Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Small ; : e2401561, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899348

RESUMEN

Recreating the natural heart's mechanical and electrical environment is crucial for engineering functional cardiac tissue and repairing infarcted myocardium in vivo. In this study, multimaterial-printed serpentine microarchitectures are presented with synergistic mechanical/piezoelectric stimulation, incorporating polycaprolactone (PCL) microfibers for mechanical support, polyvinylidene fluoride (PVDF) microfibers for piezoelectric stimulation, and magnetic PCL/Fe3O4 for controlled deformation via an external magnet. Rat cardiomyocytes in piezoelectric constructs, subjected to dynamic mechanical stimulation, exhibit advanced maturation, featuring superior sarcomeric structures, improved calcium transients, and upregulated maturation genes compared to non-piezoelectric constructs. Furthermore, these engineered piezoelectric cardiac constructs demonstrate significant structural and functional repair of infarcted myocardium, as evidenced by enhanced ejection and shortening fraction, reduced fibrosis and inflammation, and increased angiogenesis. The findings underscore the therapeutic potential of piezoelectric cardiac constructs for myocardial infarction therapy.

2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 237-244, 2024 May 30.
Artículo en Zh | MEDLINE | ID: mdl-38863087

RESUMEN

Additive manufacturing (3D printing) technology aligns with the direction of precision and customization in future medicine, presenting a significant opportunity for innovative development in high-end medical devices. Currently, research and industrialization of 3D printed medical devices mainly focus on nondegradable implants and degradable implants. Primary areas including metallic orthopaedic implants, polyether-ether-ketone (PEEK) bone implants, and biodegradable implants have been developed for clinical and industrial application. Recent research achievements in these areas are reviewed, with a discussion on the additive manufacturing technologies and applications for customized implants. Challenges faced by different types of implants are analyzed from technological, application, and regulatory perspectives. Furthermore, prospects and suggestions for future development are outlined.


Asunto(s)
Impresión Tridimensional , Prótesis e Implantes , Benzofenonas , Polímeros , Humanos , Cetonas , Diseño de Prótesis , Materiales Biocompatibles , Polietilenglicoles , Implantes Absorbibles
3.
Trends Biotechnol ; 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38643041

RESUMEN

Nature-inspired microfluidic networks are revolutionizing microphysiological systems, allowing for the precise emulation of human physiology. This article delves into the fabrication techniques of leaf-venation-inspired (LVI) microfluidic networks and explores their transformative applications in organ-on-a-chip and tissue engineering, showcasing their pivotal role in advancing biomedical research.

4.
Nat Commun ; 15(1): 5261, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38898001

RESUMEN

Electric eel is an excellent example to harness ion-concentration gradients for sustainable power generation. However, current strategies to create electric-eel-inspired power sources commonly involve manual stacking of multiple salinity-gradient power source units, resulting in low efficiency, unstable contact, and poor flexibility. Here we propose a consecutive multimaterial printing strategy to efficiently fabricate biomimetic ionic hydrogel power sources with a maximum stretchability of 137%. The consecutively-printed ionic hydrogel power source filaments showed seamless bonding interface and can maintain stable voltage outputs for 1000 stretching cycles at 100% strain. With arrayed multi-channel printhead, power sources with a maximum voltage of 208 V can be automatically printed and assembled in parallel within 30 min. The as-printed flexible power source filaments can be woven into a wristband to power a digital wristwatch. The presented strategy provides a tool to efficiently produce electric-eel-inspired ionic hydrogel power sources with great stretchability for various flexible power source applications.

5.
ACS Appl Mater Interfaces ; 16(1): 1114-1128, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38133830

RESUMEN

Reliable insulation of microscale conductive features is required to fabricate functional multilayer circuits or flexible electronics for providing specific physical/chemical/electrical protection. However, the existing strategies commonly rely on manual assembling processes or multiple microfabrication processes, which is time-consuming and a great challenge for the fabrication of flexible transparent electronics with microscale features and ultrathin thickness. Here, we present a novel coaxial electrohydrodynamic (CEHD) printing strategy for the one-step fabrication of microscale flexible electronics with conductive materials at the core and insulating material at the outer layer. A finite element analysis (FEA) method is established to simulate the CEHD printing process. The extrusion sequence of the conductive and insulating materials during the CEHD printing process shows little effect on the morphology of the core-shell filaments, which can be achieved on different flexible substrates with a minimum conductive line width of 32 ± 3.2 µm, a total thickness of 53.6 ± 4.8 µm, and a conductivity of 0.23 × 107 S/m. The thin insulating layer can provide the inner conductive filament enough protection in 3D, which endows the resultant microscale core-shell electronics with good electrical stability when working in different chemical solvent solutions or under large deformation conditions. Moreover, the presented CEHD printing strategy offers a unique capability to sequentially fabricate an insulating layer, core-shell conductive pattern, and exposed electrodes by simply controlling the material extrusion sequence. The resultant large-area transparent electronics with two-layer core-shell patterns exhibit a high transmittance of 98% and excellent electrothermal performance. The CEHD-printed flexible microelectrode array is successfully used to record the electrical signals of beating mouse hearts. It can also be used to fabricate large-area flexible capacitive sensors to accurately measure the periodical pressure force. We envision that the present CEHD printing strategy can provide a promising tool to fabricate complex three-dimensional electronics with microscale resolution, high flexibility, and multiple functionalities.

6.
iScience ; 27(2): 108757, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38313046

RESUMEN

The survival outcomes of patients with chest wall sarcomas (CWS) were evaluated after receiving wide excision and chest wall reconstruction by using three-dimensional printed (3DP) implants. The survival outcomes evaluating the effect of 3DP implants for chest wall reconstruction is lacking. Here, forty-nine patients with CWS underwent radical wide excision and chest wall reconstruction using 3DP implants. The surgical data and long-term survival outcomes were collected and analyzed. With a median follow-up of 36 months, the disease-free survival (DFS) and overall survival (OS) were 31.7% and 58.5%, respectively. In addition, the 3-year DFS and OS can be significantly differentiated using the classification criteria of tumor grade, tumor size tumor area. Hence, wide excision and chest wall reconstruction using three-dimensional printed implants are a safe and effective treatment for chest wall sarcoma. The novel classification criteria of tumor size and area have the potential to predict the prognosis of CWS.

7.
Biomater Adv ; 161: 213888, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38759305

RESUMEN

Short carbon fiber (SCF) reinforced polymer composites are expected to possess outstanding biotribological and mechanical properties in certain direction, while the non-oriented SCF weakens its reinforcing effect in the matrix. In this work, high-oriented SCF was achieved during nozzle extrusion, and then SCF reinforced polyether-ether-ketone (PEEK) composites were fabricated by fused deposition modeling (FDM). The concrete orientation process of SCF was theoretically simulated, and significant shear stress difference was generated at both ends of SCF. As a result, the SCF was distributed in the matrix in a hierarchical structure, containing surface layer I, II and core layer. Moreover, the SCF was oriented highly along the printing direction and demonstrated a more competitive orientation distribution compared to other studies. The SCF/PEEK composites showed a considerable improvement in wear resistance by 44 % due to self-lubricating and load-bearing capability of SCF. Besides, it demonstrated enhancements in Brinell hardness, compressive and impact strength by 48.52 %, 16.42 % and 53.64 %, respectively. In addition, SCF/PEEK composites also showed good cytocompatibility. The findings gained herein are useful for developing the high-oriented SCF reinforced polymer composites with superior biotribological and mechanical properties for artificial joints.


Asunto(s)
Benzofenonas , Fibra de Carbono , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Impresión Tridimensional , Fibra de Carbono/química , Polímeros/química , Polietilenglicoles/química , Cetonas/química , Ensayo de Materiales/métodos , Materiales Biocompatibles/química , Prótesis Articulares , Humanos
8.
Mater Today Bio ; 28: 101176, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39171099

RESUMEN

The lack of accurate and reliable in vitro brain models hinders the development of brain science and research on brain diseases. Owing to the complex structure of the brain tissue and its highly nonlinear characteristics, the construction of brain-like in vitro tissue models remains one of the most challenging research fields in the construction of living tissues. This study proposes a multi-scale design of a brain-like model with a biomimetic cortical structure, which includes the macroscopic structural features of six layers of different cellular components, as well as micrometer-scale continuous fiber structures running through all layers vertically. To achieve integrated biomanufacturing of such a complex multi-scale brain-like model, a multi-material composite printing/culturing integrated bioprinting platform was developed in-house by integrating cell-laden hydrogel ink direct writing printing and electrohydrodynamic fiber 3D printing technologies. Through integrated bioprinting, multi-scale models with different cellular components and fiber structural parameters were prepared to study the effects of macroscopic and microscopic structural features on the directionality of neural cells, as well as the interaction between glial cells and neurons within the tissue model in a three-dimensional manner. The results revealed that the manufactured in vitro biomimetic cortical model achieved morphological connections between the layers of neurons, reflecting the structure and cellular morphology of the natural cortex. Micrometer-scale (10 µm) cross-layer fibers effectively guided and controlled the extension length and direction of the neurites of surrounding neural cells but had no significant effect on the migration of neurons. In contrast, glial cells significantly promoted the migration of surrounding PC12 cells towards the glial layer but did not contribute to the extension of neurites. This study provides a basis for the design and manufacture of accurate brain-like models for the functionalization of neuronal tissues.

9.
Mater Today Bio ; 24: 100914, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38179431

RESUMEN

Recent advances in heart-on-a-chip systems hold great promise to facilitate cardiac physiological, pathological, and pharmacological studies. This review focuses on the development of heart-on-a-chip systems with tissue-specific functionalities. For one thing, the strategies for developing cardiac microtissues on heart-on-a-chip systems that closely mimic the structures and behaviors of the native heart are analyzed, including the imitation of cardiac structural and functional characteristics. For another, the development of techniques for real-time monitoring of biophysical and biochemical signals from cardiac microtissues on heart-on-a-chip systems is introduced, incorporating cardiac electrophysiological signals, contractile activity, and biomarkers. Furthermore, the applications of heart-on-a-chip systems in intelligent cardiac studies are discussed regarding physiological/pathological research and pharmacological assessment. Finally, the future development of heart-on-a-chip toward a higher level of systematization, integration, and maturation is proposed.

10.
Adv Sci (Weinh) ; 11(10): e2308137, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38145964

RESUMEN

The increasing needs for new types of computing lie in the requirements in harsh environments. In this study, the successful development of a non-electrical neural network is presented that functions based on mechanical computing. By overcoming the challenges of low mechanical signal transmission efficiency and intricate layout design methodologies, a mechanical neural network based on bistable kirigami-based mechanical metamaterials have designed. In preliminary tests, the system exhibits high reliability in recognizing handwritten digits and proves operable in low-temperature environments. This work paves the way for a new, alternative computing system with broad applications in areas where electricity is not accessible. By integrating with the traditional electronic computers, the present system lays the foundation for a more diversified form of computing.

11.
Materials (Basel) ; 16(24)2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38138710

RESUMEN

Porous tantalum (Ta) implants have important clinical application prospects due to their appropriate elastic modulus, and their excellent bone growth and bone conduction ability. However, porous Ta microstructure designs generally mimic titanium (Ti) implants commonly used in the clinic, and there is a lack of research on the influence of the microstructure on the mechanical properties and penetration characteristics, which will greatly affect bone integration performance. This study explored the effects of different microstructure parameters, including the fillet radius of the middle plane and top planes, on the mechanics and permeability properties of porous Ta diamond cells through simulation, and put forward an optimization design with a 0.5 mm midplane fillet radius and 0.3 mm top-plane fillet radius in order to significantly decrease the stress concentration effect and improve permeability. On this basis, the porous Ta structures were prepared by Laser Powder Bed Fusion (LPBF) technology and evaluated before and after microstructural optimization. The elastic modulus and the yield strength were increased by 2.31% and 10.39%, respectively. At the same time, the permeability of the optimized structure was also increased by 8.25%. The optimized microstructure design of porous Ta has important medical application value.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA