Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Nature ; 629(8013): 810-818, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38778234

RESUMEN

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Asunto(s)
Velocidad del Flujo Sanguíneo , Encéfalo , Circulación Cerebrovascular , Ultrasonografía , Humanos , Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Circulación Cerebrovascular/fisiología , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Errores Médicos , Relación Señal-Ruido , Piel , Cráneo , Somnolencia/fisiología , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Adulto
2.
Nature ; 613(7945): 667-675, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36697864

RESUMEN

Continuous imaging of cardiac functions is highly desirable for the assessment of long-term cardiovascular health, detection of acute cardiac dysfunction and clinical management of critically ill or surgical patients1-4. However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness5-11, and existing wearable cardiac devices can only capture signals on the skin12-16. Here we report a wearable ultrasonic device for continuous, real-time and direct cardiac function assessment. We introduce innovations in device design and material fabrication that improve the mechanical coupling between the device and human skin, allowing the left ventricle to be examined from different views during motion. We also develop a deep learning model that automatically extracts the left ventricular volume from the continuous image recording, yielding waveforms of key cardiac performance indices such as stroke volume, cardiac output and ejection fraction. This technology enables dynamic wearable monitoring of cardiac performance with substantially improved accuracy in various environments.


Asunto(s)
Ecocardiografía , Diseño de Equipo , Corazón , Dispositivos Electrónicos Vestibles , Humanos , Gasto Cardíaco , Ecocardiografía/instrumentación , Ecocardiografía/normas , Corazón/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Dispositivos Electrónicos Vestibles/normas , Piel
3.
Nature ; 577(7789): 209-215, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31915395

RESUMEN

Strain engineering is a powerful tool with which to enhance semiconductor device performance1,2. Halide perovskites have shown great promise in device applications owing to their remarkable electronic and optoelectronic properties3-5. Although applying strain to halide perovskites has been frequently attempted, including using hydrostatic pressurization6-8, electrostriction9, annealing10-12, van der Waals force13, thermal expansion mismatch14, and heat-induced substrate phase transition15, the controllable and device-compatible strain engineering of halide perovskites by chemical epitaxy remains a challenge, owing to the absence of suitable lattice-mismatched epitaxial substrates. Here we report the strained epitaxial growth of halide perovskite single-crystal thin films on lattice-mismatched halide perovskite substrates. We investigated strain engineering of α-formamidinium lead iodide (α-FAPbI3) using both experimental techniques and theoretical calculations. By tailoring the substrate composition-and therefore its lattice parameter-a compressive strain as high as 2.4 per cent is applied to the epitaxial α-FAPbI3 thin film. We demonstrate that this strain effectively changes the crystal structure, reduces the bandgap and increases the hole mobility of α-FAPbI3. Strained epitaxy is also shown to have a substantial stabilization effect on the α-FAPbI3 phase owing to the synergistic effects of epitaxial stabilization and strain neutralization. As an example, strain engineering is applied to enhance the performance of an α-FAPbI3-based photodetector.

4.
Nature ; 583(7818): 790-795, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32728239

RESUMEN

Organic-inorganic hybrid perovskites have electronic and optoelectronic properties that make them appealing in many device applications1-4. Although many approaches focus on polycrystalline materials5-7, single-crystal hybrid perovskites show improved carrier transport and enhanced stability over their polycrystalline counterparts, due to their orientation-dependent transport behaviour8-10 and lower defect concentrations11,12. However, the fabrication of single-crystal hybrid perovskites, and controlling their morphology and composition, are challenging12. Here we report a solution-based lithography-assisted epitaxial-growth-and-transfer method for fabricating single-crystal hybrid perovskites on arbitrary substrates, with precise control of their thickness (from about 600 nanometres to about 100 micrometres), area (continuous thin films up to about 5.5 centimetres by 5.5 centimetres), and composition gradient in the thickness direction (for example, from methylammonium lead iodide, MAPbI3, to MAPb0.5Sn0.5I3). The transferred single-crystal hybrid perovskites are of comparable quality to those directly grown on epitaxial substrates, and are mechanically flexible depending on the thickness. Lead-tin gradient alloying allows the formation of a graded electronic bandgap, which increases the carrier mobility and impedes carrier recombination. Devices based on these single-crystal hybrid perovskites show not only high stability against various degradation factors but also good performance (for example, solar cells based on lead-tin-gradient structures with an average efficiency of 18.77 per cent).

5.
J Environ Manage ; 314: 115104, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35462257

RESUMEN

This paper reviews the literature on crop residue burning - a widespread practice in many regions in South Asia. Specifically, we examine evidence from studies highlighting the scale of the practice in South Asia, the environmental implications, the drivers of the practice and the remedies to the problem. The studies provide evidence that the Indo-Gangetic Plain (IGP) is a hot-spot for atmospheric pollutants, with seasonal crop residue burning being a major contributor. The burning of crop residue is reported to degrade the soil, increase the risk of erosion, and increase the soil temperature, consequently decimating soil microorganisms. This subsequently impacts the monetary cost involved in recovering the soil fertility and the potential for further pollution through the increased use of fertilizer. The review shows that farmers' reasons for burning crop residues are mainly the high cost of incorporating, collecting, transporting, and processing crop residues in South Asia. Labour shortages, the marketability of the crop residue and the short time interval between harvest and next cropping seasons also influence farmers decision to burn crop residue. To address this problem, there is the need to encourage the use of agricultural machines capable of sowing crops in standing stubble, adopting in-situ practices and changing crop varieties to those with short duration. In addition, education and awareness are needed to change beliefs and perceptions on crop residue burning. Crucially, when promoting alternative sustainable uses of crop residue, the economic benefits should be prioritized, and support towards initial investments that accompany the adoption of alternative practices should be provided.


Asunto(s)
Agricultura , Nitrógeno , Asia , Productos Agrícolas , Monitoreo del Ambiente , Suelo/química
6.
Chem Commun (Camb) ; 60(27): 3721-3724, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38482771

RESUMEN

Here, we report a DNA tetrahedron dimer for dual membrane protein logic recognition and interaction inhibition. The DNA tetrahedron dimer not only detects dual proteins that are both overexpressed on target cells in "AND" logic, but also inhibits protein interaction by steric hindrance to suppress cell proliferation, offering new insights for cancer cell diagnosis and treatment.


Asunto(s)
ADN , Proteínas de la Membrana , Lógica
7.
Nat Biotechnol ; 42(3): 448-457, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37217752

RESUMEN

Recent advances in wearable ultrasound technologies have demonstrated the potential for hands-free data acquisition, but technical barriers remain as these probes require wire connections, can lose track of moving targets and create data-interpretation challenges. Here we report a fully integrated autonomous wearable ultrasonic-system-on-patch (USoP). A miniaturized flexible control circuit is designed to interface with an ultrasound transducer array for signal pre-conditioning and wireless data communication. Machine learning is used to track moving tissue targets and assist the data interpretation. We demonstrate that the USoP allows continuous tracking of physiological signals from tissues as deep as 164 mm. On mobile subjects, the USoP can continuously monitor physiological signals, including central blood pressure, heart rate and cardiac output, for as long as 12 h. This result enables continuous autonomous surveillance of deep tissue signals toward the internet-of-medical-things.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Signos Vitales
8.
Artículo en Inglés | MEDLINE | ID: mdl-37878424

RESUMEN

This perspective article provides a brief overview on materials, fabrications, beamforming, and applications for wearable ultrasound devices, a rapidly growing field with versatile implications. Recent developments in miniaturization and soft electronics have significantly advanced wearable ultrasound devices. Such devices offer distinctive advantages over traditional ultrasound probes, including prolonged usability and operator independence, and has demonstrated their effectiveness in continuous monitoring, non-invasive therapies, and advanced human-machine interfaces. Wearable ultrasound devices can be classified into three main categories: rigid, flexible, and stretchable, each having unique properties and fabrication strategies. Key unique strategies in device design, packaging, and beamforming for each type of wearable ultrasound devices are reviewed. Furthermore, we highlight the latest applications enabled by wearable ultrasound technology, encompassing continuous health monitoring, therapy, and human-machine interfaces. This article concludes by discussing the outstanding challenges within the field and outlines potential pathways for future advancements.

9.
Nat Biomed Eng ; 7(10): 1307-1320, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37770754

RESUMEN

Owing to the proximity of the ear canal to the central nervous system, in-ear electrophysiological systems can be used to unobtrusively monitor brain states. Here, by taking advantage of the ear's exocrine sweat glands, we describe an in-ear integrated array of electrochemical and electrophysiological sensors placed on a flexible substrate surrounding a user-generic earphone for the simultaneous monitoring of lactate concentration and brain states via electroencephalography, electrooculography and electrodermal activity. In volunteers performing an acute bout of exercise, the device detected elevated lactate levels in sweat concurrently with the modulation of brain activity across all electroencephalography frequency bands. Simultaneous and continuous unobtrusive in-ear monitoring of metabolic biomarkers and brain electrophysiology may allow for the discovery of dynamic and synergetic interactions between brain and body biomarkers in real-world settings for long-term health monitoring or for the detection or monitoring of neurodegenerative diseases.

10.
Nat Biomed Eng ; 7(10): 1321-1334, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37127710

RESUMEN

Serial assessment of the biomechanical properties of tissues can be used to aid the early detection and management of pathophysiological conditions, to track the evolution of lesions and to evaluate the progress of rehabilitation. However, current methods are invasive, can be used only for short-term measurements, or have insufficient penetration depth or spatial resolution. Here we describe a stretchable ultrasonic array for performing serial non-invasive elastographic measurements of tissues up to 4 cm beneath the skin at a spatial resolution of 0.5 mm. The array conforms to human skin and acoustically couples with it, allowing for accurate elastographic imaging, which we validated via magnetic resonance elastography. We used the device to map three-dimensional distributions of the Young's modulus of tissues ex vivo, to detect microstructural damage in the muscles of volunteers before the onset of soreness and to monitor the dynamic recovery process of muscle injuries during physiotherapies. The technology may facilitate the diagnosis and treatment of diseases affecting tissue biomechanics.

11.
Cell Div ; 17(1): 1, 2022 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-35164835

RESUMEN

The centrosome is a multifunctional organelle that is known primarily for its microtubule organising function. Centrosomal defects caused by changes in centrosomal structure or number have been associated with human diseases ranging from congenital defects to cancer. We are only beginning to appreciate how the non-microtubule organising roles of the centrosome are related to these clinical conditions. In this review, we will discuss the historical evidence that led to the proposal that the centrosome participates in cell cycle regulation. We then summarize the body of work that describes the involvement of the mammalian centrosome in triggering cell cycle progression and checkpoint signalling. Then we will highlight work from the fission yeast model organism, revealing the molecular details that explain how the spindle pole body (SPB, the yeast functional equivalent of the centrosome), participates in these cell cycle transitions. Importantly, we will discuss some of the emerging questions from recent discoveries related to the role of the centrosome as a cell cycle regulator.

12.
Nat Commun ; 13(1): 7757, 2022 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-36522334

RESUMEN

Electronic patches, based on various mechanisms, allow continuous and noninvasive monitoring of biomolecules on the skin surface. However, to date, such devices are unable to sense biomolecules in deep tissues, which have a stronger and faster correlation with the human physiological status than those on the skin surface. Here, we demonstrate a photoacoustic patch for three-dimensional (3D) mapping of hemoglobin in deep tissues. This photoacoustic patch integrates an array of ultrasonic transducers and vertical-cavity surface-emitting laser (VCSEL) diodes on a common soft substrate. The high-power VCSEL diodes can generate laser pulses that penetrate >2 cm into biological tissues and activate hemoglobin molecules to generate acoustic waves, which can be collected by the transducers for 3D imaging of the hemoglobin with a high spatial resolution. Additionally, the photoacoustic signal amplitude and temperature have a linear relationship, which allows 3D mapping of core temperatures with high accuracy and fast response. With access to biomolecules in deep tissues, this technology adds unprecedented capabilities to wearable electronics and thus holds significant implications for various applications in both basic research and clinical practice.


Asunto(s)
Imagenología Tridimensional , Transductores , Humanos , Imagenología Tridimensional/métodos , Temperatura , Rayos Láser , Hemoglobinas
13.
Nat Nanotechnol ; 17(3): 292-300, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34949774

RESUMEN

Electrical impulse generation and its conduction within cells or cellular networks are the cornerstone of electrophysiology. However, the advancement of the field is limited by sensing accuracy and the scalability of current recording technologies. Here we describe a scalable platform that enables accurate recording of transmembrane potentials in electrogenic cells. The platform employs a three-dimensional high-performance field-effect transistor array for minimally invasive cellular interfacing that produces faithful recordings, as validated by the gold standard patch clamp. Leveraging the high spatial and temporal resolutions of the field-effect transistors, we measured the intracellular signal conduction velocity of a cardiomyocyte to be 0.182 m s-1, which is about five times the intercellular velocity. We also demonstrate intracellular recordings in cardiac muscle tissue constructs and reveal the signal conduction paths. This platform could provide new capabilities in probing the electrical behaviours of single cells and cellular networks, which carries broad implications for understanding cellular physiology, pathology and cell-cell interactions.


Asunto(s)
Fenómenos Electrofisiológicos , Miocitos Cardíacos , Potenciales de Acción , Comunicación Celular
14.
Nat Commun ; 12(1): 1542, 2021 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-33750816

RESUMEN

Despite the fast development of various energy harvesting and storage devices, their judicious integration into efficient, autonomous, and sustainable wearable systems has not been widely explored. Here, we introduce the concept and design principles of e-textile microgrids by demonstrating a multi-module bioenergy microgrid system. Unlike earlier hybrid wearable systems, the presented e-textile microgrid relies solely on human activity to work synergistically, harvesting biochemical and biomechanical energy using sweat-based biofuel cells and triboelectric generators, and regulating the harvested energy via supercapacitors for high-power output. Through energy budgeting, the e-textile system can efficiently power liquid crystal displays continuously or a sweat sensor-electrochromic display system in pulsed sessions, with half the booting time and triple the runtime in a 10-min exercise session. Implementing "compatible form factors, commensurate performance, and complementary functionality" design principles, the flexible, textile-based bioenergy microgrid offers attractive prospects for the design and operation of efficient, sustainable, and autonomous wearable systems.


Asunto(s)
Bioingeniería/instrumentación , Ingeniería Biomédica/instrumentación , Textiles , Dispositivos Electrónicos Vestibles , Fuentes de Energía Bioeléctrica , Fenómenos Biomecánicos , Técnicas Biosensibles/instrumentación , Humanos , Sudor
15.
Nat Biomed Eng ; 5(7): 737-748, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33589782

RESUMEN

Monitoring the effects of daily activities on the physiological responses of the body calls for wearable devices that can simultaneously track metabolic and haemodynamic parameters. Here we describe a non-invasive skin-worn device for the simultaneous monitoring of blood pressure and heart rate via ultrasonic transducers and of multiple biomarkers via electrochemical sensors. We optimized the integrated device so that it provides mechanical resiliency and flexibility while conforming to curved skin surfaces, and to ensure reliable sensing of glucose in interstitial fluid and of lactate, caffeine and alcohol in sweat, without crosstalk between the individual sensors. In human volunteers, the device captured physiological effects of food intake and exercise, in particular the production of glucose after food digestion, the consumption of glucose via glycolysis, and increases in blood pressure and heart rate compensating for oxygen depletion and lactate generation. Continuous and simultaneous acoustic and electrochemical sensing via integrated wearable devices should enrich the understanding of the body's response to daily activities, and could facilitate the early prediction of abnormal physiological changes.


Asunto(s)
Biomarcadores/metabolismo , Técnicas Biosensibles/métodos , Hemodinámica/fisiología , Presión Sanguínea , Ingestión de Alimentos , Técnicas Electroquímicas , Ejercicio Físico , Glucosa/metabolismo , Frecuencia Cardíaca , Humanos , Ácido Láctico/metabolismo , Sudor/química , Sudor/metabolismo , Dispositivos Electrónicos Vestibles
16.
Nat Biomed Eng ; 5(7): 749-758, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34272524

RESUMEN

Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.


Asunto(s)
Hemodinámica/fisiología , Monitoreo Fisiológico/métodos , Circulación Cerebrovascular/fisiología , Corazón/fisiología , Humanos , Análisis por Micromatrices , Monitoreo Fisiológico/instrumentación , Relación Señal-Ruido , Ultrasonografía Doppler , Dispositivos Electrónicos Vestibles
17.
Nat Biomed Eng ; 2(9): 687-695, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30906648

RESUMEN

Continuous monitoring of the central-blood-pressure waveform from deeply embedded vessels, such as the carotid artery and jugular vein, has clinical value for the prediction of all-cause cardiovascular mortality. However, existing non-invasive approaches, including photoplethysmography and tonometry, only enable access to the superficial peripheral vasculature. Although current ultrasonic technologies allow non-invasive deep-tissue observation, unstable coupling with the tissue surface resulting from the bulkiness and rigidity of conventional ultrasound probes introduces usability constraints. Here, we describe the design and operation of an ultrasonic device that is conformal to the skin and capable of capturing blood-pressure waveforms at deeply embedded arterial and venous sites. The wearable device is ultrathin (240 µm) and stretchable (with strains up to 60%), and enables the non-invasive, continuous and accurate monitoring of cardiovascular events from multiple body locations, which should facilitate its use in a variety of clinical environments.

18.
Food Chem ; 229: 663-673, 2017 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-28372229

RESUMEN

To evaluate the feasibility of substituting eggs in yellow cake by a mixture of soybean proteins, plant polysaccharides, and emulsifiers, the batter properties, including specific gravity and viscosity; cake properties, including specific volume, texture, colour, moisture, microstructures, and structural properties of starch and glutens of the replaced cake and traditional cake containing egg, were evaluated. Replacing eggs with a soy protein isolate and 1% mono-, di-glycerides yielded a similar specific volume, specific gravity, firmness and moisture content (1.92 vs. 2.08cm3/g, 0.95 vs. 1.03, 319.8 vs. 376.1g, and 28.03% vs. 29.01%, respectively) compared with the traditional cakes baked with eggs. Structurally, this formulation comprised dominant gliadin aggregates in the size range of 100-200nm and glutenin networking structures containing fewer but larger porosities. The results suggest that a mixture of soybean proteins and emulsifier is a promising substitute for eggs in cakes.


Asunto(s)
Huevos/análisis , Microscopía de Fuerza Atómica/métodos , Polisacáridos/química , Proteínas de Soja/química , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Vegetarianos , Almidón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA