Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Ophthalmol ; 14: 1091-1100, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32425495

RESUMEN

PURPOSE: To identify the laser programming strategy that will achieve optimal refractive outcomes of LASIK with a topography-guided laser for eyes with a disparity between cylinder measured by manifest refraction and cylinder measured by topography. SETTING: Six surgeons at 5 clinical sites in the USA. DESIGN: Retrospective data review. METHODS: Preoperative, treatment, and postoperative data on 52 eyes that underwent topography-guided LASIK with the WaveLight EX500 Contoura® Vision excimer laser ablation profile in which the vectors representing the preoperative refractive cylinder and the cylinder measured by the WaveLight® Topolyzer™ VARIO Diagnostic Device (Vario cylinder) differed by >/= 0.50D and/or >/= 10 degrees of orientation were analyzed retrospectively. Data were contributed by six surgeons using the laser at 5 different clinical sites. Vector analysis of postoperative cylindrical refractive error and the actual laser programming strategy was used to calculate the cylindrical correction that would, theoretically, have completely eliminated postoperative refractive cylinder. This was compared to expected results using the preoperative manifest cylinder, the topographic cylinder, and the Phorcides Analytic Engine (Phorcides LLC, North Oaks MN; Phorcides). For analysis, subjects were stratified on the basis of the vector difference between Manifest and Topo cylinder (High, >0.75 D; and Low, ≤0.75 D). RESULTS: The poorest calculated theoretical outcomes were obtained with the manifest refraction (centroid: -0.43, 0.22; mean calculated error vector: 0.56 ± 0.42 D; p=ns). Better outcomes were obtained with the topographically measured refraction (centroid: 0.37, 0.02; mean calculated error vector: 0.47 ± 0.33 D; p=ns). The best outcomes were obtained with Phorcides (centroid: -0.15, 0.06; mean calculated error vector: 0.39 ± 0.28 D; p=ns). The mean error vector magnitude in the Phorcides Low group was significantly lower than for the Manifest and Topo Low groups (0.26 D vs 0.48 D and 0.33 D; p<0.01). The mean error magnitude in the Phorcides High group was nearly 0.25 D lower than for the Manifest High group (0.48 D vs 0.70 D; p<0.01), but was the same as for the Topo High group (0.48 D vs 0.48 D). CONCLUSION: Our study suggests that using the topographically measured cylinder or the cylinder selected by Phorcides will produce more desirable refractive outcomes than entry of the preoperative refractive cylinder as the basis for correction of myopia and myopic astigmatism with the WaveLight Contoura Vision excimer laser.

2.
Anat Rec (Hoboken) ; 293(11): 1805-15, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20730867

RESUMEN

This study describes a novel cytoskeletal array in fiber cells of the ocular lens of the rat and shows its relationship to the classical terminal web of other epithelial tissues. Naive adult Sprague-Dawley rats (n = 28) were utilized. F-actin, fodrin, myosin IIA, and CP49 distribution was assessed in anterior and posterior polar sections. For functional analysis, lenses were cultured with or without cytochalasin-D for 3 hr, then processed for confocal microscopy or assessed by laser scan analysis along sutures. Phalloidin labeling demonstrated a dense mesh of F-actin adjacent to posterior sutural domains to a subcapsular depth of 400 µm. Anterior polar sections revealed a comparable actin structure adjacent to anterior suture branches however, it was not developed in superficial fibers. Fodrin and myosin were localized within the web-like actin apparatus. The data was used to construct a model showing that the cytoskeletal array is located within the blunt, variable-width fiber ends that abut at sutures such that the "terminal web" flanks the suture on either side. Treatment with cytochalasin-D resulted in partial disassembly of the "terminal web" and perturbed cellular organization. Laser scan analysis revealed that cytochalasin-D treated lenses had significantly greater focal variability than control lenses (P = 0.020). We conclude that cortical fibers of rat lenses contain a bipolar structure that is structurally and compositionally analogous to classical terminal webs. The results indicate that the lens "terminal web" functions to stabilize lens fiber ends at sutures thus minimizing structural disorder, which in turn, promotes the establishment and maintenance of lens transparency.


Asunto(s)
Citoesqueleto/fisiología , Citoesqueleto/ultraestructura , Cristalino/citología , Cristalino/fisiología , Actinas/análisis , Actinas/fisiología , Actinas/ultraestructura , Animales , Proteínas Portadoras/análisis , Proteínas Portadoras/fisiología , Proteínas Portadoras/ultraestructura , Citocalasina D/farmacología , Citoesqueleto/efectos de los fármacos , Proteínas del Ojo/análisis , Proteínas del Ojo/fisiología , Proteínas del Ojo/ultraestructura , Proteínas de Filamentos Intermediarios/análisis , Proteínas de Filamentos Intermediarios/fisiología , Proteínas de Filamentos Intermediarios/ultraestructura , Cristalino/química , Proteínas de Microfilamentos/análisis , Proteínas de Microfilamentos/fisiología , Proteínas de Microfilamentos/ultraestructura , Microscopía Confocal , Miosina Tipo IIA no Muscular/análisis , Miosina Tipo IIA no Muscular/fisiología , Miosina Tipo IIA no Muscular/ultraestructura , Inhibidores de la Síntesis del Ácido Nucleico/farmacología , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA