]; NCT02536196) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT II]; NCT02536196).


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios Prospectivos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Accidente Cerebrovascular Isquémico/etiología , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Relevancia Clínica
11.
J Am Heart Assoc ; 13(2): e031111, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38214263

RESUMEN

BACKGROUND: Despite the initial evidence supporting the utility of intravascular imaging to guide percutaneous coronary intervention (PCI), adoption remains low. Recent new trial data have become available. An updated study-level meta-analysis comparing intravascular imaging to angiography to guide PCI was performed. This study aimed to evaluate the clinical outcomes of intravascular imaging-guided PCI compared with angiography-guided PCI. METHODS AND RESULTS: A random-effects meta-analysis was performed on the basis of the intention-to-treat principle. The primary outcomes were major adverse cardiac events, cardiac death, and all-cause death. Mixed-effects meta-regression was performed to investigate the impact of complex PCI on the primary outcomes. A total of 16 trials with 7814 patients were included. The weighted mean follow-up duration was 28.8 months. Intravascular imaging led to a lower risk of major adverse cardiac events (relative risk [RR], 0.67 [95% CI, 0.55-0.82]; P<0.001), cardiac death (RR, 0.49 [95% CI, 0.34-0.71]; P<0.001), stent thrombosis (RR, 0.63 [95% CI, 0.40-0.99]; P=0.046), target-lesion revascularization (RR, 0.67 [95% CI, 0.49-0.91]; P=0.01), and target-vessel revascularization (RR, 0.60 [95% CI, 0.45-0.80]; P<0.001). In complex lesion subsets, the point estimate for imaging-guided PCI compared with angiography-guided PCI for all-cause death was a RR of 0.75 (95% CI, 0.55-1.02; P=0.07). CONCLUSIONS: In patients undergoing PCI, intravascular imaging is associated with reductions in major adverse cardiac events, cardiac death, stent thrombosis, target-lesion revascularization, and target-vessel revascularization. The magnitude of benefit is large and consistent across all included studies. There may also be benefits in all-cause death, particularly in complex lesion subsets. These results support the use of intravascular imaging as standard of care and updates of clinical guidelines.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Trombosis , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Angiografía Coronaria/métodos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Ultrasonografía Intervencional/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Trombosis/etiología , Resultado del Tratamiento , Muerte
12.
JAMA Cardiol ; 9(7): 631-639, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38776106

RESUMEN

Importance: The use of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been rapidly expanding as an alternative treatment to redo surgical aortic valve replacement (SAVR) for failed bioprosthetic valves despite limited long-term data. Objective: To assess mortality and morbidity in patients undergoing intervention for failed bioprosthetic SAVR. Design, Setting, and Participants: This was a retrospective population-based cohort analysis conducted between January 1, 2015, and December 31, 2020, with a median (IQR) follow-up time of 2.3 (1.1-4.0) years. A total of 1771 patients with a history of bioprosthetic SAVR who underwent ViV-TAVR or redo SAVR in California, New York, and New Jersey were included. Data were obtained from the California Department of Health Care Access and Information, the New York Statewide Planning and Research Cooperative System, and the New Jersey Discharge Data Collection System. Exclusion criteria included undergoing TAVR or redo SAVR within 5 years from initial SAVR, as well as infective endocarditis, concomitant surgical procedures, and out-of-state residency. Propensity matching yielded 375 patient pairs. Data were analyzed from January to December 2023. Interventions: ViV-TAVR vs redo SAVR. Main Outcomes and Measurements: The primary outcome was all-cause mortality. Secondary outcomes were stroke, heart failure hospitalization, reoperation, major bleeding, acute kidney failure, new pacemaker insertion, and infective endocarditis. Results: From 2015 through 2020, the proportion of patients undergoing ViV-TAVR vs redo SAVR increased from 159 of 451 (35.3%) to 498 or 797 (62.5%). Of 1771 participants, 653 (36.9%) were female, and the mean (SD) age was 74.4 (11.3) years. Periprocedural mortality and stroke rates were similar between propensity-matched groups. The ViV-TAVR group had lower periprocedural rates of major bleeding (2.4% vs 5.1%; P = .05), acute kidney failure (1.3% vs 7.2%; P < .001), and new pacemaker implantations (3.5% vs 10.9%; P < .001). The 5-year all-cause mortality rate was 23.4% (95% CI, 15.7-34.1) in the ViV-TAVR group and 13.3% (95% CI, 9.2-18.9) in the redo SAVR group. In a landmark analysis, no difference in mortality was observed up to 2 years (hazard ratio, 1.03; 95% CI, 0.59-1.78), but after 2 years, ViV-TAVR was associated with higher mortality (hazard ratio, 2.97; 95% CI, 1.18-7.47) as well as with a higher incidence of heart failure hospitalization (hazard ratio, 3.81; 95% CI, 1.57-9.22). There were no differences in 5-year incidence of stroke, reoperation, major bleeding, or infective endocarditis. Conclusions and Relevance: Compared with redo SAVR, ViV-TAVR was associated with a lower incidence of periprocedural complications and a similar incidence of all-cause mortality through 2 years' follow-up. However, ViV-TAVR was associated with higher rates of late mortality and heart failure hospitalization. These findings may be influenced by residual confounding and require adjudication in a randomized clinical trial.


Asunto(s)
Bioprótesis , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Reoperación/estadística & datos numéricos , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/epidemiología , Falla de Prótesis , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
13.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866455

RESUMEN

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiología
14.
Circ Cardiovasc Interv ; 17(8): e013782, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39034924

RESUMEN

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Diseño de Prótesis , Falla de Prótesis , Recuperación de la Función , Humanos , Femenino , Masculino , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Anciano , Estudios Prospectivos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Factores de Riesgo , Persona de Mediana Edad , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Medición de Riesgo , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Estados Unidos , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Hemodinámica , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad
15.
Am J Med ; 137(4): 321-330.e7, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38190959

RESUMEN

PURPOSE: There are concerns that transcatheter or surgical aortic valve replacement (TAVR/SAVR) procedures are preferentially available to White patients. Our objective was to examine differences in utilization of aortic valve replacement and outcomes by race/ethnicity in the US for patients with aortic stenosis. METHODS: We performed a serial cross-sectional cohort study of 299,976 Medicare beneficiaries hospitalized with principal diagnosis of aortic stenosis between 2012 and 2019 stratified by self-reported race/ethnicity (Black, Hispanic, Asian, Native American, and White). Outcomes included aortic valve replacement rates within 6 months of index hospitalization and associated procedural outcomes, including 30-day readmission, 30-day and 1-year mortality. RESULTS: Within 6 months of an index admission for aortic stenosis, 86.8% (122,457 SAVR; 138,026 TAVR) patients underwent aortic valve replacement. Overall, compared with White people, Black (HR 0.87 [0.85-0.89]), Hispanic (0.92 [0.88-0.96]), and Asian (0.95 [0.91-0.99]) people were less likely to receive aortic valve replacement. Among patients who were admitted emergently/urgently, White patients (41.1%, 95% CI, 40.7-41.4) had a significantly higher aortic valve replacement rate compared with Black (29.6%, 95% CI, 28.3-30.9), Hispanic (36.6%, 95% CI, 34.0-39.3), and Asian patients (35.4%, 95% CI, 32.3-38.9). Aortic valve replacement rates increased annually for all race/ethnicities. There were no significant differences in 30-day or 1-year mortality by race/ethnicity. CONCLUSIONS: Aortic valve replacement rates within 6 months of aortic stenosis admission are lower for Black, Hispanic, and Asian people compared to White people. These race-related differences in aortic stenosis treatment reflect complex issues in diagnosis and management, warranting a comprehensive reassessment of the entire care spectrum for disadvantaged populations.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos/epidemiología , Válvula Aórtica/cirugía , Estudios Transversales , Medicare , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
16.
JACC Adv ; 3(3): 100839, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938839

RESUMEN

Background: Augmented reality (AR) guidance holds potential to improve transcatheter interventions by enabling visualization of and interaction with patient-specific 3-dimensional virtual content. Positioning of cerebral embolic protection devices (CEP) during transcatheter aortic valve replacement (TAVR) increases patient exposure to radiation and iodinated contrast, and increases procedure time. AR may enhance procedural guidance and facilitate a safer intervention. Objectives: The purpose of this study was to develop and test a novel AR guidance system with a custom user interface that displays virtual, patient-specific 3-dimensional anatomic models, and assess its intraprocedural impact during CEP placement in TAVR. Methods: Patients undergoing CEP during TAVR were prospectively enrolled and assigned to either AR guidance or control groups. Primary endpoints were contrast volume used prior to filter placement, times to filter placement, and fluoroscopy time. Postprocedure questionnaires were administered to assess intraprocedural physician experience with AR guidance. Results: A total of 24 patients presenting for TAVR were enrolled in the study (12 with AR guidance and 12 controls). AR guidance eliminated the need for aortic arch angiograms prior to device placement thus reducing contrast volume (0 mL vs 15 mL, P < 0.0001). There was no significant difference in the time required for filter placement or fluoroscopy time. Postprocedure questionnaires indicated that AR guidance increased confidence in wiring of the aortic arch and facilitated easier device placement. Conclusions: We developed a novel AR guidance system that eliminated the need for additional intraprocedural angiograms prior to device placement without any significant difference in time to intervention and offered a subjective improvement in performance of the intervention.

17.
Open Heart ; 11(1)2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38890129

RESUMEN

BACKGROUND: For high bleeding-risk patients (HBR) undergoing percutaneous coronary intervention (PCI), the LEADERS FREE (LF) and LEADERS FREE II (LF II) trials established the safety and efficacy of a stainless steel polymer-free biolimus-coated stent (SS-BCS) with 30 days of dual antiplatelet treatment (DAPT). The LEADERS FREE III (LF III) trial investigated clinical outcomes after PCI with the next-generation cobalt-chromium thin-strut polymer-free biolimus-coated stent (CoCr-BCS) in HBR patients. AIMS: To report the final 3-year results of the LF III trial and compare them to LF II. METHODS: LF III was a prospective, multicentre, open-label single-arm study to evaluate the safety and efficacy of the CoCr-BCS stent. The primary safety endpoint was the composite of cardiac death (CD), myocardial infarction(MI) or definite/probable stent thrombosis (ST). The primary efficacy endpoint was clinically driven target lesion revascularisation (cd-TLR). We performed a propensity-matched comparison to the 3-year outcomes of LF II. RESULTS: After 3 years, CD/MI/ST had occurred in 57 patients (15%, 95% CI 11.8% to 19%) and cd-TLR in 23 (6.2%, 95% CI 4.1% to 9.2%) patients. In a propensity-matched comparison of patients treated with the CoCr-BCS versus the SS-BCS, there were similar rates of CD (6.6% vs 7.8%, p=0.50), MI (7.1% vs 8.3%, p=0.47) and definite/probable ST (1.1% vs 2%, HR 0.56, 95% CI 0.16 to 1.93, p=0.35). The rates of cd-TLR were 5.3% with CoCr-BCS versus 9.8% with SS-BCS (HR 0.54, 95% CI 0.31 to 0.96, p=0.03). CONCLUSION: LF III confirms the long-term safety and efficacy of the CoCr-BCS in HBR patients treated with 1 month of DAPT. TRIAL REGISTRATION NUMBER: NCT02843633, NCT03118895.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Diseño de Prótesis , Sirolimus , Humanos , Masculino , Estudios Prospectivos , Femenino , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/efectos adversos , Sirolimus/análogos & derivados , Sirolimus/farmacología , Sirolimus/administración & dosificación , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico , Anciano , Factores de Tiempo , Persona de Mediana Edad , Estudios de Seguimiento , Inhibidores de Agregación Plaquetaria/uso terapéutico , Factores de Riesgo
18.
J Soc Cardiovasc Angiogr Interv ; 3(3Part A): 101262, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-39131776

RESUMEN

Background: While not available for clinical use in the United States, dedicated drug-coated balloons (DCB) are currently under investigation for the management of coronary in-stent restenosis (ISR). Peripheral drug-coated balloons (P-DCB) have been used off-label for coronary ISR. Further data regarding this practice are needed. We aimed to describe outcomes in patients who underwent off-label P-DCB angioplasty for coronary ISR. Methods: We analyzed data on P-DCB angioplasty for coronary ISR at a single high-volume center between April 1, 2015, and December 30, 2017. Demographic and procedural details were collected, with systematic follow-up as clinically indicated. Results: Data from 31 patients treated with P-DCB angioplasty (mean age 68.0 ± 10.7 years) with coronary ISR (17 recurrent and 14 first time) were analyzed. Most patients presented with high-grade angina (81%) or myocardial infarction (13%). Treated ISR lesions were in native coronary arteries (68%), saphenous vein grafts (SVG, 23%), and the left internal mammary artery (10%). Diffuse intrastent ISR was common (69%) with a mean lesion length of 21.7 ± 12.4 mm. No postprocedural myocardial infarction occurred and 1 nonprocedural mortality occurred during index admission. At follow-up (median: 283, interquartile range [IQR]: 354 days), repeat angiography was performed in 19 patients (median: 212, IQR: 188 days), and 11 patients had target lesion recurrent ISR (Kaplan-Meier event-free survival estimate: 44.7%, 95% CI, 26.1%-76.5%). Conclusions: In the absence of availability of dedicated coronary DCB, treatment of coronary ISR using P-DCB angioplasty was feasible, although follow-up demonstrated continued risk for recurrent ISR in this high-risk population.

19.
JACC Cardiovasc Interv ; 17(12): 1440-1451, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38639690

RESUMEN

BACKGROUND: Thirty-day outcomes with the investigational Intrepid transapical (TA) transcatheter mitral valve replacement (TMVR) system have previously demonstrated good technical success, but longer-term outcomes in larger cohorts need to be evaluated. OBJECTIVES: The authors sought to evaluate the 2-year safety and performance of the Intrepid TA-TMVR system in patients with symptomatic, ≥moderate-severe mitral regurgitation (MR) and high surgical risk. METHODS: Patient eligibility was determined by local heart teams and approved by a central screening committee. Clinical events were adjudicated by an independent clinical events committee. Echocardiography was evaluated by an independent core laboratory. RESULTS: The cohort included 252 patients that were enrolled at 58 international sites before February 2021 as part of the global Pilot Study (n = 95) or APOLLO trial (primary cohort noneligible + TA roll-ins, n = 157). Mean age was 74.2 years, mean STS-PROM was 6.3%, 60.3% were male, and 80.6% were in NYHA functional class III/IV. Most presented with secondary MR (70.1%), and nearly all had ≥moderate-severe MR (98.4%). All-cause mortality was 13.1% (30-day), 27.3% (1-year), and 36.2% (2-year). The 30-day ≥major bleeding event rate was 22.3%. Heart failure rehospitalization was 9.6% (30-day) and 36.2% (2-year). At 2 years, >50% of patients were alive with improvement in NYHA functional class (82.1%, class I/II), and all patients with available echocardiograms had ≤mild MR. CONCLUSIONS: This analysis represents the largest reported TA-TMVR experience with the longest follow-up in high-risk ≥moderate-severe MR patients. Early mortality and heart failure rehospitalizations were significant, exacerbated by early TA-related bleeding events; however, meaningful improvements in clinical outcomes and marked reductions in MR severity were observed through 2 years.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Femenino , Masculino , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Diseño de Prótesis , Valor Predictivo de las Pruebas , Complicaciones Posoperatorias/etiología , Persona de Mediana Edad , Hemodinámica , Readmisión del Paciente , Ecocardiografía
20.
Struct Heart ; 8(1): 100225, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38283566

RESUMEN

Background: Baseline left ventricular diastolic dysfunction (LVDD) is associated with poor health status in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR), but health status improvement after TAVR appears similar across all grades of LVDD. Here, we aim to examine the relationship between changes in LVDD severity and health status outcomes following TAVR. Methods: Patients who underwent TAVR and had evaluable LVDD at both baseline and 1 year in the PARTNER (Placement of Aortic Transcatheter Valves) 2 SAPIEN 3 registries and PARTNER 3 trial were analyzed. LVDD grade was evaluated using echocardiography core lab data and an adapted definition of American Society of Echocardiography guidelines. Health status was assessed using the Kansas City Cardiomyopathy Questionnaire Overall Summary (KCCQ-OS) score. The association between ΔLVDD severity and ΔKCCQ-OS was examined using linear regression models adjusted for baseline KCCQ-OS. Results: Of 1100 patients, 724 (65.8%), 283 (25.7%), and 93 (8.5%) had grade 0/1, 2, and 3 LVDD at baseline, respectively. At 1 year, LVDD severity was unchanged in 790 (71.8%) patients, improved in 189 (17.2%), and worsened in 121 (11.0%). Among 376 patients with baseline grade 2 or 3 LVDD, 50.3% had improvement in LVDD. In the overall cohort, KCCQ-OS score improved by 21.9 points at 1 year. There was a statistically significant association between change in LVDD severity (improved, unchanged, and worsened) and ΔKCCQ-OS at 1 year (p = 0.007). Conclusions: Change in LVDD grade was associated with change in health status 1 year following TAVR.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA